Study on the size reduction factor of extreme wind pressure of facade cladding of high-rise buildings with square section

  • Xiang Wang;Yong Quan;Zhengwei Zhang;Ming Gu
    • Wind and Structures
    • /
    • v.36 no.1
    • /
    • pp.41-60
    • /
    • 2023
  • The effect of cladding panel size on the size reduction factor (SRF) of extreme area-averaging wind pressure (EAWP) on the facades of a high-rise building is often ignored in previous studies. Based on wind tunnel tests, this study investigated the horizontal and vertical correlations of wind pressure on the facade claddings of square-section high-rise buildings. Then, the influencing parameters on the SRF of the EAWP on the cladding panels were analyzed, which were the panel area, panel width, panel length and building width. The results show clear regional distinctions in the correlation of wind pressures on the building facades and the rules of the horizontal and vertical correlations are remarkably different, which causes the cladding size ratio to impact the SRF significantly. Therefore, this study suggests the use of the non-dimensional comprehensive size parameter b𝜶h1-𝜶/B (𝜶 is the fitting parameter) determined by the cladding panel horizontal size b, cladding panel vertical size h and the building width B rather than the cladding panel area to describe the variation of the EAWP. Finally, some empirical formula for the SRF of the EAWP on the cladding of a high-rise building is proposed with the nondimensional comprehensive size parameter.

Material Resistance Factors for Reinforced Concrete Flexural and Compression Members (철근콘크리트 휨부재 및 압축부재의 재료조항계수 적용에 관한 연구)

  • 김재홍;이재훈
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.2
    • /
    • pp.21-30
    • /
    • 2000
  • In the Ultimate Strength Design, the design strength of a member is determined by multiplying the strength reduction factor to the nominal strength. This concept may be a reasonable approach, however it can not consider failure modes appropriately. Moreover, column design strength diagram show an abrupt change at a low level of axial load, which does not seem to be reasonable. This research compares the design strength determined by the strength resistance factors. As the material resistance factors for flexure and compression, 0.65 and 0.90 are proposed for concrete and steel, respectively. The design strength calculation process by applying material resistance factors addresses failure modes more effectively than by applying member strength reduction factor, and provides more resnable design strength for reinforced concrete flexural and compression members.

Evaluation of Installation Damage Factor for Geogrid with Particle Size (입도에 따른 지오그리드의 시공손상계수 산정)

  • Lim, Seong-Yoon;Song, Chang-Seop
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.3
    • /
    • pp.113-120
    • /
    • 2010
  • Reduction factor for installation damage required to calculate design strength of geogrid used in MSEW(mechanically stabilized earth wall) design is usually obtained in the field test simulating real construction condition. However, damages occurred in geogrid during backfill work are influenced by many factors such as polymer types, unit weight per area, backfill construction method and gradation of backfill material and field test considering these factors demand lots of time and costs. In this study, factors affecting installation damage are analyzed and empirical method to evaluate reduction factor for installation damage using maximum particle size in backfill material is suggested.

Demension reduction for high-dimensional data via mixtures of common factor analyzers-an application to tumor classification

  • Baek, Jang-Sun
    • Journal of the Korean Data and Information Science Society
    • /
    • v.19 no.3
    • /
    • pp.751-759
    • /
    • 2008
  • Mixtures of factor analyzers(MFA) is useful to model the distribution of high-dimensional data on much lower dimensional space where the number of observations is very large relative to their dimension. Mixtures of common factor analyzers(MCFA) can reduce further the number of parameters in the specification of the component covariance matrices as the number of classes is not small. Moreover, the factor scores of MCFA can be displayed in low-dimensional space to distinguish the groups. We propose the factor scores of MCFA as new low-dimensional features for classification of high-dimensional data. Compared with the conventional dimension reduction methods such as principal component analysis(PCA) and canonical covariates(CV), the proposed factor score was shown to have higher correct classification rates for three real data sets when it was used in parametric and nonparametric classifiers.

  • PDF

Stiffness Reduction Factor for Flat Plate Slabs (플랫 플레이트 슬래브 해석을 위한 강성감소계수 제안)

  • Park, Young-Mi;Han, Sang-Whan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.337-340
    • /
    • 2006
  • The purpose of this study is to propose the stiffness reduction factor for flat plate slabs under lateral loads. Current design code (e.g., ACI 318-05) requires considering the effects of cracks for calculating slab stiffness under lateral loads. This study collected the test results of 20 interior slab-column connections, from which stiffness reduction in each test was estimated with respect to the ratio of applied moment to cracking moment ($M_a/M_{cr}$). Based on collected data, this study proposed equations for calculating stiffness reduction with respect to $M_a/M_{cr}$. To verify the proposed equations, this study conducted the experimental test of interior slab-column connections under quasi-static cyclic loading. From the test, load-deformation curve is compared to that obtained from effective beam width method with the proposed equation for the stiffness reduction. It is shown that the effective beam width method with the proposed equation for stiffness reduction predicts accurately the test results.

