• Title/Summary/Keyword: receiver setting

Search Result 60, Processing Time 0.028 seconds

Hearing loss screening tool (COBRA score) for newborns in primary care setting

  • Poonual, Watcharapol;Navacharoen, Niramon;Kangsanarak, Jaran;Namwongprom, Sirianong;Saokaew, Surasak
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.11
    • /
    • pp.353-358
    • /
    • 2017
  • Purpose: To develop and evaluate a simple screening tool to assess hearing loss in newborns. A derived score was compared with the standard clinical practice tool. Methods: This cohort study was designed to screen the hearing of newborns using transiently evoked otoacoustic emission and auditory brain stem response, and to determine the risk factors associated with hearing loss of newborns in 3 tertiary hospitals in Northern Thailand. Data were prospectively collected from November 1, 2010 to May 31, 2012. To develop the risk score, clinical-risk indicators were measured by Poisson risk regression. The regression coefficients were transformed into item scores dividing each regression-coefficient with the smallest coefficient in the model, rounding the number to its nearest integer, and adding up to a total score. Results: Five clinical risk factors (Craniofacial anomaly, Ototoxicity, Birth weight, family history [Relative] of congenital sensorineural hearing loss, and Apgar score) were included in our COBRA score. The screening tool detected, by area under the receiver operating characteristic curve, more than 80% of existing hearing loss. The positive-likelihood ratio of hearing loss in patients with scores of 4, 6, and 8 were 25.21 (95% confidence interval [CI], 14.69-43.26), 58.52 (95% CI, 36.26-94.44), and 51.56 (95% CI, 33.74-78.82), respectively. This result was similar to the standard tool (The Joint Committee on Infant Hearing) of 26.72 (95% CI, 20.59-34.66). Conclusion: A simple screening tool of five predictors provides good prediction indices for newborn hearing loss, which may motivate parents to bring children for further appropriate testing and investigations.

Field Application and Evaluation of Health Status Assessment Tool based on Dietary Patterns for Middle-Aged Women (중년 여성의 식생활 중심 건강상태 판정 도구의 현장 적용 및 평가)

  • Lee, Hye-Jin;Lee, Kyung-Hea
    • Korean Journal of Community Nutrition
    • /
    • v.23 no.4
    • /
    • pp.277-288
    • /
    • 2018
  • Objectives: This study was performed to verify the validity and judgment criteria setting of a health status assessment tool based on dietary patterns for middle-aged women. Methods: A total of 474 middle-aged women who visited the Comprehensive Medical Examination Center at Hanmaeum Hospital in Changwon were enrolled (IRB 2013-0005). The validity was verified using clinical indicators for the diagnosis of metabolic syndrome (MS), and it was used to set the criteria for the tool. A logistic regression analysis was performed for validation. The area under-receiver operation (AUC), sensitivity, specificity, and Youden Index were calculated through ROC curve analysis. Statistical analysis was performed by SPSS 21, and p value <0.05 was considered to be statistically significant. Results: The mean score of the group with no MS (73.3 points) was significantly higher compared to the group with MS (65.7 points) (p<0.001). An analysis of the association between the tool scores and risk of MS showed a 0.15-fold reduction in the risk of MS every time the tool's score increased by one point. As the result of the ROC curve analysis, the assessment reference point was set to 71 points, indicating 77.0% sensitivity and 61.0% specificity. Risk of MS was significantly higher in the group with a score of less than 71.0 than a group with more than 71 points (OR=5.28, p<0.001). Conclusions: This study was the first attempt to develop a health status assessment tool based on the dietary patterns for middle-aged women, and this tool has proven its usefulness as an MS assessment tool through the application of middle-aged women in the field of health screening.

