• Title/Summary/Keyword: reconstructed body

Search Result 167, Processing Time 0.021 seconds

A Study on the Computerization of Anthropomorphic Data (인체 형상 자료의 전산화에 관한 연구)

  • Lee, Geun-Bu
    • Journal of the Ergonomics Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.23-30
    • /
    • 1988
  • The methods suggested up to now for 3-dimensional anthroponetry require much efforts and costs in measuring and analysing. To solve these problems, we adopt the methods such as Moire Interferometry, Image processing and Computer Vision Technique which are efficient in processing anthropomorphic data. Moire contourgraph was constructed by using Ar-ion laser as a light source (2 Watt power and 5145 A wavelength) and laser beam expander(20X). Image data can be 3-dimensionally reconstructed as the surface patch and geographical relation between faces expressed by mash-point and edges as units. This research is focused on the followings; 1) Development of an economical and reliable measuring method. 2) Design of reproduction methods of 3-dimensional human body data. Therefore, our research makes it possible to study further advanced quantitative analysis of human body.

  • PDF

Clinical Significance of Radiological Stability in Reconstructed Thoracic and Lumbar Spine Following Vertebral Body Resection

  • Sung, Sang-Hyun;Chang, Ung-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.4
    • /
    • pp.323-329
    • /
    • 2014
  • Objective : Vertebral body replacement following corpectomy in thoracic or lumbar spine is performed with titanium mesh cage (TMC) containing any grafts. Radiological changes often occur on follow-up. This study investigated the relationship between the radiological stability and clinical symptoms. Methods : The subjects of this study were 28 patients who underwent corpectomy on the thoracic or lumbar spine. Their medical records and radiological data were retrospectively analyzed. There were 23 cases of tumor, 2 cases of trauma, and 3 cases of infection. During operation, spinal reconstruction was done with TMC and additional screw fixation. We measured TMC settlement in sagittal plane and spinal angular change in coronal and sagittal plane at postoperative one month and last follow-up. Pain score was also checked. We investigated the correlation between radiologic change and pain status. Whether factors, such as the kind of graft material, surgical approach, and fusion can affect the radiological stability or not was analyzed as well. Results : Mean follow-up was 23.6 months. During follow-up, $2.08{\pm}1.65^{\circ}$ and $6.96{\pm}2.08^{\circ}$ of angular change was observed in coronal and sagittal plane, respectively. A mean of cage settlement was $4.02{\pm}2.83mm$. Pain aggravation was observed in 4 cases. However, no significant relationship was found between spinal angular change and pain status (p=0.518, 0.458). Cage settlement was seen not to be related with pain status, either (p=0.644). No factors were found to affect the radiological stability. Conclusion : TMC settlement and spinal angular change were often observed in reconstructed spine. However, these changes did not always cause postoperative axial pain.

Nuclear and Microtubule Reorganization in Cattle Nuclear Transfered Embryos

  • Shin, Mi-Ra;Park, Sang-Wook;Cui, Xiang-Shun;Shim, Ho-Sup;Kim, Nam-Hyung
    • Proceedings of the KSAR Conference
    • /
    • 2001.03a
    • /
    • pp.18-18
    • /
    • 2001
  • Despite of importance of integrated events of nucleus and microtubule remodeling in nuclear transferred embryos with somatic cells, little information is available on this subject. In this study we configured chromatin and microtubule organization following somatic cell nuclear transfer in pre- and non-activated bovine oocytes in order to clearify nuclear remodeling process and to demonstrate centrosome inheritance during nuclear transfer. The cumulus-oocyte complexes were collected from slaughterhouse and were matured in vitro for 20 h in TCM 199 supplemented hormone. Matured bovine oocytes were enucleated by aspirating the frist polar body and metaphase chromatin using a beveled pipette. Bovine fibroblast cells were fused into enucleated oocyte by electrical stimulation. Reconstructed oocytes were activated with ionomycine and 6-dimethylaminopurin, and then cultured in CRlaa medium. The organization of nuclear and microtubules were observed using laser-scanning confocal microscopy. At 1 hour after fusion, microtubule aster was seen near the transferred nucleus in most oocytes regardless activation condition. While most of fibroblast nuclei remodeled to premature chromosome condensation (PCC) and to the two masses of chromosome in non-activated oocytes, a few number of fibloblasts went to PCC and multiple pronuclear like structures in activated oocytes. Microtubular spindle was seen around condensed chromosome. Gamma-tubulin was detected in the vicinity of condensed chromosome, suggesting this is a transient spindle. The spindle seperated nucleus into two masses of chromatin which developed to the pronuclear like structures. Two pronuclear like structures were than apposed by microtubular aster and formed one syngamy like nuclear structure at 15 h following nuclear transfer. At 17 to 18 h after fusion, two centrosomes were seen near the nucleus, which nucleates micrtubules for two cell cleavage. While 31% of reconstructed oocytes in non-activated condition developed to morulae and blastocysts, a few reconstructed oocytes in pre-activated condition developed to the blastocyst. These results suggested introduction of foreign centrosome during nuclear transfer, which appeared to give an important role for somatic cell nuclear reprogramming.

