• 제목/요약/키워드: reduction coefficient

검색결과 1,310건 처리시간 0.03초

산화물 환원공정에 의해 제조된 Bi2Te2.7Se0.3 분말의 열전특성 (Thermoelectric Properties of Bi2Te2.7Se0.3 Powder Synthesized by an Oxide-Reduction Process)

  • 박배건;이길근;김우열;하국현
    • 한국분말재료학회지
    • /
    • 제18권5호
    • /
    • pp.437-442
    • /
    • 2011
  • The present study focused on the synthesis of Bi-Te-Se-based powder by an oxide-reduction process, and analysis of the thermoelectric properties of the synthesized powder. The phase structure, chemical composition, and morphology of the synthesized powder were analyzed by XRD, EPMA and SEM. The synthesized powder was sintered by spark plasma sintering. The thermoelectric properties of the sintered body were evaluated by measuring its Seebeck coefficient, electrical resistivity, and thermal conductivity. $Bi_2Te_{2.7}Se_{0.3}$ powder was synthesized from a mixture of $Bi_2O_3$, $TeO_2$, and $SeO_2$ powders by mechanical milling, calcination, and reduction. The sintered body of the synthesized powder exhibited n-type thermoelectric characteristics. The thermoelectric properties of the sintered bodies depend on the reduction temperature. The Seebeck coefficient and electrical resistivity of the sintered body were increased with increasing reduction temperature. The sintered body of the $Bi_2Te_{2.7}Se_{0.3}$ powder synthesized at $360^{\circ}C$ showed about 0.5 of the figure of merit (ZT) at room temperature.

광학 현미경 영상 기반 시간 분해능이 향상된 비지역적 평균 노이즈 제거 알고리즘 가능성 연구 (Feasibility Study of Non Local Means Noise Reduction Algorithm with Improved Time Resolution in Light Microscopic Image)

  • 이영진;김지연
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.623-628
    • /
    • 2019
  • 본 연구의 목적은 시간 분해능이 향상된 비지역적 평균 (fast non local means, FNLM) 노이즈 제거 알고리즘을 모델링하여 광학 현미경 영상에서의 적용 가능성을 확인하는 것이다. 이를 위해 실제 흰쥐 (mouse)의 첫째어금니 치아를 사용하여 영상을 획득한 후 기존에 널리 사용되고 있는 노이즈 제거 알고리즘과 제안하는 FNLM 알고리즘을 각각 적용하여 비교하였다. 정량적 평가는 대조도 대 잡음비 (contrast to noise ratio, CNR), 변동계수 (coefficient of variation, COV), 그리고 최근에 개발된 no reference 기반의 방법인 natural image quality evaluator (NIQE)와 Blind/referenceless image spatial quality evaluator (BRISQUE)를 사용하였다. 결과적으로 모든 정량적 평가 인자에서 제안하는 FNLM 노이즈 제거 알고리즘이 가장 우수한 값을 나타내었다. 특히나 치아의 전체적인 형태학적 영상을 분석할 수 있는 NIQE와 BRISQUE 인자는 원본영상에 비하여 각각 1.14와 1.12배 향상됨을 확인할 수 있었다. 결론적으로 소동물 치아 광학 현미경 영상에서의 FNLM 노이즈 제거 알고리즘의 유용성 및 가능성을 증명하였다.

Changes in Facilitated Transport Behavior of Silver Polymer Electrolytes by UV Irradiation

  • Jongok Won;Yosang Yoon;Kang, Yong-Soo
    • Macromolecular Research
    • /
    • 제10권2호
    • /
    • pp.80-84
    • /
    • 2002
  • Silver species other than the silver ion were formed by UV irradiation on polymer electrolyte membranes containing silver salts and their effect on complexation behavior between the silver and olefin was investigated through the separation performance of olefin/paraffin mixtures. The ideal propylene/propane separation factor reached 350 and the separation coefficient was ca.15 due to the high loading amount of silver ions into poly(2-ethyl-2-oxazoline) (POZ) without UV irradiation. On UV irradiation either in air or under nitrogen, the silver-POZ membranes became yellow-brown initially due to the formation of colloidal silver particles, and finally black and metal-like luster. Even when Ag$^{+}$ was converted, to some extent, to Ag$^{\circ}$ by UV irradiation in air at the early stage, the separation coefficient of olefin/paraffin mixtures was maintained. This suggests that silver species other than the silver ion is active for olefin carrier for facilitated transport. Meanwhile the steady decrease of the separation coefficient was observed in the silver/POZ membranes irradiated under $N_2$. It is suggested that the reduction of silver ions in POZ goes through a different photoreduction mechanism with UV irradiation depending on the environment.t.