GPS Data Collection and Application for the Analysis of Car Following Behavior (차량의 추종행태 분석을 위한 GPS 자료의 수집과 적용)

  • Woo, Yong-Han
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.3 no.4
    • /
    • pp.11-21
    • /
    • 2000
  • The travel behavior should be analysed microscopically for the traffic management of urban street. The car following theory which found out the correlation between the lead and the following vehicles is being widely used as basic data in many fields. As the vehicle position and its speed information can be received by GPS, this technique is recently applying to the various fields. For the case study the travel data were collected with two vehicles equipped with GPS receiver. The moving distance was calculated by the collected location data every 2 seconds and the speed variation was checked. And this study analysed and compared the acceleration and deceleration speed between the lead and the following vehicle. Finally, Regression model about the relationship between the acceleration and deceleration speed and the acceleration and deceleration distance was constructed. This model could be helpful for the road design and the regulation for the safe traffic management.

  • PDF

Performance Analysis of Initial Cell Search in WCDMA System over Rayleigh Fading Channels (레일리 페이딩 채널에서 W-CDMA 시스템의 초기 셀 탐색 성능 해석)

  • Song, Moon-Kyou
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.4
    • /
    • pp.1-10
    • /
    • 2001
  • The 3-step cell search has been considered for fast acquisition of the scrambling code unique to a cell in the W -CDMA system. In this paper, the performance of the cell search scheme is analyzed in Rayleigh fading channels. And the system parameters for cell search scheme and the design parameters for the receivers are examined. The probabilities of detection, miss and false alarm for each step are derived in closed forms based on the statistics of CDMA noncoherent demodulator output. Through the analysis, the effect of threshold setting and post detection integration for each step is investigated, and the optimal values of the power allocation for the synchronization channels are also considered. The number of post-detection integrations for each step is a design parameter for the receiver, and the optimum values may depend on not only the power allocation for each channel related to the cell search, but the false alarm penalty time. It is shown that optimal values could be determined through the analysis. Also, the cumulative probability distribution of the average cell search time is obtained.

  • PDF

Optimization of exposure parameters and relationship between subjective and technical image quality in cone-beam computed tomography

  • Park, Ha-Na;Min, Chang-Ki;Kim, Kyoung-A;Koh, Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.139-151
    • /
    • 2019
  • Purpose: This study was performed to investigate the effect of exposure parameters on image quality obtained using a cone-beam computed tomography (CBCT) scanner and the relationship between physical factors and clinical image quality depending on the diagnostic task. Materials and Methods: CBCT images of a SedentexCT IQ phantom and a real skull phantom were obtained under different combinations of tube voltage and tube current (Alphard 3030 CBCT scanner, 78-90 kVp and 2-8 mA). The images obtained using a SedentexCT IQ phantom were analyzed technically, and the physical factors of image noise, contrast resolution, spatial resolution, and metal artifacts were measured. The images obtained using a real skull phantom were evaluated for each diagnostic task by 6 oral and maxillofacial radiologists, and each setting was classified as acceptable or unacceptable based on those evaluations. A statistical analysis of the relationships of exposure parameters and physical factors with observer scores was conducted. Results: For periapical diagnosis and implant planning, the tube current of the acceptable images was significantly higher than that of the unacceptable images. Image noise, the contrast-to-noise ratio (CNR), the line pair chart on the Z axis, and modulation transfer function (MTF) values showed statistically significant differences between the acceptable and unacceptable image groups. The cut-off values obtained using receiver operating characteristic curves for CNR and MTF 10 were useful for determining acceptability. Conclusion: Tube current had a major influence on clinical image quality. CNR and MTF 10 were useful physical factors that showed significantly associations with clinical image quality.

Determination of Urinary Cotinine Cut-Off Point for Discriminating Smokers and Non-Smokers among Adolescents: The Third Cycle of the Korean National Environmental Health Survey (2015~2017) (청소년의 흡연자 선별을 위한 소변 중 코티닌 절사점 결정: 제3기 국민환경보건 기초조사(2015~2017))

