• Title/Summary/Keyword: red light camera

Search Result 51, Processing Time 0.034 seconds

Using DSLR Camera for Digital Film Making (영화제작에서 DSLR 카메라의 활용성에 관한 연구)

  • Son, Bo-Wook;Min, Kyung-Won
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.5
    • /
    • pp.81-90
    • /
    • 2012
  • Since the Canon EOS 5D Mark II with which the Full HD video shooting is possible was launched in 2008, the utilization of the DSLR cameras has been increasing in the video production field. In this thesis, the shortages and advantages of the video functions that the 5D Mark II cameras have will be analysed and they will be compared with the RED cameras that are most widely used in the video production field today. Through this, the utilization of the DSLR camera in the film production field will be investigated. The DSLR camera has the advantage of having good clear picture since it uses the image sensor of big size, and of being able to utilize the various lenses of good quality, and is small in size and light in weight compared to the conventional HD cameras. Although, there are some limitations that there are parts to be improved such as the sound recording problems and development of various additional equipments, the excellent usage that the DLSR cameras have is presenting a new possibility for the film production.

RGB-LED-based Optical Camera Communication using Multilevel Variable Pulse Position Modulation for Healthcare Applications

  • Rachim, Vega Pradana;An, Jinyoung;Pham, Quan Ngoc;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.6-12
    • /
    • 2018
  • In this paper, a 32-variable pulse position modulation (32-VPPM) scheme is proposed to support a red-green-blue light-emitting-diode (RGB-LED)-based optical camera communication (OCC) system. Our proposed modulation scheme is designed to enhance the OCC data transmission rate, which is targeted for the wearable biomedical data monitoring system. The OCC technology has been utilized as an alternative solution to the radio frequency (RF) wireless system for long-term self-healthcare monitoring. Different biomedical signals, such as electrocardiograms, photoplethysmograms, and respiration signals are being monitored and transmitted wirelessly from the wearable biomedical device to the smartphone receiver. A common 30 frames per second (fps) smartphone camera with a CMOS image sensor is used to record a transmitted optical signal. Moreover, the overall proposed system architecture, modulation scheme, and data demodulation are discussed in this paper. The experimental result shows that the proposed system is able to achieve > 9 kbps using only a common smartphone camera receiver.

Red fluorescence of oral bacteria interacting with Porphyromonas gingivalis (Porphyromonas gingivalis가 일부 구강미생물의 형광 발현에 미치는 영향)

  • Kim, Se-Yeon;Woo, Dong-Hyeob;Lee, Min-Ah;Kim, Ji-Soo;Lee, Jung-Ha;Jeong, Seung-Hwa
    • Journal of Korean Academy of Oral Health
    • /
    • v.41 no.1
    • /
    • pp.22-27
    • /
    • 2017
  • Objectives: Dental plaque is composed of 700 bacterial species. It is known that some oral microorganisms produce porphyrin, and thus, they emit red fluorescence when illuminated with blue light at a specific wavelength of <410 nm. Porphyromonas gingivalis belongs to the genus Porphyromonas, which is characterized by the production of porphyrin. The aim of this study was to evaluate red fluorescence emission of some oral microorganisms interacting with P. gingivalis. Methods: Five bacterial strains (P. gingivalis, Streptococcus mutans, Lactobacillus casei, Actinomyces naeslundii, and Fusobacterium nucleatum) were used for this study. Tryptic soy agar medium supplemented with hemin, vitamin K3, and sheep blood was used as a growth medium. The fluorescence emission of bacterial colonies was evaluated under 405 nm-wavelength blue light using a Quantitative Light-induced Fluorescence Digital (QLF-D) camera system. Each bacterium was cultured alone and co-cultured in close proximity with P. gingivalis. The red/green (R/G) ratio of fluorescence image was calculated and the differences of R/G ratio according to each growth condition were compared using the Mann-Whitney test (P<0.05). Results: Single cultured S. mutans, L. casei and A. naeslundii colonies emitted red fluorescence (R/G ratio=$2.15{\pm}0.06$, $4.31{\pm}0.17$, $5.52{\pm}1.29$, respectively). Fusobacterium nucleatum colonies emitted green fluorescence (R/G ratio=$1.36{\pm}0.06$). The R/G ratios of A. naeslundii and F. nucleatum were increased when P. gingivalis was co-cultured with each bacterium (P<0.05). In contrast, the R/G ratios of S. mutans and L. casei were decreased when P. gingivalis was co-cultured with each bacterium (P=0.002, 0.003). Conclusions: This study confirmed that P. gingivalis could affect the red fluorescence of other oral bacteria under 405 nm-wavelength blue light. Our findings concluded that P. gingivalis has an important role for red fluorescence emission of dental biofilm.

