Measurement of Crack Length by Ultrasonic Attenuation Coefficient (초음파 감쇠계수에 의한 균열길이의 측정)

  • Chung, Nam-Yong;Park, Sung-Il
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.340-345
    • /
    • 2003
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the relation between crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the results of experiments, the measurement method of crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF

Measurement of Interfacial Crack Length by Ultrasonic Attenuation Coefficients on Adhesively Bonded Components (접착부재의 초음파 감쇠계수에 의한 계면균열 길이의 측정)

  • 정남용;박성일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.130-137
    • /
    • 2004
  • The ultrasonic attenuation coefficients were measured by interfacial crack length in the adhesive components of double-cantilever beam(DCB). The energy release rate, G, was obtained by the experimental measurement of compliance. The numerical analysis by the boundary element method(BEM) and Ripling's equation was investigated. The experimental results represent that the relation between interfacial crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. A measurement method of the interfacial crack length by the ultrasonic attenuation coefficient was proposed and discussed.

Measurement of Crack Length by Ultrasonic Attenuation Coefficient (초음파 감쇠계수에 의한 균열길이의 측정)

  • Chung, Nam-Yong;Park, Sung-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.4
    • /
    • pp.386-393
    • /
    • 2004
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the crack length for the ultrasonic attenuation coefficient and energy release rate is increases proportionally From the experimental results, we proposed a detecting method of the crack length by the ultrasonic attenuation coefficient and discussed it.

A Study on Energy Release Rate for Interface Cracks in Anisotropic Dissimilar Materials (이방성 이종재 접합계면 균열의 에너지 해방률에 관한 연구)

  • Kim, Jin-Gwang;Jo, Sang-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1835-1843
    • /
    • 2001
  • The energy release rate for an interface crack in anisotropic dissimilar materials was obtained by the eigenfunction expansion method and also was analyzed numerically by the reciprocal work contour integral method. It was shown that the results for orthotropic dissimilar materials are consistent with the other worker's results.

Combustive Properties of Ethylene-Propylene Die Monomer/Polypropylene/Clay Nanocomposites (에틸렌-프로필렌 디엔 단량체/폴리프로필렌/클레이 나노복합체의 연소성)

  • Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.190-195
    • /
    • 2011
  • Effects of ethylene-propylene diene monomer (EPDM)/polypropylene (PP), zinc oxide, stearic acid, and clay on the combustive properties based on EPDM/PP were investigated. The EPDM/PP/clay nanocomposites was compounded to prepare specimen for combustive analysis by cone calorimeter (ISO 5660-1). It was found that the combustive properties in the nanocomposites decreased due to the fire resistance compared with unfilld EDPM/PP. The nanocomposites showed the lower peak heat release rate (PHRR) than that of virgin EPDM/PP, while stearic acid for softening ruber increased the mean heat release rate (MHRR) by itself, combustible.

In Vitro Release of Angiotensin and ${\alpha}-Amylase$ from Polyethylene Glycol-Grafted Polyurethane Devices (폴리에칠렌글리콜이 그라프트된 폴리우레탄 디바이스로부터 안지오텐신 및 ${\alpha}$-아밀라제의 방출)

  • Ha, Chung-Hun;Kim, Sung-Ho
    • Journal of Pharmaceutical Investigation
    • /
    • v.19 no.4
    • /
    • pp.185-190
    • /
    • 1989
  • The release of angiotensin and ${\alpha}-amylase$ from monolithic devices of different molecular weight of polyethylene glycol (PEC) grafted polyurethane copolymer was investigated. Water-soluble PEG grafted polymer provided a controlled release of angiotensin and ${\alpha}-amylase$. The release rate of angiotensin and ${\alpha}-amylase$ could be controlled by varying the molecular weight of PEC grafted. The release mechanism may be associated with the creation of pore or domain through the devices following the gel swelling and self-aggregation by PEC grafted polymer. Hydrophobic polyurethane grafted with PEG can provide a biomaterial for prolonged release of angiotensin and ${\alpha}-amylase$ from angiotensin and ${\alpha}-amylase$ blended system.

  • PDF

Preparation and Dissolution Characteristics of the Compression-Coated Controlled Release Tablet Exhibiting Three-step Release (압축코팅법에 의한 3단계 약물방출형 지속성제제의 제조 및 용출특성)

  • Kim, Cheol-Soo;Kwon, Hyeok-Lo;Cha, Bong-Jin;Kwon, Jong-Won;Yang, Joong-Ik;Min, Shin-Hong
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.2
    • /
    • pp.133-137
    • /
    • 1992
  • A novel oral controlled release tablet which may offer more uniform drug level in the body than simple zero-order was developed. The tablet is composed of three layers; outer film layer, middle part compression-coated hydroxypropylmethylcellulose (HPMC) matrix layer, and inner core layer. Each layer contains nicardipine HCl as a model drug. In vitro dissolution test showed that the tablet released the drug in clear three steps; a rapid initial release, followed by a constant rate of release, and then a second phase of fast release of drug. The dissolution characteristics could be modified easily by changing the grade of HPMC, thickness of matrix layer, content of methylcellulose in matrix layer, content of active ingredient in each layer. The pH of dissolution medium did not affect the release profile. This three-step release system is expected to raise the blood concentration rapidly to effective level and to maintain effective blood level longer than simple slow-release systems.

  • PDF

Simulating Daily Inflow and Release Rates for Irrigation Reservoirs(II) -Modeling Reservoir Release Rates- (관개용 저수지의 일별 유입량과 방류량의 모의 발생(II) -저수지 통관 방류량의 추정-)

  • 김현영;박승우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.2
    • /
    • pp.95-104
    • /
    • 1988
  • This study refers to the development of a hydrologic model simulating daily inflow and release rates for inigation reservoirs. A daily - based model is needed for adequate operation of an irrigation reservoir sufficing the water demand for paddy fields which is closely related to meteorological conditions. And the objective of this study is to develop a reservoir release rate model and then to calibrata the parameters. The release rates model considers daily water demands , water supply for transplanting, minmum release for maintaining canal flow, and maxirnun and regular flooding depth for determining effective rainfall on paddy fields. Each of the factors in the model was regarded as a lumped pararuter representing the average condition of a whole irrigated area. The water demand was estimated form the potential evapotranspiration by Penman method, the effective rainfall, and the infiltration on paddy fields. The release model was found to be capable of adequately simulating daily reservoir releases based on meteorological data.

  • PDF

THE EFFECTS OF SOMATOSTATIN INFUSION ON THE PLASMA PROFILE OF GROWTH HORMONE, INSULIN AND CORTISOL IN SHEEP

  • Rose, M.T.;Obara, Y.;Fuse, H.;Hodate, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.9 no.1
    • /
    • pp.57-61
    • /
    • 1996
  • Four castrated Corriedale sheep were used in an experiment to observe the changes in insulin, growth hormone and cortisol in blood plasma following a prolonged infusion of a high rate of somatostatin (SRIF). The animals wee infused with either saline, 25 or $50{\mu}g/kg/h$ of SRIF for 3 hours. Blood samples wee taken every 20 minutes until 1 hour following the end of the SRIF infusion. Both SRIF infusion levels suppressed the release of insulin into plasma to approximately 3.5 mU/l. The SRIF infusions reduced the concentration of growth hormone to barely detectable levels. Following the withdrawal of SRIF there was a massive release of growth hormone. The plasma concentration of growth hormone reached 60 ng/ml within 20 minutes, the length of the growth hormone discharge was in excess of 1 hour. The extent of the discharge of growth hormone following the SRIF infusions was greater than that suppressed by the infusion. The SRIF apparently caused an increase in the plasma concentration of cortisol at the end of the infusion and following is withdrawal. This is possibly associated with some change in the metabolic rate associated with the suppression of insulin or glucagons release. The present experiment demonstrates that a high rate of SRIF infusion can not completely inhibit the release of insulin into the plasma.

Crack Propagation in a Piezoelectric Layer Bonded between Two Orthotropic Layers (직교 이방성 탄성체에 접합된 압전 재료의 균열 전파 거동)

  • Kim, Chuel-Gon;Kwon, Soon-Man;Lee, Kang-Yang
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.22-26
    • /
    • 2001
  • In this paper, we examine the steady state dynamic electromechanical behavior of an eccentric Yoffe crack in a piezoelectric ceramic layer bonded between two orthotropic elastic layers under the combined anti-plane mechanical shear and in-plane electrical loadings. We adopted permeable crack face condition. Numerical values on the dynamic energy release rate are obtained. The initial crack propagation orientation for PZT-5H piezoceramic is also predicted by maximum energy release rate criterion.

  • PDF