• Title/Summary/Keyword: recording prevention

Search Result 71, Processing Time 0.027 seconds

A Study on the Fire Risk of Black Box Wiring in Motor Vehicle (자동차의 블랙박스 와이어링 화재 위험성에 관한 연구)

  • Kang, Sin-Dong;Kim, Ju-Hee;Choi, Jun-Pyo;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.22-28
    • /
    • 2017
  • According to the National Fire Data System (NFDS), more than 5,000 vehicle fires have occurred every year for the last 10 years. Vehicle fires are primarily caused by mechanical (breaking system and engine), electrical (wiring and battery), and chemical (oil and fuel gas leakage) problems. The electrical factor has increased with the installation of driver convenience equipment. For example, today, the black box is widely used to provide video data recording of motor vehicle accidents. The black box consists of a front camera, rear camera, and wires. The black box wires are directly connected to the junction box or fuse box from the start battery that operates to provide normal on power supplying for engine stop. It is extremely dangerous when the wires short circuit due to insulation aging, mechanical and electrical stress, etc. In this study, the black box wiring fire risk have been analyzed and investigated when the steady state and abnormal operations, and under the following conditions: wiring arrangements with a high temperature condition, insulation aging, poor contact, and short circuits. The results showed that black box wiring short circuits had a higher fire risk than the other fire hazard elements. To prevent fire hazards caused by black box wiring, the black boxes must be installed by qualified service personnel. Do not modify the wiring, remove the fuse and secure the wiring using cable ties or insulation tape.

Development of the Nursing Practice Guidelines for Preventing Postoperative Pulmonary Complications using the Guideline Adaptation Process (수용개작방법을 활용한 전신마취 수술 후 폐합병증 예방 간호실무지침 개발)

  • Choi, Jin Ju;Kim, Hyeon Jeong;Kang, Hye Min;Chu, Hee Young;Kim, Kyeong Sug
    • Journal of Korean Clinical Nursing Research
    • /
    • v.27 no.2
    • /
    • pp.187-198
    • /
    • 2021
  • Purpose: This study aimed to develop an evidence-based nursing practice guideline for preventing postoperative pulmonary complications (PPCs). Methods: The guideline adaptation process was conducted through the 24 steps based on the guideline adaptation manual of Korean Hospital Nurses Association. Results: The newly developed guideline to prevent PPCs consisted of four domains and 30 recommendations. The number of recommendations in each domain was 7 for assessment of PPCs, 17 for nursing interventions to prevent PPCs after general anesthesia, 4 for education (intended for patients and medical staff), and 2 for monitoring and recording. Conclusion: The developed guidelines will contribute in standardization of nursing practice and PPCs prevention and management. We recommend the dissemination and utilization of these guidelines nationwide to improve the quality of postoperative pulmonary complication prevention.

Glottic Closure Reflex in an Anesthetized and Awake Canine Model (개의 성문폐쇄반사에 미치는 중추조절의 영향에 관한 연구)

  • 강주완;김광문;김영호
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.14 no.2
    • /
    • pp.83-87
    • /
    • 2003
  • Background and Objectives : Sphincteric function of the larynx, essential to lower airway protection, is most efficiently achieved through strong reflex adduction by both vocal cords. We hypothesize that central facilitation is an essential component of a bilateral adductor reflex and that its disturbance could result in weakened sphincteric closure. Materials and Method : Seven adult 20kg dogs underwent evoked response laryngeal electromyoraphy under 0.5 to 1.0 MAC isoflurane anesthesia. The internal branch of superior laryngeal nerve was stimulated through bipolar platinum-iridium electrodes and recording electrodes were positioned in the ipsilateral and contralateral thyroaryteonoid muscles. Results : Consistent threshold responses were obtained ipsilaterally under all anesthetic levels. However, contralateral reflex responses disappeared as anesthetic levels approached 1.0 MAC. Additionally, at 0.5 MAC, late responses (R2) were detected in one animal. Conclusion : Alteration of central facilitation by deepening anesthesia abolishes the crossed adductor reflex, predisposing to a weakened glottic closure response. Precise understanding of this effect may improve the prevention of aspiration in patients emerging from prolonged sedation or under heavy psychotropic control.