  • PDF

Reconstruction of a Mangled Foot with an Anterolateral Thigh Free Flap

  • Cook, Kyung Hoon;Park, Myong Chul;Park, Dong Ha;Lee, Il Jae;Song, Hyung Keun;Park, Young Uk
    • Archives of Reconstructive Microsurgery
    • /
    • v.25 no.1
    • /
    • pp.7-11
    • /
    • 2016
  • Purpose: In recent decades, amputation is still recommended for patients with extensive lower extremity wounds requiring coverage. Although the feet contribute relatively little to total body surface area, they are essential organ for ambulation, and a high mortality rate after amputation has been reported. We report on 10 challenging cases of a mangled foot which was reconstructed using an anterolateral thigh (ALT) free flap, and analyze the advantages and disadvantages of this technique. Materials and Methods: This retrospective study was conducted on 10 patients who underwent reconstructive surgery on a foot. Patients' charts were reviewed for age, sex, causes, defect size and site, flap size and type, flap type, and complications. Cases with a defect size of > $100cm^2$ were included. Results: Seven of the 10 patients were male, and overall mean age was 38.5 years (range, 22 to 61 years). Mean defect size was $179.6cm^2$ (range, 104 to $330cm^2$), and mean flap size was $193cm^2$ (range, 120 to $408cm^2$). Three cases were reconstructed with a musculocutaneous free flap and seven cases were reconstructed with a fasciocutaneous free flap. There were two occurrences of local wound complication. All ten flaps survived well, however five patients underwent a debulking procedure to reduce flap volume. Conclusion: Reconstruction of a near completely degloved soft tissue defect or a wide defect containing two or more surfaces of extremity with an ALT free flap was performed. The purpose of this case study is to report on free tissue transfer using the ALT flap for salvage of the lower extremity.

Simulation of Body Motion Caused by a Solitary Wave using the FDS-HCIB Method (FDS-HCIB법을 이용한 고립파에 의한 물체 운동 모사)

  • Shin, Sangmook;Kim, In Chul;Kim, Yong Jig
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.4
    • /
    • pp.265-273
    • /
    • 2014
  • Wave-body interaction is simulated using a developed code based on the flux-difference splitting scheme for immiscible and incompressible fluids and the hybrid Cartesian/immersed boundary method. A free surface is captured as a moving contact discontinuity within a fluid domain and an approximated Riemann solver is used to estimate the inviscid flux across the discontinuity. Immersed boundary nodes are identified inside an instantaneous fluid domain near a moving body, then dependent variables are reconstructed at those immersed boundary nodes based on interpolation along local normal lines to the boundary. Free surface flows around an oscillating cylinder are simulated and the computed wave elevations are compared with other reported results. The generation of a solitary wave by a moving wave-maker is simulated and the time histories of wave elevations at two different points are compared with other results. The developed code is applied to simulate body motion of an elastically mounted circular cylinder as a solitary wave passes the body. The force acting on an elastically mounted cylinder is compared with the force acting on a fixed cylinder. Grid independency of the computed body motion is established based on a comparison of results using three different-size grids.

Human Limbs Modeling from 3D Scan Data (3차원 스캔 데이터로부터의 인체 팔, 다리 형상 복원)

  • Hyeon, Dae-Eun;Yun, Seung-Hyeon;Kim, Myeong-Su
    • Journal of the Korea Computer Graphics Society
    • /
    • v.8 no.4
    • /
    • pp.1-7
    • /
    • 2002
  • This paper presents a new approach for modeling human limbs shape from 3D scan data. Based on the cylindrical structure of limbs, the overall shape is approximated with a set of ellipsoids through ellipsoid fitting and interpolation of fit-ellipsoids. Then, the smooth domain surface representing the coarse shape is generated as the envelope surface of ellipsoidal sweep, and the fine details are reconstructed by constructing parametric displacement function on the domain surface. For fast calculation, the envelope surface is approximated with ellipse sweep surface, and points on the reconstructed surface are mapped onto the corresponding ellipsoid. We demonstrate the effectiveness of our approach for skeleton-driven body deformation.

