• 제목/요약/키워드: rate of resistance increase

검색결과 690건 처리시간 0.03초

구충성빈혈(鉤蟲性貧血)에 관(關)한 연구(硏究) (The Study on the Ferrokinetics and Acquired Immunity in Repeated Hookworm Infections)

  • 이문호;이필웅
    • 대한핵의학회지
    • /
    • 제1권2호
    • /
    • pp.61-74
    • /
    • 1967
  • In order to confirm whether acquired immunity or resistance can be developed by the repeated hookworm infections, the 150 mature actively moving filariform ancylostoma duodenale larvae obtained from the severe hookworm anemia patients were orally given to 8 healthy volunteers in three divided doses, 50 in each, at 5 day interval. Also the hematological changes as well as several ferrokinetics using $^{59}Fe$ were done and were compared with 10 controls. The clinical symptoms and signs were checked every day for the first 3 weeks and then twice weekly until the end of the experiment. The appearance of the ova in the stool was examined by the formalin ether method and the ova was counted by the Stoll's method. The following laboratory tests were done: 1) Red blood cell count, venous blood hematocrit(micromethod), hemoglobin count (cyanomethemoglobin method) were checked every 5 to 7 day interval. 2) Plasma iron concentration (Barkan's modified method) was determined every 2 to 3 week interval. 3) Radioisotope studies: a) Ferrokinetics: Huff et al and Bothwell's method were applied. Erythropoietic Index (% of normal)=$\frac{Subject's\;turnover/100ml\;whole\;blood{\times}100}{Average\;normal\;turnover/100ml\;whole\;blood}$ of the gastrointestinal absorption of iron: Radioiron($^{59}Fe$) balance b) Quantitative measurement method was applied. c) Determination of the plasma erythropoietin activity: Fried's method was applied. Following were the results: 1) The serum iron level was lower. The red cell volume was decreased, but with relative increase of plasma volume. 2) The plasma iron disappearance time was accelerated and the plasma iron turnover rate was decreased. The red cell iron turnover rate was markedly increased, while all of the red cell iron concentration, circulating red cell iron. plasma iron pool were decreased. The daily iron pool turnover and red cell renewal rate were increased. 3) The erythropoietic index, erythropoietin activity and intestinal absorption of iron($^{59}Fe$) were markedly increased. 4) The infectivity was $9.8{\pm}1.31%$ which was lower than that observed in the single infection. 5) From these observations, it is concluded that the hookworm anemia is essentially iron deficieny in its origin and some immunity acquisition is possible with repeated infections.

  • PDF

비균일계 마이크로채널에서의 유량 변화 특성 (Variation of Flow Rates in Heterogeneous Microchannel Systems)

  • 김진용;이효송;유재근;김기호;이영우
    • 공업화학
    • /
    • 제17권1호
    • /
    • pp.28-32
    • /
    • 2006
  • 본 연구에서는 polydimethylsiloxane (PDMS)와 glass로 이루어진 마이크로채널의 너비와 깊이 및 외부전압에 따른 특성을 알아보기 위하여 각각의 마이크로채널에서의 유량 변화를 조사하였다. PDMS와 SU-8 감광제를 사용하는 soft lithographic method 기술을 사용하여 마이크로채널을 만들었다. 채널의 깊이 $50{\mu}m$$100{\mu}m$에 대하여, 채널의 너비를 $100{\mu}m$, $200{\mu}m$, $300{\mu}m$로 하여 제작하였으며, 각각의 마이크로채널에 0.3 kV, 0.35 kV, 0.4 kV 그리고 0.45 kV의 외부전압을 걸어 유량 변화를 측정하였다. 실험 결과, 동일한 너비를 갖는 마이크로채널에서는 외부전압이 증가함에 따라 유량이 증가하였다. 이는 외부전압이 증가함에 따라 전기장이 증가하기 때문이다. 동일한 외부전압에서 마이크로채널의 너비가 증가할수록 유량이 증가하는 경향이 나타났고, 이는 채널 너비의 증가가 내부의 저항을 감소시키는 효과를 가져온 것으로 사료된다. 또한, 동일하게 단면적을 두 배로 증가시켜 깊이와 너비의 영향을 조사한 결과, 저 전압에서는 깊이의 영향이 크게 나타났으며 고 전압에서는 너비의 영향이 크게 나타났다.

