• Title/Summary/Keyword: reduction facilities

Search Result 928, Processing Time 0.026 seconds

Analysis of Runoff Reduction Effect and Rainfall Intensity-Duration Time of Permeable Block Facility (투수블록시설의 유출저감효과 분석 및 강우강도-지속시간 관계 분석)

  • Han, Sangyun;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • Non-point pollution adversely affects the water system and its influence is increasing. In order to manage such nonpoint source pollution, the government has conducted studies on LID (Low Impact Development) facilities and various efficiency evaluations. In this study, the actual installed permeable block facility among the various LID facilities was analyzed the effluent reduction rate, the residual rainfall analysis, the runoff duration time and the reduction rate of the maximum inflow and outflow for the rainfall runoff control and the results were compared the other facilities. The analysis results show that the reduction efficiency is high in order of impermeable block, filter type permeable block, and clearance type permeable block, and the graph showing the relationship between the rainfall intensity and the runoff duration time is presented. This graph can be helpful in the design of facilities such as the facility capacity selection according to the reproduction period of the permeable block facility similar to this.

Quantification of Flood Reduction Effect of Small Stormwater Detention Facilities by NRCS Curve Number (유출곡선지수를 이용한 소규모 저류시설의 유출저감효과 정량화)

  • Yoo, Chul-Sang;Kim, Kyoung-Jun;Park, Min-Kyu;Yoon, Jeong-Su
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.109-118
    • /
    • 2010
  • This study quantified the flood reduction effect of small stormwater detention facilities by the NRCS curve number. The modified rational equation was used to calculate the inflow volume into the detention facilities. The NRCS curve number in the cases w/ and w/o storage facility was calculated with respect to the rainfall characteristics(rainfall frequency, duration) and the size of storage facilities. Finally, diagrams showing the curve number reduction rate versus the size of storage facility were developed. The diagrams can be used to evaluate the flood reduction effect of storage facility reasonably and efficiently when estimating the optimal location and size of storage facility. The results based on the methodology propsed in this study were also compared with those of previous study for their validation.

Characteristics of Roadside Non-point Pollution and Applicability of Reduction Facilities in Paldang Water Source Protection Zone (팔당 상수원 보호구역내 도로비점오염의 특성 및 저감시설의 적용성 연구)

  • Cho, Hye Jin;Song, Meeyoung
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.4
    • /
    • pp.294-299
    • /
    • 2020
  • Based on the combined results of field surveys and analyses of the road structure and traffic flow, we propose a new plan for reducing roadside non-point pollution in the Paldang Water Source Protection Zone. The results show that the soil surrounding the roads in Paldang is highly permeable, which mitigates the need for filtration facilities. Roads flanked by steep slopes are found to facilitate the reduction of non-point roadside pollution through vegetation and soils along road slopes without the need for pollution reduction facilities. These results highlight the need for a flexible roadside non-point pollution reduction plan for roadside non-point pollution, which can be tailored to compliment relevant regulations and design standards after analyzing the characteristics of the target road.

Effects on the Vehicle Running Speed Analysis according to the Speed Reduction Road Facilities (속도저감형 시설이 차량 주행 속도에 미치는 영향 분석)

  • Kang, Soochul;Yoo, Soonduck;Cho, Gyucheol
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.158-170
    • /
    • 2016
  • It has been applied several ways in order to prevent traffic accidents and speed management on the road which is one of very important factors to prevent accidents. In this study, it is analyzed whether the facility such as the flashing and crosswalk, speed cameras and intermittent warning signs affect on a driving deceleration or not. It has been shown that the flashing and crosswalk and speed cameras except intermittent warning signs play a role of reducing the driving speed. The result showed that these traffic safety facilities help to improve the average speed as well as velocity distribution which was derived by the speed deviation even if there were the difference between facilities. Speed limit display does not affect the deceleration of the driver. Therefore, it was founded in this research that there were the driving speed reduction effect due to the facilities on the road. In order to control the driving speed on the road, it is necessary to install facilities with appropriate location and spacing on the road. In addition, place that turns out suppressed speeding through speed management also are required adequate facilities such as speed cameras.

Integrated Solid Waste Management for the Environmentally Sound and Sustainable Development (환경적으로 지속가능한 개발을 위한 폐기물의 통합적 관리 방안)

  • Hong, Sang-Pyo;Nam, Kie-Chang
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.1
    • /
    • pp.87-98
    • /
    • 2000
  • The costs of solid waste management have continued to increase. Stricter environmental regulations have been applied to waste management units. Future integrated solid waste management should be balanced between source reduction, recycling, energy recovery, and land disposal. To achieve more balanced solid waste management programs, more local governments must adopt diversion and recycling goals and finance to meet those goals. The hierarchy of integrated solid waste management must be enforced in a manner that is flexible enough to allow local governments to implement waste management facilities that match the communities' ability to pay for them. In establishing a hierarchy of integrated solid waste management, local governements have difficulties in implementing source reduction and recycling because of a lack of local control and inability to pay for new facilities. Integrated solid waste management involves selecting compatible options for facilities to manage the collection, recovery of energy and materials(transformation), and disposal of solid wastes efficiently. Waste Collection, transformation, and disposal must support source reduction and recycling activities.

