• Title/Summary/Keyword: reduce patient dose

Search Result 286, Processing Time 0.026 seconds

Image Reconstruction of Sinogram Restoration using Inpainting method in Sparse View CT (Sparse view CT에서 inpainting 방법을 이용한 사이노그램 복원의 영상 재구성)

  • Kim, Daehong;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.655-661
    • /
    • 2017
  • Sparse view CT has been widely used to reduce radiation dose to patient in radiation therapy. In this work, we performed sinogram restoration from sparse sampling data by using inpainting method for simulation and experiment. Sinogram restoration was performed in accordance with sampling angle and restoration method, and their results were validated with root mean square error (RMSE) and image profiles. Simulation and experiment are designed to fan beam scan for various projection angles. Sparse data in sinogram were restored by using linear interpolation and inpainting method. Then, the restored sinogram was reconstructed with filtered backprojection (FBP) algorithm. The results showed that RMSE and image profiles were depended on the projection angles and restoration method. Based on the simulation and experiment, we found that inpainting method could be improved for sinogram restoration in comparison to linear interpolation method for estimating RMSE and image profiles.

Postoperative radiotherapy for endometrial cancer

  • Choi, Eun Cheol;Kim, Jin Hee;Kim, Ok Bae;Byun, Sang Jun;Park, Seung Gyu;Kwon, Sang Hoon
    • Radiation Oncology Journal
    • /
    • v.30 no.3
    • /
    • pp.108-116
    • /
    • 2012
  • Purpose: To investigate the prognostic factors and effectiveness of postoperative radiotherapy alone for endometrial carcinoma. Materials and Methods: Sixty four patients with stage I-III endometrial cancer (EC) treated with postoperative radiotherapy alone between January 1989 and December 2008 at the Keimyung University Dongsan Medical Center were chosen for the present study. Typically, total hysterectomy, salpingo-oophorectomy and lymphadenectomy were performed on the patient's pelvis. Total dose from 50.4 Gy to 63 Gy was irradiated at pelvis or extended field. Thirteen patients were treated with Co-60 or Ir-192 intracavitary radiotherapy. Follow-up periods were from 7 to 270 months, with a median of 56 months. Results: Five year overall survival (OS) rate was 58.7%, respectively. Five year disease-free survival (DFS) rate was 59.2%, respectively. In univariate analysis for OS and DFS, stage, menopausal age, type of operation, serosal invasion, and lymph node involvement were found to be statistically significant. Histologic type was marginally significant. In multivariate analysis for OS and DFS, stage, types of operation, histologic type were also found to be statistically significant. Treatment failure occurred in 14 patients. The main pattern of failure was found to be distant metastasis. Time to distant metastasis was from 3 to 86 months (median, 12 months). There were no grade 3 or 4 complications. Conclusion: Stage, types of operation, and histologic type could be the predictive prognostic factors in patients. We contemplated postoperative radiation as effective and safe treatment method for EC. Additional treatment would be needed to reduce distant metastasis.

Accelerating Medical Image Processing on Integrated GPU Using OpenCL (OpenCL을 이용한 내장형 GPU에서의 의학영상처리 가속화)

  • Kim, Beom-Jun;Shin, Byeong-seok
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.2
    • /
    • pp.1-10
    • /
    • 2017
  • A variety of filters are applied to improve the quality of noise and low resolution medical images. This is necessary to reduce the radiation dose of the patient and to improve the utilization of the conventional spherical imaging equipment. In the conventional method, it is common to perform filtering using the CPU of the PC. However, it is difficult to produce results in real time by applying various calculations and filters to high-resolution human images using only the CPU performance of a PC used in a hospital. In this paper, we analyze the structure and performance of Intel integrated GPU in CPU and propose a method to perform image filtering using OpenCL parallel processing function. By applying complex filters with high computational complexity to medical images, high quality images can be generated in real time.

Reduction of Scattered Radiation by Air Gap Technique for High Kilovoltage Chest Roentgenography (흉부(胸部) 고관전압(高管電壓) 촬영(撮影)에 있어 Air Gap Technique를 이용한 산란선(散亂線) 경감(輕減)에 관(關)한 연구(硏究))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Youn, Chul-Ho;Lee, Sang-Suk;Lim, Han-Young;Song, Jae-Kwan
    • Journal of radiological science and technology
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 1980
  • X-ray grid is the most important means to reduce the scattered ray from patients, but alternative way is air gap technique that is another name of Groedel technique. This technique is mainly used in chest radiography. Authors performed an experimental study on the air gap technique for chest radiography and obtained the results as follows; 1. In using the high voltage air technique, scattered ray could be reduced effectively, while the percentage of scattered ray was slightly increased than conventional grid technique. 2. In film contrast, 30cm air gap technique was inferior to 12:1 grid technique and contrast improvement was increased when the object was thicker and higher voltage was used. 3. The patient exposure dose was reduced about $25{\sim}45%$ compared with conventional grid technique by air gap technique used.

