• Title/Summary/Keyword: reduction effect

Search Result 11,248, Processing Time 0.04 seconds

Stiffness Reduction Effect of Vertically Divided Reinforced Concrete Shear Walls Under Cyclic Loading (반복하중을 받는 수직분할된 철근콘크리트 전단벽의 강성저감효과)

  • Hwangbo, Dong-Sun;Son, Dong-Hee;Bae, Baek-Il;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.103-110
    • /
    • 2022
  • The purpose of this study is to experimentally evaluate the stiffness and strength reduction according to the reinforcing bar details of the vertically divided reinforced concrete shear walls. To confirm the effect of reducing strength and stiffness according to vertical division, four real-scale specimens were fabricated and repeated lateral loading tests were performed. As a result of the experiment, it was confirmed that the strength and stiffness were decreased according to the vertical division. In particular, as the stiffness reduction rate is greater than the strength reduction rate, it is expected that safety against extreme strength can be secured when the load is redistributed according to vertical division. As a result of checking the crack pattern, a diagonal crack occurred in the wall subjected to compression control among the divided walls. It was confirmed that two neutral axes occurred after division, and the reversed strain distribution appeared in the upper part, showing the double curvature pattern. In future studies, it is necessary to evaluate the stiffness reduction rate considering the effective height of the wall, to evaluate additional variables such as wall aspect ratio, and to conduct analytical studies on various walls using finite element analysis.

Effects of Combination of Danggwibohyeol-tang Herbal-acupuncture on Anemic Rats (배합비율(配合比率)에 따른 당귀보혈탕(當歸補血湯) 약침(藥鍼)이 빈혈백서(貧血白鼠)에 미치는 영향(影響))

  • Jin Jae-Do;Kim Yun-Hong;Jung Tae-Young;Seo Jeong-Chul;Leem Seong-Cheol;Han Sang-Won
    • Korean Journal of Acupuncture
    • /
    • v.20 no.2
    • /
    • pp.77-92
    • /
    • 2003
  • Objective; This study was investigated to test the anti-anemic effects of Danggwibohyeol-tang for herbal acupuncture on rat with anemia induced by phenylhydrazine according to composition ratio. Methods; Danggwibohyeol-tang herbal-acupuncture was administered into Kyoksu(膈兪穴, BL17) and RBC, Hemoglobin, Hematocrit, MCV, MCH, MCHC, RDW, platelet, MPV, PDW, indirect bilirubin and lactate dehydrogenase were tested. Results; The obtained results are summarized as follows: (1) In control group RBC was significantly reduced in comparison with normal group. And in Danggwibohyeol-tang group A, B, C there was significant inhibitory effect on reduction in comparison with control group. The effect of Danggwibohyeol-tang group C was similiar to that of Danggwibohyeol-tang group B and was higher than that of Danggwibohyeol-tang group A. (2) In control group hemoglobin was significantly reduced in comparison with normal group. And in Danggwibohyeol-tang group A, B, C there was significant inhibitory effect on reduction in comparison with control group but there was no significant difference between Danggwibohyeol-tang group A, B, C. (3) In control group hematocrit was significantly reduced in comparison with normal group. And in Danggwibohyeol-tang group A, B, C there was significant inhibitory effect on reduction in comparison with control group. The effect of Danggwibohyeol-tang group C was higher than that of Danggwibohyeol-tang group A or B. (4) In case of MCV, MCH, MCHC and RDW there was no significant anti-anemic effect. (5) Danggwibohyeol-tang group significantly inhibited the growth of platelet. In case of Danggwibohyeol-tang A and B group there was more inhibitory effect than Danggwibohyeol-tang C group but there was no significant difference between Danggwibohyeol-tang A and B group. (6) In case of MPV, PDW and indirect bilirubin there was no significant difference between Danggwibohyeol-tang group and control group. (7) Danggwibohyeol-tang group significantly inhibited the growth of lactate dehydrogenase. In case of Danggwibohyeol-tang C group there was more inhibitory effect than Danggwibohyeol-tang B group and Danggwibohyeol-tang B group showed more inhibitory effect than Danggwibohyeol-tang A group. Conclusion; From above results Danggwibohyeol-tang for herbal acupuncture showed significant anti-anemic effect in some parameters. Further study is needed for the effect of Danggwibohyeol-tang according to different composition ratio.

