• Title/Summary/Keyword: reduce patient dose

Search Result 286, Processing Time 0.03 seconds

Set Up and Operation for Medical Radiation Exposure Quality Control System of Health Promotion Center (건강검진센터의 의료방사선 피폭 품질관리 시스템 구축 운영 경험 보고)

  • Kim, Jung-Su;Jung, Hae-Kyoung;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT $357.9mGy{\cdot}cm$ in abdomen and pelvic CT, $572.4mGy{\cdot}cm$ in brain without CT, $55.9mGy{\cdot}cm$ in calcium score/heart CT, screening CT at $54mGy{\cdot}cm$ in chest screening CT(low dose screening CT scan), $284.99mGy{\cdot}cm$ in C-spine CT and $341.85mGy{\cdot}cm$ in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows $274.0mGy{\cdot}cm2$ and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure.

Verification of the Protective Effect of Functional Shielding Cream for the Prevention of X-ray Low-dose Exposure (X-ray 저선량 피폭방지를 위한 기능성 차폐크림의 방어 효과 검증)

  • Seon-Chil Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.497-506
    • /
    • 2023
  • In the case of radiation workers in medical institutions, radiation exposure is made for patient protection and accurate procedures, so they have a problem of low dose exposure. Low-dose radiation exposure occurs mainly in parts of the body other than the Apron area, and the most frequent place is the skin of the back of the hand. In particular, since the medical personnel's hands require senses and fine movements during the procedure, they are defenseless in the radiation exposure area and are at risk of exposure. It can solve the problem of shielding such as lead gloves, and it is difficult to use by suggesting the activity of the hand during the procedure. To solve this problem, a shielding cream capable of obtaining a functional radiation protection effect was developed and its shielding performance was compared with lead equivalent of 0.1 mmPb. In the process of manufacturing shielding cream, the shielding performance was improved by adding a defoaming process to reduce air holes to increase the density of the cream. Therefore, the shielding cream using barium sulfate as the main material has a lower shielding rate than the lead plate, and in the realm of effective energy, it is 59%, At high effective energy, a difference of about 37% was shown, indicating that there is a functional radiation protection effect. The advantage is that it can be used directly on the skin, and it is considered that it can be used before wearing surgical gloves and has a permanent protective effect.

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.

Efficacy of Lens Shielding Device to Prevent Cataract with Radiotherapy for Orbit or Ocular Adnexal Tumor (안와 및 안부속기 종양의 방사선치료에서 백내장의 예방을 위한 렌즈보호 장치의 효용성)

  • Cho, Jung-Keun;Cho, Hyun-Sang;Han, Tae-Jong
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.12
    • /
    • pp.139-144
    • /
    • 2007
  • Radiotherapy which is the most effective for orbit lymphoma has been used increasingly due to the increase of orbit or ocular adnexal tumor patients. Curative effects and convalescence have been being more satisfied thanks to remarkable development of cancer chemotherapy and medical treatments, but side effects such as cataract, dry eye and retinopathy still break out. Thus, in this study, a Lens Shielding Device (LSD hereafter) was designed to prevent occurring of cataract due to radiation therapy for orbit lymphoma and its efficacy through dosimetry were evaluated. And in this paper, its manufacturing process was also explained. LSD is composed of a cover body covering the lens and a side fixing part supporting the cover body. To measure radiation, the patient therapy conditions were simulated and the measurement of the radiation was conducted with Thermo Luminescence Detector (TLD) and Markus chamber. The average TLD value was 5.7% and the TLD value and Markus chamber value were acquired as 4.2% and 5.1% respectively at 6 mm depth where zero lens center was located. Only 1.5Gy ($300Gy{\times}\;5%$) or 5% of total 30Gy with 9 MeV electron beam is estimated to affect on patient's lens. That is smaller dose than the threshold value of cataract (2GY) or the value (5Gy) that was reported to cause cataract in clinical conditions. Thus, these findings suggest that LSD be very useful for prevention of cataract during radiotherapy for malignant lymphoma of orbit and ocular adnexa. Furthermore, it might be possible to reduce patient's discomfort caused by alien substances and to make it easier to fix the device with customized manufacturing manners.

