• Title/Summary/Keyword: reference air line

Search Result 36, Processing Time 0.021 seconds

A Study of Targeted Killing, Unmanned Aerial Vehicles (무인항공기 표적살인(Targeted Killing)에 관한 고찰: 논쟁과 실행 정당성을 중심으로)

  • So, Jae-Seon;Lee, Chang-Kyu
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.32 no.1
    • /
    • pp.53-81
    • /
    • 2017
  • Targeted killing is a modern euphemism for the assassination of an individual by a state organization or institution outside a judicial procedure or a battlefield. Targeted killing using armed drones has raised profound anxieties in legal, policy, and advocacy communities in the United States and abroad, including among UN officials. The bottom line for targeted killing supporters is that targeted killing works as part of a larger counter-terrorism strategy. Targeted killing does what it is supposed to and removes the leader of a group. And despite growing legal, moral, and ethical issues concerning targeted killing, scholars agree that drone strikes and targeted killing operations will stay. The ACLU has sued top CIA and Pentagon decision-makers to seek accountability for the unlawful killings of three U.S. citizens in Yemen last year. Also, strikes by drones are associated with serious problems such as collateral damage to ordinary citizens and friendly fire. Targeted killings by drones also involves several issues to be resolved, including suspicions that they may run counter to domestic law prohibiting assassination, the opacity concerning their definitions and military actions, and the impact of whiplash transition. Finally, targeted killing program and the need for transparency. The assembly referring to resolution invites the committee of ministers to undertake a thorough study of the lawfulness of the use of combat drones for targeted killings and if need be develop guidelines for member states on targeted killings with a special reference to those carried out by combat drones. These guidelines should reflect the states duties under international humanitarian and human rights law in particular the standards laid down in the EC on human rights as interpreted by the european court of human rights.

  • PDF

A Study on the Vertical Temperature Difference of Steel Box Girder Bridge by Field Measurement (실측에 의한 강박스거더교의 상하 온도차에 대한 연구)

  • Lee, Seong-Haeng;Park, Young-Chun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.545-551
    • /
    • 2018
  • For domestic application of the temperature gradient model proposed by foreign design standards, a specimen of steel box girder bridge was fabricated with the following dimensions: 2.0 m width, 2.0 m height and 3.0 m length. Temperature was measured using 24 temperature gauges during the summer of 2016. The reliability of the measured data was verified by comparing the measured air temperature with the ambient air temperature of the Korea Meteorological Administration. Of the measured gauges, four temperature gauges that can be compared with the temperature difference of the Euro code were selected and used to analyze the distribution of the measured temperatures at each point. The reference atmospheric temperature for the selection of the maximum temperature difference was determined by considering the standard error. Maximum and minimum temperatures were calculated from the four selected points and the resulting temperature difference was calculated. The model for the temperature difference in the steel box girder bridge was shown by graphing the temperature difference. Compared to the temperature distribution of the Euro code, the presented temperature difference model showed a temperature difference of $0.9^{\circ}C$ at the top and of $0.3^{\circ}$ to $0.4^{\circ}C$ at the intermediate part. These results suggested that the presented model could be considered relatively similar to the Euro code The calculated standard error coefficient was 2.71 to 2.84 times the standard error and represents a range of values. The proposed temperature difference model may be used to generate basic data for calculating the temperature difference in temperature load design.

A Study on Takeoff Decision Speed Improvement of Air Transport Airplane (운송용항공기의 이륙단념속도 개선에 관한 연구)

  • Noh, Kun-Doo;Choi, Youn-Chul;Yoo, Kwang-Eui
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.4 s.82
    • /
    • pp.7-16
    • /
    • 2005
  • Rejected Takeoff Accidents are not common. but if occurred, it leads to big disaster From the year of 1959, when Jet Transport service opened, to the year of 2000, Rejected Takeoff accidents/incidents occurred total of 94 cases. All cases led to overrun, and major cause is to initiate stopping maneuvers over $V_1$, takeoff decision speed, according to National Transport Safety Board of America. Similar results are represented in Aviation Safety Reporting System of National Aeronautics and Space Administration. So I believe that it is worth studying if Airplane Flight Manual, which is the reference Performance criteria, is appropriate to operations of line pilots. The definition of $V_1$ has been revised a couple of times and Rejected Takeoff Certification Standards for Transport Airplanes was changed in 1998. It shows that up to now there are some portions unreasonable. This study focused on gathering the pilot's tendency for current Rejected Takeoff Procedures of K airlines and analyze the factors they concern. I chose B777 airplane and actually measured the recognition and reaction time of the rejected takeoff transitions through Simulators. And compared the results with the data of flight test and Airplane Flight Manual.

