• Title/Summary/Keyword: rapid imaging

Search Result 328, Processing Time 0.031 seconds

A Study on Usefulness of Specific Agents with Liver Disease at MRI Imaging: Comparison with Ferucarbotran and Gd-EOB-DTPA Contrast Agents (간 병변 특이성 조영제 자기공명영상에 대한 연구: Ferucarbotran과 Gd-EOB-DTPA 조영제의 비교)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Park, Cheol-Soo;Lee, Sun-Yeob;Choi, Yong-Seok
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.235-243
    • /
    • 2009
  • The purpose of this experiment is to know the relation of the detection and characterization of liver's diseases as comparison of finding at MR imaging using a Ferucarbotran (SPIO) and Gd-EOB-DTPA (Primovist) agents in diffuse liver disease. A total of 50 patients (25 men and 25 women, mean age: 50 years) with liver diseases were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) "with 8 Ch body coil for comparison of diseases and contrast's uptake relation, which used the LAVA, MGRE." All images were performed on the same location with before and after Ferucarbotran and Gd-EOB-DTPA administrations (p<0.05). Contrast to noise ratio of Ferucarbotran and Gd-EOB-DTPA in the HCC were $3.08{\pm}0.12$ and $7.00{\pm}0.27$ with MGRE and LAVA pulse sequence, $3.62{\pm}0.13$ and $2.60{\pm}0.23$ in the hyper-plastic nodule, $1.70{\pm}0.09$ and $2.60{\pm}0.23$ in the meta, $2.12{\pm}0.28$ and $5.86{\pm}0.28$ in the FNH, $4.45{\pm}0.28$ and $1.73{\pm}0.02$ in the abscess and ANOVA test was used to evaluate the diagnostic performance of each disease (p<0.05). In conclusions, two techniques were well demonstrated with the relation of the detection and characterization of liver's diseases.

  • PDF

Usefulness of Ultrasonographic Examination by a Pediatrician in Children with Abdominal Pain (소아 복통에서 소아과 의사에 의한 초음파 검사의 유용성)

  • Park, Hyun-Seok;We, Ju-Hee;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.14 no.2
    • /
    • pp.141-147
    • /
    • 2011
  • Purpose: Ultrasonography (US) is widely used as a screening test in patients with abdominal pain (AP). We investigated the usefulness of US by a pediatrician in children with AP. Methods: We retrospectively analysed the medical records of children with AP who undertook US from December, 2008 to July, 2010. Results: A total of 628 patients (325 male, 303 female) were enrolled in this study. The mean age of patients was $8.08{\pm}4.61$ years. Duration of AP was acute in 427 and chronic in 201 patients. Localization of AP was diffuse (36.9%), periumbilical (24.4%), epigastric (21.0%), and right lower quadrant (8.1%). On the examination, there were no abnormal findings in 327 patients (52.1%). Abnormal ultrasonographic findings were mesenteric lymphadenitis (27.1%), intestinal mural thickening (10.0%), intussusception (3.0%), appendicitis (2.6%), choledochal cyst (1.6%), and pancreatitis (0.3%). We performed additional imaging studies such as computed tomography (CT) or magnetic resonance imaging (MRI) in 39 patients who showed obscure findings on the US. In 33 patients (84.6%), the same results were obtained from CT or MRI. Two cases of appendicitis, one case of pancreatitis and one case of Henoch-Sh$\ddot{o}$nlein purpura were diagnosed by the CT examination. However, there were two cases of appendicitis diagnosed by US thathad no evidence of appendicitis on the CT. Diagnostic accuracy of initial US in children with abdominal pain was 99.4%. Conclusion: US by a pediatrician as a screening test in children with AP provides a rapid and accurate diagnostic indication and has non-invasive and radiation-free advantages.

