• 제목/요약/키워드: real time fluid animation

검색결과 11건 처리시간 0.023초

전산유체역학을 이용한 실시간 유체 애니메이션 기술 (Real-time Flow Animation Techniques Using Computational Fluid Dynamics)

  • 강문구
    • 한국가시화정보학회지
    • /
    • 제2권2호
    • /
    • pp.8-15
    • /
    • 2004
  • With all the recent progresses in computer hardware and software technology, the animation of fluids in real-time is still among the most challenging issues of computer graphics. The fluid animation is carried out in two steps - the physical simulation of fluids immediately followed by the visual rendering. The physical simulation is usually accomplished by numerical methods utilizing the particle dynamics equations as well as the fluid mechanics based on the Navier-Stokes equations. Particle dynamics method is usually fast in calculation, but the resulting fluid motion is conditionally unrealistic. The methods using Navier-Stokes equation, on the contrary, yield lifelike fluid motion when properly conditioned, yet the complexity of calculation restrains this method from being used in real-time applications. This article presents a rapid fluid animation method by using the continuum-based fluid mechanics and the enhanced particle dynamics equations. For real-time rendering, pre-integrated volume rendering technique was employed. The proposed method can create realistic fluid effects that can interact with the viewer in action, to be used in computer games, performances, installation arts, virtual reality and many similar multimedia applications.

  • PDF

입자 동역학 시뮬레이션과 선적분 볼륨 렌더링을 이용한 실시간 유체 애니메이션 (Real-time Fluid Animation using Particle Dynamics Simulation and Pre-integrated Volume Rendering)

  • 이정진;강문구;김동호;신영길
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제32권1호
    • /
    • pp.29-38
    • /
    • 2005
  • 유체 애니메이션은 물리적 시뮬레이션과 시각적 렌더링으로 구성된다. 물리적 시뮬레이션은 입자 동역학을 이용한 해석 방법과 나비어-스토크스(Navier-Stokes) 방정식을 이용한 연속체 유동해석 방법이 많이 사용된다. 입자 동역학을 이용한 시뮬레이션은 연산 속도는 빠르나 유체의 움직임이 경우에 따라 부자연스러우며, 나비어-스토크스 방정식을 이용한 방법은 적절한 조건 하에서 사실적인 유체의 움직임을 표현할 수 있으나 방대한 연산량과 계산의 복잡성으로 인하여 실시간 응용이 어렵다. 우수한 품질의 렌더링 영상은 주로 전역적 조명 방법을 사용하여 얻을 수 있는데, 이 역시 실시간 응용에 적합한 속도론 내기에는 부적합하다. 본 논문에서는 개선된 입자 동역학 시뮬레이션과 선적분 볼륨 렌더링을 이용한 고속유체 애니메이션 방법을 제안한다 레나드-존스(Lennard-Jones) 모턴을 이용한 입자동역학 해석기법을 이용하여 유체의 움직임을 고속으로 시뮬레이션 하였으며, 적은 수의 입자만으로도 충분한 유체의 부피를 표현할 수 있도록 연산효율을 개선하였다. 또한 실시간 렌더링을 위하여 적은 수의 슬라이스로도 우수한 품질의 영상을 빠르게 얻을 수 있는 선적분 볼륨 렌더링 방식을 사용하였다. 본 제안 방법을 사용하여 실시간 응용에 적절한 속도와 화질을 보여주는 유체 애니메이션이 가능하다.

키-프레임 기반 실시간 유체 시뮬레이션 (Key-Frame Based Real-Time Fluid Simulations)

  • 유지현;박상훈
    • 한국멀티미디어학회논문지
    • /
    • 제9권11호
    • /
    • pp.1515-1528
    • /
    • 2006
  • 물리기반 유체 애니메이션 시스템들이 시각 특수효과 산업계에서 빠르게 발전하고 있고, 이를 이용해 매우 높은 화질의 영상을 제작하는 것이 가능하게 되었다. 그러나 컴퓨터 게임과 같은 실시간 응용 분야의 경우, 화질보다는 시뮬레이션 속도가 더 중요한 문제이다. 본 논문은 프로그래머블 그래픽스 파이프라인을 이용하여 유체에 대한 애니메이션을 수행하는 실시간 기법에 대해 설명한다. 두 개의 키-프레임이 주어졌을 때, 본 기법을 이용하여 원시 프레임으로부터 목적 프레임으로 변하는 연속 영상을 대화식으로 생성할 수 있음을 보인다.