  • Jung, Sunkyoung;Park, Sangshin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.4
    • /
    • pp.320-329
    • /
    • 2021
  • Background: Smoking exposure may be objectively assessed through specific biomarkers. The most common biomarker for smoking is cotinine concentration in urine, and setting an optimal cut-off point can accurately classify smoking status. Such a cut-off point for Korean adolescents has never been studied. Objectives: The aim of this study was to determine a cut-off point for urinary cotinine concentration for the discrimination of smoking in adolescents. Methods: Participants were adolescents aged 13~18 years who participated in the third cycle of the Korean National Environmental Health Survey. We used urine samples to confirm the level of cotinine concentrations. Smoking status was determined by self-reported questionnaire. We identified the optimal cotinine cut-off point for discriminating smoking status using receiver operating characteristic curve analysis. Results: Of the 904 participants, 28 (3.1%) were smokers, among whom 20 (71.4%) were male. The median urinary cotinine concentrations in smokers was 218 ㎍/L (male: 215 ㎍/L, female: 303 ㎍/L), and that in non-smokers was 1.31 ㎍/L (male: 1.46 ㎍/L, female: 1.18 ㎍/L). We found significant differences in urinary cotinine concentration according to smoking status and sex (p<0.001). Urinary cotinine concentrations performed well for identifying smoking adolescents [area under the curve: 0.954 (male: 0.963, female: 0.908)]. The cut-off that optimally distinguished smokers from non-smokers was 39.85 ㎍/L (sensitivity: 89.3%, specificity: 97.4%). Male [39.85 ㎍/L (sensitivity: 90.0%, specificity: 94.9%)] had a different optimal cut-off point than female [26.26 ㎍/L (sensitivity: 87.5%, specificity: 99.6%)]. Conclusions: This study determined a cut-off point for urinary cotinine of 39.85 ㎍/L (male: 39.85 ㎍/L, female: 26.26 ㎍/L) to distinguish smokers from non-smokers in adolescents.

Development of Acanthial Parieto Projection for Maxillary Diagnosis in X-ray Paranasal Sinuses (X-ray 코곁굴 검사에서 위턱굴 진단을 위한 비극-두정방향 촬영법 개발)

  • Byung-Ju Ahn;Yong-Wan Kim;In-Soo Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.327-333
    • /
    • 2023
  • In Order to Diagnose Maxillary Bone and Maxillary Sinus in the X-Ray Paranasal Sinus Projection test, this Study used Skull Rando Phantom to Change the Posture and X-ray tube Angle to 5° of the Head or 5° of ROC Who worked for more than 10 years. The Significance of the Evaluated score was Verified through SPSS Ver. 3.0, and the Cronbach value was Significantly higher at 0.712. In addition, as a Result of Calculating SNR by Setting the ROI(Receiver Operation Characteristic) of the Maxillary bone and Maxillary sinus images, it was the Highest at 6,449 in the Examination by tilting 5° toward the Head or Leg of the X-ray tube. In the study, it is believed that among the X-Ray simple Paranasal Sinus projection tests, a sharp Image can be Obtained during the Examination by Tilting the X-ray tube 5° toward the Head or Leg.

The Diagnostic Performance of the Length of Tumor Capsular Contact on MRI for Detecting Prostate Cancer Extraprostatic Extension: A Systematic Review and Meta-Analysis

  • Tae-Hyung Kim;Sungmin Woo;Sangwon Han;Chong Hyun Suh;Soleen Ghafoor;Hedvig Hricak;Hebert Alberto Vargas
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.684-694
    • /
    • 2020
  • Objective: The purpose was to review the diagnostic performance of the length of tumor capsular contact (LCC) on magnetic resonance imaging (MRI) for detecting prostate cancer extraprostatic extension (EPE). Materials and Methods: PubMed and EMBASE databases were searched up to March 24, 2019. We included diagnostic accuracy studies that evaluated LCC on MRI for EPE detection using radical prostatectomy specimen histopathology as the reference standard. Quality of studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and graphically presented using hierarchical summary receiver operating characteristic (HSROC) plots. Meta-regression and subgroup analyses were conducted to explore heterogeneity. Results: Thirteen articles with 2136 patients were included. Study quality was generally good. Summary sensitivity and specificity were 0.79 (95% confidence interval [CI] 0.73-0.83) and 0.67 (95% CI 0.60-0.74), respectively. Area under the HSROC was 0.81 (95% CI 0.77-0.84). Substantial heterogeneity was present among the included studies according to Cochran's Q-test (p < 0.01) and Higgins I2 (62% and 86% for sensitivity and specificity, respectively). In terms of heterogeneity, measurement method (curvilinear vs. linear), prevalence of Gleason score ≥ 7, MRI readers' experience, and endorectal coils were significant factors (p ≤ 0.01), whereas method to determine the LCC threshold, cutoff value, magnet strength, and publication year were not (p = 0.14-0.93). Diagnostic test accuracy estimates were comparable across all assessed MRI sequences. Conclusion: Greater LCC on MRI is associated with a higher probability of prostate cancer EPE. Due to heterogeneity among the studies, further investigation is needed to establish the optimal cutoff value for each clinical setting.

