• Title/Summary/Keyword: reconstructed body

Search Result 167, Processing Time 0.022 seconds

Feature Extraction and Image Segmentation of Mechanical Structures from Human Medical Images (의료 영상을 이용한 인체 역학적 구조물 특징 추출 및 영상 분할)

  • 호동수;김성현;김도일;서태석;최보영;김의녕;이진희;이형구
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.112-119
    • /
    • 2004
  • We tried to build human models based on medical images of live Korean, instead of using standard data of human body structures. Characteristics of mechanical structures of human bodies were obtained from medical images such as CT and MR images. For each constitutional part of mechanical structures CT images were analyzed in terms of gray levels and MR images were analyzed in terms of pulse sequence. Characteristic features of various mechanical structures were extracted from the analyses. Based on the characteristics of each structuring element we peformed image segmentation on CT and MR images. We delineated bones, muscles, ligaments and tendons from CT and MR images using image segmentation or manual drawing. For the image segmentation we compared the edge detection method, region growing method and intensity threshold method and applied an optimal compound of these methods for the best segmentation results. Segmented mechanical structures of the head/neck part were three dimensionally reconstructed.

  • PDF

Development of Multibody Dynamic Model of Cervical Spine for Virtual In Vitro Cadaveric Experiment (가상 생체외 사체 실험용 경추 다물체 동역학 모델 개발)

  • Lim, Dae Seop;Lee, Ki Seok;Kim, Yoon Hyuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.10
    • /
    • pp.953-959
    • /
    • 2013
  • In this study, a multibody dynamic model of the cervical spine was developed for a virtual in-vitro cadaveric experiment. The dynamic cervical spine model was reconstructed based on Korean CT images and the material properties of joints and soft tissue obtained from in-vitro experimental literature. The model was validated by comparing the inter-segmental rotation, multi-segmental rotations, load-displacement behavior, ligament force, and facet contact force with the published in-vitro experimental data. The results from the model were similar to published experimental data. The developed dynamic model of the cervical spine can be useful for injury analysis to predict the loads and deformations of the individual soft-tissue elements as well as for virtual in-vitro cadaveric experiments.

MREIT of Postmortem Swine Legs using Carbon-hydrogel Electrodes

  • Minhas, Atul S.;Jeong, Woo-Chul;Kim, Young-Tae;Kim, Hyung-Joong;Lee, Tae-Hwi;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.6
    • /
    • pp.436-442
    • /
    • 2008
  • Magnetic resonance electrical impedance tomography(MREIT) has been suggested to produce cross-sectional conductivity images of an electrically conducting object such as the human body. In most previous studies, recessed electrodes have been used to inject imaging currents into the object. An MRI scanner was used to capture induced magnetic flux density data inside the object and a conductivity image reconstruction algorithm was applied to the data. This paper reports the performance of a thin and flexible carbon-hydrogel electrode that replaces the bulky and rigid recessed electrode in previous studies. The new carbon-hydrogel electrode produces a negligible amount of artifacts in MR and conductivity images and significantly simplifies the experimental procedure. We can fabricate the electrode in different shapes and sizes. Adding a layer of conductive adhesive, we can easily attach the electrode on an irregular surface with an excellent contact. Using a pair of carbon-hydrogel electrodes with a large contact area, we may inject an imaging current with increased amplitude primarily due to a reduced average current density underneath the electrodes. Before we apply the new electrode to a human subject, we evaluated its performance by conducting MREIT imaging experiments of five swine legs. Reconstructed conductivity images of the swine legs show a good contrast among different muscles and bones. We suggest a future study of human experiments using the carbon-hydrogel electrode following the guideline proposed in this paper.

Estimation of the effect on the autonomic nervous system using the return-map (리턴맵을 이용한 자율신경계 영향 평가)

  • Jo, Heung-Kuk;Ye, Soo-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.9
    • /
    • pp.2099-2104
    • /
    • 2010
  • In this paper, HRV signal which was appeared RR intervals from ECG was analyzed using return-map during anesthesia. We intended to estimate the depth of anesthesia observing the change of autonomic nervous activity(ANS) because HRV showed change of cardio-vascular system of the body according to state of ANS. Return-map analysis is to reconstruct time series of HRV to phase space after calculating delay time and embedded time. After approximating the signal distribution which was reconstructed in phase space in elliptic, we calculated the lengths of major and minor axises of the elliptic and the values was used to estimate the depth of anesthesia. Stages of the anesthesia were 7 levels to evaluate the depth of anesthesia. At induction stage of strong external stimulation, the length of major and minor axis were statistically high and at the operation stage of non-external stimulation, the values were statistically low. Conclusively, the stages of anesthesia were discriminated by HRV signal mapped in the phase space during operation.

