• 제목/요약/키워드: reduction of fouling

검색결과 135건 처리시간 0.027초

Insight into influence of iron addition in membrane bioreactor on gel layer fouling

  • Zhang, Haifeng;Lu, Xin;Yu, Haihuan;Song, Lianfa
    • Membrane and Water Treatment
    • /
    • 제8권6호
    • /
    • pp.543-551
    • /
    • 2017
  • Membrane fouling in membrane bioreactor (MBR) remains a primary challenge for its wider application. The focus of this study to investigate the influence of iron distribution in activated sludge on gel layer fouling in MBR. Significant reduction in the transmembrane pressure (TMP) rise rates was observed in the presence of iron as result of retarding the gel layer formation time. The spatial distribution of iron had a significant impact on the stratification structure of extracellular polymeric substances (EPS) fractions, such as proteins (PN) and polysaccharides (PS). A mitigation of PN or PS from the supernatant to the EPS inner layers was observed in the presence of iron. Compared with the control reactor, the reduction in PN and PS of the supernatant and lower PN/PS rates of the LB-EPS were beneficial to decrease the membrane fouling potential during the gel layer formation. Consequently, the iron addition managed to control gel layer fouling could be a useful strategy in MBR.

전기응집 분리 막 생물반응기의 막 오염 저감 (Membrane fouling reduction using electro-coagulation aided membrane bio-reactor)

  • 김완규;홍성준;장인성
    • 한국산학기술학회논문지
    • /
    • 제19권8호
    • /
    • pp.105-114
    • /
    • 2018
  • 전기응집 (Electro-coagulation)을 활용한 분리 막 생물반응기 (Membrane Bio-Reactor) 공정의 막 오염 저감 현상을 확인하고 이를 해석하고자 하였다. 전기응집의 주요 운전 인자인 전류밀도와 접촉시간 변화가 활성슬러지 혼합액의 막 여과에 미치는 영향을 관찰하고 전기응집 과정에서 발생하는 수산화금속염이 막 오염에 미치는 역할에 대해 연구하였다. 전류밀도를 $10A/m^2$으로 높게 유지한 경우에는 전기응집 시간이 증가하여도 막 오염 감소 효과가 크지 않은 반면 $2.5A/m^2$의 낮은 전류밀도 하에서는 전기응집 시간이 증가하면 추가적인 막 오염 감소가 관찰되었다. 즉, 막 오염을 감소시키는 전류밀도와 접촉시간의 곱이 전체 막 오염 저감 정도를 지배하고 있음을 확인하였다. 또한 주어진 전류밀도와 인가시간에서 입도분포는 크게 변화하지 않은 것으로 나타나 콜로이드 입자와 막 오염 저감과는 큰 관련성이 없는 것으로 판단되었다. 그러나 전기응집을 통해 생성된 수산화알루미늄 (인산알루미늄)이 막 여과 과정에서 동적 막 (Dynamic Membrane)을 형성하여 막 오염 현상을 완화하는 것으로 확인되었다. 전기응집에서 발생한 수산화금속염이 막 표면에 동적 막을 형성하고 이로 인해 유입수의 입자성분이 직접 막 표면과 내부에 침적되는 것을 방해하고 동적 막에 주로 쌓이게 함으로써 막 오염이 감소된 것이다. 본 연구에서 밝힌 수산화금속염에 의한 동적 막의 역할은 전기응집을 활용한 MBR 공정의 후 막 오염 감소 메커니즘을 해석하는데 중요한 역할을 한다고 결론지을 수 있다.

상사축척법에 기반한 저마찰 선박 방오도료의 실선 마찰저항 저감성능 추정 (Full Scale Frictional Resistance Reduction Effect of a Low Frictional Marine Anti-fouling Paint based on a Similarity Scaling Method)

  • 양정우;박현;이인원
    • 대한조선학회논문집
    • /
    • 제54권1호
    • /
    • pp.71-81
    • /
    • 2017
  • In this study, a series of full-scale extrapolation procedures based on the Granville's similarity scaling method, which was employed by Schultz (2007), is modified and then applied to compare the resistance performance between two different anti-fouling coatings. As an analysis example, the low frictional AF coating based on a novel skin-friction reducing polymer named FDR-SPC (Frictional Drag Reduction Self-Polishing Copolymer), which had been invented by the present author, is employed. The low frictional coating, which gives 25.4% skin frictional reduction in lab test, is estimated to give 18.2% total resistance reduction for a 176k DWT bulk carrier.

Utilization of aerobic granulation to mitigate membrane fouling in MBRs

  • Iorhemen, Oliver T.;Hamza, Rania A.;Tay, Joo Hwa
    • Membrane and Water Treatment
    • /
    • 제8권5호
    • /
    • pp.395-409
    • /
    • 2017
  • Membrane bioreactor (MBR) is a compact and efficient wastewater treatment and reclamation technology; but, it is limited by membrane fouling. The control of membrane fouling significantly increases operational and maintenance costs. Bacteria and their byproducts - extracellular polymeric substances (EPS) - are major contributors to membrane fouling in MBRs. A recent attempt at fouling mitigation is the development of aerobic granular sludge membrane bioreactor (AGMBR) through the integration of a novel biotechnology - aerobic granulation - and MBR. This paper provides an overview on the development of AGMBR to mitigate membrane fouling caused by bacteria and EPS. In AGMBR, EPS are used up in granule formation; and, the rigid structure of granules provides a surface for bacteria to attach to rather than the membrane surface. Preliminary research on AGMBR using synthetic wastewater show remarkable membrane fouling reduction compared to conventional MBR, thus improved membrane filtration. Enhanced performance in AGMBR using actual municipal wastewater at pilot-scale has also been reported. Therefore, further research is needed to determine AGMBR optimal operational conditions to enhance granule stability in long-term operations and in full-scale applications.

정삼투 멤브레인 공정에서 칼슘이온과 용존 유기물 상호작용에 의한 플럭스 변화 연구 (Systematic study on calcium-dissolved organic matter interaction in a forward osmosis membrane-filtration system)

  • 허지용;한종훈;김예진;허남국
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.737-744
    • /
    • 2016
  • The investigation of effects on fouling propensity with various viscosity of feed solutions would be better understanding for forward osmosis (FO) performance since the fouling propensity was directly influenced with solution viscosity. Therefore, this study was focused on the FO fouling with model foultants (humic acid, alginate) by altering solution viscosity with change of ionic strength (I.S) and $Ca^{2+}$ concentrations. In the comparison between humic acid and alginate, as expected, the alginate generally caused more severe fouling (almost 35.8 % of flux reduction) based on the solution characteristics (high viscosity) and fouling patterns (coil and gel layer). However, interesting point to note is that the fouling propensity of alginate was more severe even though it was applied with low viscosity of feed conditions (I.S = 20 mM, $Ca^{2+}=1mM$). This might be due to that crossed linked gel layer of alginate on the FO membrane surface could be best formed in the condition of $Ca^{2+}$ presence and higher I.S, and that is more dominant to fouling propensity than the low viscosity of feed solutions.

Modification methods of polyethersulfone membranes for minimizing fouling - Review

  • Sathish Kumar, R.;Arthanareeswaran, G.;Paul, Diby;Kweon, Ji Hyang
    • Membrane and Water Treatment
    • /
    • 제6권4호
    • /
    • pp.323-337
    • /
    • 2015
  • Membrane Fouling was considered as major drawback in various industrial applications. Thus, this paper reviews the surface modification of polyethersulfone (PES) membranes for antifouling performance. Various modification techniques clearly indicate that hydrophilicity has to improve on the PES membrane surface. Moreover, the mechanism of fouling reduction with corresponds to various modification methods is widely discussed. Incorporation of hydrophilic functional groups on PES membrane surface enhances the surface free energy thereby which reduces the fouling. Characterization techniques adopted for the surface modified membranes was also discussed. These studies might be useful for the other researchers to utilize the modification technique for the applications of waste water treatment, chemical process industry and food industry.

MF Membrane Application for Water Treatment in Japan

  • Okazaki, Minoru
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1995년도 추계 총회 및 학술발표회
    • /
    • pp.80-93
    • /
    • 1995
  • Membrane Technology, which has been in use for over twenty five years, has established itself as one of the principle separation methods. With improved technology, Reverse Osmosis ("RO") has been applied to large volume water treatment facilities. UF and MF Membrane Technology has, up until recently, been applied to small scale water treatment facilities. The fouling of membrane has restricted the growth of Membrane Technology in Water Treatment. Membrane fouling compound found in water causes the loss of flux across the membrane by absorbing to membrane and plugging their pores. Various methods have been used in the reduction and prevention of membrane fouling. For RO, a conventional pre-treatment system removes the pollutants, preventing the function decline of RO membrane by keeping SDI < 4 as the standard condition of feed water. UF and MF Membrane Technology that must have pre-treatment function within itself, are required to keep its ability not to be influenced by fouling.y fouling.

