• Title/Summary/Keyword: ray height

Search Result 438, Processing Time 0.024 seconds

A Computer Simulation for Small Animal Iodine-125 SPECT Development (소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션)

  • Jung, Jin-Ho;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jeong, Myung-Hwan;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.74-84
    • /
    • 2004
  • Purpose: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). Materials and Methods: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. Nal(T1) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Peformances of I-125 SPECT equipped with the optimal collimator were also estimated. Results: in the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, Nal(T1) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2:5:square and 0.5:10:hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR:GP:PH were 1.2:1.7:0.8 mm. The sensitivities of HR:GP:PH were 39.7:71.9:5.5 cps/MBq. Conclusion: The optimal crystal and collimator parameters for I-125 Imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.

Some Factors Affecting Bone Mineral Status of Postmenopausal Women (폐경 후 여성의 골격상태에 영향을 미치는 요인분석)

  • 오세인;이행신;이미숙;김초일;권인순;박상철
    • Korean Journal of Community Nutrition
    • /
    • v.7 no.1
    • /
    • pp.121-129
    • /
    • 2002
  • Osteoporosis, the typical metabolic bone disease of the elderly, is characterized by a reduction in bone mineral density (BMD) and increased fracture risk. Genetic and environmental factors are known to play a key role in bone metabolism, and diet is also considered to be one of the important factors. The purpose of the present study was to investigate the relationship among the factors affecting BMD, including stature, body weight, age, time period since onset of menopause, and biochemical markers of bone turnover in postmenopausal women. Seventy-eight postmenopausal women who visited health promotion center for health examinations volunteered to participate in this study and they were divided into two groups according to the time period since onset of menopause : women with a time period since onset of menopause of less than 5 years (Group 1) and women with a time period since onset of menopause of 5 years or more (Group 2). The demographic characteristics and dietary intake were surveyed using a questionnaire. BMDs of the lumbar spine and femoral neck of subjects were measured by dual energy X-ray absorptiometry. Serum levels of 25-hydroxy-vitamin D and parathyroid hormone (PTH), known to be indicators of bone related hormone status, were anlyzed. Serum samples were measured for calcium, phosphorus, alkaline phosphatase, and osteocalcin as bone formation indicators, and urine was analysed for deoxypyridinoline, creatinine, calcium, and sodium as bone resorption indicators. The results are as follow : The mean BMDs of the lumbar spin and femoral neck were $1.02 \pm 0.02 g/cm^2 and 0.81 \pm 0.02 g/cm^2 respectively, and the BMD level of Group 2 was significantly lower than tat of Group 1 (p<0.01, p<0.05, respectively). The mean daily intake of energy was 1838 $\pm$ 55 kcal. When nutrient intake was compared with the recommended dietary allowances (RDA) of the subjects, only calcium, vitamin A and riboflavin intake showed means lower than the RDA. The nutrient intake did not show any significant differences between Group 1 and 2 Serum and urine levels of biochemical markers of bone turnover did not show any significant differences between Group 1 and 2, and all were within the normal range. However, the PTH and deoxypyridinoline levels showed a tendency to be higher, and the osteocalcin level to be lower in Group 2 than in Group 1. Although age and years after menopause (YAM) showed negative correlations with lumbar spine bone mineral density (LBMD) (r= -0.38, p<0.001, and r= -0.26, p< 0.05, respectively), no correlation was found with femoral neck bone mineral density (NBMD). While height, body weight and body mass index (BMI) showed a positive correlation with LBMD (r= 0.32, p<0.001, r= 0.38, p<0.001, r= 0.22, p= 0.05, respectively), only body weight and BMI showed a positive correlation with NBMD (r= 0.30, p<0.01, and r= 0.27, p<0.05, respectivley). There was no significant corealtion between BMDs and the nutrient intake of subjects, except in the case of carbohydrates (r= 0.22, p<0.05). Also, serum and urine levels of bone turnover markers showed no significant correlation with nutrient intake. On the other hand, serum osteocalcin had a positive correlation with vitamin C intake (r= 0.22, p= 0.05), and urine deoxypyridinolin showed a negative correlation with niacin intake (r= -0.22, p= 0.05). Urinary na was negatively correlated with protein intake(r= -0.23, p= 0.05). The results suggested that it is difficult to prevent the decrease in bone mass among postmenopausal women eating the usual Korean diet. However, the BMDs of the lumbar spine and femoral neck were positively related to body weight ad BMI in postmenopausal women. Therefore, this study confirmed that one of the most effective ways to minimize bone loss in postmenopausal women would be to maintain an adequate body weight with balanced nutrient intake and activity in the pre-and postmenopausal periods.

