• 제목/요약/키워드: reaction mode

검색결과 487건 처리시간 0.021초

Simultaneous Determination of Statins in Human Urine by Dilute-and-Shoot-Liquid Chromatography-Mass Spectrometry

  • Jang, Haejong;Mai, Xuan-Lan;Lee, Gunhee;Ahn, Jae Hyoung;Rhee, Jongsook;Truong, Quoc-Ky;Vinh, Dinh;Hong, Jongki;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • 제9권4호
    • /
    • pp.95-99
    • /
    • 2018
  • An innovative, simple, and rapid assay method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the simultaneous determination of eight statin drugs in human urine. A simple sample clean-up procedure using the "dilute and shoot" (DAS) approach enabled a fast and reliable analysis. The influence of the dilution factor was investigated to ensure detectability and reduce the matrix effect. Chromatographic separation was performed on a Phenomenex Kinetex C18 column ($50{\times}3.0mm$ i.d., $2.6{\mu}m$) using an elution gradient of mobile phase A composed of 0.1% acetic acid, and mobile phase B composed of acetonitrile, at a flow rate of 0.35 mL/min. Quantitation was performed on a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using electrospray ionization in positive ion mode. The total chromatographic run time was 15 min. The method was validated for selectivity, sensitivity, recovery, linearity, accuracy, precision, and stability. The present method was successfully applied to the analysis of Rosuvastatin in urine samples after oral administration to healthy human subjects.

Simultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control

  • Kwak, Young Beom;Yu, Jundong;Yoo, Hye Hyun
    • Mass Spectrometry Letters
    • /
    • 제13권4호
    • /
    • pp.158-165
    • /
    • 2022
  • Many therapeutic class drugs such as beta-blocker, corticosteroids, NSAIDs, etc are prohibited substances in the horse racing industry. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology makes it possible to isolate drugs from interference, enables various drug analyses in complex biological samples due to its sensitive sensitivity, and has been successfully applied to doping control. In this paper, we describe a rapid and sensitive method based on solid-phase extraction (SPE) using solid phase cartridge and LC-MS/MS to screen for different class's 35 drug targets in equine plasma. Plasma samples were pretreated by SPE with the NEXUS cartridge consisted non-polar carbon resin and minimum buffer solvent. Chromatographic separation of the analytes was performed on ACQUITY HSS C18 column (2.1 × 150 mm, 1.8 ㎛). The elution gradient was conducted with 5 mM ammonium formate (pH 3.0) in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min. The selected reaction monitoring (SRM) mode was used for drug screening with multiple transitions in the positive ionization mode. The specificity, limit of detection, recovery, and stability was evaluated for validation. The method was found to be sensitive and reproducible for drug screening. The method was applied to plasma sample analysis for the proficiency test from the Association of Racing Chemist.

Analysis of sorbic acid in tea-drink using isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) (동위원소희석 액체 크로마토그래피-질량분석법을 이용한 차음료 중의 소르빈산의 분석)

  • Ahn, Seong-Hee;Lee, In-Sun;Kim, Byung-Joo
    • Analytical Science and Technology
    • /
    • 제25권1호
    • /
    • pp.25-32
    • /
    • 2012
  • Isotope dilution mass spectrometry (ID-MS) based on liquid chromatography tandem mass spectrometry (LC/MS/MS) was developed for the accurate determination of sorbic acid in tea-drink. An isotope analogue of sorbic acid, $^{13}C_2$-sorbic acid, was obtained by custom synthesis. MS was operated in the negative mode with selected reaction monitoring (SRM) mode of $[M-H]^-$ ${\rightarrow}$ $[M-CO_2H]^-$ channel at m/z 111 ${\rightarrow}$ 67 for sorbic acid and at m/z 113 ${\rightarrow}$ 68 for its isotope analogue. Chromatographic separation was accomplished with a C18 column and an isocratic mobile phase of 55% of 50 mM ammonium acetate (pH 4.5) and 45% of methanol. Homogeneous reference materials were prepared for validation of this method, including repeatability and reproducibility tests, by fortifying tea-drink with sorbic acid in our laboratory. Repeatability and reproducibility studies showed that the ID-LC/MS method is a reliable and reproducible method which provides less than 3.8% of relative standard deviation (RSD) for the analysis of sorbic acid.

