• 제목/요약/키워드: reach forward

검색결과 66건 처리시간 0.026초

운동전략이 기립자세의 기능적 전방 팔뻗기에 미치는 영향 (Effects of the Movement Strategies on Functional Forward Reach in Standing)

  • 박제상;권오윤;최흥식;김택훈
    • 한국전문물리치료학회지
    • /
    • 제7권1호
    • /
    • pp.46-54
    • /
    • 2000
  • The purpose of this study is to determine whether movement strategies affect functional forward reach distance in a standing position. Forty-seven healthy subjects were selected for this study: 23 men and 24 women, with an average age of 22.3. Functional forward reach distances were measured as hip strategy and squat strategy (included knee and ankle movement strategy) in a standing position, respectively. The mean values of functional forward reach distance in hip strategy, squat strategy were 33.57 cm, 29.48 cm, respectively. There was significantly difference in functional forward reach distance between hip strategy and squat strategy(p<.001). There was no difference of functional forward reach distance between male and female in hip strategy, but there was significant difference in other strategy(p<.05). These results suggest that movement strategies should be considered during functional forward reach test in standing. Further study is required to determine whether movement strategies affect functional reach distance in elderly and disabled groups.

  • PDF

Effect of Elastic Aids (Bands) on Functional Reach Test in Patients with Spinal Cord Injury: Pilot Study

  • Jong Ho Kang;Tae Sung Park
    • The Journal of Korean Physical Therapy
    • /
    • 제34권6호
    • /
    • pp.317-320
    • /
    • 2022
  • Purpose: This study aimed: to confirm the balance ability of patients with spinal cord injury in the sitting state through a functional reach test using an elastic aid; and to propose a balance improvement plan. Methods: The study evaluated seven patients with spinal cord injury who could maintain a sitting posture through minimum assistance. A functional reach test was performed before and after wearing an elastic aid while sitting on a chair, and the effects before and after use of the elastic aid were compared and analyzed through a motion analyzer. Results: In the functional reach test, the forward movement distance of the hand was 97.45 mm before wearing the elastic aid, but significantly increased to 131 mm after wearing the aid (p<0.05). Corresponding forward movement distances for the shoulder were 81.26 mm and 113 mm (p<0.05 for the increase). There was no statistically significant change in lateral functional arm extension. Conclusion: It was confirmed, through a functional reach test, that trunk stability in patients with spinal cord injury increased with use of an elastic aid. In future, more efficient rehabilitation treatment programs will be possible if trunk stability in patients with spinal cord injury is improved by using elastic aids, and if various exercise treatments are also included in the rehabilitation programs.

팔 동작에 따른 소매유무별 블라우스의 착의 공극량 변화 (A Change of the Gap in Dressed Blouses with Above-elbow Sleeves and Sleeveless According to Arm Movements)

  • 이명희
    • 한국의류학회지
    • /
    • 제34권11호
    • /
    • pp.1779-1785
    • /
    • 2010
  • The experiment is designed to create some useful data on the dressed shapes that contribute to simulating the adaptability of clothes. We studied the dressed shapes of blouse with above-elbow sleeves and sleeveless according to five types of arm movement (basic posture, reach forward 45, 90, and reach lateral 45, 90) in the stand-posture. Experiments were conducted to understand the dressed shape through 3-D measurement Vivid 910 and to investigate the width, depth, area distribution and gap of the shape of blouses on the section map with a software program for 3-D shape analysis, Rapid Form 2004. The Data were analyzed by factor analysis. The results of this study are as follows: The ratio of depth per width in the stand-posture was lower than other arm movements and the reach lateral was higher than the reach forward. The gap of the upper body was a briefed 4 factor; front, front-side, back, and back-side. It was higher than the sleeveless with a change of the gap in the dressed blouse with above-elbow sleeves by arm movements per stand-posture. The divisional gap shows the adaptability of clothes according to the types of blouse and arm movements in the change of the ratio.