ALGEBRAIC CORRECTION FOR METAL ARTIFACT REDUCTION IN COMPUTED TOMOGRAPHY

  • Jeon, Kiwan;Kang, Sung-Ho;Ahn, Chi Young;Kim, Sungwhan
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제18권2호
    • /
    • pp.157-166
    • /
    • 2014
  • If there are metals located in the X-ray scanned object, a point outside the metals has its range of projection angle at which projections passing through the point are disturbed by the metals. Roughly speaking, this implies that attenuation information at the point is missing in the blocked projection range. So conventional projection completion MAR algorithms to use the undisturbed projection data on the boundary of the metaltrace is less efficient in reconstructing the attenuation coefficient in detailed parts, in particular, near the metal region. In order to overcome this problem, we propose the algebraic correction technique (ACT) to utilize a pre-reconstructed interim image of the attenuation coefficient outside the metal region which is obtained by solving a linear system designed to reduce computational costs. The reconstructed interim image of the attenuation coefficient is used as prior information for MAR. Numerical simulations support that the proposed correction technique shows better performance than conventional inpainting techniques such as the total variation and the harmonic inpainting.

Forced Convective Boiling of Refrigerant-Oil Mixtures in a Bundle of Enhanced Tubes Having Pores and Connecting Gaps

  • Park, Ji-Hoon;Kim, Nae-Hyun;Kim, Do-Young;Byun, Ho-Won;Choi, Yong-Min;Kim, Soo-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권3호
    • /
    • pp.81-87
    • /
    • 2009
  • The effect of oil on convective boiling of R-123 in an enhanced tube bundle is experimentally investigated at $26.7^{\circ}C$ saturation temperature. The enhanced tube had pores (0.23 mm diameter) and connecting gaps (0.07 mm width), which had been optimized using pure R-123. The effects of oil concentration (0 to 5%), heat flux (10 to $40\;kW/m^2$), mass velocity (8 to $26\;kg/m2^s$) and vapor quality are investigated. The oil significantly reduces the bundle boiling heat transfer coefficient. With 1% oil, the reduction is approximately 35%. Further addition of oil further reduces the heat transfer coefficient. The data are also compared with the pool boiling counterpart. The reduction in the heat transfer coefficient is smaller in a bundle (convective boiling) than in a pool (single-tube pool boiling), with larger difference at a smaller heat flux. Similar to pure R-123 case, the effects of mass velocity and vapor quality are negligible for the convective boiling of R-123/oil mixture.

유한요소해석을 통한 진동 감쇠형 와이어웨이시스템의 내진성능 검증 (Seismic Performance Evaluation of Vibration Attenuation Wireway-Pulley System Using the FE Analysis)

  • 트란 반 한;진수민;김성찬;차지현;신지욱;이기학
    • 한국공간구조학회논문집
    • /
    • 제20권4호
    • /
    • pp.185-192
    • /
    • 2020
  • A new lighting support structure composing of two-way wires and pulley, a pulley-type wireway system, was developed to improve the seismic performance of a ceiling type lighting equipment. This study verifies the seismic performance of the pulley-type wireway system using a numerical approach. A theoretical model fitted to the physical features of the newly-developed system was proposed, and it was utilized to compute a frictional coefficient between the wire and pulley sections under tension forces. The frictional coefficient was implemented to a finite element model representing the pulley-type wireway system. Using the numerical model, the seismic responses of the pulley-type wireway system were compared to those of the existing lighting support structure, a one-way wire system. The addition of the pulley component resulted in the increasement of energy absorption capacity as well as friction effect and showed in significant reduction in maximum displacement and oscillation after the peak responses. Thus, the newly-developed wireway system can minimize earthquake-induced vibration and damage on electric equipment.