  • PDF

Evaluation of CFS Tensile Strength Reduction Factor for Bending Analysis of RC Beams Strengthened with Carbon Fiber Sheets (탄소섬유시트 보강보 휨해석에 영향을 미치는 섬유시트 인장강도 감소계수 평가)

  • 윤진섭;이우철;정진환;김성도;조백순
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.359-362
    • /
    • 2003
  • Carbon fiber sheet is attractive due to its good tensile strength, resistance to corrosion, and low weight. The strengthening of concrete structures with externally bonded carbon fiber sheets is increasingly being used for repair and rehabilitation of existing structures. However CFS strengthened beams break down under the service loads. As rupture strain is not reached ultimate value, reduction of the tensile strength is recommended. This study evaluate CFS tensile strength reduction factor which is required to analyze bending moment.

  • PDF

A Study on Simultaneous Load Factor of Intelligent Electric Power Reduction System in Korea (한국의 지능형 전력동시부하율 저감시스템에 관한 연구)

  • Kim, Tae-Sung;Lee, Jong-Hwan
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.1
    • /
    • pp.24-31
    • /
    • 2012
  • This study is designed to predict the overall electric power load, to apply the method of time sharing and to reduce simultaneous load factor of electric power when authorized by user entering demand plans and using schedules into the user's interface for a certain period of time. This is about smart grid, which reduces electric power load through simultaneous load factor of electric power reduction system supervision agent. Also, this study has the following characteristics. First, it is the user interface which enables authorized users to enter and send/receive such data as demand plan and using schedule for a certain period of time. Second, it is the database server, which collects, classifies, analyzes, saves and manages demand forecast data for a certain period of time. Third, is the simultaneous load factor of electric power control agent, which controls usage of electric power by getting control signal, which is intended to reduce the simultaneous load factor of electric power by the use of the time sharing control system, form the user interface, which also integrate and compare the data which were gained from the interface and the demand forecast data of the certain period of time.

A Study on the Correlation Evaluation of Confining Pressure and Pile-Soil Interface Strength Reduction Factor Using Numerical Analysis (수치해석에 의한 지중 구속압과 말뚝-지반 경계면 강도감소계수 관계 분석)

  • Tae-Gyeom Lee;Jung-Geun Han;Gigwon Hong;Seung-Kyong You
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.1
    • /
    • pp.9-16
    • /
    • 2024
  • In order to evaluate the relationship between the ground confining pressure and the shear characteristics of the pile-soil interface, this study described the comparative results of the existing experimental results and the FEA results using the strength reduction factor. The strength reduction factor was applied to simulate the shear behavior of the pile-soil interface in finite element analysis(FEA). The analysis results showed that the maximum pullout resistance decreased due to the influence of low confining pressure, as the fines content increased. This trend was similar to the previous experimental research, and this FEA model simulated with the interface strength reduction factor was evaluated as reasonable. The analysis results of the variation in the interface strength reduction factor clearly showed that the interface strength reduction factor clearly increased at a high fines content when the confining pressure was 50kPa. However, it was found that the increase rate was low when the confining pressure was 100kPa and 150kPa. Therefore, confining pressure and fines content need to be considered in FEA to evaluate the shear behavior of the pile-soil interface.

Comparison of Dimension Reduction Methods for Time Series Factor Analysis: A Case Study (Value at Risk의 사후검증을 통한 다변량 시계열자료의 차원축소 방법의 비교: 사례분석)

  • Lee, Dae-Su;Song, Seong-Joo
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.4
    • /
    • pp.597-607
    • /
    • 2011
  • Value at Risk(VaR) is being widely used as a simple tool for measuring financial risk. Although VaR has a few weak points, it is used as a basic risk measure due to its simplicity and easiness of understanding. However, it becomes very difficult to estimate the volatility of the portfolio (essential to compute its VaR) when the number of assets in the portfolio is large. In this case, we can consider the application of a dimension reduction technique; however, the ordinary factor analysis cannot be applied directly to financial data due to autocorrelation. In this paper, we suggest a dimension reduction method that uses the time-series factor analysis and DCC(Dynamic Conditional Correlation) GARCH model. We also compare the method using time-series factor analysis with the existing method using ordinary factor analysis by backtesting the VaR of real data from the Korean stock market.

Numerical investigation of web crippling strength in cold-formed stainless steel lipped channels with web openings subjected to interior-two-flange loading condition

  • Yousefi, Amir M.;Uzzaman, Asraf;Lim, James B.P.;Clifton, G. Charles;Young, Ben
    • Steel and Composite Structures
    • /
    • v.23 no.3
    • /
    • pp.363-383
    • /
    • 2017
  • In cold-formed stainless steel lipped channel-sections, use of web openings for service purposes are becoming increasingly popular. Web openings, however, result in the sections becoming more susceptible to web crippling. This paper presents a finite element investigation into the web crippling strength of cold-formed stainless steel lipped channel-sections with circular web openings under the interior-two-flange (ITF) loading condition. The cases of web openings located centred and offset to the bearing plates are considered in this study. In order to take into account the influence of the circular web openings, a parametric study involving 2,220 finite element analyses was performed, covering duplex EN1.4462, austenitic EN1.4404 and ferritic EN1.4003 stainless steel grades. From the results of the parametric study, strength reduction factor equations are proposed. The strengths obtained from reduction factor equations are first compared to the strengths calculated from the equations recently proposed for cold-formed carbon steel lipped channel-sections. It is demonstrated that the strength reduction factor equations proposed for cold-formed carbon steel are unconservative for the stainless steel grades by up to 17%. New coefficients for web crippling strength reduction factor equations are then proposed that can be applied to all three stainless steel grades.