• 제목/요약/키워드: recovery cost

검색결과 608건 처리시간 0.033초

복합화력 발전플랜트의 근사 최적 열설계 해석 (Approximate Optimum Thermal Design Analysis of Combined Cycle Power Plant)

  • 전용준;신흥태;이봉렬;김동섭;노승탁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.782-787
    • /
    • 2001
  • An optimum thermal design analysis of the combined cycle power plant with triple pressure heat recovery steam generator was performed by the numerical simulation. The optimum design module used in the paper is DNCONF, a function of IMSL Library, which is widly known as a method to search for the local optimum. The objective function to be minimized is the cost of total power plant including the steam turbine power enhancement premium. The result of this paper shows that the cost reduces if the design point of power plant becomes the local optimum, and many calculations at various initial conditions should be carried out to get the value near the global optimum.

  • PDF

잔존수명을 활용한 제조설비의 경제적 감가상각률 추정방안 (A Study on the Estimation of Economic Depreciation Rate on Industrial Property U sing Remianing Life)

  • 오현승;조진형
    • 산업경영시스템학회지
    • /
    • 제33권3호
    • /
    • pp.219-224
    • /
    • 2010
  • Depreciation accounting has as its main objective, the recovery of the original cost of plant investment less net salvage, over the estimated useful life of that plant. Accuracy of the whole life technique in meeting this objective depends entirely on the original estimates of service life and net salvages for an account. Where the whole life technique has been used and original estimates prove inaccurate, excessive or deficient accumulations in the depreciation reserve frequently occur. To overcome this, the remaining life technique is suggested to better match the challenges of accelerated technology and competition within the regulated environment. The flexibility of the remaining life technique will allow an even chance to provide a complete recovery of the original cost.

에너지 회수를 위한 열교환망 합성에 관한 연구 (A Study on Synthesis of Heat Exchanger Network for Heat Recovery)

  • 이해평;황경균;류경옥
    • 에너지공학
    • /
    • 제2권2호
    • /
    • pp.215-224
    • /
    • 1993
  • 열교환망 합성은 에너지 회수와 절감 측면에서 상당히 중요한 문제이다. 최적 열교환망 합성 구조를 얻기 위해 multiple utility를 사용하여 유틸리티 소비를 최소화하는 방법을 제안하였으며, 공정 stream들간의 실제적인 합성은 수행하지 않고 목표값 설정에 중점을 두었다. 본 연구에서 제안한 이론을 근거로 하여 개발된 프로그램을 기존의 주정생산공정의 증류공정에 적용하여 좋은 결과를 얻을 수 있었다.

  • PDF

CBP 시장에서 중간/첨두부하용 발전설비의 수익분석과 개선방안 (A study on the revenue improvement of Intermediate/Peak Load Generating Unit in CBP Electricity Market)

  • 김창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.422-425
    • /
    • 2003
  • CBP market which is the first stage of competitive electricity market has been operated and the KPX has been established since April, 2001 by restructuring plan for electricity industry. Baseload unit are settled with baseload CP and BLMP in CBP market. The other unit are settled with peakload CP and SMP. The difference of settlement between two groups occurs the profit changes of the unit. This paper analyzes the profit by units under settlement rule in CBP market. It analyzes the difference between market clearing price and variable costs, and fixed cost recovery through CP income. Finally, this paper suggests the plan how market was affected by the difference of fixed cost recovery by generators and how to improve Intermediate and peak load unit's profit.

  • PDF

Experimental und Numerical Sensitivity Analyses on Push Pull Tracer Tests

  • Hwang, Hyeon-Tae;Lee, Gang-Geun
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.312-316
    • /
    • 2004
  • Single-well tracer tests, especially push pull tracer tests, are more effective to estimate hydraulic parameters and microbial metabolic activities in terms of duration and cost compared to multi-well tracer tests. However, there are some drawbacks in accuracy, complicated data analysis and uniqueness. These shortages are thought to be derived from the applied conditions which affect mass recovery curve and breakthrough curve. Factors such as extraction rate, resting period, hydraulic conductivity and hydraulic gradient are considered as the major factors determining the mass recovery rate and shape of the breakthrough curve. The results of the sensitivity analysis are summarized as follows: 1) the significant change in concentration of breakthrough curve is obtained when the extraction rate increases. This effect would also be much higher if the hydraulic conductivity is lower; 2) the mass recovery rate decreases with the increase of resting time, and the difference of mass recovery rates for different resting times is inversely proportional to the hydraulic conductivity; 3) the sensitivity values decrease with time. The hydraulic conductivity affects not only the early period, but the later period of the breakthrough curves; 4) The influence of the hydraulic gradient on the breakthrough curves is greater at earlier stage than at later stage. The mass recovery rate is inversely proportional to the hydraulic gradient.