Reconstruction of Combined Oral Mucosa-Mandibular Defects Using the Vascularized Myoosseous Iliac Crest Free Flap

  • Jung, Hwi-Dong;Nam, Woong;Cha, In-Ho;Kim, Hyung Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.4137-4140
    • /
    • 2012
  • The authors present five cases of combined oral mucosa-mandible defects reconstructed with the vascularized internal oblique-iliac crest myoosseous free flap. This technique has many advantages compared to other conventional methods such as the radial flap, scapula flap, and fibula flap. Vascularized iliac crest flaps provide sufficient high-quality bone suitable for reconstructing segmental madibular defects. Although fibular flaps allow longer donor bone tissue to be harvested, the iliac crest can provide an esthetic shape for mandibular body reconstruction and also provides sufficient bone height for dental implants. Conventional vascularized iliac crest myoosseous flaps have excessive soft tissue bulk for reconstruction of intraoral soft tissue defects. The modification discussed in the present article can reduce soft tissue volume, resulting in better functional reconstruction of the oral mucosa. Another advantage is that complete replacement of the oral mucosa is observed in as early as one month post-operation. The final mucosal texture is much better than that obtained with other skin paddle flaps, which is especially beneficial for the placement of dental implant prostheses. Donor site morbidity looks to be similar to, if not less than that observed for other modalities in terms of function and esthetics. For combined oral mucosa-mandible defects, the vascularized internal oblique-iliac crest myoosseous free flap shows good results with respect to hard and soft tissue reconstruction.

Utility of Lateral Circumflex Femoral Artery Perforator's 3D Image with MD-CT (MD-CT로 얻은 가쪽넙다리휘돌이 관통동맥 3D 영상의 유용성)

  • Park, Soo Ho;Shim, Jeong Su;Lee, Sang Kon;Park, Dae Hwan
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.379-384
    • /
    • 2008
  • Purpose: Currently, using perforator artery flaps especially anterolateral thigh flaps are widely used for reconstruction of extremities, head and neck. Obtaining a precise anatomical picture prior to operation will translate to a more accurate, efficient and safe procedure. Authors used 3D-image work up via 64-slice MDCT to make a more precise preoperative plan. Methods: A total of 10 patients underwent soft tissue reconstruction with anterolateral thigh flap from December 2006 to December 2007. The 64-Channel MDCT (LightSpeed VCT, GE, USA) was used and 3D images were reconstructed. Findings from MDCT were applied to the preoperative planning and confirmed with intraoperative findings. Results: The average number of perforator arteries from lateral circumflex femoral artery was 2. The average lengths of vascular pedicle from the origin of lateral circumflex femoral artery to the first and second perforator artery were 11.0 cm and 20.0 cm, respectively. The average diameter of the pedicle artery was 2.2 mm. The locations of the perforator arteries were mapped and localized on the body surface based on the MDCT result. These were confirmed through direct visualization intraoperatively. Conclusion: MDCT has an advantage of obtaining accurate images of the general anatomy and even fine structures like perforator arteries. By using this state-of-the-art diagnostic imaging technique, it is now possible to make an operative plan safely and easily.

Production of Cloned Korean Native Pig by Somatic Cell Nuclear Transfer

  • Hwang, In-Sul;Kwon, Dae-Jin;Oh, Keun Bong;Ock, Sun-A;Chung, Hak-Jae;Cho, In-Cheol;Lee, Jeong-Woong;Im, Gi-Sun;Hwang, Seongsoo
    • Development and Reproduction
    • /
    • v.19 no.2
    • /
    • pp.79-84
    • /
    • 2015
  • The Korean native pig (KNP) have been considered as animal models for animal biotechnology research because of their relatively small body size and their presumably highly inbred status due to the closed breeding program. However, little is reported about the use of KNP for animal biotechnology researches. This study was performed to establish the somatic cell nuclear transfer (SCNT) protocol for the production of swine leukocyte antigens (SLA) homotype-defined SCNT KNP. The ear fibroblast cells originated from KNP were cultured and used as donor cell. After thawing, the donor cells were cultured for 1 hour with 15 ${\mu}M$ roscovitine prior to the nuclear transfer. The numbers of reconstructed and parthenogenetic embryos transferred were $98{\pm}35.2$ and $145{\pm}11.2$, respectively. The pregnancy and delivery rate were 3/5 (60%) and 2/5 (40%). One healthy SLA homotype-defined SCNT KNP was successfully generated. The recipient-based individual cloning efficiency ranged from 0.65 to 1.08%. Taken together, it can be postulated that the methodological establishment of the production of SLA homotype-defined cloned KNP can be applied to the generation of transgenic cloned KNP as model animals for human disease and xenotransplantation researches.