Analysis of clenbuterol in bovine muscle and milk by LC-ESI/MS/MS (LC-ESI/MS/MS를 이용한 소고기와 우유에서의 클렌부테롤 분석)

  • Hong, Selyung;Jeong, Jiyoon;Park, Hyejin;Lee, Soonho;Lee, Jongok
    • Analytical Science and Technology
    • /
    • 제21권6호
    • /
    • pp.535-542
    • /
    • 2008
  • A liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) method was developed for the determination and confirmation of clenbuterol in bovine muscle and milk. Clenbuterol and clenbuterol-D9 using as an internal standard in samples were extracted with ethyl acetate after hydrolysis and evaporated to dryness. The extracts were dissolved in 20% methanol and cleaned using HLB solid-phase extraction cartridge. The analytes were detected by LC-ESI/MS/MS on a $C_{18}$ column. Mass spectral acquisition was done in selected reaction monitoring (SRM) in positive ion mode to provide a high degree of sensitivity. Using MS/MS with SRM mode, the transitions (precursor to product) monitored were m/z 277${\rightarrow}$203 for clenbuterol, and m/z 286${\rightarrow}$204 for internal standard. The limits of quantitation (LOQ) and mean recoveries of clenbuterol in bovine muscle were $0.2{\mu}g/kg$ and 84.3~91.1%, respectively. The LOQ and mean recoveries in milk were $0.05{\mu}g/kg$ and 87.7~98.3%, respectively.

Qunatitative analysis of liquiritin and glycyrrhizin in glycyrrhizae radix by HPLC-MS/MS (HPLC-MS/MS에 의한 감초의 liquiritin과 glycyrrhizin의 분석)

  • Yu, Young-Beob;Kim, Mi-Jung;Huang, Dae Sun;Ha, Hye-Kyeong;Ma, Jin-Yeul;Shin, Hyeun-Kyoo
    • Analytical Science and Technology
    • /
    • 제20권4호
    • /
    • pp.331-338
    • /
    • 2007
  • Licorice, Glycyrrhizae Radix is widely used as a herbal medicines and a dietary supplements in East Asia. We employed high performance liquid chromatography electrospray ionization tandem mass spectrometry to determine liquiritin and glycyrrhizin in the Glycyrrhizae Radix. Liquiritin and glycyrrhizin in Glycyrrhizae Radix were ionized by positive ion pneumatically assisted electrospray and detected by HPLC-MS/MS in the multiple-reaction monitoring (MRM) mode using precursor ${\rightarrow}$ product ion combinations at m/z $436.2{\rightarrow}257.0$ and $823.4{\rightarrow}453.4$, respectively. The assay had a calibration range from 10 to 3,000 ng/mL. The limits of detection (LOD) of the liquiritin and glycyrrhizin were 0.4 ng/mL and 0.01 ng/mL, respectively. The reproducibility and repeatability (relative standard deviation) at different analyte concentrations varied from 103 to 113 % and 0.95 to 1.8 %, respectively. According to the above results, HPLC-MS/MS method permits assignment of tentative structures such as liquiritin and glycyrrhizin in the Glycyrrhizae Radix.

Degradation of Membrane With Pinholes in PEMFC (고분자 전해질 연료전지에서 Pinhole 있는 막의 열화)

  • Kim, Tae-Hee;Lee, Ho;Lim, Tae-Won;Park, Kwon-Pil
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제19권2호
    • /
    • pp.103-110
    • /
    • 2008
  • The most failure mode of PEM fuel cell is gas crossover caused by pinhole formation in MEAs. The degradation phenomena of MEA with pinholes were evaluated in various accelerated operation condition, such as OCV, low humidity and high partial pressure of oxygen. The performances of MEA with pinholes were almost same before and after normal 144 hours operation($70^{\circ}C$, $640mA/cm^2$, 65%RH $H_2/air$). The results of accelerated operation showed that OCV and low humidity condition more deteriorated MEA than gas crossover owing to pinholes. When oxygen was used as cathode gas, the pinholes of MEA were enlarged due to heat of combustion reaction on Pt catalyst of electrodes. This combustion reaction occurred at pinholes near gas inlet and resulted in local MEA failure.

