• 제목/요약/키워드: recovery under load

검색결과 73건 처리시간 0.025초

피로균열진전에 따른 304 강의 음향방출 거동 (Acoustic emission behavior during fatigue crack propagation in 304 Stainless steel)

  • 오광환;정창규;양유창;한경섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.213-219
    • /
    • 2003
  • Acoustic emission behavior during fatigue crack growth test was investigated under various loading condition. To describe the acoustic emission activity, counts rate (d/dn) was related with SIFR (stress intensity factor range, K). Results indicated that SIFR could be divided into two parts according to its relationship with counts rate. For $K<25_{MPa\sqrt{m}}$, counts rate was increased as the SIFR increased. However, for values greater than $25_{MPa\sqrt{m}}$ , decreasing behavior was shown. This behavior of counts rate corresponding SIFR was keeping the same trend regardless of load range or crack length. Acoustic emission response to the single overload was sudden drop and slow recovery in counts rate like crack growth retardation. Under variable loading condition, counts rate of each loading block was same as that of constant amplitude loading. Overall experimental data was somewhat scattered since sensitive characteristics of acoustic emission method. However, these empirical relations indicated that counts rate was uniquely correlate with single parameter, SIFR.

  • PDF

냉방주체 운전모드에서 동시냉난방 열펌프 성능향상에 관한 실험적 연구 (Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Cooling-main Operating Mode)

  • 정현준;주영주;강훈;김용찬;최종민
    • 설비공학논문집
    • /
    • 제20권5호
    • /
    • pp.314-320
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the improved wall insulation. Hence, a multi~heat pump is required to cover heating and cooling simultaneously for each indoor unit. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the cooling-main operating mode were investigated experimentally. The system adopted a variable speed compressor using R410A with four indoor units and one outdoor unit. In the cooling-main mode, the heating capacity decreased due to reduction of flow rate to the indoor unit under heating mode operation. The EEV opening was adjusted to increase flow rate to the indoor unit under heating mode operation. The total capacity and COP in the cooling-main mode increased by 20.5% and 29.2%, respectively, compared with those in the cooling-only mode.

터보과급 디젤기관의 과도운전시 응답성능에 관한 연구 (A Study on the Response Performances under Transient Operating Conditions in a Turlblocharged Diesel Engine)

  • 최낙정;이창식
    • 대한기계학회논문집
    • /
    • 제16권8호
    • /
    • pp.1575-1582
    • /
    • 1992
  • 본 연구에서는 정상운전 중인 4사이클 6실린더 터보과급 디젤기관에 갑자기 큰 부하가 작용하였을 경우, 기관 및 과급기 관성 모멘트의 변화가 기관과 과급기의 실제 회전속도, 압축기 압력비, 실린더내 공기유량, 연소효율, 배기온도 등의 과도 응 답성능에 미치는 영향을 시뮬레이션해석과 실험을 통하여 규명하였다.

외기조건변화에 따른 CHP 성능 해석 (Performance Analysis of CHP(Combined Heat and Power) for Various Ambient Conditions)

  • 전용한;김종윤;김남진;임경범;서영호;김기환
    • 한국산학기술학회논문지
    • /
    • 제12권8호
    • /
    • pp.3353-3359
    • /
    • 2011
  • 본 연구에서는 가스터빈과 증기터빈, 열회수증기 발생 장치와 지역난방 열교환기로 열병합 발전 시스템을 구성하여 복수기가 없이 증기 터빈 중압단에서 추기된 증기와 배기 증기를 지역난방 열교환기의 열원으로 사용하는 추기 배압식을 적용하였다. 구성된 시스템에 대하여 필요로 하는 열부하량과 발전 출력 조건을 만족 시키기 위한 최적 설계 성능 해석을 하였으며, 이와 함께 겨울철 외기 온도 조건의 변화에 대한 시스템의 부분부하 해석을 하였다. 해석을 위해 상용 프로그램인 Thermoflex를 사용하였다. 시스템의 해석 결과, 기준 조건에서 수요처의 요구를 만족 시키는 최적 설계를 기준으로 각 외기 온도 변화에 대한 부분부하 성능 해석의 결과를 얻을 수 있었다. 그 결과 열부하량이 고정된 상태에서, 가스터빈과 전체 시스템의 출력은 외기온도가 감소함에 따라서 증가하였지만, 열원인 배기가스의 온도 감소로 인하여 증기터빈의 출력은 이와 반대로 감소하는 경향을 나타내었다. 그러나 전체 시스템에서 가스터빈의 차지하는 비중이 크기 때문에 전체 시스템의 출력의 경향은 가스터빈과 동일한 결과를 얻을 수 있었다.