Thermal Characteristics of Daegu using Land Cover Data and Satellite-derived Surface Temperature Downscaled Based on Machine Learning (기계학습 기반 상세화를 통한 위성 지표면온도와 환경부 토지피복도를 이용한 열환경 분석: 대구광역시를 중심으로)

  • Yoo, Cheolhee;Im, Jungho;Park, Seonyoung;Cho, Dongjin
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.6_2
    • /
    • pp.1101-1118
    • /
    • 2017
  • Temperatures in urban areas are steadily rising due to rapid urbanization and on-going climate change. Since the spatial distribution of heat in a city varies by region, it is crucial to investigate detailed thermal characteristics of urban areas. Recently, many studies have been conducted to identify thermal characteristics of urban areas using satellite data. However,satellite data are not sufficient for precise analysis due to the trade-off of temporal and spatial resolutions.In this study, in order to examine the thermal characteristics of Daegu Metropolitan City during the summers between 2012 and 2016, Moderate Resolution Imaging Spectroradiometer (MODIS) daytime and nighttime land surface temperature (LST) data at 1 km spatial resolution were downscaled to a spatial resolution of 250 m using a machine learning method called random forest. Compared to the original 1 km LST, the downscaled 250 m LST showed a higher correlation between the proportion of impervious areas and mean land surface temperatures in Daegu by the administrative neighborhood unit. Hot spot analysis was then conducted using downscaled daytime and nighttime 250 m LST. The clustered hot spot areas for daytime and nighttime were compared and examined based on the land cover data provided by the Ministry of Environment. The high-value hot spots were relatively more clustered in industrial and commercial areas during the daytime and in residential areas at night. The thermal characterization of urban areas using the method proposed in this study is expected to contribute to the establishment of city and national security policies.

Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography (미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석)

  • Bae, In-Ho;Koh, Jeong-Tae;Lim, Kyung-Seob;Park, Dae-Sung;Kim, Jong-Min;Jeong, Myung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • Micro-computed tomography (microCT) is an important tool for preclinical vascular imaging, with micron-level resolution. This non-destructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize specimens prior to destructive analysis such as pathological analysis. Objectives. The aim of this study was to suggest a method for ex vivo, postmortem examination of stented arterial segments with microCT. And ex vivo evaluation of stents such as bare metal or drug eluting stents on in-stent restenosis (ISR) in rabbit model was performed. The bare metal stent (BMS) and drug eluting stent (DES, paclitaxel) were implanted in the left or right iliac arteries alternatively in eight New Zealand white rabbits. After 4 weeks of post-implantation, the part of iliac arteries surrounding the stent were removed carefully and processed for microCT. Prior to microCT analysis, a contrast medium was loaded to lumen of stents. All samples were subjected to an X-ray source operating at 50 kV and 200 ${\mu}A$ by using a 3D isotropic resolution. The region of interest was traced and measured by CTAN analytical software. Objects being exposed to radiation had different Hounsfield unit each other with values of approximately 1.2 at stent area, 0.12 ~ 0.17 at a contrast medium and 0 ~ 0.06 at outer area of stent. Based on above, further analyses were performed. As a result, the difference of lengths and volumes between expanded stents, which may relate to injury score in pathological analysis, was not different significantly. Moreover, ISR area of BMS was 1.6 times higher than that of DES, indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. And ISR area of BMS was higher ($1.52{\pm}0.48mm^2$) than that of DES ($0.94{\pm}0.42mm^2$), indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. Though it was not statistically significant, it showed that the extent of neointema of mid-region of stents was relatively higher than that of anterior and posterior region in parts of BMS as showing cross-sectional 2-D image. suggest that microCT can be utilized as an accessorial tool for pathological analysis.

A Study of Inter-observer Agreements of Spiral Chest Computed Tomography in Diagnosing Pulmonary Embolism (폐색전증에서 나선형 컴퓨터 전산화 단층촬영의 관찰자간의 일치도에 관한 연구)