Measurement of Respiratory Motion Signals for Respiratory Gating Radiation Therapy (호흡동조 방사선치료를 위한 호흡 움직임 신호 측정)

  • Chung, Jin-Beom;Chung, Won-Kyun;Kim, Yon-Lae;Lee, Jeong-Woo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.59-63
    • /
    • 2005
  • Respiration motion causes movement of internal structures in the thorax and abdomen, making accurate delivery of radiation therapy to tumors in those areas a challenge. Accounting for such motion during treatment, therefore, has the potential to reduce margins drawn around the clinical target volume (CTV), resulting in a lower dose to normal tissues (e.g., lung and liver) and thus a lower risk of treatment induced complications. Among the techniques that explicitly account for intrafraction motion are breath-hold, respiration gating, and 4D or tumor-tracking techniques. Respiration gating methods periodically turn the beam on when the patient's respiration signal is in a certain part of the respiratory cycle (generally end-inhale or end-exhale). These techniques require acquisition of some form of respiration motion signal (infrared reflective markers, spirometry, strain gauge, thermistor, video tracking of chest outlines and fluoroscopic tracking of implanted markers are some of the techniques employed to date), which is assumed to be correlated with internal anatomy motion. In preliminary study for the respiratory gating radiation therapy, we performed to measurement of this respiration motion signal. In order to measure the respiratory motion signals of patient, respiration measurement system (RMS) was composed with three sensor (spirometer, thermistor, and belt transducer), 4 channel data acquisition system and mobile computer. For two patients, we performed to evaluation of respiratory cycle and shape with RMS. We observed under this system that respiratory cycle is generally periodic but asymmetric, with the majority of time spent. As expected, RMS traced patient's respiration each other well and be easily handled for application.

  • PDF

Quality Assurance of Volumetric Modulated Arc Therapy for Elekta Synergy (Elekta Synergy 선형가속기를 이용한 입체적세기조절회전방사선치료(VMAT) 정도관리)

  • Shim, Su-Jung;Shim, Jang-Bo;Lee, Sang-Hoon;Min, Chul-Kee;Cho, Kwang-Hwan;Shin, Dong-Oh;Choi, Jin-Ho;Park, Sung-Ill;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.33-41
    • /
    • 2012
  • For applying the quality assurance (QA) of volumetric modulated arc therapy (VMAT) introduced in Eulji Hospital, we classify it into three different QA steps, treatment planning QA, pretreatment delivering QA, and treatment verifying QA. These steps are based on the existing intensity modulated radiation therapy (IMRT) QA that is currently used in our hospital. In each QA step, the evaluated items that are from QA program are configured and documented. In this study, QA program is not only applied to actual patient treatment, but also evaluated to establish a reference of clinical acceptance in pretreatment delivering QA. As a result, the confidence limits (CLs) in the measurements for the high-dose and low-dose regions are similar to the conventional IMRT level, and the clinical acceptance references in our hospital are determined to be 3 to 5% for the high-dose and the low-dose regions, respectively. Due to the characteristics of VMAT, evaluation of the intensity map was carried out using an ArcCheck device that was able to measure the intensity map in all directions, $360^{\circ}$. With a couple of dosimetric devices, the gamma index was evaluated and analyzed. The results were similar to the result of individual intensity maps in IMRT. Mapcheck, which is a 2-dimensional (2D) array device, was used to display the isodose distributions and gave very excellent local CL results. Thus, in our hospital, the acceptance references used in practical clinical application for the intensity maps of $360^{\circ}$ directions and the coronal isodose distributions were determined to be 93% and 95%, respectively. To reduce arbitrary uncertainties and system errors, we had to evaluate the local CLs by using a phantom and to cooperate with multiple organizations to participate in this evaluation. In addition, we had to evaluate the local CLs by dividing them into different sections about the patient treatment points in practical clinics.

Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases (두경부암 환자에 대한 선량체적 히스토그램에 따른 토모치료외 선형가속기기반 세기변조방사선치료의 정량적 비교)

  • Kim, Dong-Wook;Yoon, Myong-Geun;Park, Sung-Yong;Lee, Se-Byeong;Shin, Dong-Ho;Lee, Doo-Hyeon;Kwak, Jung-Won;Park, So-Ah;Lim, Young-Kyung;Kim, Jin-Sung;Shin, Jung-Wook;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • TomoTherapy has a merit to treat cancer with Intensity modulated radiation and combines precise 3-D imaging from computerized tomography (CT scanning) with highly targeted radiation beams and rotating beamlets. In this paper, we comparing the dose distribution between TomoTherapy and linear accelerator based intensity modulated radiotherapy (IMRT) for 10 Head & Neck patients using TomoTherapy which is newly installed and operated at National Cancer Center since Sept. 2006. Furthermore, we estimate how the homogeneity and Normal Tissue Complication Probability (NTCP) are changed by motion of target. Inverse planning was carried out using CadPlan planning system (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA). For each patient, an inverse IMRT plan was also made using TomoTherapy Hi-Art System (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Deming Way, Madson, WI 53717-1954, USA) and using the same targets and optimization goals. All TomoTherapy plans compared favorably with the IMRT plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Our results suggest that TomoTherapy is able to reduce the normal tissue complication probability (NTCP) further, keeping a similar target dose homogeneity.

