• Title/Summary/Keyword: reduced loss

Search Result 2,745, Processing Time 0.036 seconds

A Weighted Scheduling Mechanism to Reduce Multicast Packet Loss in IPTV Service over EPON

  • Kwon, Young-Hwan;Choi, Jun-Kyun;Choi, Seong-Gon;Um, Tai-Won;Jong, Sang-Gug
    • ETRI Journal
    • /
    • v.31 no.4
    • /
    • pp.469-471
    • /
    • 2009
  • This letter proposes a weighted scheduling mechanism for Internet protocol television (IPTV) to improve the loss performance of multicast transmission over an Ethernet passive optical network (EPON). We propose a new weight policy from the number of multicast receivers to proportionally allocate the downstream bandwidth of IPTV traffic. The proposed mechanism is used in an optical line terminal to decrease lost packets of favorite IPTV services because the lost multicast packets are proportional to the number of receivers. The total proportion of lost multicast packets is reduced by up to 73% in an EPON.

An experimental study for the coal particle separator in the pulverizer model with dynamic classifier (Dynamic classifier가 장착된 미분기 모델에서의 석탄 입자 분리 실험)

  • Lee, Gun-Myung;Kim, Hyuk-Je;Kim, Hyeuk-Pill;Kim, Sang-Hyeun;Ha, Jong-Kang
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.688-692
    • /
    • 2001
  • Three-dimensional experimental analyses were conducted in the pulverizer simplified isothermal model. The experimental model was constructed on a 1/3.5 scale of 500MW pulverized coal boiler. The purpose of this study is to investigate the characteristics of coal particle separator and the pressure loss in the pulverizer models with dynamic classifier. Without regards a shape of separator top, the results showed that the increase of dynamic classifier rpm was induced in finer coal particle. But the capacity of total mass per minute was reduced. Also, the increase of dynamic classifier rpm had no effect on total pressure loss, but an increase of inlet velocity was induced that the rise of total pressure loss in the pulverizer models with dynamic classifier.

  • PDF

Reduction of the bondwire parasitic effect using dielectric materials for microwave device packaging (초고주파 소자 실장을 위한 유전체를 이용하는 본딩와이어 기생 효과 감소 방법)

  • 김성진;윤상기;이해영
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.2
    • /
    • pp.1-9
    • /
    • 1997
  • For the reduction of parasitic inductance and matching of bonding wire in the package of microwave devices, we propose multiple bonding wires buried in a dielectric material of FR-4 composite. This structure is analyzed using the method of moments (MoM) and compared with the common bondwires and ribbon interconnections. The FR-4 composite is modelled by the cole-cole model which can consider the loss and the variation of the permittivity in a frequency. At 20 GHz, the parasitic reactance is reduced by 90%, 80%, 60% compared to those of a single bonding wire in air, double bonding wires in air and ribbon interconnection in air, respectively. Also, the new bondwire shows very good matching of 60.ohm characteristic impedance and has 15dB, 10dB, 5dB improvement of the return loss and 2.5dB, 0.7dB, 0.2dB improvement of the insertion loss compared to the common interconnections. This technique can minimize the parasitic effect of bondwires in microwave device packaging.

  • PDF

Zero Voltage Switched Converter with Reduced Conduction Loss of Auxiliary Switch (보조 스위치의 전도손실을 줄인 영전압 스위칭 방식의 컨버터)

  • Joung, Gyu-Bum
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.2
    • /
    • pp.131-137
    • /
    • 1999
  • New zero voltage switched(ZVS) converter in which main switch is switched at zero voltage is proposed. A resonant inductor of conventional ZVS PW converter is replaced to two small saturable inductors in order to reduce conduction loss of auxiliary switch. Therefore, the switching loss of main switch is very low, and conduction losses of the main and auxiliary switch are lowered. The ZVS and above characteristics are verified by experimental results for a 200 kHz operation.

  • PDF

Effect of Helminthiasis on Zinc Metabolism

  • Musalia, L.M.;Aggett, P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.2
    • /
    • pp.276-279
    • /
    • 2001
  • The effect of helminthiasis on zinc metabolism was monitored using endogenous $^{65}Zn$ after intraperitoneal injection of 1 g of $^{65}Zn$ as zinc chloride. In the first experiment zinc turnover was investigated in 18 male weanling rats, which were randomly divided into 3 groups. One group was infected with 73 third stage larvae of Nippostrongylus brasiliensis per gram body weight ; the other groups were the pair-fed and ad lib-fed controls. The route of loss of zinc was investigated in the second experiment with the same design using 18 animals with a lower dose of infection (33 larvae per gram body weight). The biological half life of endogenous $^{65}Zn$ was lower (p<0.05) in the infected group as compared to the controls. In the later phase of infection (9th to 16th day) there was reduced retention of $^{65}Zn$ and increased loss (p<0.05) of $^{65}Zn$ from the body though urine and faeces. It was concluded that infection of N. brasiliensis was accompanied by increased loss of endogenous Zn through faeces and urine.

