• 제목/요약/키워드: reciprocating motion

검색결과 117건 처리시간 0.031초

Fracture incidence of Reciproc instruments during root canal retreatment performed by postgraduate students: a cross-sectional retrospective clinical study

  • Liliana Machado Ruivo;Marcos de Azevedo Rios;Alexandre Mascarenhas Villela;Alexandre Sigrist de Martin;Augusto Shoji Kato;Rina Andrea Pelegrine;Ana Flavia Almeida Barbosa;Emmanuel Joao Nogueira Leal Silva;Carlos Eduardo da Silveira Bueno
    • Restorative Dentistry and Endodontics
    • /
    • 제46권4호
    • /
    • pp.49.1-49.8
    • /
    • 2021
  • Objectives: To evaluate the fracture incidence of Reciproc R25 instruments (VDW) used during non-surgical root canal retreatments performed by students in a postgraduate endodontic program. Materials and Methods: From the analysis of clinical record cards and periapical radiographs of root canal retreatments performed by postgraduate students using the Reciproc R25, a total of 1,016 teeth (2,544 root canals) were selected. The instruments were discarded after a single use. The general incidence of instrument fractures and its frequency was analyzed considering the group of teeth and the root thirds where the fractures occurred. Statistical analysis was performed using the χ2 test (p < 0.01). Results: Seven instruments were separated during the procedures. The percentage of fracture in relation to the number of instrumented canals was 0.27% and 0.68% in relation to the number of instrumented teeth. Four fractures occurred in maxillary molars, 1 in a mandibular molar, 1 in a mandibular premolar and 1 in a maxillary incisor. A greater number of fractures was observed in molars when compared with the number of fractures observed in the other dental groups (p < 0.01). Considering all of the instrument fractures, 71.43% were located in the apical third and 28.57% in the middle third (p < 0.01). One instrument fragment was removed, one bypassed, while in 5 cases, the instrument fragment remained inside the root canal. Conclusions: The use of Reciproc R25 instruments in root canal retreatments carried out by postgraduate students was associated with a low incidence of fractures.

Comparison of vibration characteristics of file systems for root canal shaping according to file length

  • Seong-Jun Park;Se-Hee Park ;Kyung-Mo Cho ;Hyo-Jin Ji ;Eun-Hye Lee ;Jin-Woo Kim
    • Restorative Dentistry and Endodontics
    • /
    • 제45권4호
    • /
    • pp.51.1-51.10
    • /
    • 2020
  • Objectives: No studies have yet assessed vibration characteristics according to endodontic file length. Accordingly, the objective of the present study was to examine the vibration characteristics according to nickel-titanium file length and to compare these characteristics between different file systems. Materials and Methods: A total of 45 root canal models were divided into 3 experimental groups (n = 15 each) based on the file system used (ProTaper Gold [PTG], ProTaper Next, or WaveOne Gold [WOG]). Each experimental group was further divided into 3 subgroups according to file length (21, 25, or 31 mm). An electric motor (X-SMART PLUS) was used in the experiment. For each file system, vibrations generated when using a size 25 file were measured and used to calculate the average vibration acceleration. The differences in vibrations were analyzed using 1-way analysis of variance and the Scheffé post hoc test with a confidence interval of 95%. Results: In the PTG file system, significantly lower vibration acceleration was observed when using a 21-mm file than when using a 31-mm file. In the WOG file system, significantly stronger vibration acceleration was observed when using a 31-mm file than when using 21- or 25-mm files. Regardless of the file length, the WOG group exhibited significantly stronger vibration acceleration than the other 2 experimental groups. Conclusions: In clinical practice, choosing a file with the shortest length possible could help reduce vibrations. Additionally, consideration should be given to vibrations that could be generated when using WOG files with reciprocating motion.