Damage characterization of hard-brittle rocks under cyclic loading based on energy dissipation and acoustic emission characteristics

  • Li, Cheng J.;Lou, Pei J.;Xu, Ying
    • Geomechanics and Engineering
    • /
    • 제31권4호
    • /
    • pp.365-373
    • /
    • 2022
  • In order to investigate the damage evolution law of rock specimens under cyclic loading, cyclic loading tests under constant loads with different amplitudes were carried out on limestone specimens with high strength and brittleness values using acoustic emission (AE) technology and the energy evolution and AE characteristics were evaluated. Based on dissipated energy density and AE counts, the damage variable of specimen was characterized and two damage evolution processes were analyzed and compared. The obtained results showed that the change of AE counts was closely related to radial deformation. Higher cyclic loading values result in more significant radial strain of limestone specimen and larger accumulative AE counts of cyclic loading segment, which indicated Felicity effect. Regarding dissipated energy density, the damage of limestone specimen was defined without considering the influence of radial deformation, which made the damage value of cyclic loading segment higher at lower amplitude loads. The damage of cyclic loading segment was increased with the magnitude of load. When dissipated energy density was applied to define damage, the damage value at unloading segment was smaller than that of AE counts. Under higher cyclic loading values, rocks show obvious damage during both loading and unloading processes. Therefore, during deep rock excavation, the damages caused by the deformation recovery of unloading rocks could not be ignored when considering the damage caused by abutment pressure.

Systematic Analysis for the Effects of Atmospheric Pollutants in Cathode Feed on the Performance of Proton Exchange Membrane Fuel Cells

  • Yoon, Young-Gon;Choi, Insoo;Lee, Chang-Ha;Han, Jonghee;Kim, Hyoung-Juhn;Cho, EunAe;Yoo, Sung Jong;Nam, Suk Woo;Lim, Tae-Hoon;Yoon, Jong Jin;Park, Sehkyu;Jang, Jong Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권12호
    • /
    • pp.3475-3481
    • /
    • 2014
  • This paper describes how primary contaminants in ambient air affect the performance of the cathode in fuel cell electric vehicle applications. The effect of four atmospheric pollutants ($SO_2$, $NH_3$, $NO_2$, and CO) on cathode performance was investigated by air impurity injection and recovery test under load. Electrochemical analysis via polarization and electrochemical impedance spectroscopy was performed for various concentrations of contaminants during the impurity test in order to determine the origins of performance decay. The variation in cell voltage derived empirically in this study and data reported in the literature were normalized and juxtaposed to elucidate the relationship between impurity concentration and performance. Mechanisms of cathode degradation by air impurities were discussed in light of the findings.

Rehabilitation of a distressed steel roof truss - A study

  • Dar, M.A.;Subramanian, N.;Dar, A.R.;Raju, J.
    • Structural Engineering and Mechanics
    • /
    • 제62권5호
    • /
    • pp.567-576
    • /
    • 2017
  • Structural failures are undesirable events that devastate the construction industry resulting in loss of life, injury, huge property loss, and also affect the economy of the region. Roof truss failures occur mainly due to excessive loading, improper fabrication, deterioration, inadequate repair, etc. Although very rare, a roof truss may even fail due to inappropriate location of supports. One such case was reported from the recent failure of a steel roof truss used in an indoor stadium at Kargil in India. Kargil region, being mountainous in nature, receives heavy snowfall and hence the steel roof trusses are designed for heavy snow loads. Due to inappropriate support location, the indoor stadium's steel roof truss had failed under heavy snow load for which it was designed and became an interesting structural engineering problem. The failure observed was primarily in terms of yielding of the bottom chord under the supports, leading to partial collapse of the roof truss. This paper summarizes the results of laboratory tests and analytical studies that focused on the validation of the proposed remedial measure for rehabilitating this distressed steel roof truss. The study presents the evaluation of (i) significant reduction in strength and stiffness of the distressed truss resulting in its failure, (ii) desired recovery in both strength and stiffness of the rectified truss contributed by the proposed remedial measure. Three types of models i.e., ideal truss model, as build truss model and rectified truss model were fabricated and tested under monotonic loading. The structural configuration and support condition varied in all the three models to represent the ideal truss, distressed truss and the rectified truss. To verify the accuracy of the experimental results, an analytical study was carried out and the results of this analytical study are compared with the experimental ones.

FRP 하이브리드 보강근을 가지는 RC보의 반복하중에 대한 역학적 성능 평가 (Mechanical Performance Evaluation of RC Beams with FRP Hybrid Bars under Cyclic Loads)

  • 황철성;박재성;박기태;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권1호
    • /
    • pp.9-14
    • /
    • 2017
  • 본 연구는 일반철근과 FRPH Bar를 주철근으로 한 철근 콘크리트 보부재를 대상으로 정적실험 및 반복하중 재하실험을 수행하여 에너지 소산성능 및 반복하중 저항성능을 분석하였다. 실험을 위하여 24MPa의 설계강도를 가진 콘크리트 보부재($200{\times}200{\times}2175mm$)를 제작하였으며, 4점 휨 시험을 수행하여 초기균열하중, 항복하중, 파괴하중을 측정하였다. 정적하중 재하실험을 통해 각 시험체에 대한 항복하중과 파괴강도를 측정하였는데, 항복하중은 RC보에서는 48.9kN, FRPH 보에서는 36kN으로 평가되었으며, 파괴하중은 두 시험체 모두 50kN의 강도를 보였다. 정적하중-처짐 결과에서는 FRPH 보는 RC보에 비하여 인장경화특성을 나타내는데, 이는 FRPH bar의 인장경화 특성에 기인한다. 반복하중하에서 FRPH bar를 가진 보에서는 일반 RC보와는 다르게 작은 폭의 균열이 넓게 발생하였으며, 우수한 처짐 복원력을 나타내었다. 정적 동적 에너지 비율을 이용한 에너지 소산능력에서는 RC보에서는 0.62, FRPH 보에서는 0.83으로 평가되었으며, 이를 통해 FRPH를 가진 보부재에서 효과적으로 반복하중에 대하여 저항함을 알 수 있다.

Highly Efficient AC-DC Converter for Small Wind Power Generators

  • Ryu, Hyung-Min
    • Journal of Power Electronics
    • /
    • 제11권2호
    • /
    • pp.188-193
    • /
    • 2011
  • A highly efficient AC-DC converter for small wind power generation systems using a brushless DC generator (BLDCG) is presented in this paper. The market standard AC-DC converter for a BLDCG consists of a three-phase diode rectifier and a boost DC-DC converter, which has an IGBT and a fast recovery diode (FRD). This kind of two-stage solution basically suffers from a large amount of conduction loss and the efficiency greatly decreases under a light load, or at a low current, because of the switching devices with a P-N junction. In order to overcome this low efficiency, especially at a low current, a three-phase bridgcless converter consisting of three upper side FRDs and three lower side Super Junction FETs is presented. In the overall operating speed region, including the cut-in speed, the efficiency of the proposed converter is improved by up to 99%. Such a remarkable result is validated and compared with conventional solutions by calculating the power loss based on I-V curves and the switching loss data of the adopted commercial switches and the current waveforms obtained through PSIM simulations.

Experimental Evaluation of Position Sensorless Control on Hybrid Electric Vehicle Applications

  • Choi, Chan-Hee;Kim, Bum-Sik;Lee, Young-Kook;Jung, Jin-Hwan;Seok, Jul-Ki
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.464-470
    • /
    • 2011
  • In this paper, the feasibility of applying a position sensorless control technique to hybrid electric vehicles (HEVs) is practically evaluated. The proposed position estimator has a straightforward structure with properties that combines the model and the saliency tracking-based rotor position estimation for interior permanent magnet synchronous motors (IPMSMs). The proposed method can be used in the event of sensor loss or sensor recovery to sustain continuity of operations. The developed system takes into account the estimated position transition between two distinct sensorless methods. The transition is enhanced by introducing a synchronized transition algorithm based on a single tracking observer. Extensive experimental results are presented to verify the principles and show a reliable estimation performance over the entire speed range including standstill under 150% load conditions.