  • PDF

유체 애니메이션과 Smart Fish을 이용한 실감형 가상수족관 구축에 관한 연구 (A Study on Building an Immersive Virtual Aquarium Using Fluid Animation and Smart Fish Method)

  • 이현철
    • 한국멀티미디어학회논문지
    • /
    • 제12권1호
    • /
    • pp.130-138
    • /
    • 2009
  • 컴퓨터와 함께 많은 시간을 보내는 현대인들 중에는 바탕화면과 화면보호기로 마음의 편안함을 주는 자연풍경이나 가상수족관 등을 설정하는 사용자들이 증가하고 있다. 가상수족관은 임의의 가상 해저환경에서 자유롭게 행동하는 여러 종류의 물고기를 만들고, 동작을 분석하여, 물고기들의 애니메이션 작업을 수행함으로써 만들어진다. 본 논문에서는 유체의 형태변화를 실시간으로 표현하는 유체 애니메이션 기법과 가상물고기의 다양한 속성에 따라 상호작용을 할 수 있는 Smart Fish기술을 이용하여 활용가치가 높은 실감형 가상수족관을 구축하는 방법을 제안했다. 본 논문에서 제안하는 방법은 다양한 해저환경을 표현하는 가상수족관, 수족관 화면 보호기, 물고기 육성 게임 등에 활용되어질 수 있다.

  • PDF

모바일 환경에서 불꽃의 실시간 시뮬레이션과 렌더링 (Realtime Fire Simulation and Rendering on Mobile Environment)

  • 우상혁;조미리나;박동규
    • 한국멀티미디어학회논문지
    • /
    • 제10권7호
    • /
    • pp.934-943
    • /
    • 2007
  • 컴퓨터 그래픽스 분야에서 다뤄지는 유체 시뮬레이션은 사실적인 애니메이션에 있어서 필수적인 요소이기는 하지만 그 계산량이 너무 많아서 실시간 시뮬레이션과 렌더링을 위해서는 많은 시스템 자원을 필요로 하여 주로 PC 환경에서 수행되어 왔다. 최근 휴대 전화의 성능이 빠르게 발전함에 따라 3D 게임과 같은 고급 콘텐츠를 모바일 환경에서 사용 가능하게 되었다. 본 논문에서는 PC 환경보다 비교적 성능이 제한적인 모바일 장치에서 위피 플랫폼의 MF3D API를 사용하여 실시간 유체 시뮬레이션을 구현하였다. 유체 시뮬레이션을 구현하기 위하여 나비에-스토크스 식의 풀이가 필요하며, 빠르고 안정적으로 수치해를 시뮬레이션하기 위해서 Stam의 Stable Fluid 기법을 빌보드에서 구현하여 사용하였다. 시뮬레이션 결과는 빌보드 기법을 통해 화면에 나타냈으며, "루피 스토리"라는 모바일 3D 게임 콘텐츠에 적용하였다.

  • PDF

간략화된 유체 표면모델을 이용한 강체와 유체의 상호작용 시뮬레이션 (Interactive Simulation between Rigid body and Fluid using Simplified Fluid-Surface Model)

  • 김은주
    • 한국멀티미디어학회논문지
    • /
    • 제12권2호
    • /
    • pp.323-328
    • /
    • 2009
  • 게임이나 가상현실 등에서 사용자들에게 사실성과 몰입 감을 주기 위해서 자연 현상들을 시뮬레이션하고 있다. 게임이나 가상현실에서 물이나 바다와 같은 유체를 3차원으로 시뮬레이션 하는데 있어서 중요한 요소는 실시간 처리와 사실성이다. 유체 모델은 특정 상황에 따른 다양한 방정식과 많은 파라미터 값에 의해 제어되기 때문에 시뮬레이션 하는데 많은 어려움이 따른다. 또한 복잡한 물리 수식을 기반으로 하기 때문에 유체 모델을 시뮬레이션하기 위해서는 많은 수행 시간이 소요된다. 본 논문에서는 실시간 유체와 강체(rigid body) 사이의 상호작용을 표현하기 위해 간략화 된 유체 표면 모델(Fluid-Surface Model)을 제안하고, 개선된 계산과정을 통해 보다 빠르게 시뮬레이션 하도록 한다. 또한 본 논문에서는 유체의 표면과 강체의 상호작용을 표현하는데 있어서 유체의 항력에 의해서 강체와 충돌 시 발생하는 유체 표면의 움직임을 나타낸다. 본 논문에서 제안하는 자연스러운 유체 표면 모델은 유체역학적 방법을 사용하여 실시간에 사실적으로 표현된다. 그리고 이러한 유체 표면 모델을 PC 환경에서 사용자와 상호작용 가능하도록 재현하여, 게임이나 애니메이션에서의 유체 모델들에도 적용할 수 있다.