  • PDF

Treatment of Intractable Cancer Pain by Stereotactic Bilateral Anterior Cingulotomy (난치성 암성 통증 제어를 위한 뇌정위적 대상회 절개술)

  • Jung, Jin Young;Chang, Jong Hee;Chang, Jin Woo;Park, Yong Gou;Chung, Sang Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.456-462
    • /
    • 2001
  • Objective : Although cingulotomy has been applied to patients with affective disorders more frequently, there are numerous reports of its use for the control of severe pain. The goal of this study was to investigate the role of stereotactic bilateral anterior cingulotomy for intractable cancer pain. Method : Between January and June, 2000, we underwent stereotactic bilateral anterior cingulotomy in 6 patients for intractable cancer pain with poor response to opioids. The patients were suffering from widespread musculoskeletal or visceral pain. We made four lesions along the two tracks on either side of the cingulate cortex. Result : In all patients, pain reliefs after cingulotomy were dramatic and immediate. Five out of six patients did not require any opioids and one patient could reduce dose of opioids. There were no deaths or serious complications related to the procedure. Conclusion : These results suggested that a bilateral anterior cingulotomy might be useful method to control intractable cancer pain associated with the widespread metastatic disease. To provide rationale of bilateral anterior cingulotomy in intractable cancer pain, the theoretical mechanisms and role of bilateral anterior cingulotomy are discussed, along with our surgical techniques and the course of our patients.

  • PDF

Noise in hospital rooms and sleep disturbance in hospitalized medical patients

  • Park, Marn Joon;Yoo, Jee Hee;Cho, Byung Wook;Kim, Ki Tae;Jeong, Woo-Chul;Ha, Mina
    • Environmental Analysis Health and Toxicology
    • /
    • v.29
    • /
    • pp.6.1-6.6
    • /
    • 2014
  • Objectives Hospitalized patients are vulnerable to sleep disturbances because of environmental stresses including noise. While most previous studies on hospital noise and sleep have been performed for medical machines in intensive care units, there is a limited data for patients hospitalized in medical wardrooms. The purpose of present study was to measure noise level of medical wardrooms, identify patient-perceived sources of noise, and to examine the association between noise levels and sleep disturbances in hospitalized patients. Methods Noise dosimeters were used to measure noise level in 29 inpatient wardrooms at a university hospital. Sleep pattern and disturbance were assessed in 103 hospitalized patients, using the Pittsburgh Sleep Quality Index (PSQI) and Leeds Sleep Evaluation Questionnaire. Results The mean equivalent continuous noise level for 24 hours was 63.5 decibel A (dBA), which was far higher than 30 dBA recommended by the World Health Organization for hospital wardrooms. Other patients sharing a room were perceived as the most common source of noise by the patients, which was usually preventable. Of the patients in the study, 86% had bad sleep as assessed by the PSQI. The sleep disturbance was significantly correlated with increasing noise levels in a dose response manner. Conclusions Systemic organizational interventions are needed to keep wardrooms private and quiet to reduce sleep disturbance.

A Clinical Evaluation of Konica Hi-Ortho X-ray Film MGH (Konica Hi-Ortho X-ray Film MGH에 대한 임상평가(臨床評價))

  • Kim, Young-Hwan;Lee, Chang-Yup;Shin, Dong-Sik;Kang, Hong-Seok;Park, Jun-Chul;Lee, In-Ja;Shin, Wha-Soo;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.10 no.1
    • /
    • pp.43-47
    • /
    • 1987
  • Authors have tested on the characteristics, image qualities and clinical applications of Konica Hi-ortho X-ray film MGH. The results are as followed; 1. The speeds of KM/MG, MGH were as about 2.7 times, and those of KR/MG, MGH were as about 4.5 times as compared with LT-II/A and the tube voltage influenced upon KM/MG, MGH over 80 kVp, upon KR/MG, MGH over 90kVp. 2. Good image definition by the detection of Burger Phanton KM/MGH, KM/MG, and LT-II/A, and good I.Q. values by the detection of Hawlet Chart LT-II/A, KM/MGH, and KM/MG in that order. Therefore, MGH film could reduce the patient dose steeply, and furthermore, provide high image quality by the high contrast and then, it will be very useful to abdominal angiography and cerebral angiography.

  • PDF