Whole-life wind-induced deflection of insulating glass units

  • Zhiyuan Wang;Junjin Liu;Jianhui Li;Suwen Chen
    • Wind and Structures
    • /
    • 제37권4호
    • /
    • pp.289-302
    • /
    • 2023
  • Insulating glass units (IGUs) have been widely used in buildings in recent years due to their superior thermal insulation performance. However, because of the panel reciprocating motion and fatigue deterioration of sealants under long-term wind loads, many IGUs have the problem of early failure of watertight properties in real usage. This study aimed to propose a statistical method for wind-induced deflection of IGU panels during the whole life service period, for further precise analysis of the accumulated fatigue damage at the sealed part of the edge bond. By the estimation of the wind occurrence regularity based on wind pressure return period, the events of each wind speed interval during the whole life were obtained for the IGUs at 50m height in Beijing, which are in good agreement with the measured data. Also, the wind-induced deflection analysis method of IGUs based on the formula of airspace coefficient was proposed and verified as an improvement of the original stiffness distribution method with the average relative error compared to the test being about 3% or less. Combining the two methods above, the deformation of the outer and inner panes under wind loads during 30 years was precisely calculated, and the deflection and stress state at selected locations were obtained finally. The results show that the compression displacement at the secondary sealant under the maximum wind pressure is close to 0.3mm (strain 2.5%), and the IGUs are in tens of thousands of times the low amplitude tensile-compression cycle and several times to dozens of times the relatively high amplitude tensile-compression cycle environment. The approach proposed in this paper provides a basis for subsequent studies on the durability of IGUs and the wind-resistant behaviors of curtain wall structures.

다물체 동역학 시뮬레이션을 이용한 작동기용 기어박스 가속시험법 검증 (Validation of Actuator Gearbox Accelerated Test Method Using Multi-Body Dynamics Simulation)

  • 이동건;문상곤;박영준;심우람;심성보;김수철
    • 드라이브 ㆍ 컨트롤
    • /
    • 제21권1호
    • /
    • pp.22-30
    • /
    • 2024
  • Gearboxes designed for reciprocating motion operating mechanisms operate under conditions where both the load and speed undergo continuous variations. When conducting durability tests on gearboxes designed for such applications, operating the target gearbox under conditions similar to the intended usage is essential. The gearbox must be operated for the required number of cycles to validate its durability under conditions mirroring its intended usage. This study devised an accelerated test method for gearboxes, which reduces operating angles and operational strokes. The reliability of the accelerated test was verified by comparing the stresses imposed on the gears under general and acceleration conditions through multi-body dynamic simulations. The results confirmed that the maximum contact stress levels under normal and accelerated conditions were within a 0.1% error range, indicating a minimal difference in the gear damage rates. However, a difference in the maximum contact stress results between the normal and accelerated conditions was observed when inertial forces acted on the output shaft due to the operational acceleration of the gearbox. Therefore, when conducting this acceleration test, caution should be exercised to ensure that the operational load on the gearbox, which affects inertia, does not significantly deviate from the conditions observed under normal operating conditions.

고온차단 기밀용 그라파이트의 고온 미끄럼마모 특성 평가 (Sliding Wear Properties of Graphite as Sealing Materials for Cut off Hot Gas)

  • 김연욱;김재훈;양호영;박성한;이환규;김범근;이성범;곽재수
    • 대한기계학회논문집A
    • /
    • 제37권11호
    • /
    • pp.1349-1354
    • /
    • 2013
  • 고온의 가스유로를 조절하는 개폐식(On-Off)밸브의 구동축과 라이너 사이에 위치하여 구동장치로의 고온 가스유입을 방지하는 기밀 소재에 대하여 연구하였다. 기밀 소재로 사용된 그라파이트(Graphite)는 구동장치에 의한 구동축의 지속적인 움직임으로 인해 마모가 발생한다. 본 논문은 고온가스 조절 밸브 내의 기밀 소재로 사용된 그라파이트(Graphite, HK-6)에 대한 상 고온 마모 특성을 평가하였다. 구동축의 소재인 레늄합금(W-25Re)에 대하여 그라파이트의 마모 시험을 수행하고 마찰계수와 비마모율을 비교하였다. 상온과 실제 작동 환경인 고온 $485^{\circ}C$에서 미끄럼속도와 접촉하중의 변화에 따른 마찰계수와 비마모율을 평가하였다. 마모표면의 SEM 분석을 통하여 상 고온 마모표면에 관찰되는 third body 를 확인하고 이로 인한 윤활효과를 고찰하였다.

