• 제목/요약/키워드: re-circulated water

검색결과 11건 처리시간 0.025초

하나로 2차 냉각펌프의 고진동 해소방안 (The Solution of Severe Vibration Problen of the Secondary Cooling Pump in HANARO)

  • 박용철
    • 한국유체기계학회 논문집
    • /
    • 제5권4호
    • /
    • pp.26-31
    • /
    • 2002
  • The heat produced by the fission in the fuel of HANARO, 30 MW of research reactor, was transferred from the primary cooling water to the secondary cooling water through heat exchangers. The secondary cooling water absorbing the heat was circulated by secondary cooling pumps and cooled through 33 MW of cooling tower. Each capacity of the three secondary cooling pumps was fifty percent ($50\%$) of full load. The two pumps were normally operated and the other pump was standby. One of the secondary cooling pumps has often made troubles by high vibration. To release these troubles the pump shaft has been re-aligned, the pump bearing has been replaced with new one, the shaft sleeve has been replaced with new one, the shaft and the impeller have been re-balanced representatively and/or the vibration of motor has been tested by disconnecting the shaft of pump. But the high vibration of pump cannot be cleared. We find out the weight balance trouble of the assembly in which the impeller is installed in the shaft. After clearing the trouble, the high vibration is relieved and the pump is operated smoothly. In this paper, the trouble solution shooting method of secondary cooling pump is described including the reason of high vibration

하나로 2차 냉각펌프의 고진동 해소방안 (The Solution of High Vibration of the Secondary Cooling Pump in HANARO)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.197-202
    • /
    • 2001
  • The heat produced by the fission in the fuel of HANARO, 30 MW of research reactor, was transferred from the primary cooling water to the secondary cooling water through heat exchangers. The secondary cooling water absorbed the heat was circulated by secondary cooling pumps and cooled through 33 MW of cooling tower. Each capacity of the three secondary cooling pumps was fifty percent ($50\%$) of full load. The two pumps were normally operated and the other pump was standby. One of the secondary cooling pumps has often get troubles by high vibration. To release these troubles the pump shaft has been re-aligned, the pump bearing has been replaced with new one, the shaft sleeve has been replaced with new one, the shaft and the impeller have been re-weight balanced representatively or the vibration of motor has been tested by disconnecting the shaft of pump. But the high vibration of pump cannot be cleared. We find out the weight balance trouble of the assembly that the impeller is installed in the shaft. After clearing the trouble, the high vibration is released and the pump is operated with smooth. In this paper the trouble solution of secondary cooling pump is described including the reason of high vibration.

  • PDF

마산만 유역의 지하수 유출량 추정 (Estimation of the Groundwater Discharges in Masan Bay Watershed)

  • 양정석;조홍연;정신택;김상준
    • 한국해안해양공학회지
    • /
    • 제16권4
    • /
    • pp.213-223
    • /
    • 2004
  • 마산만 연안유역의 지하수 유출량을 Darcy 방법을 이용하여 추정하였다. 지하수위, 관정의 위치, 투수계수, 대수층 두께, 해안선 길이 정보를 이용하여 추정한 지하수 유출량은 강우량 대비 1.65%정도이다. 마산만 유역의 암반층을 통한 지하수 유출량은 $0.7\times10^4$ $m^2/year$정도로 추정되었으며, 충적층을 통한 지하수 유출량은 $1.0\times10^7$$m^3/year$정도로 추정되어 암반층을 통한 유출량은 무시할 만한 정도로 파악되었다. 한편, 한국해양연구원(2003)에서 방사성 동위원소를 이용하여 추정한 지하수 유출량은 본 연구에서 추정한 지하수 유출량의 20배 정도에 해당하지만, 이는 연안 대수층으로 침입한 재순환 해수의 영향으로 파악되었으며, 해안선에 근접한 관측정의 운영을 통하여 지하수위 및 염도 변화를 지속적으로 관측하여 재순환해수의 정량적인 영향분석을 보다 상세하게 연구할 필요가 있는 것으로 판단된다.

우물관정형(SCW공법) 지열히트펌프 시스템의 설치 및 운영사례 (A Case Study on the Installation and Operation of the Standing Column Well Method)

  • 나상민;박시삼;박종헌;이건중;김태원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.592-595
    • /
    • 2009
  • In recent years, geothermal heat pump (GHP) systems have become increasingly popular for heating and cooling in buildings. The Standing Column Well (SCW) method is one of the most efficient GHP system. Because it use groundwater for heat transfer material. In SCW systems, water is re-circulated between the well and the building (heat pump). It is only a short time since this method has been applied in domestic. So we have to refer to the developed countries' guides and manuals of SCW. In this paper, several design and construction points of SCW method are filed. We used real operation data of SCW system at Chong-Ju Univ. site for economical efficiency analysis. As a result, the payback period of Chong-Ju Univ. site is calculated at 7.23 years.