  • PDF

An Analysis of Thermal Environment Change according to Green Roof System (옥상녹화 조성에 따른 열환경 변화분석)

  • Park, Ji-Young;Jung, Eung-Ho;Kim, Dae-Wuk;Cha, Jae-Gyu;Shimizu, Aki
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.100-103
    • /
    • 2009
  • The impermeable area on the surface of city has been increased as buildings and artificial landcover have continually been increased. Urban development has gradually decreased the green zone in downtown and alienated the city from the natural environment on outskirt area devastating the natural eco system. There arise the environmental problems peculiar to city including urban heat island phenomenon, urban flood, air pollution and urban desertification. As one of urban plans to solve such problems, green roof system is attracting attentions. The purpose of this study was to investigate the heat reduction effect according to the development of green roof system and to quantify the heat reduction effect by analyzing through simulation the heat environment before and after green roof system. For thermal environment analysis, Thermo-Render 3.0 was used that was developed by Tokyo Industrial College to simulate. The simulation showed that the heat island index before and after the development of tree-planting on rooftop changed maximum $0.86^{\circ}C$ and the surface temperature changed about $20^{\circ}C$. Only with lawn planting, heat reduction effect was great and it means that the green roof system in low-management-light-weight type is enough to see effect. The simulation identified that only lawn planting for green rooftop brought such difference and could lower the heat island index at a narrow area. It is judged that application of green roof system to wider areas might relieve urban heat island phenomenon positively.

  • PDF

Effect of pH in 3.5% NaCl aqueous solution and ferrite grain size on corrosion fatigue fracture of dual phase steel (複合組織鋼의 부식피로파괴에 미치는 3.5% NaCl水溶液의 pH와 母相粒徑의 效果)

  • 오세욱;강호민
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.6
    • /
    • pp.867-876
    • /
    • 1987
  • Corrosion fatigue fracture with change in the grain size of M.E.F. dual phase steel is investigated in 3.5% NaCI aqueous solution at pH 2, 4, 6, 9, and 11. Generally speaking, decrease in corrosion fatigue life is strongly dependent on decrease in pH and slightly on the grain size. For the B material with the big grain size, the fatigue life is small due to its large reduction ratio of corrosion fatigue life. The influence of grain size on the reduction ratio of corrosion fatigue life is large at pH 11-6. Whi9le at pH 4-2 the reduction ratio of corrosion fatigue life only depends on the corrosion effect. The larger grain size and the lass pH result in the greater influence on corrosion fatigue crack propagation rate. As pH decreases, the plateau portion in the crack propagation rate curves of the B material are distinct. Crack propagation rate curves become slow down at high .DELTA.K range because crack closure effect by minute corrosion products inside crack causes the oxidation corrosion action less effective for a certain period of time. In A material with small grain size, fatigue life is increased in proportion with increase of martensite intergranular which brings forth restraining the crack propagation decreases crack propagation rate. Corrosion pit which is created in the surface of specimen is found at pH 6,4 and 2 which is noticeable and the unevenness of the surface of the specimen becomes severe as pH decreases. The unevenness of corrosion fatigue fracture surface is severe as the effect of pH increases i.e. as pH decreases. In proportion with increase in the grain size and decrease in pH, the aspect of brittle fracture becomes evident.

A study on Traffic Noise control by the Environmental facilities around Roadway (도로연변 환경시설에 의한 교통소음 저감방안에 관한 연구)