  • PDF

Application of Total Variation Algorithm in X-ray Phantom Image with Various Added Filter Thickness : GATE Simulation Study (다양한 두께의 부가 여과판을 적용한 X-선 영상에서의 Total Variation 알고리즘 적용 : GATE 시뮬레이션 연구)

  • Park, Taeil;Jang, Sujong;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.773-778
    • /
    • 2019
  • Images using X-rays are essential to diagnosis, but noise is inevitable in the image. To compensate for this, a total variation (TV) algorithm was presented to reduce the patient's exposure dose while increasing the quality of the images. The purpose of this study is to verify the effect on the image quality in radiographic imaging according to the thickness of the additional filtration plate through simulation, and to evaluate the usefulness of the TV algorithm. By using the Geant4 Application for Tomographic Emissions (GATE) simulation image, the actual size, shape and material of the Polymethylmethacrylate (PMMA) phantom were identical, the contrast to noise ratio (CNR) and coefficient of variation (COV) were compared. The results showed that the CNR value was the highest and the COV the lowest when applying the TV algorithm. In addition, we can acquire superior CNR and COV results with 0 mm Al in all algorithm cases.

Development of Sensitivity-Enhanced Detector using Pixelization of Block Scintillator with 3D Laser Engraving (3차원 레이저 각인으로 블록형 섬광체의 픽셀형화를 통한 민감도 향상 검출기 개발)

  • Lee, Seung-Jae;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.313-318
    • /
    • 2019
  • To improve the sensitivity, a detector using a block scintillator was developed. In the pixelated scintillator, a reflector is located between pixels to move the light generated from the scintillator to the photosensor as much as possible, and sensitivity loss occurs in the reflector portion. In order to improve the sensitivity and to have the characteristics of the pixelated scintillator, the block scintillator was processed into a scintillator in pixel form through three-dimensional laser engraving. The energy spectra and energy resolution of each pixel were measured, and sensitivity analysis of block and pixel scintillator was performed through GATE simulation. The measured global energy resolution was 20.7%, and the sensitivity was 18.5% higher than that of the pixel scintillator. When this detector is applied to imaging devices such as gamma camera and positron emission tomography, it will be possible to shorten the imaging time and reduce the dose of patient by using less radiation source.

Developing Customized Phantom for Korean Bone Density Using 3D Printing (3D 프린팅을 이용한 한국인 골밀도 맞춤 팬텀 개발)

  • Lee, Junho;Choi, Kwan-Yong;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.223-229
    • /
    • 2019
  • In order to reduce the radiation exposure dose of the patient and to obtain accurate diagnosis results, the quality control of the diagnostic radiation generator must be conducted periodically In particular, bone density test equipment could be influenced by many factors, and it is far more important because inaccurate measurement would eventually affect the result value. However, the cross-correction phantom of DXA equipment is poorly penetrated due to lack of awareness of the industry and the high cost. Therefore, this study developed a BMD phantom using a 3D printer and Korean BMD phantom with low cost by cross analyzing Korean BMD value from The Korean National Health and Nutrition Examination Survey and evaluated it. The L1, L2, and L3 BMD values of phantoms produced with the 3D printer were measured to be $0.887{\pm}0.006g/cm^2$, $0.927{\pm}0.006g/cm^2$, and $0.960{\pm}0.005g/cm^2$, at 215 mm height and $0.882{\pm}0.011g/cm^2$, $0.914{\pm}0.005g/cm^2$, $0.933{\pm}0.008g/cm^2$ at 155 mm height displaying statistically significant relevance. The result suggests that a proper quality control and cross calibration of DXA device be possible and expected to be an essential data for various medical phantom manufacture development using 3D printer.

Preliminary Study on Natural Killer Cell Activity for Interfer-on-Gamma Production after Gamma Knife Radiosurgery for Brain Tumors

  • Park, Kawngwoo;Jeong, Sang Soon;Kim, Jung Hoon;Chung, Hyun-Tai;Lee, Eun Jung;Moon, Hyo Eun;Park, Kwang Hyon;Kim, Jin Wook;Park, Hye Ran;Lee, Jae Meen;Lee, Hye Ja;Kim, Hye Rim;Cho, Yong Hwan;Paek, Sun Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.861-867
    • /
    • 2022
  • Objective : High-dose radiation is well known to induce and modulate the immune system. This study was performed to evaluate the correlation between clinical outcomes and changes in natural killer cell activity (NKA) after Gamma Knife Radiosurgery (GKS) in patients with brain cancer. Methods : We performed an open-label, prospective, cross-sectional study of 38 patients who were treated with GKS for brain tumors, including metastatic and benign brain tumors. All of the patients underwent GKS, and blood samples were collected before and after GKS. NKA was measured using an enzyme-linked immunosorbent assay kit, to measure interferon-gamma (IFNγ) secreted by ex vivo-stimulated NK cells from whole blood. We explored the correlations between NK cell-produced IFNγ (NKA-IFNγ) levels and clinical parameters of patients who were treated with GKS for brain tumors. Results : NKA-IFNγ levels were decreased in metastatic brain tumor patients compared to those with benign brain tumors (p<0.0001). All the patients who used steroid treatment to reduce brain swelling after GKS had an NKA-IFNγ level of zero except one patient. High NKA-IFNγ levels were not associated with a rapid decrease in brain metastasis and did not increase after GKS. Conclusion : The activity of NK cells in metastatic brain tumors decreased more than that in benign brain tumors after GKS.