  • PDF

Full-Field Stress Analysis For Prevention of Failure of Agricultural Machinery

  • Wei, Sogling
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.238-246
    • /
    • 1996
  • When the important structures or components of agricultural machinery are designed, the full-filed methods of stress analysis can provide enough information in order to obtain lighter weight and prevent failure. The photoelasticity has been applicated to solve many practical engineering problems. The coating method provides full-field information, enabling the engineers to determine the complete distribution of surface strains and directly highlighting severely strained areas, especially for the welded frames of agricultural machinery. A combined method of model and prototype for strain analysis of excavator has been successfully applied to improve design. A measuring and recording system controlled by micro-computer and application software for dynamic event was studied. It can be widely used in structural failure analysis under cyclical loading . Typical application concerned stress field of crack tip and failure analysis of some mechanical structures are introduced are in roduced briefly in this paper.

  • PDF

Implementation of information sharing on a Hazard Map Creation Support System in a Traditional Local Town

  • Kozaki, Shun;Okazaki, Yasuhisa;Wakuya, Hiroshi;Mishima, Nobuo;Hayashida, Yukuo;Min, Byung-Won
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2016.05a
    • /
    • pp.237-238
    • /
    • 2016
  • This paper describes Web-based information sharing mechanism in our hazard map creation support system. This system aims at collecting the unique information received from residents and raising resident's consciousness to disasters by recording hazardous locations where residents feel danger in case of disasters. We have implemented a mechanism to share and integrate data of each terminal through a Web server. We expect that this information sharing effects scalability and usefulness of our system by utilizing collected local hazard information of each district.

  • PDF

Establishment of Criteria to Machine Trouble based on Condition Monitoring (상태감시를 기반으로 설비 트러블 발생에 대한 판정기준의 설정)

  • Kang In-Seon;Park Dong-Joon;Choi Jung-Sang
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.27 no.4
    • /
    • pp.157-164
    • /
    • 2004
  • Trouble prevention of facilities in operation process plays an important role for improving facilities productivity as production systemization is installed with development of facilities automatization. Condition monitoring predicts machine's internal changes by periodically recording vibration occurred in the machine. This article considers a method of establishing statistical criteria for facilities troubles by utilizing machine condition evaluation and operation limit standards of ISO 10816-3.

Design of Asynchronous Nonvolatile Memory Module with Self-diagnosis and Clock Function (자기진단과 시계 기능을 갖는 비동기용 불휘발성 메모리 모듈의 설계)

  • Woohyeon Shin;Kang Won Lee;Oh Yang
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.43-48
    • /
    • 2023
  • This paper discusses the design of 32Mbyte asynchronous nonvolatile memory modules, which includes self-diagnosis and RTC (Real Time Clock) functions to enhance their data stability and reliability. Nonvolatile memory modules can maintain data even in a power-off state, thereby improving the stability and reliability of a system or device. However, due to the possibility of data error due to electrical or physical reasons, additional data loss prevention methods are required. To minimize data error in asynchronous nonvolatile memory modules, this paper proposes the use of voltage monitoring circuits, self-diagnosis, BBT (Bad Block Table), ECC (Error Correction Code), CRC (Cyclic Redundancy Check)32, and data check sum, data recording method using RTC. Prototypes have been produced to confirm correct operation and suggest the possibility of commercialization.

  • PDF

Estimation of Completeness of Cancer Registration for Patients Referred to Shiraz Selected Centers through a Two Source Capture Re-capture Method, 2009 Data