  • Sul Jeung Min;Chung Yong
    • Journal of environmental and Sanitary engineering
    • /
    • v.3 no.2 s.5
    • /
    • pp.43-60
    • /
    • 1988
  • This study was carried out to determine traffic noise level and analyze noise reduction effects of various sound protection facilities in the area of Seoul, Inch'on, Songchoo and Seoul- Busan Expressway from March to Octover, 1987. The results were as follows; 1. As compared with the environmental standards and the traffic noise level in heavy noise areas, traffic noise levels observed were shown in higher than environmental standards. The noise levels in Seoul were determined at 12.8-18.2 dB(A) in daytime and 19.0-26.9 dB (A) in nighttime. And incase of inch'on, it were 6.7-9.6 dB(A) in daytime, 7.9-18.9 dB(A) in nighttime, respectively. 2. The environmental noise level observed in the backside of protection facilities, such as apartment, soundproof barrier and houses, which were constructed in paralled to the road was lower about 3-5 dB(A) than perpendicular to theroad. Noise recuction effect of upper stairs in apartment was higher than lower stairs. 3. The predicted noise level obtained from the equation $({\triangle}L\;=\; -10\;log\;(^{I'1}/Ii)\;was\;\pm\;1dB$ (A) and the correlation coefficient (r) was 0.923. 4. The noise reduction effect in backside of apartment was measured at on sites and predicted by total noise loss equation. The predicted noise level was 60.9 dB(A) and the measured level was 60.6 dB(A), respectively. 5. The narrow width landscape less than 10m width was almost no effect for the protection of traffic noise. According to the synthesis of the above results, the noise level of the road was exceeding mostly the environmental standard in the heavy traffic areas. The counterplan should be set as well. The insulation of noise protection facilities were effective by the location with near distance from the road edge. The reduction effect of double window in apartment was represented so much. The prediction model could be applied to estimate the noise levels in the roadside as well as the effectiveness for the noise protection facilities.

  • PDF

Design of 3-D resonator for improvement of interference in ETCS (ETCS 신호 간섭 개선을 위한 3-D 공진기 설계)

  • Kim Ho-Yong;Lee Hong-Min
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.9 s.351
    • /
    • pp.99-104
    • /
    • 2006
  • In this paper, the conventional 2 dimensional metamaterial structure has degeneration of shielding characteristic in cross polarization effect. The proposed 3-D resonator is designed for reduction of cross polarization effect. The proposed 3-D resonator using LTCC consists of 2-D parallel resonators on X-axis, Y-axis and Z-axis. The 2-D parallel resonator consists of two plate and one via. When the co-polarization electric filed is excited, the resonance frequency of 3-D resonator is 5.024GHz. The stop bandwidth is 19MHz. When the cross-polarization electric field is excited, the resonance frequency of 3-D resonator is 4.825GHz. The stop bandwidth is 19MHz. The proposed 3-D resonator achieve reduction of cross-polarization effect. The concrete consists of proposed 3-D resonator and absorbtion materials. The concrete will be applied for reduction or interference signal of ETCS(Electric Toll collection system).

Investigation on spanwise coherence of buffeting forces acting on bridges with bluff body decks

  • Zhou, Qi;Zhu, Ledong;Zhao, Chuangliang;Ren, Pengjie
    • Wind and Structures
    • /
    • v.30 no.2
    • /
    • pp.181-198
    • /
    • 2020
  • In the traditional buffeting response analysis method, the spanwise incomplete correlation of buffeting forces is always assumed to be same as that of the incident wind turbulence and the action of the signature turbulence is ignored. In this paper, three typical bridge decks usually adopted in the real bridge engineering, a single flat box deck, a central slotted box deck and a two-separated paralleled box deck, were employed as the investigated objects. The wind induced pressure on these bridge decks were measured via a series of wind tunnel pressure tests of the sectional models. The influences of the wind speed in the tests, the angle of attack, the turbulence intensity and the characteristic distance were taken into account and discussed. The spanwise root coherence of buffeting forces was also compared with that of the incidence turbulence. The signature turbulence effect on the spanwise root coherence function was decomposed and explained by a new empirical method with a double-variable model. Finally, the formula of a sum of rational fractions that accounted for the signature turbulence effect was proposed in order to fit the results of the spanwise root coherence function. The results show that, the spanwise root coherence of the drag force agrees with that of incidence turbulence in some range of the reduced frequency but disagree in the mostly reduced frequency. The spanwise root coherence of the lift force and the torsional moment is much larger than that of the incidence turbulence. The influences of the wind speed and the angle of attack are slight, and they can be ignored in the wind tunnel test. The spanwise coherence function often involves several narrow peaks due to the signature turbulence effect in the high reduced frequency zone. The spanwise coherence function is related to the spanwise separation distance and the spanwise integral length scales, and the signature turbulence effect is related to the deck-width-related reduced frequency.