  • PDF

A Tele-conferncing System for Medical Dignosis based on 3D-medicl Images (3차원 의료영상 기반의 원격 진단회의 시스템)

  • Seo, Yeong-Geon;Kim, Eung-Hwan;Jeong, Mun-Ryeol;Park, Yeong-Taek;O, Hae-Seok
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.5
    • /
    • pp.1046-1058
    • /
    • 1996
  • In this paper, we describe an abvanced medical diagnostic system using multimedia technologies in netwok environments. In the system, docotors in remote sites perorm medicl diagnosis by exchanging information about patients and 3-D medicl images of malfunctioning body parts, which are reconstructed from 2-D images such as MRI, CT, CR, Angio. The diagnosic conferencing system controls the conferencing process by exchanging audio, information about patients, 3-D medical images and control data. 3-D medicl images are reconstructed by a ray casting method that uses an nalytical integration. Medical databae conists of absic information about patients, Information about medicl images, users, results of dianosis.

  • PDF

Experimental validation of smartphones for measuring human-induced loads

  • Chen, Jun;Tan, Huan;Pan, Ziye
    • Smart Structures and Systems
    • /
    • v.18 no.3
    • /
    • pp.625-642
    • /
    • 2016
  • The rapid technology developments in smartphones have created a significant opportunity for their use in structural live load measurements. This paper presents extensive experiments conducted in two stages to investigate this opportunity. Shaking table tests were carried out in the first stage using selected popular smartphones to measure the sinusoidal waves of various frequencies, the sinusoidal sweeping, and earthquake waves. Comparison between smartphone measurements and real inputs showed that the smartphones used in this study gave reliable measurements for harmonic waves in both time and frequency domains. For complex waves, smartphone measurements should be used with caution. In the second stage, three-dimensional motion capture technology was employed to explore the capacity of smartphones for measuring the movement of individuals in walking, bouncing and jumping activities. In these tests, reflective markers were attached to the test subject. The markers' trajectories were recorded by the motion capture system and were taken as references. The smartphone measurements agreed well with the references when the phone was properly fixed. Encouraged by these experimental validation results, smartphones were attached to moving participants of this study. The phones measured the acceleration near the center-of-mass of his or her body. The human-induced loads were then reconstructed by the acceleration measurements in conjunction with a biomechanical model. Satisfactory agreement between the reconstructed forces and that measured by a force plate was observed in several instances, clearly demonstrating the capability of smartphones to accurately assist in obtaining human-induced load measurements.

A Study on the Characteristics of Fluid Form Expressed in the Modern Fashion (현대 패션에 나타난 Fluid Form의 특성 연구)

  • Seo, Seung-Mi
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.4
    • /
    • pp.805-819
    • /
    • 2011
  • In contemporary society, heterotopia is the law dominates thoughts and is the concept reconstituted spaces calls order in chaos. And that is the place which refuses the paradoxical and social custom and sometimes poses a danger and rise in rebel. The purpose of this study is to study how forms of clothing fluid form images are expressed in modern fashion develop body around in the spatial relationship between the body and its environment. The study method consider changed characterastics of fluid space through the heterotopia thinking system of Foucault Michel. Based on this method, the heterotopia space that appeared in the plastic arts in aspects of artistic significance and aesthetic value was examined. Based on the above discussion on modern fashion Fluid Form were expressed in any formative characteristics were considered. The results of this study are as follows. Fluidity is the transformed interaction. It expanded external representation of organic body structure and reconstructed flexible forms of dynamic structures continuously. Transformation is the new space structure. It constructed invisible transformation and developed convertible dress space by combining a variety of functional overlap and fold. Deconstruction was expressed structural forms, expanding the existing forms in the open structure which have ambiguous boundaries.

Assessment of Attenuation Correction Algorithms With a $^{137}$Cs Point Source (Cs-137 점선원을 이용한 감쇠보정기법들에 대한 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Park, Hae-Jung;Kwon, Yun-Youn;Son, Hye-Kyoung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.96-99
    • /
    • 2004
  • The objective of this study is to assess attenuation correction algorithms utilized in a multipurpose whole-body GSO PET scanner. Four different types of phantoms were tested using different types of attenuation correction techniques. FOV (Field of View) of 256mm was used for brain PET imaging. For compensating attenuation, transmission data of a $^{137}$Cs point source were acquired after the F-18 emission source was infused to the phantoms. Scatter correction were peformed. Reconstructed images of the phantoms were assessed. In addition, reconstructed images of a normal subject were compared and assessed by nuclear medicine physicians. As a result, decreased intensity at the central portion of the attenuation map with cylindrical phantom was noticed during use of the measured attenuation correction. On the other hand, segmentation or remapping attenuation correction provided uniform phantom image. the images reconstructed from the clinical brain data explained the attenuation of a skull, at though reconstructed images of the phantoms couldn't explain it. in conclusion, the complicated and improved attenuation correction methods were required to obtain the better accuracy of the quantitative brain PET images. Our study will be useful in improving quantitative brain PET imaging modalities with attenuation correction of $^{137}$Cs transmission source.

  • PDF