디젤엔진용 실린더 라이너 소재의 고온 마모특성 (Wear Characteristics of Cylinder-Liner Materials for Diesel Engine at Elevated Temperature)

  • 김진열;김재훈;오광근;이승학;장준용
    • 대한기계학회논문집A
    • /
    • 제39권11호
    • /
    • pp.1131-1136
    • /
    • 2015
  • 선박 디젤엔진용 실린더 라이너는 피스톤 링과 지속적인 왕복운동을 통해 마모가 발생한다. 마모는 디젤엔진의 성능을 저하시키고, 사용 수명을 단축시킨다. 본 논문은 선박 디젤엔진용 실린더 라이너의 GT 금속 및 기존 금속에 대하여 마모특성을 평가하였다. 마모시험은 상온, $175^{\circ}C$, $325^{\circ}C$의 온도조건과 10 N, 30 N, 50 N 의 하중조건에서 수행되었으며, 마모량, 비마마율 및 마찰계수를 평가하였다. 또한 각 조건에 대한 마모메커니즘을 분석하기 위해서 SEM 분석을 수행하였다. 두 금속 공히, 상온에서 연삭 및 응착마모가 진행되었고, 고온에서 부식마모가 발견되었다. GT 금속은 기존 금속 대비 모든 온도 범위에서 마모량 및 비마모율이 작고 마모특성이 더 우수하다.

구리 합금 초음파 스케일러 팁이 치과 임플란트 및 수복 재료 표면에 미치는 영향 (The effect of copper alloy scaler tip on the surface roughness of dental implant and restorative materials)

  • 이아름;정정훈;정겨운;방은경
    • 대한치과보철학회지
    • /
    • 제52권3호
    • /
    • pp.177-185
    • /
    • 2014
  • 목적: 본 연구는 구리 합금 스케일러 팁을 비롯한 수종의 스케일러 팁이 임플란트와 수복물 재료 표면에 실제 치석제거 시와 같이 적용하였을 때 표면 거칠기에 미치는 영향을 알아보고자 하였다. 재료 및 방법: 도재, 티타늄, 지르코니아, 제3형 금합금의 지름 15 mm, 높이 1.5 mm의 원반형 시편을 준비하였고, 거칠기 형성기구로 스테인리스 스틸팁(SS), 플라스틱 수동 큐렛(PS), 구리 합금 팁(IS)을 이용하였으며, 시편의 개수는 각 재료 당 기구 별로 4개씩 총 64개를 사용하였다. 표면 거칠기는 40 g의 힘으로 초음파 스케일러는 시편의 표면과 팁이 15도, 핸드 큐렛은 시편의 표면과 큐렛의 날이 45도가 되도록 하여 1초에 1회 5 mm 수평 왕복운동을 30초 동안 시행하여 형성하였다. 각 시편을 주사전자 현미경을 이용하여 관찰하였고, 원자현미경과 표면조도 거칠기 단 차 측정기를 이용하여 표면 거칠기(Ra, ${\mu}m$)를 측정하고 분석하였다. 결과: 주사전자 현미경으로 관찰 결과 표면 거칠기의 증가는 스테인리스 스틸 팁(Group SS)에서 가장 컸으며 구리 합금 팁(Group IS)에서 가장 적게 나타났다. 원자현미경으로 표면 거칠기를 측정한 결과, 스테인리스 스틸 팁(Group SS)은 도재 군과 제3형 금합금 군에서 대조군과 플라스틱 수동 큐렛(Group PS), 구리 합금 팁(Group IS)보다 표면 거칠기가 유의성 있게 크게 나타났고, 구리 합금 팁(Group IS)은 금합금 군에서는 스테인리스 스틸 팁(Group SS)과 플라스틱 수동 큐렛(Group PS)에 비해 표면 거칠기가 유의성 있게 적게 나타났다. 표면조도 거칠기 단 차 측정기로 측정 결과, 스테인리스 스틸 팁(Group SS)은 모든 군에서 대조군 및 플라스틱 수동 큐렛(Group PS)과 구리 합금 팁(Group IS)보다 표면 거칠기가 유의성 있게 크게 나타났으며, 구리 합금 팁(Group IS)은 모든 군에서 스테인리스 스틸 팁(Group SS)에 비해 표면 거칠기가 유의성 있게 적게 나타났다. 제3형 금합금은 도재, 티타늄, 지르코니아 군에 비해 치석제거 기구에 의한 표면 거칠기의 증가가 크게 나타났다(P<.05). 결론: 이상의 연구결과 새로이 개발된 구리 합금 팁(IS)을 적용하였을 때 티타늄 및 치과 수복 재료의 표면 거칠기에 영향을 주지 않음으로써, 임플란트 및 수복치료 된 치아의 치석제거 시 전통적인 스테인리스 스틸 팁(SS)의 대용품으로 유용하게 사용될 수 있을 것으로 사료된다.