• Title/Summary/Keyword: redundant architecture

Search Result 93, Processing Time 0.033 seconds

Availability analysis of subsea blowout preventer using Markov model considering demand rate

  • Kim, Sunghee;Chung, Soyeon;Yang, Youngsoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.4
    • /
    • pp.775-787
    • /
    • 2014
  • Availabilities of subsea Blowout Preventers (BOP) in the Gulf of Mexico Outer Continental Shelf (GoM OCS) is investigated using a Markov method. An updated ${\beta}$ factor model by SINTEF is used for common-cause failures in multiple redundant systems. Coefficient values of failure rates for the Markov model are derived using the ${\beta}$ factor model of the PDS (reliability of computer-based safety systems, Norwegian acronym) method. The blind shear ram preventer system of the subsea BOP components considers a demand rate to reflect reality more. Markov models considering the demand rate for one or two components are introduced. Two data sets are compared at the GoM OCS. The results show that three or four pipe ram preventers give similar availabilities, but redundant blind shear ram preventers or annular preventers enhance the availability of the subsea BOP. Also control systems (PODs) and connectors are contributable components to improve the availability of the subsea BOPs based on sensitivity analysis.

A design of Adaptive Decision-feedback Equalizer Module using Redundant Binary Complex Filter (Redundant Binary 복소수 필터를 이용한 적응 결정귀환 등화기 모듈 설계)

  • 김호하;안병규신경욱
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.1125-1128
    • /
    • 1998
  • A new architecture for high-speed implementation of adaptive decision-feedback equalizer (ADFE) applicable to wide-band digital wireless modems is described. Rather than using conventional two's complement arithmetic, a novel complex-valued filter structure is devised, which is based on redundant binary (RB) arithmetic. The proposed RB complex-valued filter reduces the critical path delay of ADFE, as well as leads to a more compact implementation than conventional methods. Also, the carry-propagation free (CPF) operation of the RB arithmetic enhances its speed. To demonstrate the proposed method, a prototype chip set is designed. They are designed to contain two complexvalued filter taps along with their coefficient updating circuits, and can be cascaded to implement loger filter taps for high bit-rate applications.

  • PDF

Data Handling System Design for COMS (통신해양기상위성의 데이터처리 시스템 설계)

  • Cho, Young-Ho;Won, Joo-Ho;Choi, Jae-Dong;Yang, Koon-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.246-248
    • /
    • 2009
  • In this paper, we will describe architecture and key characteristic for the DHS which is used in COMS. DHS is implemented in the fully redundant SCU, the dual redundant MIL-STD-1553B system bus, the payload interface units(MPIU and MI2U), the redundant ADE. the SCU interface with the other main digital units of the spacecraft through the MIL-STD-1553B.

  • PDF

Design of Extended Real-time Data Pipeline System Architecture (확장형 실시간 데이터 파이프라인 시스템 아키텍처 설계)

  • Shin, Hoseung;Kang, Sungwon;Lee, Jihyun
    • Journal of KIISE
    • /
    • v.42 no.8
    • /
    • pp.1010-1021
    • /
    • 2015
  • Big data systems are widely used to collect large-scale log data, so it is very important for these systems to operate with a high level of performance. However, the current Hadoop-based big data system architecture has a problem in that its performance is low as a result of redundant processing. This paper solves this problem by improving the design of the Hadoop system architecture. The proposed architecture uses the batch-based data collection of the existing architecture in combination with a single processing method. A high level of performance can be achieved by analyzing the collected data directly in memory to avoid redundant processing. The proposed architecture guarantees system expandability, which is an advantage of using the Hadoop architecture. This paper confirms that the proposed architecture is approximately 30% to 35% faster in analyzing and processing data than existing architectures and that it is also extendable.

Development of the remote controlled robotic system in nuclear facilities (원자력시설내의 원격 제어 로보트 시스템 개발)

  • 황석용;손석원;김승호;이종민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.230-234
    • /
    • 1989
  • This paper presents the design of a prototype robot and architecture of a distributed control system. The robot, named as KAEROT, has been developed for the purpose of the reduction of personal radiation exposure and the remote maintenance tasks in nuclear facilities. The mobile system with robotic manipulator has been designed to go up and down stairs. For the dextrous handling, this manipulator will be designed as a redundant type to act like a human arm. Manipulator control system is to be extended easily for further usage with a modular architecture to get independency and reliability by minimizing EMI effects.

