• Title/Summary/Keyword: reduce patient dose

Search Result 287, Processing Time 0.029 seconds

Evaluation of Effective and Organ Dose Using PCXMC Program in DUKE Phantom and Added Filter for Computed Radiography System (CR 환경에서의 흉부촬영 시 Duke Phantom과 부가여과를 이용한 유효선량 및 장기선량 평가)

  • Kang, Byung-Sam;Park, Min-Joo;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • By using a Chest Phantom(DUKE Phantom) focusing on dose reduction of diagnostic radiation field with the most use of artificial radiation, and attempt to reduce radiation dose studies technical radiation. Publisher of the main user of the X-ray Radiological technologists, Examine the effect of reducing the radiation dose to apply additional filtering of the X-ray generator. In order to understand the organ dose and effective dose by using the PC-Based Monte Carlo Program(PCXMC) Program, the patient receives, was carried out this research. In this experiment, by applying a complex filter using a copper and Al(aluminum,13) and filtered single of using only aluminum with the condition set, and measures the number of the disk of copper indicated by DUKE Phantom. The combination of the composite filtration and filtration of a single number of the disk of the copper is the same, with the PCXMC 2.0. Program looking combination of additional filtration fewest absorbed dose was calculated effective dose and organ dose. Although depends on the use mAs, The 80 kVp AP projection conditions, it is possible to reduce the effective amount of about 84 % from about 30 % to a maximum at least. The 120 kVp PA projection conditions, it is possible to reduce the effective amount of about 71 % from about 41 % to a maximum of at least. The organ dose, dose reduction rate was different in each organ, but it showed a decrease of dose rate of 30 % to up 100 % at least. Additional filtration was used on the imaging conditions throughout the study. There was no change in terms of video quality at low doses. It was found that using the DUKE Phantom and PCXMC 2.0 Program were suitable to calculate the effect of reducing the effective dose and organ dose.

Analysis of changes in dose distribution due to respiration during IMRT

  • Shin, Jung-Suk;Shin, Eun-Hyuk;Han, Young-Yih;Ju, Sang-Gyu;Kim, Jin-Sung;Ahn, Sung-Hwan;Kim, Tae-Gyu;Jeong, Bae-Kwon;Park, Hee-Chul;Ahn, Young-Chan;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.29 no.3
    • /
    • pp.206-213
    • /
    • 2011
  • Purpose: Intensity modulated radiation therapy (IMRT) is a high precision therapy technique that can achieve a conformal dose distribution on a given target. However, organ motion induced by respiration can result in significant dosimetric error. Therefore, this study explores the dosimetric error that result from various patterns of respiration. Materials and Methods: Experiments were designed to deliver a treatment plan made for a real patient to an in-house developed motion phantom. The motion pattern; the amplitude and period as well as inhale-exhale period, could be controlled by in-house developed software. Dose distribution was measured using EDR2 film and analysis was performed by RIT113 software. Three respiratory patterns were generated for the purpose of this study; first the 'even inhale-exhale pattern', second the slightly long exhale pattern (0.35 seconds longer than inhale period) named 'general signal pattern', and third a 'long exhale pattern' (0.7 seconds longer than inhale period). One dimensional dose profile comparisons and gamma index analysis on 2 dimensions were performed. Results: In one-dimensional dose profile comparisons, 5% in the target and 30% dose difference at the boundary were observed in the long exhale pattern. The center of high dose region in the profile was shifted 1 mm to inhale (caudal) direction for the 'even inhale-exhale pattern', 2 mm and 5 mm shifts to exhale (cranial) direction were observed for 'slightly long exhale pattern' and 'long exhale pattern', respectively. The areas of gamma index >1 were 11.88 %, 15.11%, and 24.33% for 'even inhale-exhale pattern', 'general pattern', and 'long exhale pattern', respectively. The long exhale pattern showed largest errors. Conclusion: To reduce the dosimetric error due to respiratory motions, controlling patient's breathing to be closer to even inhaleexhale period is helpful with minimizing the motion amplitude.