Characteristics of Ground-Penetrating Radar (GPR) Radargrams with Variable Antenna Orientation

  • Yoon Hyung Lee;Seung-Sep Kim
    • Economic and Environmental Geology
    • /
    • v.57 no.1
    • /
    • pp.17-23
    • /
    • 2024
  • Ground penetrating radar (GPR) survey is a geophysical method that utilizes electromagnetic waves reflecting from a boundary where the electromagnetic property changes. As the frequency of the antenna is about 25 MHz ~ 1 GHz, it is effective to acquire high resolution images of underground pipe, artificial structure, underground cavity, and underground structure. In this study, we analyzed the change of signals reflected from the same underground objects according to the arrangement of transceiver antennas used in ground penetrating radar survey. The antenna used in the experiment was 200 MHz, and the survey was performed in the vertical direction across the sewer and the parallel direction along the sewer to the sewer buried under the road, respectively. A total of five antenna array methods were applied to the survey. The most used arrangement is when the transmitting and receiving antennas are all perpendicular to the survey line (PR-BD). The PR-BD arrangement is effective when the object underground is a horizontal reflector with an angle of less than 30°, such as the sewer under investigation. In this case study, it was confirmed that the transmitter and receiver antennas perpendicular to the survey line (PR-BD) are the most effective way to show the underground structure. In addition, in the case where the transmitting and receiving antennas are orthogonal to each other (XPOL), no specific reflected wave was observed in both experiments measured across or parallel to the sewer. Therefore, in the case of detecting undiscovered objects in the underground, the PR-BD array method in which the transmitting and receiving antennas are aligned in the direction perpendicular to the survey line taken as a reference and the XPOL method in which the transmitting and receiving antennas are orthogonal to each other are all used, it can be effective to apply both of the above arrangements after setting the direction to 45° and 135°.

A study on the hybrid communication system to remove the communication shadow area for controller system of navigational aids (전파 음영지역 해소를 위한 항로표지관리용 하이브리드 통신 시스템에 관한 연구)

  • Jeon, Joong Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.409-417
    • /
    • 2013
  • Mu-communication board supported by multi-communication is designed with Atxmega 128A1 which is a low power energy consuming of 8-bit microcontroller. ATxmega128A1 microcontroller consists of 8 UART(Universal asynchronous receiver/transmitter) ports which can be setting appropriate user interface having command line interpreter(CLI) program with each port, 2 kbytes EEPROM, 128 kbytes flash memory, 8 kbytes SRAM. 8 URAT ports are used for the multi communication modem, GPS module, etc. and EEPROM is used for saving a configuration for program running, and flash memory of 128 kbytes is used for storing a Firm Ware, and 8 kbytes SRAM is used for stack, storing memory of global variables while program running. If we uses the hybrid communication of path optimization of VHF, TRS and CDMA to remote control AtoN(aid to navigation), it is able to remove the communication shadow area. Even though there is a shadow area for individual communication method, we can select an optimum communication method. The compatibility of data has been enhanced as using of same data frame per communication devices. For the test, 8640 of data has been collected from the each buoy during 30 days in every 5 minutes and the receiving rate of the data has shown more than 99.4 %.