Assessment of risks for breast cancer in a flight attendant exposed to night shift work and cosmic ionizing radiation: a case report

  • Dong Joon Park;Sungkyun Park;Seong Won Ma;Hoekyeong Seo;Sang Gil Lee;Kyung-Eun Lee
    • Annals of Occupational and Environmental Medicine
    • /
    • v.34
    • /
    • pp.5.1-5.10
    • /
    • 2022
  • Background: Some epidemiological studies have estimated exposure among flight attendants with and without breast cancer. However, it is difficult to find a quantitative evaluation of occupational exposure factors related to cancer development individually in the case of breast cancer in flight attendants. That is, most, if not all, epidemiological studies of breast cancer in flight attendants with quantitative exposure estimates have estimated exposure in the absence of individual flight history data. Case presentation: A 41-year-old woman visited the hospital due to a left breast mass after a regular check-up. Breast cancer was suspected on ultrasonography. Following core biopsy, she underwent various imaging modalities. She was diagnosed invasive ductal carcinoma of no special type (estrogen receptor positive in 90%, progesterone receptor positive in 3%, human epidermal growth factor receptor 2/neu equivocal) with histologic grade 3 and nuclear grade 3 in the left breast. Neoadjuvant chemotherapy was administered to reduce the tumor size before surgery. However, due to serious chemotherapy side effects, the patient opted for alternative and integrative therapies. She joined the airline in January, 1996. Out of all flights, international flights and night flights accounted for 94.9% and 26.2, respectively. Night flights were conducted at least four times per month. Moreover, based on the virtual computer program CARI-6M, the estimated dose of cosmic radiation exposure was 78.81 mSv. There were no other personal triggers or family history of breast cancer. Conclusions: This case report shows that the potentially causal relationship between occupational harmful factors and the incidence of breast cancer may become more pronounced when night shift workers who work continuously are exposed to cosmic ionizing radiation. Therefore, close attention and efforts are needed to adjust night shift work schedules and regulate cosmic ionizing radiation exposure.

Initial Experience for 3-D Conformal Boost Treatments in Carcinoma of the Nasopharynx (비인강암환자에서 시행한 3차원 입체조형 방사선치료의 조기 임상결과)

  • Jang Ji-Young;Cho Moon-June;Kim Ki-Hwan;Song Chang-Joon;Kim Byoung-Kook;Kim Jun-Sang;Kim Jae-Sung
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.2
    • /
    • pp.172-176
    • /
    • 2000
  • Objectives: To improve local control and reduce toxicity, 3-D conformal radiotherapy was used as a boost the primary tumor site following fractionated radiotherapy in patients with nasopharyngeal carcinoma. Materials and Methods: Eight patients with previously untreated nasopharyngeal carcinomas were treated with 3-D conformal radiotherapy following fractionated radiotherapy from September 1998 to April 2000. All patients had biopsy confirmation of disease before radiation therapy. Stages were II in 1, III in 5, and IV in 2. Two patients received cisplatin based chemotherapy in addition to radiation therapy; induction chemotherapy in 1, concurrent chemoradiation in 1. 3-D conformal radiotherapy delivered using 6MV Linac as a boost(range 25.2-28.8Gy, median 25.7Gy) following conventionally fractionated radiotherapy(range 50.4Gy). Average total dose ranged from 75.6-79.2Gy(median 76Gy). Follow-up time was 4-21 months(median 9.6 months). Results: Seven of 8 patients were evaluated radiologically within 3 months after completion of radiation therapy. All 7 patients were seen complete remission. One of 7 patients had distant metastasis after 5 months and local failure after 7 months. The tree interval of local recurrence was ranged from 4 - 21 months(median 10.2 months). One patient without radiological evaluation got complete remission clinically. Treatment related toxicity was grade 1-3 xerostomia, dysphagia, and mucositis. During 3-D conformal radiotherapy, there was no aggravation of any toxicity. Conclusion: Although the number of patients was small and follow-up period was short, 3-D conformal radiotherapy following conventional radiotherapy improved tumor control and dose escalation without increased toxicity. Survival and late toxicity should be evaluated through long term follow-up. In addition, it is necessary to confirm the benefits of 3-D conformal radiotherapy in nasopharyngeal carcinoma with randomized trial.

  • PDF