  • PDF

스페이서의 재질변화에 따른 전열교환기 성능변화에 관한 연구 (A Study on The Performance of a Heat Recovery Ventilator According to the Properties of Spacers)

  • 임태건;전병헌;김종원;정성학;이승갑;안영철
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.224-229
    • /
    • 2012
  • The importance of ventilation system is being emphasized by interest of indoor air quality. Especially, heat recovery ventilation system has attracted attention as most effective ventilation plan. Because it can reduce hazardous construction materials, indoor air pollutions, and also can reduce air conditioning energy cost. In heat recovery ventilator, the element core is the most important part. The element core is composed of liner and spacer. And liner and spacer are stacked alternately. On the Liner, heat and humidity transfer are made between supply and exhaust air. And spacer plays a role as a tunnel of exhaust and supply. In this study, we investigated and analyzed the efficiency of a heat recovery ventilator, when the spacer's properties are changed. As a result, difference spacer's properties affect an efficiency of heat recovery ventilator.

음 바이어스 스트레스를 받은 졸-겔 IGZO 박막 트랜지스터를 위한 효과적 양 바이어스 회복 (Effective Positive Bias Recovery for Negative Bias Stressed sol-gel IGZO Thin-film Transistors)

  • 김도경;배진혁
    • 센서학회지
    • /
    • 제28권5호
    • /
    • pp.329-333
    • /
    • 2019
  • Solution-processed oxide thin-film transistors (TFTs) have garnered great attention, owing to their many advantages, such as low-cost, large area available for fabrication, mechanical flexibility, and optical transparency. Negative bias stress (NBS)-induced instability of sol-gel IGZO TFTs is one of the biggest concerns arising in practical applications. Thus, understanding the bias stress effect on the electrical properties of sol-gel IGZO TFTs and proposing an effective recovery method for negative bias stressed TFTs is required. In this study, we investigated the variation of transfer characteristics and the corresponding electrical parameters of sol-gel IGZO TFTs caused by NBS and positive bias recovery (PBR). Furthermore, we proposed an effective PBR method for the recovery of negative bias stressed sol-gel IGZO TFTs. The threshold voltage and field-effect mobility were affected by NBS and PBR, while current on/off ratio and sub-threshold swing were not significantly affected. The transfer characteristic of negative bias stressed IGZO TFTs increased in the positive direction after applying PBR with a negative drain voltage, compared to PBR with a positive drain voltage or a drain voltage of 0 V. These results are expected to contribute to the reduction of recovery time of negative bias stressed sol-gel IGZO TFTs.

전력망 연동형 해수담수화 플랜트의 운영비용 절감효과 (The Cost Reduction Effect of Gridable Sea Water Reverse Osmosis Desalination Plant)

  • 이종현;최중인;배시화;고원석
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.64-69
    • /
    • 2011
  • A novel concept of the gridable desalination plant is to provide an operation management to enable an electricity plant operation cost reduction. Adjusting recovery rate responded to electricity price, an electricity plant operation cost can be saved. To show a suggested approach, the data of 10 [MIGD](Million Imperial Gallons per Day) SWRO testbed are used. The result shows that total cost reduction rate is calculated about 1.6[%] of annual total electric plant operation cost.

공급능력 리스크를 고려한 최적 구매계획 해법 (A Solution for Sourcing Decisions under Supply Capacity Risk)

  • 장원준;박양병
    • 대한산업공학회지
    • /
    • 제42권1호
    • /
    • pp.38-49
    • /
    • 2016
  • This paper proposes a mathematical model-based solution for sourcing decisions with an objective of minimizing the manufacturer's total cost in the two-echelon supply chain with supply capacity risk. The risk impact is represented by uniform, beta, and triangular distributions. For the mathematical model, the probability vector of normal, risk, and recovery statuses are developed by using the status transition probability matrix and the equations for estimating the supply capacity under risk and recovery statuses are derived for each of the three probability distributions. Those formulas derived are validated using the sampling method. The results of the simulation study on the test problem show that the sourcing decisions using the proposed solution reduce the total cost by 1.6~3.7%, compared with the ones without a consideration of supply capacity risk. The total cost reduction increases approximately in a linear fashion as the probability of risk occurrence or reduction rate of supply capacity due to risk events is increased.

High Performance and Low Cost Single Switch Energy Recovery Display Driver for AC Plasma Display Panel

  • Han Sang Kyoo;Moon Gun-Woo;Youn Myung Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.723-727
    • /
    • 2004
  • A new high-performance and low cost single switch energy recovery display driver for an AC plasma display panel (PDP) is proposed. Since it is composed of only one auxiliary power switch, two small inductors, and eight diodes compared with the conventional circuit consisting of four auxiliary power switches, two small inductors, eight power diodes, and two external capacitors, it features a much simpler structure and lower cost. Nevertheless, since the rootmean-square (RMS) value of the inductor current is very small, it also has very desirable advantages such as n low conduction loss and high efficiency. Furthermore, there are no serious voltage-drops caused by the large gas-discharge current with the aid of the discharge current compensation, which can also greatly reduce the current flowing through power switches and maintain the panel to light at n lower sustaining voltage. In addition, all main power switches are turned on under the zero-voltage switching (ZVS) and thus, the proposed circuit has a improved EMI, increased reliability, and high efficiency. Therefore, the proposed circuit will be well suited to the wall hanging PDP TV. To confirm the validity of the proposed circuit, circuit operations, features,and design considerations are presented and verified experimentally on a 6-inch PDP, 50kHz-switching frequency, and sustaining voltage 141V based prototype.

  • PDF