  • Kim, Yang-Ki;Lee, Young Mok;Kim, Ki-up;Uh, Soo-taek;Kim, Yong Hoon;Park, Choon Sik;Hwang, Jung-Hwa;Kim, Dong Hun;Goo, Dong-Erk;Choi, Deuk-Lin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.5
    • /
    • pp.473-479
    • /
    • 2005
  • Background : A pulmonary embolism often presents with nonspecific symptoms and signs. However, a delayed diagnosis can result in catastrophic outcome. The majority of preventable deaths associated with a pulmonary embolism can be ascribed to a missed diagnosis rather than to the failure of existing treatments. Therefore, accurate and rapid diagnostic methods are essential for the management of a pulmonary embolism. The recent generation of multidetector-row spiral CT scanners appears to outperform other imaging modalities in detecting a central and peripheral pulmonary embolism. However, there are some variations in the interpretations of the findings between observers. This study examined the inter-observer differences of the diagnoses in patients with a pulmonary embolism. Method : 64 patients who were diagnosed with a pulmonary embolism either clinically or with spiral chest CT from 2002 to 2004, were included. Two thoracic radiologists interpreted the multidetector-row spiral CT in terms of the diagnosis of a pulmonary embolism and the location of the thrombus independently. Among 64 patients, 14 patients were excluded because there was no evidence of a pulmonary embolism or there was different interpretation of the pulmonary embolism between radiologists. A clinical diagnosis was based on "Rules for predicting the probability of embolism". Results : The mean score of the patients according to the Wells method was $3.91{\pm}0.30$ (0-9). The accordance of the radiologists was 95% in the main, 85% in the lobar, 91.2% in the segmental, and 96% in the sub-segmental pulmonary arteries. After excluding the negative interpretation from both radiologists, their agreement was 76.2%(${\kappa}.$ 0.83) in the main, 57.6%(${\kappa}.$ 0.63) in the lobar, 51.5%(${\kappa}.$ 0.63) in the segmental, and 34.6%(${\kappa}.$ 0.49) in the sub-segmental pulmonary arteries. Conclusion : Chest CT has been recently applied to patients suspected of having a pulmonary embolism. It was found that spiral CT is a rapid test for diagnosing a thrombus, and there was reliable accordance between the observers from the area of the large pulmonary arteries. However, there was a lack of agreement between the observers in diagnosing thrombi located distal to the sub-segmental arteries.

A Study on the Automation and Optimization of 9-(4-[$^{18}F$] Fluoro-3-hydroxymethylbutyl) Guanine Synthesis (9-(4-[$^{18}F$] Fluoro-3-hydroxymethylbutyl) guanine 합성의 자동화와 최적화에 관한 연구)

  • An, Jae-Seok;Hong, Sung-Tack;Kang, Se-Hun;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.72-75
    • /
    • 2011
  • Purpose: The HSV1-tk reporter gene system is the most widely used system because of its advantage is that it is possible to monitor directly without the introduction of a separate reporter gene in case of HSV1-tk suicide gene therapy. This study was performed to automate 9-(4-[$^{18}F$] Fluoro-3-hydroxymethylbutyl) guanine ([$^{18}F$] FHBG) that are widely used as substrate for the HSV1-tk reporter gene in living organisms with positron emission tomography (PET) and find the optimized conditions of synthesis. Materials and Methods: Fully automated synthesis of [$^{18}F$] FHBG was performed using Explora-RN (CTI, USA) module. We have changed of reaction time (3, 5, 10 min) and temperature (110, 120, $130^{\circ}C$) for the optimized conditions of synthesis. Also we experimented to find the optimal concentration of precursor (5, 7, 10 mg). Results: [$^{18}F$] FHBG was purified by HPLC system and collected at around 10-12 min. Synthesis using Explora-RN module showed a $32.0{\pm}1.2%$ yield of radiochemical (decay corrected), the purity was greater than 98%. And the entire synthesis time was less than 48 min. Temperature of the highest synthesis yield was $130^{\circ}C$, reaction time was 5 minutes and concentration of precursor was 10 mg (recommended volume in manual) (n=36). In contrast to radiochemical yield of precursor 10 mg ($32{\pm}1.2%$), yield of 5 and 7 mg precursor was unstable. Conclusion: Automation of [$^{18}F$] FHBG synthesis at Explora-RN module has been completed. In addition, we were able to obtain optimized reaction time, temperature and concentration of precursor. Therefore this study would be provided more rapid synthesis and higher radiochemical yield.