A Survey on the Radiation Exposure Doses Reduction Plan through Dose Index Analysis in the Pediatric Brain Computed Tomography (소아 두부 컴퓨터단층촬영검사에서 선량지표 분석을 통한 방사선 피폭선량 감소 방안에 대한 연구)

  • Kim, Hyeon-Jin;Lee, Hyo-Yeong;Im, In-Chul;Yu, Yun-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.161-169
    • /
    • 2016
  • In this study, the proposal to seek ways to reduce the amount of radiation is drawn by comparing and analyzing CT Dose Index(CTDI) on the pediatric head CT which was performed at the busan regional hospitals, to the national diagnostic reference levels. As a result, it was appeared to exceed the amount of the dose recommendation in order of hospital, general hospital and senior general hospital in the hospital-specific classification and from 2 to 5 year, from 1 month to 1 year and from 6 to 10 year in the age-specific classification. In addition, the amount of the dose recommendation was exceed in order of helical, axial and volume in the scan-specific classification. As the results of the scan range reset to match the diagnostic reference level, the dose reduction showed 11.68%, 15.79% and 20.66% in senior general hospital, general hospital and hospital respectively. In the results of analysing patient average scan ranges which does not deviate from the guideline of patient dose recommendation, there was age of 1 month to 1 year, 2 to 5 year and 6 to 10 year of $03.2{\pm}11.8mm$, $110.5{\pm}14.5mm$, and $117.8{\pm}17.2mm$ respectively.

Comparison of Propacetamol plus Fentanyl and Fentanyl alone with Patient Controlled Analgesia after Total Knee Arthroplasty (수술 후 자가통증조절장치 사용 환자에서 propacetamol과 fentanyl 복합제 및 fentanyl 단일제제의 효과 비교)

  • Kim, Minhyung;Jeong, Hyokeun;Park, Sohyun;Rhie, Sandy Jeong
    • Korean Journal of Clinical Pharmacy
    • /
    • v.28 no.1
    • /
    • pp.17-23
    • /
    • 2018
  • Objective: Opioid analgesics, for postoperative pain management, are an indispensable group of medication; however, they also have a variety of adverse drug reactions (ADR). Multimodal methods, combining non-opioid analgesics with opioid analgesics, have been investigated to increase the effects of analgesics and reduce ADR with opioid-sparing effects. The purpose of this study was to compare the effects of patient-controlled analgesia (PCA) with fentanyl alone, and PCA with fentanyl and intravenous (i.v.) propacetamol to determine the effects of pain control, cumulative opioid usage, and opioid ADR. Methods: The subjects were patients who underwent total knee arthroplasty at the Seoul Veterans hospital from January 1, 2015 to December 31, 2016. The study period was from postoperative day 0 (POD0) to day 3 (POD3), and the retrospective study was conducted using electronic medical records. Results: Pain severity was significantly low at POD1 (p = 0.017), POD2 (p = 0.003), and POD3 (p = 0.002) in the multimodal group. The fentanyl only group frequently reported both moderate and severe pain at a statistically significant level. This was consistent with the analysis of the pro re nata (PRN) intramuscular analgesia usage at the time of numerical rating scale (NRS) 4 and above. The opioid-sparing effect confirmed that the average opioid dose equivalent to i.v. morphine dose was 9.4 mg more than that used for the multimodal group in the fentanyl only group. The ADRs and length of stay between the two groups were not statistically different. Conclusion: The results of this study suggest that the combination therapy of fentanyl and i.v. propacetamol is superior to fentanyl monotherapy.

Shielding Capability Evaluation of Slit-shaped Structure for Scattered X-ray using Monte Carlo Method (몬테카를로 방법을 이용한 슬릿형태 구조물의 차폐능력 평가)

  • Kim, Sangrok;Heo, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.733-740
    • /
    • 2020
  • As the use of radiation for medical purposes increases, the exposure dose of medical workers is also increasing. To reduce this dose, various studies on changing the shielding material have been conducted. Recently, a new method to reduce the dose at the entrance of the radiation treatment room was proposed by using the photoelectric effect that occurs when the radiation is scattered. Because this method is particularly effective for low-energy photons, in this study, a slit-type structure was proposed as a excellent shielding structure against scattered x-ray in a general photography room, and was evaluated the shielding effect by Monte Carlo simulation. As a result of the calculation, this study found that in the case of a structure in which steel plates with a thickness of 2 mm and a width of 5 cm are stacked at 2 mm intervals, a shielding effect was approximately 99.9% or more, excluding the heights of the floor and the patient where scattering occurs directly.

