• 제목/요약/키워드: rapid load testing

검색결과 19건 처리시간 0.022초

강용접부의 응력부식크랙감수성 평가에 관한 연구 I -재료특성과 변형률 속도- (Evaluation of SCC Susceptibility of Weld HAZ in Structural Steel(I) -material properties and strain rate-)

  • 임재규;정대식;정세희
    • Journal of Welding and Joining
    • /
    • 제11권3호
    • /
    • pp.48-60
    • /
    • 1993
  • The cause of corrosion failure found in structures or various components operating in severe corrosive environments has been attributed to stress corrosion cracking(SCC)which is resulting from the combined effects of corrosive environments and static tensile stress. Slow strain rate test (SSRT) provides a rapid reliable method to determine SCC susceptibility of metals and alloys for a broad range of application. The chief advantage of SSRT procedures is that it is much more aggressive in producing SCC than conventional constant strain or constant load tests, so that the testing time is considerably reduced. Therefore, in this paper, the combined effects of material properties and strain rate on the tensile ductility and fracture morphology of parents and weldment for SM45C, SCM440 and SM20C steels were examined and discussed in synthetic sea water. The susceptibility of SCC was the most severe under the strain rate of $1.0{\times}10^{-6} sec^{-1}$, and R.O.A. can be used for parent and maximum load for weldment to evaluate the parameter for SCC susceptibility.

  • PDF

국소의치용 티나늄의 피로도 및 물리적 성질에 관한 연구 (A STUDY ON THE FATIGUE AND PHYSICAL PROPERTIES OF TITANIUM USED IN REMOVABLE PARTIAL DENTURES)

  • 김학선;김광남;장익태
    • 대한치과보철학회지
    • /
    • 제32권2호
    • /
    • pp.249-267
    • /
    • 1994
  • The purpose of this study was to compare the fatigue, physical properties, flexibility and surface roughness of titanium used in removable partial dentures with those of a type IV and alloy and a cobalt- chromium alloy. Fatigue testing subjected the test specimen to rapid cycling at a given stress until failure occurred by using a small-sized, electrodynamic type bending fatigue testing machine. The S-N curves for the framework materials were generated. For tensile testing, a tensile bar as described in the ADA Specification No.14 was subjected to tensile loading until failure occurred. Load-displacement curves were generated for 18 gauge round specimen and tapered half round specimen. Then the flexibilities were calculated. The surface roughnesses were compared by analyzer. Through analyses of the data, the following conclusions were obtained. 1. The fatigue property of titanium was higher than that of a type IV gold alloy$(p\leq0.05)$, but there was no significant difference between titanium and a cobalt-chromium alloy $(p\geq0.05)$. 2. The yield strength, the ultimate tensile strength and Victors hardness of titanium were higher than those of a type IV gold alloy but lower than those of a coalt-chromium alloy$(p\leq0.05)$. 3. The percentage of elongation and reduction of area of titanium were the highest $(p\leq0.05)$. 4. The surface roughness of titanium was the greatest$(p\leq0.05)$. 5. The flexibility of titanium was lower than that of a type IV gold alloy but higher than that of a cobalt-chromium alloy$(p\leq0.05)$.

  • PDF

변곡점법에 의한 신속 압밀시험 (Rapid Consolidation Test Using Inflection Point Method)

  • 민덕기;황광모;최규환
    • 한국지반공학회논문집
    • /
    • 제18권4호
    • /
    • pp.85-93
    • /
    • 2002
  • 본 연구에서는 Cour(1971)가 제안한 변곡점법(Inflection Point Method)을 이용하여 압밀계수를 예측하기 위한 새로운 방법을 소개하였다. 여기서, 변곡점은 압밀도(U)와 시간계수(log T) 관계곡선의 변곡점 중에서 압밀도($U_i$)가 70.03% 일 때의 시간계수 $T_i$=0.405에 상응하는 점이다. 제안된 변곡점법에 의한 신속한 압밀시험 방법에서 각 단계별 하중재하는 변곡점을 확인한 직후에 이루어지므로 압밀시험에 소요되는 시간을 단축시킬 수 있으며, 압밀계수를 빠른 시간 내에 쉽게 구할 수 있다. 이 신속한 압밀시험법에 소요되는 시간은 기존의 압밀시험의 경우 1주 또는, 2주의 기간이 소요되는데 비하여 0.5시간~9시간이 소요되므로 압밀시험을 보다 신속히 완료할 수 있다. 본 연구에서는 보다 정규화된 결과를 얻고자 침강장치를 고안하였으며, 그 결과의 분석에서 비 교란시료의 압밀정수들과 잘 부합하는 것으로 나타났다.

Resazurin 환원법을 응용한 돈육의 신속 미생물 검사법에 관한 연구 (Studies on Rapid Microbiological Testing Method of Fresh Pork by Applied Resazurin Reduction Test(RRT) Method)

  • 임상동;김기성
    • Journal of Animal Science and Technology
    • /
    • 제44권4호
    • /
    • pp.453-458
    • /
    • 2002
  • 본 연구는 실험방법이 간단하고 분석비용이 저렴하며, 단시간내에 세균수를 측정할 수 있는 현장적용 가능한 방법을 확립하기 위하여 냉장우육의 총균수를 표준평판배양법과 배양온도를 25$^{\circ}C$, 30$^{\circ}C$, 35$^{\circ}C$ 별로 레자주린 환원색과 환원시간을 측정하여 상관관계를 산출하였다. 연구결과를 보면, 총균수(25$^{\circ}C$/72시간, Y)와 레자주린 환원시간(X)과의 상관계수는 RRT (Resazurin reduction test) 배양온도가 25$^{\circ}C$와 30$^{\circ}C$, 환원색은 청색에서 분홍색으로 변할 때가 각각 -0.95와 -0.94로서 가장 높았다. 상관계수와 환원시간을 감안할 때 RRT 배양온도는 30$^{\circ}C$가 적합하였으며, 이때 회귀방정식은 Y = -0.4386X+7.7870이었으며, 돼지고기의 총균수가 $10^2$, $10^3$, $10^4$cfu/$cm^2$일 경우 검사시간은 13.2시간, 10.9시간, 8.6시간이었다. 총균수(30$^{\circ}C$/72시간, Y)와 레자주린 환원시간(X)과의 상관계수는 RRT 배양온도가 30$^{\circ}C$, 환원색은 청색에서 분홍색으로 변할 때가 -0.93으로서 가장 높았다. 이때 회귀방정식은 Y=-0.4171X+7.5540이었으며, 돼지고기의 총균수가 $10^2$, $10^3$, $10^4$ cfu/$cm^2$일 경우 검사시간은 13.3시간, 10.9시간, 8.5시간이었다. 총균수(35$^{\circ}C$/48시간, Y)와 레자주린 환원시간(X)과의 상관계수는 RRT 배양온도가 30$^{\circ}C$, 환원색은 청색에서 분홍색으로 변할 때가 -0.93으로서 가장 높았다. 이때 회귀방정식은 Y=-0.3514X + 6.7513이었으며, 돼지고기의 총균수가 $10^2$, $10^3$, $10^4$cfu/$cm^2$일 경우 검사시간은 13.5시간, 10.7시간, 7.8시간이었다.

Membrane용 오스테나이트계 304 스테인리스강 판재의 3점 굽힘피로 특성 (Three-Point Bending Fatigue Properties of Austenitic 304 Stainless Steel Sheets for Membrane)

  • 이태호;김성준;김형식;김철만;홍성호
    • 한국가스학회지
    • /
    • 제3권3호
    • /
    • pp.1-8
    • /
    • 1999
  • Membrane용 오스테나이트계 304 스테인리스강 판재의 3점 굽힘피로 특성에 관한 연구를 상온 및 LNG 온도인 $-162^{\circ}C$, 변형량 $0.43{\~}1.70\%$ 범위에서 수행하였다. 저온에서의 굽힘피로 특성이 상온보다 우수한 것으로 나타났고, 이는 변형유기 마르텐사이트 변태에 필요한 구동력이 적어서 보다 많은 양의 마르텐사이트를 함유했기 때문으로 판단된다. 상온 및 저온 모두에서 반복경화 현상이 관찰되었으며, 이러한 반복경화는 상온의 경우 피로주기가 반복됨에 따라 점진적으로 증가되지만 저온의 경우 초기 피로주기에서 급격히 증가된 후 점차로 감소하거나 일정한 값을 나타내었는데 이러한 차이는 저온의 경우 초기에 급격히 변형유기 마르텐사이트가 생성되지만 상온의 경우 변형유기 마르텐사이트 생성에는 일정한 소성변형의 축적이 필요하기 때문으로 생각된다. 기존의 JGA 연구결과와 비교해 볼 때 본 연구에서 사용된 국산소재의 굽힘피로 특성이 우수한 것으로 나타났다.

  • PDF

Wireless operational modal analysis of a multi-span prestressed concrete bridge for structural identification

  • Whelan, Matthew J.;Gangone, Michael V.;Janoyan, Kerop D.;Hoult, Neil A.;Middleton, Campbell R.;Soga, Kenichi
    • Smart Structures and Systems
    • /
    • 제6권5_6호
    • /
    • pp.579-593
    • /
    • 2010
  • Low-power radio frequency (RF) chip transceiver technology and the associated structural health monitoring platforms have matured recently to enable high-rate, lossless transmission of measurement data across large-scale sensor networks. The intrinsic value of these advanced capabilities is the allowance for high-quality, rapid operational modal analysis of in-service structures using distributed accelerometers to experimentally characterize the dynamic response. From the analysis afforded through these dynamic data sets, structural identification techniques can then be utilized to develop a well calibrated finite element (FE) model of the structure for baseline development, extended analytical structural evaluation, and load response assessment. This paper presents a case study in which operational modal analysis is performed on a three-span prestressed reinforced concrete bridge using a wireless sensor network. The low-power wireless platform deployed supported a high-rate, lossless transmission protocol enabling real-time remote acquisition of the vibration response as recorded by twenty-nine accelerometers at a 256 Sps sampling rate. Several instrumentation layouts were utilized to assess the global multi-span response using a stationary sensor array as well as the spatially refined response of a single span using roving sensors and reference-based techniques. Subsequent structural identification using FE modeling and iterative updating through comparison with the experimental analysis is then documented to demonstrate the inherent value in dynamic response measurement across structural systems using high-rate wireless sensor networks.

Experimental and analytical study of squat walls with alternative detailing

  • Leonardo M. Massone;Cristhofer N. Letelier;Cristobal F. Soto;Felipe A. Yanez;Fabian R. Rojas
    • Computers and Concrete
    • /
    • 제33권5호
    • /
    • pp.497-507
    • /
    • 2024
  • In squat reinforced concrete walls, the displacement capacity for lateral deformation is low and the ability to resist the axial load can quickly be lost, generating collapse. This work consists of testing two squat reinforced concrete walls. One of the specimens is built with conventional detailing of reinforced concrete walls, while the second specimen is built applying an alternative design, including stirrups along the diagonal of the wall to improve its ductility. This solution differs from the detailing of beams or coupling elements that suggest building elements equivalent to columns located diagonally in the element. The dimensions of both specimens correspond to a wall with a low aspect ratio (1:1), where the height and length of the specimen are 1.4 m, with a thickness of 120 mm. The alternative wall included stirrups placed diagonally covering approximately 25% of the diagonal strut of the wall with alternative detailing. The walls were tested under a constant axial load of 0.1f'cAg and a cyclic lateral displacement was applied in the upper part of the wall. The results indicate that the lateral strength is almost identical between both specimens. On the other hand, the lateral displacement capacity increased by 25% with the alternative detailing, but it was also able to maintain the 3 complete hysteretic cycles up to a drift of 2.5%, reaching longitudinal reinforcement fracture, while the base specimen only reached the first cycle of 2% with rapid degradation due to failure of the diagonal compression strut. The alternative design also allows 46% more energy dissipation than the conventional design. A model was used to capture the global response, correctly representing the observed behavior. A parametric study with the model, varying the reinforcement amount and aspect ratio, was performed, indicating that the effectiveness of the alternative detailing can double de drift capacity for the case with a low aspect ratio (1.1) and a large longitudinal steel amount (1% in the web, 5% in the boundary), which decreases with lower amounts of longitudinal reinforcement and with the increment of aspect ratio, indicating that the alternative detailing approach is reasonable for walls with an aspect ratio up to 2, especially if the amount of longitudinal reinforcement is high.

만성기도폐쇄 환자에서 최대운동부하시 관찰되는 호흡양상 - 기도폐쇄정도와 흡기책임비율변화 사이의 상관관계 - (The Changes of Breathing Pattern Observed During Maximal Exercise Testing in the Patients with Chronic Airflow Obstruction : the Correlation Between the Change of Inspiratory Duty Cycle and the Degree of Airflow Obstruction)

  • 이계영;지영구;김건열
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권3호
    • /
    • pp.574-582
    • /
    • 1997
  • 연구배경 : 정상인에서는 운동부하시 증가되는 환기량의 요구를 초기에는 상시호흡량의 증가로 후기에는 호흡수의 증가로 충족시키며, 호흡수 증가에 따라 유발되는 호흡주기의 감소를 보상하기 위해 흡기책임비율이 50% 이상까지 증가하는 것으로 알려져 있다. 반면 만성기도폐쇄 환자에서는 환기능력의 감소와 생리적 사강 호흡의 증가로 인해 최대운동부하시 얕고 빠른 호흡양상을 보인다고 알려져 있지만 책임비율의 변화에 대해서는 연구가 많지 않고 이와 기도폐쇄정도와의 관련성에 대해서는 보고가 없는 실정이다. 방 법 : 12명의 만성기도폐쇄 환자와 10명의 정상인을 대조로 점진적 최대운동부하검사를 실시하였다. 결과 분석은 안정시에서 최대운동부하시점까지의 시간을 100%로 하여 rest, 20%, 40%, 60%, 80%, max 등% control duration으로 분획한 후 각 시점에서 1분 환기량, 상시호흡량, 호흡수, 생리적 사강비율, 흡기책임비율 등의 지표를 양군 간에 비교하였다. 결 과 : 1분환기량과 상시호흡량의 안정시에서 최대운동시까지의 변화는 양군 간에 유의한 차이가 관찰되었으나 호흡수는 유의한 차이를 나타내지 않았다. 생리적사강 비율은 정상대조군에 비해 만성기도폐쇄군에서 그 감소가 유의하게 낮았다. 흡기책임비율은 정상대조군에서 $38.4{\pm}3.0%$에서 $48.6{\pm}4.5%$로 증가한 반면 만성기도폐쇄군에서는 $40.5{\pm}2.2%$에서 $42.6{\pm}3.5%$로 별 변화가 없어 양군간에 유의한 변화의 차이가 있음을 확인할 수 있었고 이러한 흡기책임비율의 변화는 기도폐쇄정도 (FEV1%)와 유의한 상관관계가 있음을 확인할 수 있었다. (r=0.8151, p<0.05). 결 론 : 이상의 결과에서 만성기도폐쇄 환자는 최대운동부하시 정상에서 관찰되는 흡기책임비율의 증가가 발생하지 않으며 이는 기도폐쇄의 정도와 유의한 상관성을 갖고 있음을 확인할 수 있었다.

  • PDF

손 위생 제품에 대한 in vitro, ex vivo, in vivo 항균 시험법 비교 (Comparison of In Vitro, Ex Vivo, and In Vivo Antibacterial Activity Test Methods for Hand Hygiene Products)

  • 이다은;여현주;정혜윤
    • 한국식품위생안전성학회지
    • /
    • 제39권1호
    • /
    • pp.35-43
    • /
    • 2024
  • 손 위생 제품이 다양화됨과 동시에 각 활용 방법에 따라 그 효능을 평가하는 여러 시험 방법들이 보고되고 있다. 하지만 평가 방법에 따라 각 제품의 항균 효능은 다르게 나타나며, 이로 인해 제품의 실제적인 효능을 확인하는 데에 어려움이 있을 수 있다. 손 위생 제품의 효능평가방법 비교에 초점을 둔 연구는 매우 제한적이며, 특히 돼지피부를 이용한 ex vivo에 대한 연구는 극히 드물다. 이에 본 연구는 손 위생 제품 중 리브온 소독제와 워시오프 세정제에 대해 각각의 항균 평가 방법을 종합적으로 비교했고, ex vivo 시험에 영향을 미칠 수 있는 요인을 파악하여 연구 단계에서 효율적인 ex vivo 시험의 신뢰성을 향상시키고자 하였다. in vitro 시험으로써 액체 현탁을 기반으로 하는 time-kill 시험을 진행했고, in vivo 시험은 최소 20명의 참여자를 대상으로 진행되었다. ex vivo 시험은 규격화된 돼지 피부를 이용하여 in vivo 시험과 동일한 방법으로 진행하면서 소독제의 최적 처리량과 세정제 사용 시 첨가되는 물의 양을 제안했다. 시험에 사용된 손 소독제는 in vitro 시험에서 모두 5 log 이상의 세균 감소율을 보인 반면, ex vivo와 in vivo에서는 훨씬 낮은 살균 활성을 보였으며, 특히 알코올 함량이 낮은 손 소독제에서는 1 log 미만의 살균 활성을 나타냈다. 반면에 손 세정제의 in vitro 시험 결과, 대장균에 대해서는 1 log 이하의 낮은 항균력을 보였으나, ex vivo 와 in vivo 시험 결과에서는 이보다 높은 항균력을 유사하게 나타냈다. 본 연구에서는 ex vivo 와 in vivo 시험 방법이 리브온과 워시오프 타입 제품의 두가지 다른 항균 메커니즘을 반영할 수 있음을 확인했다. 이로 인해 최적의 조건으로 설정된 ex vivo 시험은 빠르고 정확한 항균 평가법이 될 수 있음을 제시한다.