  • PDF

A Study on the Improvement of Safety Instrumented Function of Hydrogen Refueling Station Considering Individual Risk (개인적 위험도를 고려한 수소충전소의 안전계장기능 향상에 관한 연구)

  • YOON SUP BYUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.3
    • /
    • pp.297-306
    • /
    • 2023
  • The frequency of fatal accidents that can occur at hydrogen refueling station was compared with the risk criterion for the general public suggested by the health and safety executive. If hydrogen refueling station meets the accident prevention facility standards presented in KGS Code FP216/217, it was confirmed that the risk of hydrogen refueling station was not at an unacceptable (intolerable) risk level. However, the risk of hydrogen refueling station due to small leak was analyzed as low as reasonably practicable. Therefore, methods for improving the safety instrumented function of hydrogen refueling station were reviewed. It was confirmed that the risk of hydrogen refueling station can be affected by the number of installed safety instrumentation system components, redundant architecture, mission time, proof test interval, etc. And methods for maintaining the risk of hydrogen refueling station at an acceptable risk level have been proposed.

Reliability Analysis of Redundant Architecture of Dependable Control System (다중화 구조 제어시스템에 대한 신뢰도 분석)

  • Noh, Jinpyo;Park, Jaehyun;Son, Kwang-Seop;Kim, Dong-Hoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.4
    • /
    • pp.328-333
    • /
    • 2013
  • Since a slight malfunction of control systems in a nuclear power plant may cause huge catastrophes, such control systems usually have multiple redundancy and reliable features, and their reliability and availability should be analyzed and verified thoroughly. This paper performed the reliability analysis of the SPLC (Safety Programmable Logic Controller) that is under developed as the control systems for the next generation nuclear power plant. One of the key features of SPLC is that it has multiple redundancy modes as faults happen, which means the reliability analysis for one fixed redundant model is not enough to analyze the reliability of SPLC. With considering this reconfigurable concept, FTA (Fault Tree Analysis) was used to capture fault-relationship among sub-modules. The analysis results show that MTTF (Mean Time to Fault) of SPLC is 45,080 hours, which is a about 4.5 times longer than the regulation, 10,000 hours.

MVC Architecture-aware Restructuring of Web Apps (MVC 아키텍처 인지하는 웹 앱 재구조화)

  • Oh, Jaewon;Ahn, Woo Hyun;Kim, Taegong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.11
    • /
    • pp.2153-2166
    • /
    • 2017
  • Web apps have a problem that they cause same data to be repetitively retrieved, processed, and displayed when web browsers load different web pages. To resolve the problem, this paper presents and evaluates a new method for restructuring of Java web apps. This approach dynamically analyzes Java web apps from the MVC (Model-View-Controller) architecture point of view and identifies redundant data by using the composite view pattern. Then the input apps are restructured in order not to load the redundant data when users make requests for new pages. This restructuring generates new web apps that conform to the MVC architecture and improve the performance of input web apps. The experimental results showed that when compared to legacy web apps, the restructured apps' response time was reduced on desktop PCs and mobile devices by 38% and 55%, respectively. In addition, case studies using open-source web apps showed the applicability of the proposed approach.

A design and implementation of high-performance 2D PE architecture in H.264 Motion Estimation (H.264 움직임 추정의 고속 2D PE 아키텍쳐 설계 및 구현)

  • Lee, Kyung-Ho;Kong, Jin-Hyeung
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.405-406
    • /
    • 2008
  • This paper presents a high performance 2D PE architecture for H.264 Motion Estimation(ME). While existing 2D PE architectures reuse the overlapped data of adjacent search windows scanned in 1 or 3-way, the new architecture scan adjacent windows and multiple paths instead of single raster and zigzag scanning of adjacent windows in 4 way(up,down,left,right). By reducing the redundant access factor by 1.4, the new 4-way search window improve the memory bandwidth by 70-58% compared with 1/3-way search window. With Altera Stratix-III implementation, the high performance 2D PE architecture deals with SD ($720{\times}480$) video of 2 reference frame, $48{\times}48$ search area and $16{\times}16$ macroblock by 30fps at 97.1MHz.

  • PDF

Redundant Architectural Design of Hydraulic Control System for Reliability Improvement of Underwater Construction Robot (수중건설로봇의 유압 제어 안정성 향상을 위한 이중화 설계)

  • Lee, Jung-Woo;Park, Jeong-Woo;Suh, Jin-Ho;Choi, Young-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.380-385
    • /
    • 2015
  • In the development of an underwater construction robot, the reliability of the operating system is the most important issue because of its huge maintenance cost, especially in a deep sea application. In this paper, we propose a new redundant architectural design for the hydraulic control system of an underwater construction robot. The proposed architecture consists of dual independent modular redundancy management systems linked with a commercial profibus network. A cold standby redundancy management system consisting of a preprocessing switch circuit is applied to the signal network, and a hot standby redundancy management system is adapted to utilize two main controllers.