  • Sharifian, Roxana;SedaghatNia, Mohammad Hossein;Nematolahi, Mohtram;Zare, Najaf;Barzegari, Saeed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.13
    • /
    • pp.5549-5556
    • /
    • 2015
  • Background: Cancer has important social consequences with cancer registration as the basis of moving towards prevention. The present study aimed to estimate the completeness of registration of the ten most common cancers in patients referred to selected hospitals in Shiraz, Iran by using capture-recapture method. Materials and Methods: This cross-sectional analytical study was performed in 2014 based on the data of 2009, on a total of 4,388 registered cancer patients. After cleaning data from two sources, using capture-recapture common findings were identified. Then, the percentage of the completeness of cancer registration was estimated using Chapman and Chao methods. Finally, the effects of demographic and treatment variables on the completeness of cancer registration were investigated. Results: The results showed that the percentages of completeness of cancer registration in the selected hospitals of Shiraz were 58.6% and 58.4%, and influenced by different variables. The age group between 40-49 years old was the highest represented and for the age group under 20 years old was the lowest for cancer registration. Breast cancer had the highest registration level and after that, thyroid and lung cancers, while colorectal cancer had the lowest registration level. Conclusions: According to the results, the number of cancers registered was very few and it seems that factors like inadequate knowledge of some doctors, imprecise diagnosis about the types of cancer, incorrectly filled out medical documents, and lack of sufficient accuracy in recording data on the computer cause errors and defects in cancer registration. This suggests a necessity to educate and teach doctors and other medical workers about the methods of documenting information related to cancer and also conduct additional measures to improve the cancer registration system.

The relationship between dental hygiene problems and dental hygiene planning according to oral health status (구강건강상태에 따른 치위생문제와 치위생계획의 연관성)

  • Kang, Hyun-Kyung;Kim, Yu-Rin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.5
    • /
    • pp.665-674
    • /
    • 2018
  • Objective: The purpose of this study was to reduce the burden on dental hygienists in performing dental hygiene processes in the clinic. This study systematically analyzed dental hygiene problems and dental hygiene planning according to the oral condition of patients by applying an oral health care program based on the dental hygiene process. Methods: This study analyzed influential factors of 17 dental hygiene problems and 12 dental hygiene plans according to the oral health index and charts of 185 patients. This study was approved by the Institutional Review Board (IRB No. 1041449-201801-HR-003) of Silla University. The frequency of dental hygiene problems and dental hygiene planning was analyzed and correlations among the oral health index, dental hygiene problems, and dental hygiene planning were analyzed. Results: The higher the bleeding on probing score was, the more scaling was planned. The higher the calculus rate was, the more air-jet and jaw joint disorder prevention education was planned. The higher the O'Leary index was, the more dietary education and air-jet was planned. The higher the Simplified Oral Hygiene Index was, the more air-jet and jaw joint disorder prevention education was planned. The higher the Periodontal Screening and Recording index was, the more scaling and professional tooth cleaning was planned (p<0.05). Conclusions: The burden of oral preventive duties on dental hygienists will be minimized by systematically establishing problems and planning of dental hygiene according to patients' oral health index scores. Therefore, it is expected that dental hygienist can actively use the dental hygiene process in oral health care programs.

Analysis of the Causes of Accidents Related to 3 Phase 170 kV Gas Insulated Switchgears(GIS) and Preventive Measures (3상 170 kV 가스절연개폐장치(GIS)의 사고 원인 분석 및 예방 대책)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.41-46
    • /
    • 2011
  • The purpose of this paper is to analyze the causes of accidents related to the 3 phase 170 kV gas insulated switchgear of a power system collected from accident sites to secure data for the prevention of similar accidents and provide important points of view regarding diagnosis for the prevention of accidents involving gas insulated switchgears. The analysis results of the causes of accidents involving gas insulated switchgears showed deformation of the manipulation lever installed at the S-phase, disconnection of the insulation rod connection, melting of the upper conductor, a damaged tulip, damage to the lower spacer and the spacer at the breaker, etc. It is believed from this result that the potential for accidents has expanded due to accumulated energy as a result of repeated deterioration. The carbonization depth of a GIS was formed near the screw (T2, T3) used to secure the lower pole of the S-phase tulip. It is not known what has caused the screws to be extruded and melted. However, it is thought that an unbalanced electromagnetic force, micro-discharge, surface discharge, etc., have occurred at that point. In addition, even though 16 years have passed since its installation, there was no installation defect, act of arson, accidental fire, etc. General periodical inspection and diagnosis failed to find the factors causing the accidents. As a system contained in a closed metal container, it has a high risk factor. Therefore, it is necessary to design, install and operate a GIS in accordance with the standard operational procedure (SOP). In addition, it is necessary to apply conversion technology for periodical SF6 gas analysis and precision safety diagnosis. It is expected that tracking and managing these changes in characteristics by recording the results on the history card will provide a significant accident prevention effect.