Effects of Preoperative Epidural Block with Low Dose Bupivacaine and Morphine on Postoperative Pain, Plasma Cortisol and Serum Glucose in Total Abdominal Hysterectomy (복식전자궁적출술에서 술전 저용량 국소마취제와 Morphine을 이용한 경막외차단이 술후통증, 혈장 Cortisol, 혈당에 미치는 영향)

  • Park, Han-Suk;Lee, Sung-Chul;Cha, Moon-Seok
    • The Korean Journal of Pain
    • /
    • v.12 no.1
    • /
    • pp.21-26
    • /
    • 1999
  • Background: Preoperative blocking of surgical nociceptive inputs may prevent sensitization of central nervous system (CNS) and reduce postoperative pain. The stress responses to surgical trauma consist of increase in catabolic hormones and decrease in anabolic hormones. We studied whether preoperative low dose epidural bupivacaine and morphine could affect postoperative pain, changes plasma cortisol, and serum glucose. Methods: Thirty patients undergoing total abdominal hysterectomy were randomly assigned to one of three groups. General anesthesia was induced in all patients and after that, epidural blocks were done except the control group (n=10) patients. Preoperative block group (n=10) received 0.5% bupivacaine 50 mg and morphine 2 mg epidurally as a bolus before operation and followed by 0.1% bupivacaine $5\;mghr^{-1}$ and morphine $0.2\;mghr^{-1}$ for 10 hours. Postoperative block group (n=10) received the same doses of bupivacaine and morphine under the same method postoperatively. Postoperative pain relief was provided with i.v. fentanyl through Patient-Controlled-Analgesia Pump. Postoperative pain by visual analogue scores (VAS), analgesic requirement (first requirement time, total amounts used), side effects, plasma cortisol level and serum glucose level were compared. Results: Until postoperative 6 hrs, VAS of control group was higher than those of the epidural groups. No difference was observed in VAS between the two epidural groups. First analgesics requirement time and total amounts of used analgesics were not different between the two epidural groups, but first analgesic requirement time of preoperative block group was significantly prolonged compared with control group. Plasma cortisol and serum glucose levels were not different among groups. Conclusions: Low dose preoperative epidural bupivacaine and morphine could not reduce postoperative pain, plasma cortisol level and serum glucose level compared with postoperative block group.

  • PDF

Analysis of Exposure Dose According to Chest and Abdomen Combine CT Exam Method (CT 흉·복부 통합검사 시 선량분석)

  • Mo, KyeongHwan;Han, DongKyoon;Lim, HyunSoo;Jeon, WooJin
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.401-408
    • /
    • 2014
  • The purpose of this study is confirmed to usefulness between division exam and combine exam of chest and abdomen according to comparing chest and abdomen radiation dose of division exam and combine exam in CT exam method. This study was conducted on patients who were admitted to the E hospital from July 2013 to March 2014 underwent CT studies for the diagnosis of chest and abdomen disease. In study result, male dose were more higher than female dose according to gender analysis of exposure dose that combine exam effective dose were male $33.10{\pm}2.75mSv$, female $31.66{\pm}3.12mSv$ and chest exam effective dose were male $9.07{\pm}2.62mSv$, female $8.30{\pm}2.18mSv$(p<0.05). And, division exam dose and combine exam dose were similar in gender comparison (p>0.05). And, combine exam effective dose, only chest exam effective dose, only abdomen exam effective dose were more higher than DRL(Diagnostic Reference Level) in comparison of patient exposure dose with DRL (p<0.05). In conclusion, chest-abdomen combine exam dose and division exam dose were similar. The chest-abdomen combine study can be used as follow-up and emergency trauma patients. That study will be reduce exam time and the occurrence risk of side effect of the contrast medium.