A STUDY ON IN VIVO AND IN VITRO AMALGAM CORROSION (아말감의 구강내 부식 및 인공 부식에 관한 연구)

  • Lim, Byong-Mok;Kwon, Hyuk-Choon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.1-33
    • /
    • 1997
  • The objective of this study was to analyze the in vitro and in vivo corrosion products of low and high copper amalgams. The four different types of amalgam alloy used in this study were Fine cut, Caulk spherical, Dispersalloy, and Tytin. After each amalgam alloy and Hg were triturated according to the directions of the manufacturer by means of the mechanical amalgamator(Amalgam mixer. Shinhung Co. Korea), the triturated mass was inserted into a cylindrical metal mold which was 12mm in diameter and 10mm in height. The mass was condensed by 150Kg/cm compressive force. The specimen was removed from the mold and aged at room temperature for about seven days. The standard surface preparation was routinely carried out by emery paper polishing under running water. In vitro amalgam specimens were potentiostatically polarized ten times in a normal saline solution at $37^{\circ}C$(potentiostat : HA-301. Hukuto Denko Corp. Japan). Each specimen was subjected to anodic polarization scan within the potential range -1700mV to+400mV(SCE). After corrosion tests, anodic polarization curves and corrosion potentials were obtained. The amount of component elements dissolved from amalgams into solution was measured three times by ICP AES(Inductive Coupled Plasma Atomic Emission Spectrometry: Plasma 40. Perkim Elmer Co. U.S.A.). The four different types of amalgam were filled in occlusal and buccal class I cavities of four human 3rd molars. After about five years the restorations were carefully removed after tooth extraction to preserve the structural details including the deteriorated margins. The occlusal surface, amalgam-tooth interface and the fractured surface of in vivo amalgam corrosion products were analyzed. In vivo and in vitro amalgam specimens were examined and analyzed metallographically by SEM(Scanning Electron Microscope: JSM 840. Jeol Co. Japan) and EDAX(Energy Dispersive Micro X-ray Analyser: JSM 840. Jeol Co. Japan). 1. The following results are obtained from in vitro corrosion tests. 1) Corrosion potentials of all amalgams became more noble after ten times passing through the in vitro corrosion test compared to first time. 2) After times through the test, released Cu concentration in saline solution was almost equal but highest in Fine cut. Ag and Hg ion concentration was highest in Caulk spherical and Sn was highest in Dispersalloy. 3) Analyses of surface corrosion products in vitro reveal the following results. a)The corroded surface of Caulk spherical has Na-Sn-Cl containing clusters of $5{\mu}m$ needle-like crystals and oval shapes of Sn-Cl phase, polyhedral Sn oxide phase. b)In Fine cut, there appeared to be a large Sn containing phase, surrounded by many Cu-Sn phases of $1{\mu}m$ granular shapes. c)Dispersalloy was covered by a thick reticular layer which contained Zn-Cl phase. d)In Tytin, a very thin, corroded layer had formed with irregularly growing Sn-Cl phases that looked like a stack of plates. 2. The following results are obtained by an analysis of in vivo amalgam corrosion products. 1) Occlusal surfaces of all amalgams were covered by thick amorphous layers containing Ca-P elements which were abraded by occlusal force. 2) In tooth-amalgam interface, Ca-P containing products were examined in all amalgams but were most clearly seen in low copper amalgams. 3) Sn oxide appeared as a polyhedral shape in internal space in Caulk spherical and Fine cut. 4) Apical pyramidal shaped Sn oxide and curved plate-like Sn-Cl phases resulted in Dispersalloy. 5) In Tytin, Sn oxide and Sn hydroxide were not seen but polyhedral Ag-Hg phase crystal appeared in internal space which assumed a ${\beta}_l$ phase.

