• Title/Summary/Keyword: recovery cost

Search Result 608, Processing Time 0.032 seconds

Development of Service Monitoring and Fault-management System in WBI Environment (WBI 환경에서의 서비스 모니터링 및 장애관리 시스템 구현)

  • Choi, Yong S.
    • The Journal of Korean Association of Computer Education
    • /
    • v.8 no.5
    • /
    • pp.119-128
    • /
    • 2005
  • As the number and diversity of educational services increases rapidly on the Internet, we are faced with some service availability problems including persistent service monitoring and fault tolerancy. In this paper, we implemented a service monitoring & fault management system to enhance this availability and reduce administration cost of WBI system. In order to validate our system, we also illustrated an effective real-time monitoring and automatic fault announcement & recovery from our experiences in a real world WBI environment.

  • PDF

A Cost-effective 60Hz FHD LCD Using 800Mbps AiPi Technology

  • Nam, Hyoung-Sik;Oh, Kwan-Young;Kim, Seon-Ki;Kim, Nam-Deog;Kim, Sang-Soo
    • Journal of Information Display
    • /
    • v.10 no.1
    • /
    • pp.37-44
    • /
    • 2009
  • AiPi technology incorporates an embedded clock and control scheme with a point-to-point bus topology, thereby having the smallest possible number of interface lines between a timing controller and column drivers. A point-to-point architecture boosts the data rate and reduces the number of interface lines, because impedance matching can be easily achieved. An embedded clock and control scheme is implemented by means of multi-level signalling, which results in a simple clock/data recovery circuitry. A 46" AiPi-based 10-bit FHD prototype requires only 20 interface lines, compared to 38 lines for mini-LVDS. The measured maximum data rate per data pair is more than 800 Mbps.

Vibration Contol of Automotive Suspension System using the LQG/LTR Control Methodology (LQG/LTR제어기법을 이용한 자동차 서스펜션 시스템의 진동제어)

  • Ahn, Jeong-Keun;Song, Chang-Hun;Yoo, Sam-Hyeon;Lee, Chong-Won
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.646-653
    • /
    • 2001
  • LQG/LTR Control Methology is recently used for the analysis of multi-variable control in frequency domain. Target filter loop is designed by the demanding requirements such as cross-over frequency, disturbance rejection in low frequency domain, zero steady-state error, identification of maximum and minimum singular values and sensor noise rejection in high frequency domain. Loop transfer recovery is accomplished by solving the cheap control and then simulation close to the target filter loop. In this study, LQG/LTR Control Methodology is applied to the seat suspension system. It is found that this technique is very effective to control the system and improve the ride quality of human body.

  • PDF

A Study on Flow Rate Properties and Optimal Selection of Nitrogen Membrane Module of Hollow Fiber Type (중공사형 질소 분리막 모듈의 최적 선정과 유량특성에 관한 연구)

  • Kim, Jong-Do;Lee, Sangu-Su;Kim, Jeon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.915-922
    • /
    • 2008
  • The gas separation technology using membrane is widely used to refine various gases in many industry fields and recently is being applying in $CO_2$ recovery technology. In the gas and chemical tanker. nitrogen generators for inerting, purging and padding are on board and most of them have membrane modules of hollow fiber type with long life and vibration resisting properties. Because a membrane module is a key component accounting for 50% of total manufacturing cost of nitrogen generator, adequate selection for it is an important problem. In this paper, the flow performance coefficient based on dimension and specification data of membrane module was relatively selected to compare nitrogen generating capacity of module and various performance tests about the selected PARKER ST6010 membrane module were conducted. As a result, the useful coefficient and basic data in selecting a membrane module were achieved.

Wireless Sensor Networks in Smart Grid on Demand Management

  • Lee, Sang-Hyun;Jeon, An-Gyoon;Moon, Kyung-Il
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.6 no.2
    • /
    • pp.17-19
    • /
    • 2014
  • Now is the applications are using WSN for environmental monitoring and surveillance applications, intelligent transportation systems, monitoring, disaster recovery, and the structure used in the field. Also, the low cost of the communication and control functions can be provided, in particular management of smart grid demand may be used in many applications. In this paper, WSN in smart grid is based on the building blocks of smart grid management system proposed for the fuzzy demand.

Secondary Non-ferrous Metals Industry in China: Present Situation and Development Tread

  • Qiu, Dingfan;Wang, Chengyan;Jiang, Peihai
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.29-33
    • /
    • 2001
  • The production of Secondary Non-ferrous Metals (SNM) is characterized by low investment, energy consumption and cost, less pollution as well as rather simple technology. In the past years, the SNM industry has seen relevantly rapid progress in China. Especially in the filed of clean hydrometallurgical treatment certain novel technologies for recovery and separation have successfully been elaborated, and a number of medium and small commercial plants established. On the basis of four common metals Cu, Al, Pb, Zn, and Ni, Co, this paper describes the status quo and progress of SNM industry in China, indicating that a lot of work should still be done in salvage of waste metals. It is recommended that measures for collecting and classifying SNM resource should be strengthened and the research on new technologies for scavenging such metals should be supported.

  • PDF

Design Parameter of CW Klystron System for KOMAC

  • Lee, J. H.;H. J. Kwon;Kim, T. Y.;K. H. Chung;H. S. Kang;Park, S. J.;J. S. Oh;Kim, Dong-Il
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.963-966
    • /
    • 1998
  • The KOMAC(KOrea Multi-purpose Accelerator Complex) linac is composed of RFQ(Radio Frequency Quadrupole), CCDTL(Coupled Cavity Drift Tube Linac) and SC(Superconducting)-linac. The required CW output power of RF system is about 25㎿ for 20㎿ proton beam power. Therefore high power RF sources are necessary for cost saving and reliability improvement. The number of klystrons for 0.5 ㎿ at 350MHz and 1 ㎿ at 700MHz are 1 and 31, respectively. In this paper, the design parameters of the klystron system including power supply and energy recovery system are presented.

  • PDF

Efficient Polynomial Base FIR Interpolation Circuit Using Support Filter (보조 필터를 이용한 효율적인 FIR 보간 회로)

  • Kim, Yong-Eun;Chung, Jin-Gyun
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.4
    • /
    • pp.78-83
    • /
    • 2008
  • Interpolation filters are widely used in symbol timing recovery systems to interpolate new sample values at arbitrary points between the existing discrete-time samples. Polynomial interpolation is interpolated by coefficient made inputted information. This paper presents an efficient way to implement polynomial base interpolation filters using support filter changing input. By an example, it is shown that the proposed structure out performs the conventional interpolation structure with less hardware cost.

Analysis on the Limiting Method after Half Cycle of Hybrid Superconducting Fault Current Limiter using Simulation (시뮬레이션을 이용한 하이브리드 초전도 전류제한기의 반주기 후 한류 방식 분석)

  • Ahn, Jae-Min;Kim, Jin-Seok;Moon, Jong-Fil;Lim, Sung-Hun;Kim, Jae-Chul;Hyun, Ok-Bae;Seol, Kyu-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.63-64
    • /
    • 2008
  • The increase of fault current due to large demand has caused the capacity of power machines in power grid to increase. To protect the power system effectively from the large fault current, several superconducting fault current limiters have been proposed. however, in order to apply superconducting fault current limiters into power system, there are many problems such as cost, recovery, AC loss, and cryogenic. In order to solve these problems, hybrid superconducting fault current limiter(HSFCL) was proposed. However, HSFCL also has a problem that is protective coordination in distribution system with HFSCL. In this paper, HSFCL limiting after half cycle modeled and analyzed about protective coordination.

  • PDF

Modeling of Hybrid Superconducting Fault Current Limiter(HSFCL) using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 하이브리드 초전도 전류제한기 모델링)

  • Ahn, Jae-Min;Kim, Jin-Seok;Moon, Jong-Fil;Lim, Sung-Hun;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.46-48
    • /
    • 2008
  • The increase of fault current due to large demand has caused the capacity of power machines in power grid to increase. To protect the power system effectively from the large fault current, several superconducting fault current limiters have been proposed. however, in order to apply superconducting fault current limiters into power system, there are many problems such as cost, recovery, AC loss, and cryogenic. In order to solve these problems, hybrid superconducting fault current limiter(HSFCL) was proposed. In this paper, we modeled hybrid superconducting fault current limiter using PSCAD/EMTDC and analyed fault current limiting characteristic and total resistance of hybrid superconducting fault current limiter.

  • PDF