임금 불평등 변화의 요인분해: 2006-2015년 (A Study of Factor Decomposition of Wage Ineqaulity of Korea, 2006-2015)

  • 정준호;전병유;장지연
    • 산업노동연구
    • /
    • 제23권2호
    • /
    • pp.47-77
    • /
    • 2017
  • 이 글에서는 2000년대 중반 이후 한국의 임금불평등을 지니계수의 변화와 이를 초래한 요인들의 기여도를 분석하였다. 자료와 임금 지표에 따라 추세가 달라지지만, 주당 35시간 미만 일하는 파트타임의 증가로 전체근로자 임금총액의 지니계수는 증가하는 추세를 보여주는 반면, 시간당임금 지니계수와 풀타임근로자의 임금총액 지니계수는 하락하는 추세를 나타냈다. 파트타임 증가가 임금총액 기준의 불평등은 높였지만, 파트타임의 시간당임금 증가는 시간당임금 기준의 불평등을 낮추었다. 풀타임 노동자만을 대상으로, 지니계수 감소 요인을 분해한 결과, 불평등 감소에 절대적으로 기여가 큰 요인은 근속, 경력, 직종 등의 변수였고, 고용형태 변수는 불평등 감소에 미미하게 기여하는 것으로, 사업체 규모 변수는 불평등을 오히려 높이는 것으로 나타났다. 업종이나 연령, 교육 등의 변수는 불평등 변화에 유의미한 크기의 기여를 하지 못한 것으로 분석되었다. 여기에는 장기근속과 관리전문직종에 대한 임금프리미엄의 감소와 대규모사업체의 임금프리미엄 증가 등이 작용한 것으로 분석되었다.

주기적 회전을 이용한 원봉 후류의 되먹임 제어 (Feedback Control of a Circular Cylinder Wake with Rotational Oscillation)

  • 백승진;성형진
    • 대한기계학회논문집B
    • /
    • 제26권9호
    • /
    • pp.1234-1240
    • /
    • 2002
  • A new feedback control law is proposed and tested for suppressing the vortex shedding from a circular cylinder in a uniform flow. The lift coefficient ( $C_{L}$) is employed as a feedback control signal and the control forcing is given by a rotational oscillation of the cylinder. The influence of the feedback transfer function on the $C_{L}$ reduction is examined. The main rationale of the feedback control is that a feedback control forcing is imposed at a phase which is located outside the range of lock-on. By applying the feedback control law, $C_{L}$ is reduced significantly. Furthermore, the reduction mechanism of $C_{L}$ is analyzed by showing the vortex formation modes with respect to the forcing phase.e.ase.e.

천음속유동에서 초임계익형 후연확대수정의 영향 (Effect of Divergent Trailing Edge Modification of Supercritical Airfoil in Transonic Flow)

  • 유능수
    • 산업기술연구
    • /
    • 제17권
    • /
    • pp.183-189
    • /
    • 1997
  • The computation of the flow around a supercritical airfoil with a divergent trailing edge(DTE) modification(DLBA 243) is compared to that of original supercritical airfoil(DLBA 186). For this computation, Reynolds-Averaged Navier-Stokes equations are solved with a linearized block implicit ADI method and a mixing length turbulence model. Results show the effects of the shock and separated flow regions on drag reduction due to DTE modification. Results also show that DTE modification accelerates the boundary layer flow near the trailing edges which has an effect similar to a chordwise extension that increases circulation and is consistent with the calculated increase in the recirculation region in the wake. Airfoil with DTE modification achieves the same lift coefficient at a lower incidence and thus at a lower drag coefficient, so that lift-to-drag ratio is increased in transonic cruise conditions compared to the original airfoil. The reduction in drag due to DTE modification is associated with weakening of shock strength and delay of shock which is greater than the increase in base drag.

  • PDF

증발기의 설계조건에서 공기측 열전달계수 및 압력강하 산출 (Evaluation of Air-side Heat Transfer and Friction Characteristics on Design Conditions of Evaporator)

  • 김창덕;이진호
    • 설비공학논문집
    • /
    • 제15권12호
    • /
    • pp.1007-1017
    • /
    • 2003
  • An experimental study on the air-side pressure drop and heat transfer coefficient of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side heat transfer coefficients in the literature is not based on a consistent approach. This paper focuses on new method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry and wet surface heat transfer estimation in fin-tube heat exchanger having refrigerant on the tube-side. Results are presented as plots of friction f-factor and Colburn j -factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of 150∼250 kg/$m^2$s with air flows at velocity ranges from 0.3 m/s to 0.8 m/s.