An Iterative Image Reconstruction Method for the Region-of-Interest CT Assisted from Exterior Projection Data (Exterior 투영데이터를 이용한 Region-of-Interest CT의 반복적 영상재구성 방법)

  • Jin, Seung Oh;Kwon, Oh-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.132-141
    • /
    • 2014
  • In an ordinary CT scan, a large number of projections with full field-of-view (FFOV) are necessary to reconstruct high resolution images. However, excessive x-ray dosage is a great concern in FFOV scan. Region-of-interest (ROI) CT or sparse-view CT is considered to be a solution to reduce x-ray dosage in CT scanning, but it suffers from bright-band artifacts or streak artifacts giving contrast anomaly in the reconstructed image. In this study, we propose an image reconstruction method to eliminate the bright-band artifacts and the streak artifacts simultaneously. In addition to the ROI scan for the interior projection data with relatively high sampling rate in the view direction, we get sparse-view exterior projection data with much lower sampling rate. Then, we reconstruct images by solving a constrained total variation (TV) minimization problem for the interior projection data, which is assisted by the exterior projection data in the compressed sensing (CS) framework. For the interior image reconstruction assisted by the exterior projection data, we implemented the proposed method which enforces dual data fidelity terms and a TV term. The proposed method has effectively suppressed the bright-band artifacts around the ROI boundary and the streak artifacts in the ROI image. We expect the proposed method can be used for low-dose CT scans based on limited x-ray exposure to a small ROI in the human body.

3D Reconstruction of a Single Clothing Image and Its Application to Image-based Virtual Try-On (의상 이미지의 3차원 의상 복원 방법과 가상착용 응용)

  • Ahn, Heejune;Minar, Matiur Rahman
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.5
    • /
    • pp.1-11
    • /
    • 2020
  • Image-based virtual try-on (VTON) is becoming popular for online apparel shopping, mainly because of not requiring 3D information for try-on clothes and target humans. However, existing 2D algorithms, even when utilizing advanced non-rigid deformation algorithms, cannot handle large spatial transformations for complex target human poses. In this study, we propose a 3D clothing reconstruction method using a 3D human body model. The resulting 3D models of try-on clothes can be more easily deformed when applied to rest posed standard human models. Then, the poses and shapes of 3D clothing models can be transferred to the target human models estimated from 2D images. Finally, the deformed clothing models can be rendered and blended with target human representations. Experimental results with the VITON dataset used in the previous works show that the shapes of reconstructed clothing are significantly more natural, compared to the 2D image-based deformation results when human poses and shapes are estimated accurately.

The Korean version of Eating Disorder Diagnostic Scale DSM-5 (K-EDDS DSM-5) : A Reliability and Validity Study (한국판 DSM-5 섭식장애진단척도(Korean version of the Eating Disorder Diagnostic Scale DSM-5, K-EDDS DSM-5) : 신뢰도와 타당도 연구)

  • Bang, Eun Byul;Han, Cho Long;Joen, Yae Lim;Kim, Youl-Ri
    • Anxiety and mood
    • /
    • v.14 no.2
    • /
    • pp.127-134
    • /
    • 2018
  • Objective : The aim of this study was to examine the psychometric features of the Korean version of the Eating Disorder Diagnostic Scale-the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (K-EDDS DSM-5). Methods : A total of 72 patients diagnosed with eating disorders participated in the study. The diagnosis was based on the Korean version of the Eating Disorder Examination (KEDE) interview. All participants completed the K-EDDS and the Eating Disorder Examination Questionnaire version 6.0 (EDE-Q 6.0) for this study. The psychometric features of the K-EDDS were examined using exploratory factor analysis, convergent validity of agreement between the K-EDDS and the KEDE, and internal consistency. Results : The exploratory factor analysis initially extracted 6-factor structures which were reconstructed into 4 factors of body dissatisfaction, binge behavior, binge frequency, and compensatory behavior based on appropriateness of the items. The internal consistency of the K-EDDS was fairly acceptable (Cronbach's alpha=0.72). The diagnostic agreement between the K-EDDS and the KEDE was high (98.61%). The 4 factors of the K-EDDS showed significant correlation with the 4 subscales of the EDE-Q 6.0. Conclusion : Our data suggests that the K-EDDS is a reliable and valid tool for the diagnosis of eating disorders based on the DSM-5.