  • PDF

The development of conductive 10B thin film for neutron monitoring (중성자 모니터링을 위한 전도성 10B 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Jung, Yongju;Choi, Young-Hyun;Baek, Cheol-Ha;Moon, Myung-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.199-205
    • /
    • 2014
  • In the field of neutron detections, $^3He$ gas, the so-called "the gold standard," is the most widely used material for neutron detections because of its high efficiency in neutron capturing. However, from variable causes since early 2009, $^3He$ is being depleted, which has maintained an upward pressure on its cost. For this reason, the demands for $^3He$ replacements are rising sharply. Research into neutron converting materials, which has not been used well due to a neutron detection efficiency lower than the efficiency of $^3He$, although it can be chosen for use in a neutron detector, has been highlighted again. $^{10}B$, which is one of the $^3He$ replacements, such as $BF_3$, $^6Li$, $^{10}B$, $Gd_2O_2S$, is being researched by various detector development groups owing to a number of advantages such as easy gamma-ray discrimination, non-toxicity, low cost, etc. One of the possible techniques for the detection is an indirect neutron detection method measuring secondary radiation generated by interactions between neutrons and $^{10}B$. Because of the mean free path of alpha particle from interactions that are very short in a solid material, the thickness of $^{10}B$ should be thin. Therefore, to increase the neutron detection efficiency, it is important to make a $^{10}B$ thin film. In this study, we fabricated a $^{10}B$ thin film that is about 60 um in thickness for neutron detection using well-known technology for the manufacturing of a thin electrode for use in lithium ion batteries. In addition, by performing simple physical tests on the conductivity, dispersion, adhesion, and flexibility, we confirmed that the physical characteristics of the fabricated $^{10}B$ thin film are good. Using the fabricated $^{10}B$ thin film, we made a proportional counter for neutron monitoring and measured the neutron pulse height spectrum at a neutron facility at KAERI. Furthermore, we calculated using the Monte Carlo simulation the change of neutron detection efficiency according to the number of thin film layers. In conclusion, we suggest a fabrication method of a $^{10}B$ thin film using the technology used in making a thin electrode of lithium ion batteries and made the $^{10}B$ thin film for neutron detection using suggested method.

A Study on the Physique and Physical Fitness According to Skeletal Maturation of Obese Children (비만 아동의 골격성숙도에 따른 체격, 체력에 관한 연구)

  • Kim, Dae-Hoon;Yoon, Hyoung-ki;Oh, Sei-Yi;Lee, Young-Jun;Kim, Buem-Jun;Choi, Young-Min;Song, Dae-Sik;An, Ju-Ho;Seo, Dong-Nyeuck;Kim, Ju-Won;Na, Gyu-Min;Oh, Kyung-A
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.594-603
    • /
    • 2020
  • The aim of this study was to investigate the issue in obese children with a high probability of leading to precocious puberty for they have more advanced skeletal maturation compared to normal children in order to contribute to the health of obese children by identifying the relationship between physique and physical fitness according to their skeletal maturation. A total of 243 obese children between the ages of 10-13 were enrolled as subjects, and the skeletal maturation, which symbolize indicators of biological maturation, were evaluated by using the TW3 method after hand-wrist radiographs, thus classified the skeletal maturation level into retarded group(n=70), normal group(n=128), and advanced group(n=45). A stadiometer and InBody 270 (Biospace, Korea) were used to measure 3 components in physique. A total of 7 components in physical fitness, which included muscular strength, muscular endurance, flexibility, power, cardiovascular endurance, balance, agility, were measured as well. Descriptive statistics and one-way variable analysis (ANOVA) were conducted for data processing using SPSS 25.0, and Duncan's multiple-range method was used for post hoc analysis; and it was considered significant at the level of P< .05. Analysis results of this study may be summarized as follow. First, height and weight in physique factors according to the skeletal maturation between the retarded, normal, and advanced groups in males and females were highly significant. Second, physical fitness comparison according to the skeletal maturation in males were statistically significant in muscular strength, power, and agility whereas muscular strength and balance were statistically significant in females.

Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography (소아 흉부촬영 시 나이와 체격에 따른 입사피부선량)

  • Shin, Gwi-Soon;Min, Ki-Yeul;Kim, Doo-Han;Lee, Kwang-Jae;Park, Ji-Hwan;Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • Exposure during childhood results in higher risk for certain detrimental cancers than exposure during adulthood. We measured entrance skin dose (ESD) under 7-year children undergoing chest imaging and compared the relationship between ESD and age, height, weight, chest thickness. Though it is important to measure chest thickness for setting up the exposure condition of chest examination, it is difficult to measure chest thickness of children. We set up exposure parameters according to age because chest thickness of children has correlation with age. In the exposure parameters, for chest A-P examination under 2 year-children, tube voltage (kVp) in hospital A was higher than that in hospital B while tube current (mAs) was higher in hospital B, thus the ESD values were about 1.7 times higher in hospital B. However, for chest P-A examination over 4 year-children, the tube voltage was 7 kVp higher in hospital B, the tube current were same in all two systems, and focus to image receptor distance (FID) in hospital B (180 cm) was longer than that in hospital A (130 cm), thus the ESD values were 1.4 times higher in hospital A. For same ages, the ESD values for chest A-P examinations were higher than those for chest P-A examinations. Comparing ESD according to age, ESD values were $154{\mu}Gy$, $194{\mu}Gy$ and $138{\mu}Gy$ for children under 1 year, 1 to under 4 years and 4 to under 7 years of age, respectively. These values were lower than reference level ($200{\mu}Gy$) recommended in JART (japan association of radiological technologists), however these were higher than reference values recommended by EC (european commission), NRPB (national radiological protection board) and NIFDS (national institute of food & drug safety evaluation). In conclusion, the values of ESD were affected by exposure parameters from radiographer's past experience more than x-ray system. ESD values for older children were not always higher than those for younger children. Therefore we need to establish our own DRLs (diagnostic reference levels) according to age of the children in order to optimize pediatric patient protection.