On the Contact Behavior Analysis and New Design of High Pressure Piston Seals

  • Kim, Chung-Kyun;Cho, Seung-Hyun;Kim, Sung-Won;Ko, Young-Jin;Kim, Jong-Soo
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.117-119
    • /
    • 2002
  • In this paper, the geometry effectiveness and contact modes as functions of real contact length on a cap ring have been analyzed for high pressure sealing mechanism in reciprocating actuator. The reaction force and elastic strain energy density are very important parameters for analyzing the sealing performance of an ACGT ring seal. For the high pressure of 800bar and the maximum speed of 3m/s, the main piston is reciprocating along the linear line against the cylinder wall. The computed results indicate that the length ratio of a cap ring is more influential design parameter compared to that of the tribological contact mode. Thus, this paper recommends the discrete contact area rather than a conventional flat contact model. Especially, the sealing capacity is more improved when the length ratio of a cap ring is below 0.625.

  • PDF

Control of a Unicycle Robot using a Non-model based Controller (비 모델 외바퀴 로봇의 제어)

  • An, Jae-Won;Kim, Min-Gyu;Lee, Jangmyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제20권5호
    • /
    • pp.537-542
    • /
    • 2014
  • This paper proposes a control system to keep the balance of a unicycle robot. The robot consists of the disk and wheel, for balancing and driving respectively, and the tile angle is measured and used for balancing by the IMU sensor. A PID controller is designed based on a non-model based algorithm to prove that it is possible to control the unicycle robot without any approximated linear system model such as the sliding mode control algorithm. The PID controller has the advantage that it is simple to design the controller and it does not require an unnecessary complex formula. In this paper, assuming that the pitch and roll axis are dynamically decoupled, each of the two controllers are designed separately. A reaction wheel pendulum method is used for the control of the roll axis, that is, for balancing and an inverted pendulum concept is used for the control of the pitch axis. To confirm the performance of the proposed controllers using MATLAB Simulink, the dynamic equations of the robot are derived.

Quantum Mechanical Investigation on the Intermediates of Alkene-Ozone Reaction (알켄-오존 반응의 중간 생성물에 대한 ab initio 양자역학적 고찰)

  • Kang, Chang Deok;Kim, Seung Jun
    • Journal of the Korean Chemical Society
    • /
    • 제42권2호
    • /
    • pp.161-171
    • /
    • 1998
  • The geometrical parameters, vibrational frequencies, and IR intensities for primary ozonide (POZ), secondary ozonide (SOZ) and carbonyl oxide as the intermediates of alkene-ozone reaction have been predicted using high level ab initio quantum mechanical method with various basis sets. In general, the polarization function decreases bond lengths and bond angles, while the electron correlation effect increases bond lengths slightly. The electronic structure of carbonyl oxide has been predicted to be zwitterionic structure and energy difference between zwitterionic and diradical structure is evaluated to be 22.4 kcal/mol at TZ2P CISD level of theory. The experimental vibrational frequencies and IR intensities of POZ and SOZ will be compared and discussed with our high level theoretical predictions.

  • PDF

Some Kinetic Properties of an Extracellular Chitinase from Streptomyces sp, 115-5 (Streptomyces속 115-5 균주로부터 생성된 Chitinase의 저해작용기작)

  • Hong, Yong-Ki;Seu, Jung-Hwn
    • Microbiology and Biotechnology Letters
    • /
    • 제9권4호
    • /
    • pp.179-183
    • /
    • 1981
  • An extracellular chitinase was purified from the culture fluid of Streptomyces sp. 115-5, and its inhibition mechanism by end product was studied. The activity of chitinase was suppressed by the reducing sugar as the reaction proceeded, and the activity was inhibited by the addition of D-glucose. Besides D-glucose, the rate of chitin hydrolysis was inhibited by D-glucuronic acid, D-sorbitol and D-xylose in the reaction system of the enzyme. it was found that the hydroxyl groups at the C-2, C-3 and C-4 position of D-glucose molecule play an important role in the inhibition of the chitinase activity. D-glucose was found to inhibit the enzyme activity by mixed type of competitive and non-competitive mode.

  • PDF