  • PDF

순환여과시스템을 이용한 바지락 Ruditapes philippinarum (Adams & Reeve, 1850) 의 번식 생리에 관한 연구: I. 가온에 의한 성 성숙 유도 (Conditioning of Manila clam Ruditapes philippinarum (Adams & Reeve, 1850) using recirculation system: I. Induction of the gametogenesis using water temperature elevation)

  • 이희중;박경일;최광식
    • 한국패류학회지
    • /
    • 제30권2호
    • /
    • pp.127-134
    • /
    • 2014
  • Gonad maturation of Manila clam, Ruditapes philippinarum was induced in this study using a recirculation system over 8 weeks in early spring. Clams used in the experiment were collected in $15^{th}$ April 2010 from the west coast of Korea, as the surface water temperature remained $11^{\circ}C$. To induce gametogenesis and subsequent maturation seawater temperature was elevated $1^{\circ}C$ per day over 10 days to reach $20^{\circ}C$. For the experiment, clams were raised in 120 L quadrangle tank maintained with re-circulated seawater system over 57 days. Water quality parameters including the water temperature, salinity dissolved oxygen, ammonium ion and nitrate levels in the tanks were monitored daily. Mixture of concentrated microalgae including Tetraselmis, Isochrysis, Pavlova and Thalassiosira weissflogii was supplied to clams twice a day, and quantity of the daily ration was adjusted as 3% of clam body dry weight. Histology was applied to examine gonad maturation. Daily monitoring of the water quality parameters indicated that the recirculation system supplied suitable environment to Manila clam; the nitrogenous components stayed below toxic levels (< 0.2 mg/L). At the beginning of the study, clams were mostly in early developing stage. As the seawater temperature reached $20^{\circ}C$, 10 days after the experiment, 20% of clams reached late development at 12 days. First ripe clams were observed at 42 days and 40% of clams were in ripe and ready for spawning at the end of study, 57 days after the experiment. In this study, gametogenesis of Manila clam was successfully induced by elevating water temperature and supplying commercially produced microalgae in a recirculation tank system.

DEPENDENCY OF SINGLE-PHASE FAC OF CARBON AND LOW-ALLOY STEELS FOR NPP SYSTEM PIPING ON PH, ORIFICE DISTANCE AND MATERIAL

  • Moon, Jeong-Ho;Chung, Hung-Ho;Sung, Ki-Woung;Kim, Uh-Chul;Rho, Jae-Seong
    • Nuclear Engineering and Technology
    • /
    • 제37권4호
    • /
    • pp.375-384
    • /
    • 2005
  • To investigate the flow-accelerated corrosion (FAC) dependency of carbon steel (A106 Gr. B) and low-alloy steels (1Cr-1/2Mo, 21/4Cr-1Mo) on pH, orifice distance, and material, experiments were carried out. These experiments were performed using a flow velocity of 4 m/sec (partly 9 m/sec) at pH $8.0\~10.0$ in an oxygen-free aqueous solution re-circulated in an Erosion-Corrosion Test Loop at $130^{\circ}\;{\ldots}$ for 500 hours. The weight loss of the carbon steel specimens appeared to be positively dependent on the flow velocity. That of the carbon and low-alloy steel specimens also showed to be distinguishably dependent on the pH. At pH levels of $8.0\~9.5$ it decreased, but increased from 9.5 to 10.0. Utility water chemistry personnel should carefully consider this kind of pH dependency to control the water system pH to mitigate FAC of the piping system material. The weight loss of the specimens located further from the orifice in the distance range of $6.8\~27.2$ mm was shown to be greater, except for 21/4Cr-1Mo, which showed no orifice distance dependency. Low alloy steel specimens exhibited a factor of two times better resistance to FAC than that of the carbon steel. Based on this kind of FAC dependency of the carbon and low-alloy steels on the orifice distance and material, we conclude that it is necessary to alternate the composition of the secondary piping system material of NPPs, using low-alloy steels, such as 21/4Cr-1Mo, particularly when the system piping has to be replaced.

자외선을 이용한 활어용 수조수의 위생 대책 수립 (Sanitary Control of Aquarium Tank Water with U.V. Light)

  • 최승태;박미연;장동석
    • 한국수산과학회지
    • /
    • 제28권4호
    • /
    • pp.428-434
    • /
    • 1995
  • 생선 횟집의 활어용 수조수에 대한 위생 대책 수립의 일환으로 자외선을 이용한 제균 효과를 검토하였다. 1. 물 두께 10mm (유수량: 730ml/sec, 등; 5조, 통과 시간: 2.4초)와 자외선 조사량 75W의 조건에서 자외선 등 통과 직후의 해수에서의 생균수 감소율은 평균 $85.0\%$였다. 2. 장염 비브리오균의 경우, 자외선 조사 후 1시간만에 3 log cycle 감소하였으며, 그 이후 큰 변화가 없었다. 3. 한편 쥐치에 같은 조건으로 72시간 처리했을 때 내장 세균의 감소는 거의 없었으나, 돌돔 및 쥐치의 표피와 아가미에서의 생균수 감소율은 약 2log cycle이었다. 4. 패류의 여수율을 좋게 하기 위하여 수조수의 온도를 $20-23^{\circ}C$로 조절한 수조에서 홍합과 굴을 같은 조건으로 처리했을 때 24시간 후에 생균수의 감소율은 홍합과 굴에서 각각 2 log cycle 정도였으며, 분변계 대장균의 경우는 각각 3 log cycle, 1.5 log cycle 정도 감소하였다.

  • PDF

부곡 지열수의 심부환경과 지화학적 진화: 유황형 지열수의 생성과정 재해석 (Geochemical Evolution and Deep Environment of the Geothermal Waters in the Bugok Area: Reconsideration on the Origin of Sulfate-type Geothermal Water)

  • 고용권;윤성택;김천수;배대석;박성숙
    • 자원환경지질
    • /
    • 제34권4호
    • /
    • pp.329-343
    • /
    • 2001
  • 국내에서 가장 높은 용출온도를 보이는 경남 부곡 지열수에 대하여 Yun et al.(1998)에 의하여 기존에 발표된 수리화학 및 동위원소 자료를 토대로 지열수의 심부환경과 지화학적 진화과정을 재해석하였다. 부곡 지열수는 지화학적 특성에 따라 3가지 유형으로 구분되어 진다(지열수I,II,III형). 지열수I형과II형은 높은 온도(55.2~$77.2^{\circ}C$)를 보이며, 화학적으로 Na-$SO_4$형에 속하지만, pH와 Eh가 다소 차이가 나며, $SO_4$함량이 크다는 것이 특징이다. 지열수 중심지역으로부터 외곽부에서 산출되는 지열수 III형은 29.3~$47.0^{\circ}C$의 용출온도를 보이며, Na-$HCO_3SO_4$형을 나타낸다. 지열수 I형에 대하여 다성분계 지질온도계의 적용결과는 심부저장지의 온도가 115~$130^{\circ}C$인 것으로 추정되었다. 다양한 지화학적 특성을 보여주는 부곡 지열수의 지화학적 진화과정은 다음과 같이 해석될 수 있다. 첫째, 부곡지역보다 높은 지형에서 함양된 지하수가 심부로 순환하게 되면서, 퇴적암 또는 심부의 화강암과 물-암석 반응이 진행된다. 이때 퇴적층에 함유되어 있던 황산염 광물의 용해반응으로 지하수는 다량의 $SO_4$를 함유하게 된다. 둘째, 지하수가 계속 심부로 순환하는 과정에서 환원환경에 접하게 되어 $H_2$S가 생성되고, 심부열원에 의하여 약 13$0^{\circ}C$까지 가열되어 규산 염광물과의 반응정도가 높아진다. 이 때 pH는 상승하고 SO$_4$함량은 감소하게 되며, 방해석이 침전조건에 놓이게 됨으로써, 결국 지열수는 Na-SO$_4$형을 띠게 된다. 셋째, 이렇게 형성된 지열수가 유동로를 따라 상승하는 과정에서 덜 깊게 순환하는 지하수와 혼합과정을 거치게 된다. 지열수와 혼합되는 지하수는 퇴적층내 황철석의 산화반응에 의해 다량의 SO$_4$를 함유한 것으로 사료된다. 이렇게 형성된 지열수는 계속 상승하면서 천부환경의 지하수와 혼합되어 부곡지역내 다양한 지화학 특성을 보이는 지열수를 형성하게 된다.

  • PDF

고려인삼엽차의 제조방법에 따른 사포닌 성분의 함량 및 조성 (Effect of Processing Methods on the Saponin Contents of Panax ginseng Leaf-Tea)

  • 장현기
    • 한국식품영양학회지
    • /
    • 제16권1호
    • /
    • pp.46-53
    • /
    • 2003
  • 건강 기능성과 기호성, 간편성을 갖는 건강차를 개발하기 위하여 4년생 인삼엽을 7월과 8월에 각각 채엽하고 이를 재료로 하여 건조법(DRT), 숙성법(AGT), 열처리법(HPT) 등의 3가지 방법으로 인삼엽차를 제조하고 인삼제품의 품질 지표인 조사포닌 함량과 조성을 조사한 결과는 다음과 같다. 1. 인삼엽차의 조사포닌 함량은 제조 방법 중 HPT 가 18.72~18.82%로 가장 높았으며 AGT는 18.24~18.29%, DRT는 17.02~17.17%순이었고 채엽시기별 함량 차이는 거의 나타나지 않았다. 2. 인삼엽차의 ginsenoside 조성은 채엽시기, 제조방법별로 유사하였으며, ginsenoside-Re가 1.97~2.15로 가장 높았고, -Rd이 1.48~l 79, -Rg$_1$이 1.33~l.58, 그리고 -Rb, -Rb$_2$, -Rc 순이었다. 3. 인삼엽차의 protopanaxadiol(PD), protopanaxatriol(PT)계 사포닌의 함량비(PD/PT)는 제조 방법 중 DRT가 1.11~l.13, HPT 1.09~l.12이었고 AGT는 0.92~1.02로 다소 낮은 결과를 나타내었다. 또한 채엽시기별 함량비는 유사하였다. 4. 인삼엽차의 5분간 열탕침출액의 조사포닌 함량은 7월엽 제품, HPT가 각각 15.88%, 16.88%로 가장 높았고 ginsenoside함량은 -Re, -Rd, -Rg$_1$, -Rb$_2$, -Rc 순이었다. 알콜로 8시간 환류 추출한 총 사포닌과 5분간 열탕 침출액 중 조사포닌 함량을 비교한 조사포닌 침출율은 81.74~84.38%로서 7월엽 제품, HPT가 84.38%로 가장 높았고 ginsenoside침출율은 다소 낮은 78.00~88.13%를 나타내었다. 또한 30분간 침출액의 침출율은 88.01~92.31%로 5분간 침출율보다 7월엽 제품은 10~13%, 8월엽 제품은 약 20% 증가하였고 ginsenoside 침출율은 유사한 경향을 나타내었다.

트래드밀에서의 최대하 부하 운동과 간헐적 부위별 인체 냉각 시 심부와 말초 부위의 체온 변화 (Thermal Dynamics of Core and Periphery Temperature during Treadmill Sub-maximal Exercise and Intermittent Regional Body Cooling)

  • 이주영;;김정현
    • 한국생활환경학회지
    • /
    • 제16권2호
    • /
    • pp.89-100
    • /
    • 2009
  • 본 연구는 최대하 부하 트래드밀 운동과 간헐적 부위별 인체 냉각 시 심부와 말초 부위의 동적 체온조절을 관찰하기 위해 고안되었다. 이를 위해 총 다섯명의 남자 피험자가 세 가지 실험 조건, 머리와 손 냉각 조건(HH cooling), 다리 냉각 조건(Leg Cooling), 냉각하지 않는 대조군(Control)에 참여하였고, 모든 실험은 기온 24±1℃와 습도 50±5%RH로 유지되는 인공기후실에서 수행되었다. 피험자들은80%HRmax의 트래드밀 운동과 이어지는 회복 스케쥴을 두 번 반복하였고, 인체 부위별 냉각은 15℃의 물이 순환하는 액체 냉각모자, 장갑, 다리를 덮는 형태의 담요를 이용하여 회복 시에만 적용되었다. 본 연구 결과, (1) 직장온도(Tre)는 세 조건 간에 유의한 차이를 보이지 않았다; (2) 피부온도는 부위별로 특징되어지는 다양한 체온조절 현상을 보였다. 특히, 운동의 시작 시점에서 보이는 피부온도의 초기 하강은 주로 가슴, 넓적다리, 종아리, 손가락 피부 온도에서 관찰되었으며, 이 중 손가락 온도(Tfing)에서의 초기 하강 현상은 매우 현저했다. (3) 피부 온도가 초기 하강을 보이는 동안 Tre는 점점 증가했다. (4) 두 번째 운동 시작 시 Tfing에서의 초기 하강 규모는 Control 조건에서 평균 4.8℃, HH cooling 조건에서는 5.1℃, Leg cooling 조건에서는 3.4℃로, 통계적으로 유의한 차이를 보였다(p<0.05). 초기 하강 현상을 보인 시간은 Control 조건에서 평균 8.1분으로 HH cooling 조건에서는 7.9분, Leg cooling 조건에서는 6.3분보다 길었으나 통계적 차이는 발견되지 않았다. 결론적으로, 트래드밀 운동의 개시기에 관찰된 피부온도 하강 현상은 인체 심부의 온열 상태의 진행과는 반대되므로, 비 온열적 요인을 반영한다. 특히, Tfing에서 초기 하강의 규모는 인체 부위별 냉각에 의해 영향을 받았다. 따라서, 말초 부위의 피부온도 하강 현상은 운동 중 피부면의 온열 상태 예측 시 주의깊게 고려되어져야 한다.