Positron Annihilation Spectroscopy of Active Galactic Nuclei

  • Doikov, Dmytry N.;Yushchenko, Alexander V.;Jeong, Yeuncheol
    • Journal of Astronomy and Space Sciences
    • /
    • v.36 no.1
    • /
    • pp.21-33
    • /
    • 2019
  • This paper focuses on the interpretation of radiation fluxes from active galactic nuclei. The advantage of positron annihilation spectroscopy over other methods of spectral diagnostics of active galactic nuclei (therefore AGN) is demonstrated. A relationship between regular and random components in both bolometric and spectral composition of fluxes of quanta and particles generated in AGN is found. We consider their diffuse component separately and also detect radiative feedback after the passage of high-velocity cosmic rays and hard quanta through gas-and-dust aggregates surrounding massive black holes in AGN. The motion of relativistic positrons and electrons in such complex systems produces secondary radiation throughout the whole investigated region of active galactic nuclei in form of cylinder with radius R= 400-1000 pc and height H=200-400 pc, thus causing their visible luminescence across all spectral bands. We obtain radiation and electron energy distribution functions depending on the spatial distribution of the investigated bulk of matter in AGN. Radiation luminescence of the non-central part of AGN is a response to the effects of particles and quanta falling from its center created by atoms, molecules and dust of its diffuse component. The cross-sections for the single-photon annihilation of positrons of different energies with atoms in these active galactic nuclei are determined. For the first time we use the data on the change in chemical composition due to spallation reactions induced by high-energy particles. We establish or define more accurately how the energies of the incident positron, emitted ${\gamma}-quantum$ and recoiling nucleus correlate with the atomic number and weight of the target nucleus. For light elements, we provide detailed tables of all indicated parameters. A new criterion is proposed, based on the use of the ratio of the fluxes of ${\gamma}-quanta$ formed in one- and two-photon annihilation of positrons in a diffuse medium. It is concluded that, as is the case in young supernova remnants, the two-photon annihilation tends to occur in solid-state grains as a result of active loss of kinetic energy of positrons due to ionisation down to thermal energy of free electrons. The single-photon annihilation of positrons manifests itself in the gas component of active galactic nuclei. Such annihilation occurs as interaction between positrons and K-shell electrons; hence, it is suitable for identification of the chemical state of substances comprising the gas component of the investigated media. Specific physical media producing high fluxes of positrons are discussed; it allowed a significant reduction in the number of reaction channels generating positrons. We estimate the brightness distribution in the ${\gamma}-ray$ spectra of the gas-and-dust media through which positron fluxes travel with the energy range similar to that recorded by the Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics (PAMELA) research module. Based on the results of our calculations, we analyse the reasons for such a high power of positrons to penetrate through gas-and-dust aggregates. The energy loss of positrons by ionisation is compared to the production of secondary positrons by high-energy cosmic rays in order to determine the depth of their penetration into gas-and-dust aggregations clustered in active galactic nuclei. The relationship between the energy of ${\gamma}-quanta$ emitted upon the single-photon annihilation and the energy of incident electrons is established. The obtained cross sections for positron interactions with bound electrons of the diffuse component of the non-central, peripheral AGN regions allowed us to obtain new spectroscopic characteristics of the atoms involved in single-photon annihilation.

Characteristics of Blood Mixed Cement in Percutaneous Vertebroplasty (경피적 척추 성형술에서 혈액 혼합 시멘트의 특성)

  • Seo, Jin-Hyeok;Woo, Young-Ha;Jeong, Ju-Seon;Kim, Do-Hun;Kim, Ok-Gul;Lee, Sang-Wook;Park, Chan-Ho
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.435-439
    • /
    • 2019
  • Purpose: This study evaluated the efficacy of blood mixed cement for osteoporotic vertebral compression fractures in reducing the complications of percutaneous vertebroplasty using conventional cement. Materials and Methods: This study was performed retrospectively in 80 patients, from January 2016 to January 2017. Porous cement was formed by mixing 2, 4, and 6 ml of blood with 20 g of cement used previously. A tube with a diameter and length of 2.8 mm and 215 mm, respectively, was used and the polymerization temperature, setting time, and optimal passing-time were measured and compared with those using only conventional cement. Radiologically, the results were evaluated and compared. Results: The polymerization temperature was 70.3℃, 55.3℃, 52.7℃, and 45.5℃ in the conventional cement (R), 2 ml (B2), 4 ml (B4), and 6 ml (B6), respectively, and the corresponding setting time decreased from 960 seconds (R) to 558 seconds (B2), 533 seconds (B4), and 500 seconds (B6). The optimal passing-time was 45 seconds (B2), 60 seconds (B4), and 78 seconds (B6) at 73 seconds (R), respectively and as the amount of blood increased, it was similar to the cement passing-time. The radiological results showed that the height restoration rates and the vertebral subsidence rates similar among the groups. Two cases of adjacent vertebral compression fractures in the R group and one in the B2 and B4 groups were encountered, and the leakage rate of the cement was approximately two times higher than that in the conventional cement group. Conclusion: In conventional percutaneous vertebroplasty, the procedure of using autologous blood with cement decreased the polymerization temperature, reduced the setting time, and the incidence of cement leakage was low. These properties may contribute to more favorable mechanical properties that can reduce the complications compared to conventional cements alone.