  • PDF

선형 컨벌루션과 경계구를 이용한 물표면과 객체의 실시간 상호작용 생성 (Interaction between Water Surface and 3D Object by using Linear Convolution and Bounding Sphere)

  • 강경헌;이현철;허기택;김은석
    • 한국콘텐츠학회논문지
    • /
    • 제8권4호
    • /
    • pp.17-29
    • /
    • 2008
  • 컴퓨터 그래픽스에서 물을 애니메이션하거나 다양한 특수효과를 표현하기위해 유체역학의 기술들이 사용되고 있다. 하드웨어성능이 높아지면서 이전에 불가능했던 알고리즘들이 실시간으로 가능해지고 있기는 하지만, 정밀한 표현에는 여전히 많은 시간이 소요되며, 성능과 사실성 사이의 균형을 위한 다양한 기술들이 연구되고 있다. 특히 게임과 같은 문맥을 가지는 곳에서 사용자의 요구에 의해 바다나 호수 같은 넓은 지역의 물표면과 객체의 상호작용을 표현하기 위해서는, 물리적 사실성을 어느 정도 희생하더라도 시각적인 사실성을 유지하는 범위에서 실행 성능을 높이는 것이 우선시 된다. 본 논문에서는 물표면과 객체의 상호작용에 의한 다양한 물표면의 형태변화를 선형 컨벌루션 기법과 경계구를 이용하여 실시간으로 자연스럽게 애니메이션하는 방법을 제안한다.

선형 컨벌루션 기반의 물표면과 객체의 실시간 상호작용 애니메이션 (Linear Convolution Based Realtime Animation of Interaction bewteen Water Surface and 3D object)

  • 강경헌;허기택;김은석
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2007년도 추계 종합학술대회 논문집
    • /
    • pp.708-712
    • /
    • 2007
  • CG에서 물을 애니메이션하거나 다양한 특수효과를 표현하기위해 유체역학의 기술들이 사용되고 있다. H/W 성능이 높아지면서 이전에 불가능했던 알고리즘들이 실시간으로 가능해지고 있기는 하지만, 정밀한 표현에는 여전히 많은 시간이 소요되며, 성능과 사실성 사이의 균형을 위한 다양한 기술들이 연구되고 있다. 특히 게임과 같은 문맥을 가지는 곳에서 사용자의 요구에 의해 바다나 호수같은 넓은 지역의 물표면과 객체의 상호작용을 표현하기위해서는, 물리적 사실성을 어느 정도 희생하더라도 시각적인 사실성을 유지하는 범위에서 실행성능을 높이는 것이 우선시 된다. 본 논문에서는 물표면과 객체의 상호작용에 의한 다양한 물표면의 형태변화를 선형 컨벌루션 기법과 경계구를 이용하여 실시간으로 자연스럽게 애니메이션하는 방법을 제안한다.

  • PDF

사실적 연기 시뮬레이션을 위한 Semi-Lagrange 방법에서의 이류항 계산방법 개선 (Improved Calculation of the Advection Term in the Semi-Lagrange Method for Realistic Smoke Simulation)

  • 박수완;장문희;김은주;유관우
    • 정보처리학회논문지A
    • /
    • 제14A권4호
    • /
    • pp.191-196
    • /
    • 2007
  • 자연 현상에서 나타나는 연기나 난류의 움직임을 사실적으로 시뮬레이션하기 위해서는 Navier-Stokes 방정식을 사용할 수 있다. 이 방정식을 이용한 구현은 방대한 연산량과 계산의 복잡성으로 인하여 실시간 시뮬레이션이 어렵다. 실시간 처리를 위해서는 Navier-Stokes 방정식의 관사 형태를 사용하는 것이 일반적이다. 유체 시뮬레이션의 이류(advect) 과정을 근사화하기 위해, Semi-Lagrangian 방법을 이용하면, 연기 시뮬레이션의 경우는 시간이 지남에 따라 밀도가 현저히 줄어들고, 소규모의 소용돌이(small-scale vorticity) 현상 등을 표현하기가 어렵다. 본 논문에서는 이 문제를 해결하기 위해 이류항(advection term)을 계산하는 새로운 수치해석 방법을 제안한다. 이 방법에서는 이류항의 값을 구할 때, 격자(grid) 중심의 현재 속도에 비례하는 임계영역을 격자 주변에 선정하고, 임계영역 내에 있는 격자들 중에서 현재 격자의 위치로 이류하는 속도를 가진 격자를 추적하여, 그 격자에서의 속도를 현재 격자의 이류속도 벡터로 사용한다. 이는 밀도와 소용돌이 현상의 수치적 소실을 줄여서, 사실성을 높이면서도, 실시간 처리가 가능하다. 본 논문에서는 GPU 구현을 통해 벡터 연산 등의 효율성을 높임으로써, 제안하는 방법의 실시간이 가능함을 보인다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF