• Title/Summary/Keyword: rate measurement bias

Search Result 62, Processing Time 0.026 seconds

Analysis of Spatial Variability for Infiltration Rate of Field Soils II. Kriging (토양중(土壤中) 물의 침투속도(浸透速度)의 공간변이성(空間變異性) 분석(分析) II. Kriging)

  • Park, Chang-Seo;Kim, Jai-Joung;Cho, Seong-Jin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.17 no.1
    • /
    • pp.18-23
    • /
    • 1984
  • Spatial variability of 96 laboratory-measured infiltration rates on the Hwadong SiCL was studied using geostatistical concepts. The measurement was made at the nodes of the regular grid consisting of 12 rows and 8 columns. Sample spacing within rows and columns was 3 and 2m, respectively. Kriging was a means of spacial prediction that can be used for the infiltration rate. It was optimal in the sense that it provided estimates at unrecorded places without bias and with minimum and known variance. An attempt has been made with original data to verily the validity of all assumptions (Stationarity, Variogram models, etc.) by Jack-knifing procedure and frequency distribution. Variogram models were not different from other models, such as linear in calculation of both kriged values and variances in justification of its choice for simplicity. Correlation coefficient for a one-to-one relationship between measured and kriged values was found to be 0.308, which was not significantly different at 1% significance level.

  • PDF

Clinical Effect of Acupuncture Combined with Herbal Medicine in Treatment of PSD: A Systematic Review and Meta-Analysis (뇌졸중 후 우울증에 대한 침과 한약의 결합 치료 효과: 체계적 문헌 고찰 및 메타분석 연구)

  • Sakong, Jong-Won;Lim, Su-Yeon;Kim, Sang-Ho;Chung, Dae-kyoo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.31 no.3
    • /
    • pp.169-186
    • /
    • 2020
  • Objectives: The purpose of this study was to provide clinical evidence to support the use of acupuncture combined herbal medicine for post-stroke depression. Methods: Studies were identified by searching Pubmed, EMBASE, Cochrane Library, NDSL, RISS, KMbase, KISS, and CNKI. Randomized controlled trials that verified effects of the acupuncture combined with the herbal medicine for PSD were included in this study. Literature searches of English, Chinese, and Korean databases were performed. Two authors independently extracted the data and assembled the study quality. Results: Of 698 RCTs screened, 17 RCTs were selected. Most of the studies had unclear risk of bias. Among the 17 RCTs, 10 were meta-analyzed. As for the outcome measurement, the effective rate and the HAMD were most commonly used. The meta-analysis of the studies revealed that the PSD cure effective rate in the acupuncture combined with herbal medicine group was higher than that in the Western medicine group (RR: 1.23, 95% CI: 1.14 to 1.33, p<0.00001, I2=0%). Also, the HAMD in the acupuncture combined with herbal medicine group was significantly different compared to the Western medicine group (MD -5.54, 95% CI -9.80 to -1.29, p=0.01, I2=99%). The quality of the selected RCTs was low. Conclusions: Acupuncture combined with herbal medicine is effective for treating post-stroke depression. However, It is worth noting that the included studies were of relatively poor quality. The sample sizes were also small. Based on the findings of this study, further investigations into the diagnosis and treatment of PSD are warranted.

Validation of Sea Surface Temperature (SST) from Satellite Passive Microwave Sensor (GPM/GMI) and Causes of SST Errors in the Northwest Pacific

  • Kim, Hee-Young;Park, Kyung-Ae;Chung, Sung-Rae;Baek, Seon-Kyun;Lee, Byung-Il;Shin, In-Chul;Chung, Chu-Yong;Kim, Jae-Gwan;Jung, Won-Chan
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.1
    • /
    • pp.1-15
    • /
    • 2018
  • Passive microwave sea surface temperatures (SST) were validated in the Northwest Pacific using a total of 102,294 collocated matchup data between Global Precipitation Measurement (GPM) / GPM Microwave Sensor(GMI) data and oceanic in-situ temperature measurements from March 2014 to December 2016. A root-mean-square (RMS) error and a bias error of the GMI SST measurements were evaluated to $0.93^{\circ}C$ and $0.05^{\circ}C$, respectively. The SST differences between GMI and in-situ measurements were caused by various factors such as wind speed, columnar atmospheric water vapor, land contamination near coastline or islands. The GMI SSTs were found to be higher than the in-situ temperature measurements at low wind speed (<6 m/s) during the daytime. As the wind speed increased at night, SST errors showed positive bias. In addition, other factors, coming from atmospheric water vapor, sensitivity degradation at a low temperature range, and land contamination, also contributed to the errors. One of remarkable characteristics of the errors was their latitudinal dependence with large errors at high latitudes above $30^{\circ}N$. Seasonal characteristics revealed that the errors were most frequently observed in winter with a significant positive deviation. This implies that SST errors tend to be large under conditions of high wind speeds and low SSTs. Understanding of microwave SST errors in this study is anticipated to compensate less temporal capability of Infrared SSTs and to contribute to increase a satellite observation rate with time, especially in SST composite process.

Nucleation and growth mechanism of nitride films deposited on glass by unbalanced magnetron sputtering

  • Jung, Min J.;Nam, Kyung H.;Han, Jeon G.
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.06a
    • /
    • pp.14-14
    • /
    • 2001
  • Nitride films such as TiN, CrN etc. deposited on glass by PVD processes have been developed for many industrial applications. These nitride films deposited on glass were widely used for not only decorative and optical coatings but also wear and corrosion resistance coatings employed as dies and molds made of glass for the example of lens forming molds. However, the major problem of nitride coatings on glass by PVD process is non-uniform film owing to pin-hole and micro crack. It is estimated that nonuniform coating is influenced by a different surface energy between metal nitrides and glass due to binding states. In this work, therefore, for the evaluation of nucleation and growth mechanism of nitride films on glass TiN and CrN film were synthesized on glass with various nitrogen partial pressure by unbalanced magnetron sputtering. Prior to deposition, for the examination of relationship between surface energy and film microstructure plasma pre-treatment process was carried out with various argon to hydrogen flow rate and substrate bias voltage, duty cycle and frequency by using pulsed DC power supply. Surface energy owing to the different plasma pre-treatment was calculated by the measurement of wetting angle and surface conditions of glass were investigated by X-ray Photoelectron Spectroscopy(XPS) and Atomic Force Microscope(AFM). The microstructure change of nitride films on glass with increase of film thickness were analyzed by X-Ray Diffraction(XRD) and Scanning Electron Microscopy(SEM).

  • PDF

Rear Surface Passivation with Al2O3 Layer by Reactive Magnetron Sputtering for High-Efficiency Silicon Solar Cell

  • Moon, Sun-Woo;Kim, Eun-Kyeom;Park, Won-Woong;Jeon, Jun-Hong;Choi, Jin-Young;Kim, Dong-Hwan;Han, Seung-Hee
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.211-211
    • /
    • 2012
  • The electrical loss of the photo-generated carriers is dominated by the recombination at the metal- semiconductor interface. In order to enhance the performance of the solar cells, many studies have been performed on the surface treatment with passivation layer like SiN, SiO2, Al2O3, and a-Si:H. In this work, Al2O3 thin films were investigated to reduce recombination at surface. The Al2O3 thin films have two advantages, such as good passivation properties and back surface field (BSF) effect at rear surface. It is usually deposited by atomic layer deposition (ALD) technique. However, ALD process is a very expensive process and it has rather low deposition rate. In this study, the ICP-assisted reactive magnetron sputtering method was used to deposit Al2O3 thin films. For optimization of the properties of the Al2O3 thin film, various fabrication conditions were controlled, such as ICP RF power, substrate bias voltage and deposition temperature, and argon to oxygen ratio. Chemical states and atomic concentration ratio were analyzed by x-ray photoelectron spectroscopy (XPS). In order to investigate the electrical properties, Al/(Al2O3 or SiO2,/Al2O3)/Si (MIS) devices were fabricated and characterized using the C-V measurement technique (HP 4284A). The detailed characteristics of the Al2O3 passivation thin films manufactured by ICP-assisted reactive magnetron sputtering technique will be shown and discussed.

  • PDF

DEVELOPMENT OF PRECISION ATTITUDE DETERMINATION SYSTEM FOR KOMPSAT-2

  • Yoon Jae-Cheol;Shin Dongseok;Lee Hungu;Lee Young-Ran;Lee Hyunjae;Bang Hyo-Choong;Cheon Yee-Jin;Shin Jae-Min;Moon Hong-Youl;Lee Sang-Ryool;Jeun Gab-Ho
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.296-299
    • /
    • 2004
  • KARI precision attitude determination system has been developed for high accurate geo-coding of KOMPSAT-2 image. Sensor data from two star trackers and a IRU are used as measurement and dynamic data. Sensor data from star tracker are composed of QUEST and unit vector filter. Filter algorithms consists of extended Kalman filter, unscented Kalman filter, and least square batch filter. The type of sensor data and filter algorithm can be chosen by user options. Estimated parameters are Euler angle from 12000 frame to optical bench frame, gyro drift rate bias, gyro scale factor, misalignment angle of star tracker coordinate frame with respect to optical bench frame, and misalignment angle of gyro coordinate frame with respect to optical bench frame. In particular, ground control point data can be applied for estimating misalignment angle of star tracker coordinate frame. Through the simulation, KPADS is able to satisfy the KOMPSAT-2 mission requirement in which geo-location accuracy of image is 80 m (CE90) without ground control point.

  • PDF

Hydrophobic and Mechanical Characteristics of Hydrogenated Amorphous Carbon Films Synthesized by Linear Ar/CH4 Microwave Plasma

  • Han, Moon-Ki;Kim, Taehwan;Cha, Ju-Hong;Kim, Dong-Hyun;Lee, Hae June;Lee, Ho-Jun
    • Applied Science and Convergence Technology
    • /
    • v.26 no.2
    • /
    • pp.34-41
    • /
    • 2017
  • A 2.45 GHz microwave plasma with linear antenna has been prepared for hydrophobic and wear-resistible surface coating of carbon steel. Wear-resistible properties are required for the surface protection of cutting tools and achieved by depositing a hydrogenated amorphous carbon film on steel surface through linear microwave plasma source that has $TE_{10}-TEM$ waveguide. Compared to the existing RF plasma source driven by 13.56 MHz, linear microwave plasma source can easily generate high density plasma and provide faster deposition rate and wider process windows. In this study, $Ar/CH_4$ gas mixtures are used for hydrogenated amorphous carbon film deposition. When microwave power of 1000 W is applied, 40 cm long uniform $Ar/CH_4$ plasma could be obtained in gas pressure of 200~400 mTorr. The Vickers hardness measurement of hydrogenated amorphous carbon film on steel surface was evaluated. It was found the optimized deposition condition at $Ar:CH_4=25:25$ sccm, 300 mTorr with microwave power of 1000W and RF bias power of 100W. By deposition of hydrogenated amorphous carbon film, contact angle on steel surfaces increases from $43.9^{\circ}$ to $93.2^{\circ}$.

Retrieval and Quality Assessment of Atmospheric Winds from the Aircraft-Based Observation Near Incheon International Airport, Korea (인천 공항 주변 고해상도 항공기 추적 정보 기반의 바람 관측자료 생산 및 품질 검증)

  • Kim, Jeongmin;Kim, Jung-Hoon
    • Atmosphere
    • /
    • v.32 no.4
    • /
    • pp.323-340
    • /
    • 2022
  • We analyzed the high-resolution wind data of Aircraft-Based Observation from the Mode-Selective Enhanced Surveillance (Mode-S EHS) data in Korea. For assessment of its quality, the Mode-S wind data was compared with the ECMWF ReAnalysis 5 (ERA5) reanalysis and Aircraft Meteorological Data Relay (AMDAR) data for more than 3-months from 7 May 2021 to 24 August 2021 near Incheon International Airport, Korea. Considering that the AMDAR reports are not provided by all commercial aircraft, total number of the Mode-S derived wind data with a second sampling rate was about twice larger than that of available AMDAR wind data. After the quality control procedures by removing erroneous samples, it was found that the root mean square errors (RMSEs) of the Mode-S retrieved winds are similar to that from the AMDAR winds. In particular, between 550 and 650 hPa levels, RMSE of the Mode-S (AMDAR) zonal wind against ERA5 data was about 2.3 m s-1 (1.9 m s-1), and those increased to 3.3 m s-1 (2.4 m s-1) in 200~500 hPa levels. A similar trend was found in the meridional wind, but a distinct positive mean bias of 2.16 m s-1 was observed between 875 and 1,000 hPa levels. Winds retrieved from the Mode-S also showed a good agreement directly with AMDAR data. As the Mode-S provides a large amount of data with a reliable quality, it can be useful for both data assimilation in the numerical weather prediction model and situational awareness of wind and turbulence for aviation safety in Korea.

Evaluation of measuring accuracy of body position sensor device for posture correction (자세교정을 위한 체위변환 감지 센서 디바이스의 정확성 평가)

  • Choi, Jung-Hyeon;Park, Jun-Ho;Kang, Min-Ho;Seo, Jae-Yong;Kim, Soo-Chan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.128-133
    • /
    • 2021
  • Recently Recently, the incidence of spinal diseases due to poor posture among students and office workers is increasing, and various studies have been conducted to help maintain correct posture. In previous studies, a membrane sensor or a pressure sensor was placed on the seat cushion to see the weight bias, or a sensor that restrained the user was attached to measure the position change. In our previous study, we developed a sensor device which can be easily attached to the body with an adhesive gel sheet and that measures and outputs the user's posture and body position in real time, but it has a limitation in the accuracy of the sensor value. In this study, a study was conducted to improve the performance of the position conversion sensor device and quantitatively evaluate the accuracy of the angle conversion measurement value, and a high accuracy with 2.53% of error rate was confirmed. In future research, it is considered that additional research targeting actual users is needed by diversifying posture correction training contents with multimedia elements added.

A Systematic Review and Meta-Analysis of Pharmacopuncture Treatment for Insomnia Disorder (불면 장애에 대한 약침술 치료법 제안을 위한 체계적 문헌 고찰과 메타 분석 연구)

  • Jo, Min-Woo;Lim, Jung-Hwa;Kim, Bo-Kyung
    • Journal of Oriental Neuropsychiatry
    • /
    • v.32 no.3
    • /
    • pp.185-206
    • /
    • 2021
  • Objectives: The objective of this study was to perform a systematic review and meta-analysis of pharmacopuncture treatment for insomnia disorder to derive clinical evidence and recommendation grades. Methods: Studies that verified effects of pharmacopuncture on primary insomnia were included. Characteristics and quality of included studies were assessed using Risk of Bias (RoB). Results: A total of 25 studies were selected. Pittsburgh Sleep Quality Index (PSQI) and effective rate were primarily used for outcome measurement. Vitamin B12 was the most used pharmacopuncture material. The most frequently used acupuncture point was Anmian (Ex-HN). The volume of the acupuncture solution ranged from 0.25 mL to 2 mL. Acupuncture treatment depth was 0.5 cm to 2 cm. In three studies, the procedure was performed at 16:00. Meta-analysis of studies revealed that the effective rate of the pharmacopuncture group was significantly higher than the group using sleeping pills group (RR: 1.21, 95% CI: 1.01 to 1.45, p=0.04, I2=69%). PSQI was decreased in the intervention group (MD=-2.19, 95% CI: -2.90 to -1.48, p<0.00001, I2=0%). Effective rates of pharmacopuncture and acupuncture groups were higher than that of the acupuncture group (RR: 1.11, 95% CI: 1.05 to 1.17, p=0.0002, I2=0%). PSQI was decreased in the intervention group (MD=-1.87, 95% CI: -2.36 to -1.38, p<0.00001, I2=0%). Although the effectiveness rate of the pharmacopuncture group was not significantly higher than that of the acupuncture group (RR: 1.12, 95% CI: 0.98 to 1.27, p=0.1, I2=9%), the PSQI was decreased in the pharmacopuncture group (MD=-2.10, 05% CI: -3.29 to -0.91, p=0.0005, I2=34%). The quality of clinical studies was poor. Conclusions: Based on results of this study, it is proper to use 0.5 to 2 mL of pharmacopuncture solution such as Danshen and Ciwujia with a depth of 0.5 to 2 cm at around 4 p.m. to treat insomnia disorder, focusing on Anmian (Ex-HN) and Sameumgyo (SP6).