팔 동작에 따른 소매의 착의 면적 및 외관 길이 변화 (A Change in the Area and External Length of the Shape of Sleeve according to Arm Movements)

  • 이명희
    • 한국의류산업학회지
    • /
    • 제12권5호
    • /
    • pp.619-625
    • /
    • 2010
  • The purpose of this research is to analyze the shapes of blouse with above-elbow sleeves according to arm movements. The shapes include five types of the arm movement(basic posture, reach forward 45, 90, and reach lateral 45, 90) in the stand-posture, which were made by different adaptability of clothes. Experiments were conducted to figure out the dressed shape through 3-D measurement Vivid 910, and also to investigate the area of the shape of sleeves on the section map and the diagonal length of the block made by the basic section line in lateral part of sleeve with Rapid Form 2004, a software for 3-D shape analysis. The Data were analyzed by factor analysis, Anova, Duncan test, t-test. The results of this study were as follows: First, the area of sleeve was briefed 3 factor; front, center, back in sleeve. Second, there were different effect of arm movement, section level and part of shapes in the area of sleeve. Third, the diagonal length was briefed 4 factor; back, back-center, front-center, front. Forth, after t-test, there were statistically significant between the reach forward and lateral and between the angles of arm reach.

Characteristics of Static Balance in Patients With Adolescent Idiopathic Scoliosis

  • Shin, Seung-Sub;Woo, Young-Keun
    • 한국전문물리치료학회지
    • /
    • 제13권4호
    • /
    • pp.47-55
    • /
    • 2006
  • The purpose of this study was to compare the static balance of standing position between adolescent idiopathic scoliosis (AIS) and a normal group that were aged-matched. There were forty subjects included in this study. Twenty-seven healthy subjects (age, $13.9{\pm}1.2$ yrs; height, $161.9{\pm}7.5$ cm; weight, $52.2{\pm}7.7$ kg) and thirteen AIS subjects (age, $14.2{\pm}2.2$ yrs; height, $161.5{\pm}8.7$ cm; weight, $48.1{\pm}8.1$ kg) were participated in the study. The thirteen subjects in the AIS group had a major Cobb angle between $20.1^{\circ}$ and $49^{\circ}$. Each group was tested with the Balance Performance Monitor (BPM). The parameters for static balance were sway area, sway path, max velocity, mean balance, anterior-posterior angle, and left-right angle of each group with their eyes opened and again with their eyes closed. Both sides of the forward reach test and the lateral reach test were also performed on each group. Results from the BPM tested showed significantly increases in all parameters of static balance with those patients with AIS under the conditions where eyes were opened and closed. In the right and left forward reach test, there was no significant difference between normal and AIS groups. However, in the lateral reach test with right and left direction, there were significant differences between normal and AIS groups. For the normal subjects, there were significant differences in the parameters with sway path and anterior-posterior sway angle between the eyes opened and closed. However, there were no significant differences in the all parameters between eyes opened and closed for the AIS subjects. These results suggest that, balance programs could be used in the rehabilitation setting for intervention of AIS and evaluation of AIS. Further study is needed to measure many patients with AIS and other functional balance scales for clinical application.

  • PDF

기구학적 전이를 이용한 케이싱 오실레이터의 순기구학 해석 (The Forward Kinematics Solution for Casing Oscillator Using the Kinematic Inversion)

  • 배형섭;백재호;박명관
    • 한국정밀공학회지
    • /
    • 제21권11호
    • /
    • pp.130-139
    • /
    • 2004
  • The Casing Oscillator is a bore file Equipment for the all-casing process. All-casing process is a method of foundation work in construction yard to oscillate steel Casing in the ground. The existing Casing Oscillator has some problem like not boring horizontally with disturbance and not driving Casing othor angle except horizon. To solve problem, the new structure Casing Oscillator is presented and studied. The performance of Casing Oscillator is improved by kinematics analysis. The Casing Oscillator is similar to the parallel manipulator in structure. So we obtain Inverse kinematics solution of Casing Oscillator easily. But it is difficult to solve forward kinematics of Casing Oscillator. T his paper presents a novel pose description corresponding to the structure characteristics of parallel manipulators. Through analysis on geometry theory, we obtain a new method of the closed-form solution to the forward kinematics using Kinematic Inversion. The closed-form solution contains two different meanings -analytical and real-time. So we reach the goal of practical application and control. Closed-form forward kinematics solution is verified by an inverse kinematics analysis. It shows that the method has a practical value for real -time control and inverse kinematics servo control.

Assessment Methodology of Junction Temperature of Light-Emitting Diodes (LEDs)

  • Chang, Moon-Hwan;Pecht, Michael
    • 마이크로전자및패키징학회지
    • /
    • 제23권3호
    • /
    • pp.7-14
    • /
    • 2016
  • High junction temperature directly or indirectly affects the optical performance and reliability of high power LEDs in many ways. This paper is focused on junction temperature characterization of LEDs. High power LEDs (3W) were tested in temperature steps to reach a thermal equilibrium condition between the chamber and the LEDs. The LEDs were generated by pulsed currents with duty ratios (0.091% and 0.061%) in multiple steps from 0mA and 700mA. The diode forward voltages corresponding to the short pulsed currents were monitored to correlate junction temperatures with the forward voltage responses for calibration measurement. In junction temperature measurement, forward voltage responses at different current levels were used to estimate junction temperatures. Finally junction temperatures in multiple steps of currents were estimated in effectively controlled conditions for designing the reliability of LEDs.