Real-time People Occupancy Detection by Camera Vision Sensor (카메라 비전 센서를 활용하는 실시간 사람 점유 검출)

  • Gil, Jong In;Kim, Manbae
    • Journal of Broadcast Engineering
    • /
    • v.22 no.6
    • /
    • pp.774-784
    • /
    • 2017
  • Occupancy sensors installed in buildings and households turn off the light if the space is vacant. Currently PIR (pyroelectric infra-red) motion sensors have been utilized. Recently, the researches using camera sensors have been carried out in order to overcome the demerit of PIR that can not detect static people. If the tradeoff of cost and performance is satisfied, the camera sensors are expected to replace the current PIRs. In this paper, we propose vision sensor-based occupancy detection being composed of tracking, recognition and detection. Our softeware is designed to meet the real-time processing. In experiments, 14.5fps is achieved at 15fps USB input. Also, the detection accuracy reached 82.0%.

THE DIFFUSE NEAR-INFRARED BACKGROUND SPECTRUM FROM AKARI

  • Kohji, Tsumura;Toshio, Matsumoto;Shuji, Matsuura;Itsuki, Sakon;Takehiko, Wada
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.321-326
    • /
    • 2017
  • We analyzed spectral data of the astrophysical diffuse emission obtained with the low-resolution spectroscopy mode on the AKARI InfraRed Camera (IRC) in the $1.8-5.3{\mu}m$ wavelength region. Advanced reduction methods specialized for slit spectroscopy of diffuse sky spectra have been developed, and a catalog of 278 spectra of the diffuse sky covering a wide range of Galactic and ecliptic latitudes was constructed. Using this catalog, two other major foreground components, the zodiacal light (ZL) and the diffuse Galactic light (DGL), were separated and subtracted by taking correlations with ZL brightness estimated by the DIRBE ZL model and with the $100{\mu}m$ dust thermal emission, respectively. The isotropic emission was interpreted as the extragalactic background light (EBL), which shows significant excess over the integrated light of galaxies at <$4{\mu}m$.

A Study on E-sensitized Systems for Pedestrian Crosswalk Safety (횡단보도 보행자 안전을 위한 전자감응시스템)

  • Lee, Jong-Won;Park, Sung-Won;Moon, Geon-Hee;Jung, Hoe-kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.564-566
    • /
    • 2015
  • Red traffic light indicates a different meaning, the green one. Motorists and pedestrians in the crosswalk must stop or move in accordance with a signal light. However, the probability of an accident is high if you do not see or ignore these signals. In addition to the curved pedestrian crossing installed the announcement system using an infrared sensor is difficult. In this paper, we design and implement methods of detecting pedestrians using the camera. A camera installed on the pontoon walking up the pedestrian and the pedestrian detection range is set through the image. With the proposed system it is effective in detecting pedestrians in the crosswalk curved.