  • PDF

순환유동층 열교환기 내의 화울링 저감 및 열전달 향상 기구 (Mechanism of Fouling Reduction and Heat Transfer Enhancement in a Circulating Fluidized Bed Heat Exchanger)

  • 이윤표;윤성영;정종수;김내현
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.450-460
    • /
    • 1995
  • A modified circulating fluidized bed heat exchanger under severe fouling condition is developed. The effects of fouling deposits on the performance of a heat exchanger are investigated. The principle and operating characteristics of a circulating fluidized bed heat exchanger are dicussed. A modified circulating fluidized bed heat exchanger shows more stable operating than the other circulating fluidized bed heat exchanger. The characteristics of self cleaning and heat transfer enhancement of a circulating fluidized bed heat exchanger are studied. The movement of spherical particles in a tube is visualized and heat transfer enhancement and scale reduction mechanism by particles are investigated.

  • PDF

응집·한외여과 조합공정에서 플럭스와 선속도가 막오염에 미치는 영향에 관한 연구 (A Study on Membrane Fouling by Flux and Linear Velocity in Coagulation/Ultrafiltration Membrane System)

  • 문성용;이상협;김승현;윤조희
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.429-436
    • /
    • 2005
  • A coagulation/ultrafiltration membrane hybrid system was operated to treat river water with capacity of $0.06m^3/d$. The impact on membrane fouling by flux and linear velocity was investigated. It is known that pressure increase is proportional to flux increase. However, pressure increase was much faster than theoretical value in the pilot plant test. So it was suggested that flux was on important factor in ultrafiltration of continuous operation. Membrane fouling was decreased when linear velocity was increased. This phenomenon was found more obviously without coagulation. With the combination of coagulation and sedimentation, membrane fouling was not reduced conspicuously. Big particles formed during coagulation and sedimentation were destroyed by feed and circulation pumping, which resulted in little effect on membrane fouling reduction. The degree of destruction was similar at various linear velocities. In this study, the hollow fiber membrane was used and the system was operated in pressure type module. In case of the system used in this study, membrane fouling has been affected lightly by linear velocity variation when coagulation pretreatment was applied.

해수전처리를 위한 침지식 정밀여과 멤브레인 시스템에서 Alginate 파울링의 이해 (Understanding Alginate Fouling in Submerged Microfiltration Membrane System for Seawater Pretreatment)

  • 장호석;권대은;김정환
    • 멤브레인
    • /
    • 제26권1호
    • /
    • pp.55-61
    • /
    • 2016
  • 저압 침지식 멤브레인을 이용한 해수 담수화 전처리에 있어서 유기 파울링은 막간 압력 증가로 인한 화학 세정 횟수의 증가 및 에너지 소비 증가 등 멤브레인 운전시 문제점들을 야기한다. 조류대응 해수전처리에서 조류가 배출하는 extracellular polymeric substances의 대표물질인 sodium alginate를 이용하여 침지식 여과에서 파울링 현상을 관찰하였다. 공기 폭기가 적용되지 않은 경우 순수한 aglinate 파울링은 농도가 증가하면서 증가하였다. 그러나 공기 폭기를 적용해 준 경우 alginate 파울링 감소는 매우 효과적이었다. 공기 폭기가 없는 경우 칼슘 농도의 증가에 따라 alginate 파울링은 감소하였다. 동일 조건에서 공기 폭기 시 높은 alginate 파울링 감소효과를 나타내었으나 NaCl 농도를 증가시킨 경우 칼슘 농도의 증가에 따라 파울링 제어를 위한 공기 폭기 효과는 감소하였다. 해수와 유사한 높은 NaCl과 칼슘 농도에서 고농도 sodium alginate의 경우 공기 폭기량 증가를 통해 초기 파울링을 감소시킬 수 있었으나 시간의 경과에 따라 상대적으로 낮은 폭기량에서의 파울링 감소 효과와 큰 차이는 없었다.