  • PDF

A Study on Thermal Satisfaction of Domestic Heat Wave Reduction Facilities (국내 폭염 저감 시설의 온열 만족도에 대한 연구)

  • Jun, Yong-Joon;Park, Lyool;Park, Kyung-Soon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • As abnormal climates occur due to the increase in greenhouse gases at home and abroad, various problems such as human casualties, crop damage, energy depletion, and economic loss due to heat diseases, which are one of the extreme climate phenomena, are following one after another. In response, the government has established the 'Climate Crisis Response Special Committee' since 2018, when it recorded the greatest damage in history due to heat waves, and has been carrying out budget formation and reform of laws and systems every year to respond to heat waves. However, in relation to the heat wave damage reduction facility that is being expanded with a large budget, there is no prior research related to the degree of heat loss due to the use of the facility, the difference in effects between specific groups, and the economic effect that comes back compared to the invested budget. Therefore, from a midto long-term perspective, it is expected that it will be difficult to establish a clear direction for policy making. Therefore, in this study, representative facilities were selected according to the principle of heat reduction among the currently expanded heat damage reduction facilities, and a questionnaire survey was conducted for users of each reduction facility (waterfall, awning, pond, and elastic pavement). Accordingly, the change in the sense of heat according to the use of the heat damage reduction facility was checked, and the change in the sense of heat according to the group characteristics (gender, age, metabolic rate) was analyzed to examine the characteristics of the relationship between the facility and the users.

An Experimental Study on Improvement of the Effect for Runoff Reducing Facilities Using Infiltration (침투형 우수유출 저감시설의 저감효과 개선에 관한 실험 연구 : 누가침투량 분석에 의한 침투-저류시스템 제안)

  • Im, Janghyuk;Song, Jaiwoo;Park, Youngjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.4
    • /
    • pp.5-13
    • /
    • 2009
  • The runoff-reducing facilities using infiltration was considered for the sustainable and sound water management. However, for practical utilization, many problems are attended and therefore effort on improvements are required. In this study, methods of improvement for infiltration facilities proposed by Infiltration-Storage System (ISS) and the effect of runoff reduction were analyzed by hydraulic experimental study. In order to analyze the infiltration characteristics of proposed runoff reduction facilities in this study, it was applied to various rainfall condition and surface material considering development and urbanization influences. As a results of hydraulic model experiment, Infiltration-Storage System (ISS) made addition to effect of reduction by lower layer of accumulative infiltration quantities. And then as rainfall-intensity was increased, accumulative infiltration rates were increased in this study. Thus, Infiltration-Storage system (ISS) was more efficient than existing runoff reduction facilities because of increasing infiltration rate. Such a result was guaranteed application of ISS as runoff-reducing facilities. Therefore, ISS is expected to be capable for practical application if subsequent research for improvements are followed. Additionally, results of this study are expected to provide fundamental research data on infiltration facilities.

  • PDF

Reduction Method for the Leisure Facilities under The Theater (상부층 레저 시설에 의한 하부층 영화관 소음 진동 저감 대책)

  • Ryu, KukHyun;Park, HaeDong;Lee, YongHoon;Kim, SunMyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.478-480
    • /
    • 2014
  • In this paper, Evaluate the effects of the lower layer of sensitive facilities against vibration and noise cinemas at the time of installation to the leisure facilities of the building of new and proposed mitigation measures for them.

  • PDF

A Study on the Installation Time and Method of Soundproofing Facilities According to Tunnel Blasting Work (터널발파작업에 따른 방음시설의 설치시기와 방법에 대한 고찰)

  • Won, Yeon-Ho;Son, Young-Bok;Jeong, Jai-Hyung
    • Explosives and Blasting
    • /
    • v.25 no.1
    • /
    • pp.1-14
    • /
    • 2007
  • A blasting noise generated by blasting work, which is a kind of shock-noise, influences the human body. A civil appeal due to blasting noise causes work discontinuance and downsizing of a blasting scale. Most of soundproof facilities for reducing a blasting noise is installed at each working spot by itself and the degree of a noise reduction is very low. The aim of this study is to recommend a technology on noise reduction considering the method and material of soundproof facilities. As the first study step to acquire basic data, investigations on the installation time, installation method, and material of the soundproof facilities have been done at about 20 tunnel work spots such as railroad tunnel, road tunnel, tunnel for electric power.

A Study on the Calculation of Evacuation Capacity for the Development of Korean Life Safety Standards for Medical facilities (의료시설의 한국형 인명안전기준개발을 위한 피난용량 산정에 관한 연구)

  • Choi, Yun-Ju;Kim, Yun-Seong;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.92-93
    • /
    • 2021
  • In the case of medical facilities, the evacuation time is delayed due to the decrease in the number of people in the hallway and exits due to the increase in the width of evacuation by using mobile beds, wheelchairs, crutches, etc. Accordingly, it is considered to secure evacuation capacity to reduce evacuation time according to corridor width and exit width. Accordingly, we would like to compare the standards related to the evacuation capacity of medical facilities in Korea and NFPA, derive differences, and use evacuation simulations to compare evacuation times according to changes in corridor width and exit width. In Korea, it is calculated based on the floor area by use, but in the case of NFPA 101, the number of evacuation routes, stair width, corridor exit width, and two-way door width was stipulated depending on the number of people. Using evacuation simulation, efficient evacuation capacity is calculated according to the reduction of evacuation time by changing the width of the hallway, changing the width of the exit, the width of the corridor, and the width of the exit. The evacuation simulation is intended to be used to secure evacuation safety of domestic medical facilities by calculating the effective evacuation time reduction by changing the width of the hallway and exit.

  • PDF