Technetium 99m Pertechnetate Brain Scanning ($^{99m}Tc$ Pertechnetate를 사용(使用)한 뇌(腦)스캐닝)

  • Rhee, Sang-Min;Park, Jin-Yung;Lee, Ahn-Ki;Chung, Choo-Il;Hong, Chang-Gi;Rhee, Chong-Heon;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.2 no.1
    • /
    • pp.59-66
    • /
    • 1968
  • Technetium 99m pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and I case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed "hot areas." Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with $^{203}Hg$-Neohydrin or $^{131}I$-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced $^{99m}Tc$ to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  • PDF

Studies of vision monitoring system using a background separation algorithm during radiotherapy (방사선 치료시 배경분리알고리즘을 이용한 비젼모니터링 시스템에 대한 연구)

  • Park, Kiyong;Choi, Jaehyun;Park, Jeawon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.359-366
    • /
    • 2016
  • The normal tissue in radiation therapy, to minimize radiation, it is most important to maximize local tumor control rates in intensive research the exact dose to the tumor sites. Therefore, the initial, therapist accuracy of detecting movement of the patient fatigue therapist has been a problem that is weighted down directly. Also, by using a web camera, a difference value between the image to be updated to the reference image is calculated, if the result exceeds the reference value, using the system for determining the motion has occurred. However, this system, it is not possible to quantitatively analyze the movement of the patient, the background is changed when moving the treatment bed in the co-therapeutic device was not able to sift the patient. In this paper, using a alpah(${\alpha}$) filter index is an attempt to solve these limitations points, quantifies the movement of the patient, by separating a background image of the patient and treatment environment, and movement of the patient during treatment It senses only, it was possible to reduce the problems due to patient movement.

Comparison of the effects of target-controlled infusion-remifentanil/midazolam and manual fentanyl/midazolam administration on patient parameters in dental procedures

  • Lobb, Doug;Ameli, Nazila;Ortiz, Silvia;Lai, Hollis
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.2
    • /
    • pp.117-128
    • /
    • 2022
  • Background: Moderate sedation is an integral part of dental care delivery. Target-controlled infusion (TCI) has the potential to improve patient safety and outcome. We compared the effects of using TCI to administer remifentanil/manual bolus midazolam with manual bolus fentanyl/midazolam administration on patient safety parameters, drug administration times, and patient recovery times. Methods: In this retrospective chart review, records of patients who underwent moderate intravenous sedation over 12 months in a private dental clinic were assessed. Patient indicators (pre-, intra-, and post-procedure noninvasive systolic and diastolic blood pressure, respiration, and heart rate) were compared using independent t-test analysis. Patient recovery time, procedure length, and midazolam dosage required were also compared between the two groups. Results: Eighty-five patient charts were included in the final analysis: 47 received TCI-remifentanil/midazolam sedation, and 38 received manual fentanyl/midazolam sedation. Among the physiological parameters, diastolic blood pressure showed slightly higher changes in the fentanyl group (P = 0.049), respiratory rate changes showed higher changes in the fentanyl group (P = 0.032), and the average EtCO2 was slightly higher in the remifentanil group (P = 0.041). There was no significant difference in the minimum SpO2 levels and average procedure length between the fentanyl and remifentanil TCI pump groups (P > 0.05). However, a significant difference was observed in the time required for discharge from the chair (P = 0.048), indicating that patients who received remifentanil required less time for discharge from the chair than those who received fentanyl. The dosage of midazolam used in the fentanyl group was 0.487 mg more than that in the remifentanil group; however, the difference was not significant (P > 0.05). Conclusion: The combination of TCI administered remifentanil combined with manual administered midazolam has the potential to shorten the recovery time and reduce respiration rate changes when compared to manual administration of fentanyl/midazolam. This is possibly due to either the lower midazolam dosage required with TCI remifentanil administration or achieving a stable, steady-state low dose remifentanil concentration for the duration of the procedure.