  • PDF

Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm (Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구)

  • Tan, Kee Chin;Kim, Tae-Hyung;Chun, Song-I;Han, Yong-Hee;Choi, Ki-Seung;Lee, Kwang-Sig;Jun, Jae-Ryang;Eun, Choong-Ki;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • Purpose : To investigate the feasibility and accuracy of Proton Resonance Frequency (PRF) shift based magnetic resonance (MR) temperature mapping utilizing the self-developed center array-sequencing phase unwrapping (PU) method for non-invasive temperature monitoring. Materials and Methods : The computer simulation was done on the PU algorithm for performance evaluation before further application to MR thermometry. The MR experiments were conducted in two approaches namely PU experiment, and temperature mapping experiment based on the PU technique with all the image postprocessing implemented in MATLAB. A 1.5T MR scanner employing a knee coil with $T2^*$ GRE (Gradient Recalled Echo) pulse sequence were used throughout the experiments. Various subjects such as water phantom, orange, and agarose gel phantom were used for the assessment of the self-developed PU algorithm. The MR temperature mapping experiment was initially attempted on the agarose gel phantom only with the application of a custom-made thermoregulating water pump as the heating source. Heat was generated to the phantom via hot water circulation whilst temperature variation was observed with T-type thermocouple. The PU program was implemented on the reconstructed wrapped phase images prior to map the temperature distribution of subjects. As the temperature change is directly proportional to the phase difference map, the absolute temperature could be estimated from the summation of the computed temperature difference with the measured ambient temperature of subjects. Results : The PU technique successfully recovered and removed the phase wrapping artifacts on MR phase images with various subjects by producing a smooth and continuous phase map thus producing a more reliable temperature map. Conclusion : This work presented a rapid, and robust self-developed center array-sequencing PU algorithm feasible for the application of MR temperature mapping according to the PRF phase shift property.

  • PDF

Ultrasonographic Evaluation in Patients with Inguinal Hernia (서혜부 탈장에서의 초음파 조영술)

  • Kwon, Oh-Kyoung;Jung, Jin-Hyang;Park, Jin-Young;Chang, Soo-Il
    • Advances in pediatric surgery
    • /
    • v.8 no.1
    • /
    • pp.16-22
    • /
    • 2002
  • Between March 1999 and January 2000, 82 boys with the diagnosis of inguinal hernias (12 bilateral and 70 unilateral hernias), underwent Ultrasound (US) examination of both sides of the groin, a total of 164 inguinal imaging prior to surgery. The patients ages ranged from 3 days to 12 years with a mean of 32.6 months. Ninty four examinations were on the clinically symptomatic side and 70 were on the asymptomatic side. The US criteria for the diagnosis of an inguinal hernia were as follows: 1) visceral hernia, the presence of bowel loops, or omentum in the inguinal canal, 2) communicating hydrocele, the presence of fluid in the processus vaginalis, 3) widening of patent processus vaginalis at the level of internal inguinal ring. The width of patent processus vaginalis at the level of internal inguinal ring over 4 mm is considered an occult hernia. Among the 94 symptomatic groins, US findings showed 31 (33%) visceral hernias, 18 (19%) communicating hydroceles, and 38 (41%) widening of the internal inguinal ring, and 7 (7%) groins without abnormalities. In 70 asymptomatic groins, there were 4 (6%) visceral hernias, 5 (7%) communicating hydroceles, 11 (16%) widening of the internal inguinal ring, and 50 (70%) groins without abnormalities. Among the 70 asymptomatic groins there were US abnormalities in 20 (28%). One hundred and seven groins with positive US findings were surgically explored. Among 107 operated sites, the operative findings were compatible with the US diagnosis in 104, a sensitivity for US of 97.2%. In patients with US findings of widening of internal inguinal ring (>4 mm), there was patent processus vaginalis in 36 out of 38 symptomatic groins and 10 of 11 asymptomatic groins. The sensitivity of US to the operative findings in widening of internal inguinal ring was 93.8%. For visceral hernia and communicating hydrocele, the sensitivity of positive US findings was 100%. Ultrasonography for inguinal hernias appears to be a rapid, reliable, and noninvasive screening diagnostic tool with high positive specificity. Therefore, we recommend the use of US as a routine diagnostic tool in pediatric patients with inguinal hernias and hydroceles.

  • PDF