  • PDF

Prevention of Collision with Other Vessels Using Camera Sensors with Kalman Filter (칼만 필터가 적용된 카메라 센서를 이용한 타 선박과의 충돌 예방)

  • Dae-il Sung;Sung-Joo Kim;Young-Min Kim;Yun-Sung Jung;Min-Seok Han
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.3
    • /
    • pp.130-140
    • /
    • 2024
  • In this paper, we present a method of applying the kalman filter to control and correct errors in camera sensor recognition depending on the sea state environment. First, the specifications of the ship were described and the degree of error due to rolling was measured. After presenting the distance from the surface of the water to the sidelight required for simulation through PKMR-211, the ship selected as the model, error correction was performed using the camera error value as a variable in the feedback control system. In the experiment, the degree of rolling of the ship was expressed as variables 𝛼 and 𝛽, expressed in angles, and the angle change according to distance was compared. When comparing the error before and after applying the kalman filter in sea state 4, it decreased from +1.5556° to -1.1544° in red light regardless of distance, and the same result was confirmed in green light. Through this, calculations were performed considering the movement of the ship according to the maritime environment, and the future maneuverability of the ship was presented after error correction.

Analysis of Blood Cell Images Using Smartphone-based Mobile SmartScope (스마트폰 기반 Mobile SmartScope를 이용한 혈구 영상 분석)

  • Park, Choonho;Cho, Myoung-Ock;Lee, Donghee;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.2
    • /
    • pp.25-31
    • /
    • 2012
  • High-performance smartphones, equipped with a digital camera and an application software, can render conventional bench-top laboratory instruments mobile at affordable costs. As the smartphone-based devices are portable and wireless, they have wide applications especially in providing point-of-care (POC) tests in resource-constrained areas. We developed a hand-held diagnostic system, Mobile SmartScope, which consists of a small optical unit integrated with a smartphone. The performance of the SmartScope was favorably compared with that of conventional light microscopy in detecting and quantifying red blood cells. We also evaluated the fluorescence detection limit of the SmartScope incorporated with a blue light-emitting diode and appropriate optical filters by using fluorescently labeled microbeads for intensity calibration.

Safety Impacts of Red Light Enforcement on Signalized Intersections (교차로 신호위반 단속카메라 설치가 차량사고에 미치는 영향)

  • Lee, Sang Hyuk;Lee, Yong Doo;Do, Myung Sik
    • Journal of Korean Society of Transportation
    • /
    • v.30 no.6
    • /
    • pp.93-102
    • /
    • 2012
  • The frequency and severity of traffic accidents related to signalized intersections in urban areas have been more serious than those in both arterial segments and crosswalks. Especially, traffic accidents involved with injuries and fatalities have caused by traffic signal violations within intersections. Therefore, many countries including Korea have installed the red light enforcement camera (RLE) to reduce traffic accidents associated with the traffic signal violation. Meanwhile, many methodologies have been studied in terms of safety impacts estimation of red light enforcement, which, however, cannot be easy to conduct. In this study, safety impacts was estimated for intersections of Chicago downtown area using SPF models and EB approach. As a result, for all crash types and target traffic accident types such as "angle", "rear end", "sideswipe in the same and other directions", "turn", and "head on", fatal crashes were reduced by 26% and 38%. However, RLE may increase property-demage-only-crashes by 3.23% and 1.16%, respectively.

Natural Color Recognition algorithm Based on Fuzzy Similarity Measure (퍼지 유사도 평가를 이용한 천연색상 인식 알고리듬)

  • Kim, Youn-Tae;Kim, Sung-Shin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.1123-1127
    • /
    • 2005
  • The Conventional methods of color separation in computer-based machine vision offer only weak performance because of environmental factors such as light source, camera sensitivity, and others. In this paper, we propose an improved color separation method using RGB, HLS, color coordination space, and fuzzy similarity measure. RGB consists of red, green and blue, the three primary colors of light. HLS includes hue, light and saturation, the human recognition elements of co]or. A fuzzy similarity measure was employed for evaluate the similarity among fuzzy colors with the six features of RGB and HLS.

  • PDF