팔 동작에 따른 소매유무별 블라우스 착의형상의 3차원적 파악 (A Study on the Dressed Shapes of the Blouse with Short Sleeves and Sleeveless according to Arm Movement Using 3-D Scanner)

  • 이명희
    • 한국의류산업학회지
    • /
    • 제8권2호
    • /
    • pp.209-213
    • /
    • 2006
  • The 3-D information is useful as basic data which has been utilized in the development of simulating technology as fit-simulation. The experiment is designed to take some useful data on the variant shapes which contribute in simulating the adaptability of the clothes. The general figure of the clothes are made after the figure of the basic standing posture of the human body. The shape of the clothes fits with kinetic characteristic of the human body as the form of the clothes gets twisted, the ease of the clothes changes, and the clothes itself expands. We studied the dressed shapes of blouse according to two types of the arm movement(basic posture and reach forward) and three types of clothes(foundation, blouse with short sleeves and sleeveless) in the sit-down-posture. We accomplished some experimental data on three-dimensional measurement of the dressing shapes using TDS-3100 3-D scanner made in Japan PULSTECH. It is considered that the variant of shapes and distribution of gaps in the dressed shapes of blouse are determined by the adaptability of clothes made in arm movement.

A Study on The Effects of Aerobic and Foam Roller Exercise Programs on Body Balance in Senior Women

  • An, Seong Ja;Kwon, Hae Yeon
    • 국제물리치료학회지
    • /
    • 제8권2호
    • /
    • pp.1182-1189
    • /
    • 2017
  • The purpose of this study was conducted with senior women of ages 65 in Community Center to identify effective exercise methods for preventing falling accidents by enhancing balancing skills through aerobic and foam roller exercise programs. There were 24 subjects : 11 aerobics group and 13 foam roller group. 30 minute exercise programs were conducted against both groups 12 times 6 weeks. Various tests, including Time up and go test, Forward reach test, One-leg standing with eyes open/closed and Y-Balance were conducted prior to commencing the exercise program. Wilcoxon's Signed-ranks test was executed to analyze the changes in balance of the aerobic and foam roller exercise group prior to and after the experiment, and Mann-Whitney test was executed to compare the difference between the two groups. The Y-Balance(post. medial) show statistically significant differences in the amount of change before and after exercise between the two groups, except for Timed up and go test, Forward reach test, Y-Balance(ant.), and Y-Balance(post. lateral), which did not showed statistically significant difference (p<0.05). Foam roller exercises are effective methods to enhance the balancing skills in senior women to prevent falling accidents.

수동형 UHF RFID 인터페이스에 대한 Link budget의 재해석 및 전파 환경 요소 분석 (Passive UHF RFID Propagation Characteristics and Reconsideration of Link budget on Practical Communication Area)

  • 정진우;박경태;노형환;박준석;김형석
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2008년도 정보통신설비 학술대회
    • /
    • pp.469-472
    • /
    • 2008
  • In this paper, we discuss the recent trends on the passive UHF RFID tag chip design techniques and several important system parameters. We also summarize link budget studies on both conventional and modem UHF RFID communications. The paper highlights the reverse link limited case, which has known to be the minor concern if reader continuous wave (CW) can reach the tag in sufficient level. This makes sense when the tag sensitivity is rather high (over 10-12${\mu}W$); however, since the tag chip fabrication technologies have been developed by time, the tag chip threshold levels are now less-dominant in determining link margin. If the tag limitation can be alleviated, the forward link limited case can be resolved; thus, we rather focus on the path-loss problem. Since the path-losses are still exist in both forward and reverse links, and it can be doubled while CW travels the reader-tag-reader path because forward link and reverse link are on the same distance. Consider if reader receiver sensitivity is very high in the worst case. In this case, weaken tag response (i.e., backscatters) cannot reach the level that reader receiver can process tag data; bit-error rate can be higher. Overall, backscatter levels should be high enough so that reader receiver can correctly function. After discussing link budget, we carried out practical measurements on fading effects between two circularly polarized UHF RFID antennas in a small scale area.

  • PDF