Flow Characteristics of T-junction Pipe (T-합류관의 유동특성)

  • Kim, M.K.;Bae, D.S.;Kwon, O.B.;Yang, J.K.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.528-533
    • /
    • 2005
  • This paper presents the study of flows at T-junction pipe with orifices. Experiments were carried out for several flow rates, orifice sizes, and pressure differences. Numerical simulations were also done to get more data for the wide range of flow rates. Experimental results and numerical ones are in a good agreement. Due to the effect of T-junction part, the flow rates at the lateral pipe are greater than those at straight pipe for the same pressure differences. When orifices were added, the effects of T-junction part on the ratio of flow rates and the ratio of loss coefficients reduced.

  • PDF

Modeling of Flux Leakage in a Magnetic Circuit with Permanent Magnet (영구자석을 포함한 자기회로에서의 누설 자속 모델링)

  • Kim, Seung-Jong;Kim, Woo-Yeon;Lee, Jong-Min;Bae, Yong-Chae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The magnetic circuit analysis excluding flux loss and fringing effect often gives a result with unignorable error, when compared with real system. But, it is not easy to make a complete magnetic circuit model with the loss effects. This paper introduces a relatively simple method to build the model including the flux loss and fringing effect, in which the paths of leaked flux are simplified in terms of circular arcs and straight lines. After modification of the model, the error of about 36 % in maximum between the magnetic circuit analysis and FEM analysis is reduced to about 7 %.

Exhaust Noise Reduction of Dry Vacuum Pump (건식 진공 펌프의 배기 소음 저감)

  • Ahn, Young-Chan;Lee, Hae-Jin;Park, Sang-Gil;Lee, You-Yub;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.10
    • /
    • pp.950-957
    • /
    • 2007
  • This paper considers acoustic characteristics of silencer within a dry vacuum pump. The main objective is to reduce noise in dry vacuum pump using the new designed silencer. First, SPL and sound intensity are measured for noise source identification and the new model silencer is designed corresponding to noise characteristics. 4-pole parameters are used to predict the transmission loss which is one of the interest characteristics of the new silencer. The calculated transmission loss is then used to change main effective factor and optimal value is selected by using design of experiment. By conducting an experiment, it is proved that the new designed silencer has reduced noise level by 6 dB(A) more than the original one.

INSERTION LOSS MEASUREMENT OF SILENCERS BY DOUBLE PAIR MICROPHONE TECHNIQUE

  • Jung, S.S.;Pu, Y.C.;Kim, M.G.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.704-709
    • /
    • 1994
  • The insertion loss is the measured change in power flux at a specified receiver, when the acoustic transmission path between it and the source is modified by the insertion of silencer element. Such measurements have clear and valid physical meaning particularly if the source impedance remains while the transmission path is altered. When the invarient condition is satisfied, the insertion loss is given by the ratio of the acoustic pressure in upstream to that in downstream of the silencer, and that of the particle velocity. The measurement is consisted of using an adaptation of the two microphone method to obtain the complex amplitude of the sound in upstream tube as well as in downstream tube of the silencer. Examples of the data, reduced and presented in terms of the pressure ratio and particle speed ratio, are compared with the theoretical calculations.

  • PDF

A study or Metallic sheath for Extra-high voltage XLPE cable (초고압 XLPE 케이블 금속 차폐층 고찰)

  • Choi, C.S.;Lee, K.J.;Chung, M.Y.;Kwon, B.I.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1652-1654
    • /
    • 1994
  • The Extra-high voltage XLPE cable is characterized by low transmission loss, large capacity, and high reliability. Conventionally, for XLPE cables of l54kV and above, aluminium sheath was used to be moisture barrier (thus preventing water tree deterioration of the insulation) and to protect cable core from physical stresses. However, as transmission capacity of the cable increases, so does the cable diameter and the corresponding aluminium sheath outer diameter and thickness. As a result, eddy-current loss in the sheath is increased, limiting the maximum current capacity of the cable itself. As an alternative to aluminium sheath, we have adopted stainless steel sheath with non-magnetic properties and a large resistivity, The new XLPE cable with stainless-steel sheath (CSZV cable) has drastically reduced eddy-current loss in the sheath.