에폭시 기지 입자 강화 GFRP를 사용한 계단형 패치 보수법이 고온 고습 환경하에서 재료의 물성 회복에 미치는 영향 (Effect to Material Strength Recovery of Stepped Patch Repair with Epoxy based Particle Reinforced GFRP Composites under Hygrothermal Environment)

  • 정경석;박수정;김윤해
    • Composites Research
    • /
    • 제31권3호
    • /
    • pp.88-93
    • /
    • 2018
  • 본 연구에서는 입자크기가 서로 다른 할로이사이트 나노튜브(Halloysite nanotube, HNT)와 밀드 카본(Milled carbon, MC) 강화 복합재료를 사용하여 손상된 복합재료 적층판을 계단형 패치 보수법에 따라 수리하고, 손상된 면과 수리면 사이의 접합 계면에 입자가 미치는 기계적, 구조적 영향을 분석하였다. 이 때, 고온고습의 가혹한 수분 환경에 장시간 노출시켜 손상된 판을 형성하는 기존 재료와의 상대적인 재료 물성 회복률을 비교하였으며 기계적 물성 시험을 통해 성능평가를 실시하였다. 그 결과 $70^{\circ}C$ 고온 증류수에서 HNT는 입자 첨가량에 따라 흡습률이 MC에 비해 뚜렷한 차이를 보였으며 인장강도와 굽힘강도의 경우, 대체적으로 HNT로 강화된 복합재를 사용하여 보수한 시험편이 흡습 전과 후 모두 높은 수치를 나타냈다. 특히, 0.5, 1 wt. %의 HNT가 첨가되었을 때 흡습률이 가장 적었고 이는 기계적 강도 증가에 관여하는 하나의 요인으로 작용하였다. 반면 MC는 소량만으로도 높은 흡습 저항성을 나타냈으며 하중의 방향에 따라 강도의 차이가 발생했다.

운동훈련(運動訓練)에 대(對)한 심폐기능(心肺機能)의 적응(適應)에 관(關)한 연구(硏究) (Cardio-pulmonary Adaptation to Physical Training)

  • 조강하
    • The Korean Journal of Physiology
    • /
    • 제1권1호
    • /
    • pp.103-120
    • /
    • 1967
  • As pointed out by many previous investigators, the cardio-pulmonary system of well trained athletes is so adapted that they can perform a given physical exercise more efficiently as compared to non-trained persons. However, the time course of the development of these cardio-pulmonary adaptations has not been extensively studied in the past. Although the development of these training effects is undoubtedly related to the magnitude of an exercise load which is repeatedly given, it would be practical if one could maintain a good physical fitness with a minimal daily exercise. Hence, the present investigation was undertaken to study the time course of the development of cardio-pulmonary adaptations while a group of non-athletes was subjected to a daily 6 to 10 minutes running exercise for a period of 4 weeks. Six healthy male medical students (22 to 24 years old) were randomly selected as experimental subjects, and were equally divided into two groups (A and B). Both groups were subjected to the same daily running exercise (approximately 1,000 kg-m). 6 days a week for 4 weeks, but the rate of exercise was such that the group A ran on treadmill with 8.6% grade for 10 min daily at a speed of 127 m/min while the group B ran for 6 min at a speed of 200 m/min. In order to assess the effects of these physical trainings on the cardio-pulmonary system, the minute volume, the $O_2$ consumption, the $CO_2$ output and the heart rate were determined weekly while the subject was engaged in a given running exercise on treadmill (8.6% grade and 127 m/min) for a period of 5 min. In addition, the arterial blood pressure, the cardiac output, the acid-base state of arterial blood and the gas composition of arterial blood were also determined every other week in 4 subjects (2 from each group) while they were engaged in exercise on a bicycle ergometer at a rate of approximately 900 kg m/min until exhaustion. The maximal work capacity was also determined by asking the subject to engage in exercise on treadmill and ergometer until exhaustion. For the measurement of minute volume, the expired gas was collected in a Douglas bag. The $O_2$ consumption and the $CO_2$ output were subsequently computed by analysing the expired gas with a Scholander micro gas analyzer. The heart rate was calculated from the R-R interval of ECG tracings recorded by an Offner RS Dynograph. A 19 gauge Cournand needle was inserted into a brachial artery, through which arterial blood samples were taken. A Statham $P_{23}AA$ pressure transducer and a PR-7 Research Recorder were used for recording instantaneous arterial pressure. The cardiac output was measured by indicator (Cardiogreen) dilution method. The results may be summarized as follows: (1) The maximal running time on treadmill increased linearly during the 4 week training period at the end of which it increased by 2.8 to 4.6 times. In general, an increase in the maximal running time was greater when the speed was fixed at a level at which the subject was trained. The mammal exercise time on bicycle ergometer also increased linearly during the training period. (2) In carrying out a given running exercise on treadmill (8.6%grade, 127 m/min), the following changes in cardio·pulmonary functions were observed during the training period: (a) The minute volume as well as the $O_2$ consumption during steady state exercise tended to decrease progressively and showed significant reductions after 3 weeks of training. (b) The $CO_2$ production during steady state exercise showed a significant reduction within 1 week of training. (c) The heart rate during steady state exercise tended to decrease progressively and showed a significant reduction after 2 weeks of training. The reduction of heart rate following a given exercise tended to become faster by training and showed a significant change after 3 weeks. Although the resting heart rate also tended to decrease by training, no significant change was observed. (3) In rallying out a given exercise (900 kg-m/min) on a bicycle ergometer, the following change in cardio-vascular functions were observed during the training period: (3) The systolic blood pressure during steady state exercise was not affected while the diastolic blood Pressure was significantly lowered after 4 weeks of training. The resting diastolic pressure was also significantly lowered by the end of 4 weeks. (b) The cardiac output and the stroke volume during steady state exercise increased maximally within 2 weeks of training. However, the resting cardiac output was not altered while the resting stroke volume tended to increase somewhat by training. (c) The total peripheral resistance during steady state exercise was greatly lowered within 2 weeks of training. The mean circulation time during exorcise was also considerably shortened while the left heart work output during exercise increased significantly within 2 weeks. However, these functions_at rest were not altered by training. (d) Although both pH, $P_{co2}\;and\;(HCO_3-)$ of arterial plasma decreased during exercise, the magnitude of reductions became less by training. On the other hand, the $O_2$ content of arterial blood decreased during exercise before training while it tended to increase slightly after training. There was no significant alteration in these values at rest. These results indicate that cardio-pulmonary adaptations to physical training can be acquired by subjecting non-athletes to brief daily exercise routine for certain period of time. Although the time of appearance of various adaptive phenomena is not identical, it may be stated that one has to engage in daily exercise routine for at least 2 weeks for the development of significant adaptive changes.

  • PDF

Elevated temperature resistance of concrete columns with axial loading

  • Alaskar, Abdulaziz;Alyousef, Rayed;Alabduljabbar, Hisham;Alrshoudi, Fahed;Mohamed, Abdeliazim Mustafa;Jermsittiparsert, Kittisak;Ho, Lanh Si
    • Advances in concrete construction
    • /
    • 제9권4호
    • /
    • pp.355-365
    • /
    • 2020
  • The influence of temperature on the material of concrete filled columns (CFCs) under axial loading has been quantitatively studied in this research. CFCs have many various advantages and disadvantages. One of the important inefficiency of classic CFCs design is the practical lack of hooped compression under the operational loads because of the fewer variables of Poisson's rate of concrete compared to steel. This is the reason why the holder tends to break away from the concrete core in elastic stage. It is also suggested to produce concrete filled steel tube columns with an initial compressed concrete core to surpass their design. Elevated temperatures have essentially reduced the strengths of steel tubes and the final capacity of CFCs exposed to fire. Thus, the computation of bearing capacity of concrete filled steel tube columns is studied here. Sometimes, the structures of concrete could be exposed to the high temperatures during altered times, accordingly, outcomes have shown a decrement in compressive-strength, then an increase with the reduction of this content. In addition, the moisture content at the minimal strength is declined with temperature rising. According to Finite Element (FE), the column performance assessment is carried out according to the axial load carrying capacities and the improvement of ductility and strength because of limitations. Self-stress could significantly develop the ultimate stiffness and capacity of concrete columns. In addition, the design equations for the ultimate capacity of concrete columns have been offered and the predictions satisfactorily agree with the numerical results. The proposed based model (FE model of PEC column) 65% aligns with the concrete exposed to high temperature. Therefore, computed solutions have represented a better perception of structural and thermal responses of CFC in fire.

외과계 입원환자에 대한 Vancomycin의 약물사용 평가 (Drug Use Evaluation of Vancomycin in Hospitalized Patients of Surgery Departments)

  • 이영미;최경업
    • 한국임상약학회지
    • /
    • 제9권1호
    • /
    • pp.35-43
    • /
    • 1999
  • Over the last 50 years, a number of antibiotic agents have been developed and clinically used in the area of infectious diseases. Due to antimicrobial resistance problems and increasing health care costs, the rational use of antibiotics has been required. As a drug of choice to treat infections caused by MRSA, vancomycin has been extensively prescribed since the late 1970's. Recently, reports of vancomycin-resistant organisms such as VRE and VRSA have been increased to draw medical concerns. The objectives of this study were to evaluate the rational use of vancomycin and the appropriateness of the Restrictional Program of Antibiotic Utilization (RPAU) which has been operated at Samsung Medical Center. A retrospective chart review was performed in 132 hospitalized patients treated with vancomycin in the surgery departments from. January to June 1998. The guidelines of ASHP and HICPAC for vancomycin were modified and used as our criteria to determine the vancomycin DUE. In one hundred out of the patients, uses of vancomycin were approved by the Department of Infectious Diseases (DID) based on the RPAU. Vancomycin was appropriately used in $62.5\%$ of the 100 patients according to the criteria of justification of use, while $60.0\%,\;60.0\%,\;79.0\%,\;and\;51.0\%$ of the patients showed appropriate according to those of lab reports such as applicable culture obtained, pretreatment SCr, WBC and serum drug concentration monitoring, respectively. Although the rest 32 patients were not approved to receive vancomycin by the DID, twenty two percent continued receiving vancomycin treatment. This might result from the fact that the RPAU was started not before the use of antibiotics but in the middle of antimicrobial therapy. Continual education should be provide to the related health professionals and the RPAU should be simultaneously modified in order to increase the rate of appropriate uses of antibiotics.

  • PDF

Inosiplex에 의한 세포성 면역반응의 변화 (Modulation of Cellular Immune Response by Inosiplex)

  • 이헌구;이정호;김학군;하대유
    • 대한미생물학회지
    • /
    • 제21권2호
    • /
    • pp.251-259
    • /
    • 1986
  • This study was performed to assess the effect of inosiplex(ISP) on the resistance of mice Candida albicans infection, the migration of chicken leukocytes, the production of leukocyte migration inhibitory factor(LIF), and the cell-mediated immunity(CMI) to lepomin in multibacillary lepromatous leprosy patients. The treatment with ISP before or on the time of infection with C. albicans had no or deliterious effect, and treatment with ISP after infection had no effect on the recovery of C. albicans from the kidneys of mice. The migratory ability of chicken leukocytes and the production of LIF from splenocytes of mice were not affected by ISP treatment. However, ISP decreased the migration of chicken leukocytes in vitro, and this decrease was dose-dependent. The therapy of lepromatous leprosy patients with ISP for 10 or 30 days clearly showed the increase of the significant positive rate of Mitsuda skin test to lepromin. The immune recovery as a result of the therapy was found to be the best in the group of patients treated for 30 days. This results suggest that (1) the effect of ISP in renal candidiasis can vary depending on the time of treatment relative to infection, (2) ISP can primarily change the migratory ability of chicken leukocytes but does not affect the production of LIF in mice, and (3) the classical therapy combined with ISP can reinforce or restore the defences of lepromatous leprosy patients against Mycobacterium leprae.