Compression of Multispectral Images (멀티 스펙트럴 영상들의 압축)

  • Enrico Piazza
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.1
    • /
    • pp.28-39
    • /
    • 2003
  • This paper is an overview of research contributions by the authors to the use of compression techniques to handle high resolution, multi-spectral images. Originally developed in the remote sensing context, the same techniques are here applied to food and medical images. The objective is to point out the potential of this kind of processing in different contexts such as remote sensing, food monitoring, and medical imaging and to stimulate new research exploitations. Compression is based on the simple assumption that it is possible to find out a relationship between pixels close one each other in multi-spectral images it translates to the possibility to say that there is a certain degree of correlation within pixels belonging to the same band in a close neighbourhood. Once found a correlation based on certain coefficient on one band, the coefficients of this relationship are, in turn, quite probably, similar to the ones calculated in one of the other bands. Based upon this second observation, an algorithm was developed, able to reduce the number of bit/pixel from 16 to 4 in satellite remote sensed multi-spectral images. A comparison is carried out between different methods about their speed and compression ratio. As reference it was taken the behaviour of three common algorithms, LZW (Lempel-Ziv-Welch), Huffman and RLE (Run Length Encoding), as they are used in common graphic format such as GIF, JPEG and PCX. The Presented methods have similar results in both speed and compression ratio to the commonly used programs and are to be preferred when the decompression must be carried out on line, inside a main program or when there is the need of a custom made compression algorithm.

  • PDF

The Study on development of a SAW SO$_2$ gas sensor (표면탄성파를 이용한 아황산 가스센서 개발에 관한 연구)

  • Lee, Young-Jin;Kim, Hak-Bong;Roh, Yong-Rae;Cho, Hyun-Min;Baik, Sung;,
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.89-94
    • /
    • 1997
  • A new type SO$_2$ gas sensor with a particular inorganic thin film on SAW devices was developed. The sensor consisted of twin SAW oscillators of the center frequency of 54 MHz fabricated on the LiTaO$_3$ piezoelectric single crystal. One delay line of the sensor was coated with a CdS thin film that selectively adsorbed and desorbed SO$_2$, while the other was uncoated for use as a stable reference. Deposition of the CdS thin film was carried out by the spray pyrolysis method using an ultrasonic nozzle. The sensor could measure the concentration in air less than 0.25 parts per million of SO$_2$. Stability of the sensor turned out to be as good as less than 20ppm, recovery time after each measurement was as short as 5 minutes. Repeatability of the measurement was confirmed through so many reiterated experiments. Hence, the SAW sensor developed through this work showed promising performance as a microsensing tool of SO$_2$. Further work required to improve the performance of the sensor includes enhancement of the reactivity of the CdS thin film with SO$_2$ through appropriate dopant addition, an increase of the center frequency of the SAW device.

  • PDF

The Sampling Efficiencies of Volatile Organic Compounds(VOCs) to the Diffusive Monitor with Activated Carbon Fiber (활성탄섬유를 이용한 확산포집기의 공기 중 유기용제 포집효율에 관한 연구)

  • Byeon, Sang-Hoon;Park, Cheon-Jae;Oh, Se-Min;Lee, Chang-Ha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.187-201
    • /
    • 1996
  • This study was to evaluate the efficiency of diffusive monitor using activated carbon fiber(ACF, KF-1500) in measuring airborne organic solvents. The following characteristics were identified and studied as critical to the performance of diffusive monitor; recovery, sampling rate, face velocity, reverse diffusion and storage stability. For the evaluation of the performance of this monitor, MIBK, PCE, toluene were used as organic solvents. In the sampling rate experiments, eight kinds of solvents (n-hexane, MEK, DIBK, MCF, TCE, CB, xylene, cumene) as well as the above solvents were used. The results were as follows: 1. The desorption efficiencies(DE's) of ACF diffusive monitor ranged from 83 % to 101 %. In contrast, those of coconut shell charcoal ranged from 78 % to 102 %. Especially, the DE's of ACF for the polar solvents such as MEK were superior to those of charcoal. 2. Experimental sampling rates on ACF were average 42ml/min(37-46ml/min) for 11 organic solvents at $24{\pm}2^{\circ}C$, $50{\pm}5%RH$. However ideal sampling rates(DA/L) were 33 % higher than experimental sampling rates. 3. The initial response(15~16 min) of the testing monitor was 2 times higher than the actual concentration determined by the reference methods at $24{\pm}2^{\circ}C$, $8{\pm}5%RH$ and $80{\pm}5%RH$. Within 1 hours, the curve reached a linear horizontal line at low humidity condition. But sampling efficiencies decreased with respect to time at high humidity condition. And sampling efficiencies were higher at high humidity condition than low humidity condition for MIBK. 4. At very low velocity (less than 0.02 m/sec), the concentration of ACF diffusive monitor were poorly estimated. But ACF diffusive monitor were not affected at higher velocity(0.2 m/sec-0.6 m/sec). 5. There was no significant reverse diffusion when the ACF monitors were exposed to clean air for 2 hours after being exposed for 2 hours at the level of 1 TLV. 6. There was no significant sample loss during 3 weeks of storage at room temperature and 5 weeks of storage at refrigeration.

  • PDF