Organ Dose Assessment of Nuclear Medicine Practitioners Using L-Block Shielding Device for Handling Diagnostic Radioisotopes (진단용 방사성동위원소 취급 시 L-block 차폐기구 사용에 따른 핵의학 종사자의 장기 선량평가)

  • Kang, Se-Sik;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.49-55
    • /
    • 2017
  • In the case of nuclear medicine practitioners in medical institutions, a wide range of exposure dose to individual workers can be found, depending on the type of source, the amount of radioactivity, and the use of shielding devices in handling radioactive isotopes. In this regard, this study evaluated the organ dose on practitioners as well as the dose reduction effect of the L-block shielding device in handling the diagnostic radiation source through the simulation based on the Monte Carlo method. As a result, the distribution of organ dose was found to be higher as the position of the radiation source was closer to the handling position of a practitioner, and the effective dose distribution was different according to the ICRP tissue weight. Furthermore, the dose reduction effect according to the L-block thickness tended to decrease, which showed the exponential distribution, as the shielding thickness increased. The dose reduction effect according to each radiation source showed a low shielding effect in proportion to the emitted gamma ray energy level.

Empirical Analysis of the Effect of EU ETS on the CO2 Emission (유럽공동체 배출권거래제 도입 효과에 대한 실증분석)

  • Kim, Hyun;Lee, Gwanghoon
    • Environmental and Resource Economics Review
    • /
    • v.19 no.4
    • /
    • pp.875-896
    • /
    • 2010
  • Using the difference in differences (DID) estimation method, this paper analyzes the effect of European Union's Emission Trading Scheme (EU ETS) on the reduction of per capita $CO_2$ emission among the twenty five participating countries. For this, the panel dataset of forty two European countries for the period 1990~2007 is constructed. Special attention is paid to the bias of the standard errors in the DID estimation due to the presence of serial correlation in the error terms. The results shows quite a robust effect of EU ETS on the reduction of per capita $CO_2$ emission among the participating countries regardless of the calculation methods of standard errors. The results also shows that the increased implicit tax rate on energy has a robust effect on the reduction of per capita $CO_2$ emission. On the contrary, the estimation results regarding the effects of per capita GDP and population density on the per capita $CO_2$ emission seem inconsistent. In particular, the environmental Kuznets curve is not statistically supported with the use of robust standard errors.

  • PDF

The Effect of Obesity-Related Quality of Life on selecting a Goal for Weight Management in Overweight and Obese Patients (과체중 여성 환자들에서 비만 관련 삶의 질이 목표체중 설정에 미치는 영향)

  • Chun, Min Young
    • Korean Journal of Community Nutrition
    • /
    • v.20 no.4
    • /
    • pp.281-290
    • /
    • 2015
  • Objectives: Obesity is known to influence physical and mental health as well as the general quality of life. The aim of this study was to evaluate the effect of obesity related quality of life on selecting a goal for weight management in overweight and obese female patients. Methods: A total of 140 overweight or obese (Body mass index $23kg/m^2$) female outpatients aged ${\geq}20$ and ${\leq}60$ years from one clinic participated in this study. Patients' desired weight (goal weight, ideal weight, satisfactory weight, acceptable weight and disappointed weight) and obesity related quality of life measures were evaluated. Univariate and multivariate analysis were performed to evaluate the effect of obesity related quality of life on goal weight reduction (%) and goal body mass index (BMI). Results: Mean BMI of overweight group, mild obesity group and severe obesity group were $62.0{\pm}4.8kg$, $68.5{\pm}5.5kg$ and $83.5{\pm}9.6kg$, respectively. Mean weight loss expectations of the three groups were $16.4{\pm}4.7%$, $19.5{\pm}5.3%$ and $30.2{\pm}6.8%$, respectively and goal weight was significantly different among the three groups. Severe obesity group had a lower total quality of life score including physical, work-related, daily living domains than overweight or mild obesity groups. In univariate and multivariate regression analysis, psychosocial domain of quality of life had an effect on goal weight reduction (%) and goal BMI. Conclusions: The results of this study demonstrated that the obese patients with poorer quality of life and psychosocial health tended to choose higher goal weight reduction and lower goal BMI.