  • PDF

황산 용액에서 Al6061 합금의 아노다이징 피막 형성거동 (Formation Behavior of Anodic Oxide Films on Al 6061 Alloy in Sulfuric Acid Solution)

  • 문성모;정기훈;임수근
    • 한국표면공학회지
    • /
    • 제51권6호
    • /
    • pp.393-399
    • /
    • 2018
  • Formation behavior of aluminum anodic oxide (AAO) films on Al6061 alloy was studied in view of thickness, morphology and defects in the anodic films in 20 vol.% sulfuric acid solution at a constant current density of $40mA/cm^2$, using voltage-time curve, observation of anodized specimen colors and surface and cross-sectional morphologies of anodic films with anodization time. With increasing anodizing time, voltage for film formation increased exponentially after about 12 min and its increasing rate decreased after 25 min, followed by a rapid decrease of the voltage after about 28 min. Surface color of anodized specimen became darker with increasing anodizing time up to about 20 min, while it appeared to be brighter with increasing anodizing time after 20 min. The darkened and brightened surfaces with anodizing time are attributed to an increase in thickness of porous anodic oxide film and a chemical damage of the films due to heat generated by increased resistance of the film, respectively. Cross-sectional observation of AAO films revealed the formation of defects of crack shape at the metal/oxide interface after 15 min which prevents the growth of AAO films. Width and length of the crack-like defect increased with anodizing time up to 25 min of anodizing, and finally the outer part of AAO films was partly dissolved or detached after 30 min of anodizing, resulting in non-uniform surface structures of the AAO films.

The Sulfidation and Oxidation Behavior of Sputter-Deposited Nb-Al-Cr Alloys at High Temperatures

  • Habazaki, Hiroki;Yokoyama, Kazuki;Konno, Hidetaka
    • Corrosion Science and Technology
    • /
    • 제2권3호
    • /
    • pp.141-147
    • /
    • 2003
  • Sputter-deposited Nb-Al-Cr alloys. $3-5{\mu}m$ thick, have been prepared on quartz substrates as oxidation-and sulfidation-resistant materials at high temperatures. The oxidation or the alloys in the $Ar-O_2$ atmosphere of an oxygen partial pressure of 20 kPa follows approximately the parabolic rate law, thus being diffusion controlled. Their oxidation rates are almost the same as or even lower than those ofthc typical chromia-forming alloys. The multi-lavered oxide scales are formed on the ternary alloys. The outermost layer is composed of $Cr_2O_3$, which is"mainly responsible for the high oxidation'resistance of these alloys. In contrast to sputter-deposited Cr-Nb binary alloys reported previously, the inner layer is not porous. TEM observation as well as EDX analysis indicates that the innermost layer is a mixture of $Al_2O_3$ and niobium oxide. The dispersion of $Al_2O_3$ in niobium oxide may be attributable to the prevention of the formation of the porous oxide layer. The sulfidation rates of the present ternary alloys arc higher than those of the sputter-deposited Nb-AI binary alloys, but still several orders of magnitude lower than those of conventional high temperature alloys. Two-layered sulfide scales are formed, consisting of an outer $Al_2S_3$ layer containing chromium and an inner layer composed of $NbS_2$ and a small amount of $Cr_2S_3$. The presence of $Cr_2S_3$ in the inner protective $NbS_2$ layer may be attributed to the increase in the sulfidation rates.

스테인리스강 STS 316L과 탄소강 A516-70의 이종금속 GTA 용접부 특성에 대한 연구 (A Study of Characteristics on the Dissimilar Metals (STS 316L - Carbon Steel: ASTM A516-70) Welds made with GTAW)

  • 김세철;신태우;문인준;장복수;고진현
    • Journal of Welding and Joining
    • /
    • 제33권4호
    • /
    • pp.37-43
    • /
    • 2015
  • Characteristics of dissimilar metal welds between STS 316L and carbon steel ASTM A516 Gr.70 made with GTAW have been evaluated in terms of microstructure, ferrite content, chemical analysis, hardness and corrosion resistance. Three heat inputs of 9.00, 11.25, 13.00kJ/cm were employed to make joints of dissimilar metals with ER309 wire. Based on microstructural examination, the amount of vermicular type of ${\delta}$-ferrite was increased with increasing heat input due to the increase of Creq/Nieq in the second layer of welds. Based on the EDX analysis of weld metals, Cr and Ni content in the 2nd layer increased while those content in the first layer of welds decreased with heat inputs. Cellular solidification mode in the 1st layer and dendritic solidification mode in the 2nd layer due to different cooling rates were prevailed, respectively. Heat affected zone which formed hard microstructure showed higher hardness than the weld metal. The salt spray test of dissimilar metals weld joints showed that the carbon steel surfaces only corroded. The weight loss rate due to corrosion increased up to 100hours but it decreased above 100 hours. There was little difference in the weight loss caused by corrosion regardless of heat inputs.