• 제목/요약/키워드: rapid imaging

검색결과 332건 처리시간 0.024초

Hepatic Cavernous Hemangioma in Cirrhotic Liver: Imaging Findings

  • Jeong-Sik Yu;Ki Whang Kim;Mi-Suk Park;Sang-Wook Yoon
    • Korean Journal of Radiology
    • /
    • 제1권4호
    • /
    • pp.185-190
    • /
    • 2000
  • Objective: To document the imaging findings of hepatic cavernous hemangioma detected in cirrhotic liver. Materials and Methods: The imaging findings of 14 hepatic cavernous hemangiomas in ten patients with liver cirrhosis were retrospectively analyzed. A diagnosis of hepatic cavernous hemangioma was based on the findings of two or more of the following imaging studies: MR, including contrast-enhanced dynamic imaging (n = 10), dynamic CT (n = 4), hepatic arteriography (n = 9), and US (n = 10). Results: The mean size of the 14 hepatic hemangiomas was 0.9 (range, 0.5-1.5) cm in the longest dimension. In 11 of these (79%), contrast-enhanced dynamic CT and MR imaging showed rapid contrast enhancement of the entire lesion during the early phase, and hepatic arteriography revealed globular enhancement and rapid filling-in. On contrast-enhanced MR images, three lesions (21%) showed partial enhancement until the 5-min delayed phases. US indicated that while three slowly enhancing lesions were homogeneously hyperechoic, 9 (82%) of 11 showing rapid enhancement were not delineated. Conclusion: The majority of hepatic cavernous hemangiomas detected in cirrhotic liver are small in size, and in many, hepatic arteriography and/or contrast-enhanced dynamic CT and MR imaging demonstrates rapid enhancement. US, however, fails to distinguish a lesion of this kind from its cirrhotic background.

  • PDF

단감(Diospyros kaki)의 동상해 평가를 위한 엽록소 형광 이미지 분석법의 활용 (Application of Chlorophyll a Fluorescence Imaging Analysis for Selection of Rapid Frozen Sweet Persimmon Fruits)

  • 유성영;박소현;이민주;박종용;강홍규;강성구;김태완
    • 한국환경농학회지
    • /
    • 제34권3호
    • /
    • pp.210-216
    • /
    • 2015
  • BACKGROUND: In korea, sweet persimmon(Diospyros kaki) cultivation is front to abiotic stresses such as frost damage at fruit maturing stage. The cold and rapid freezing stresses are most damaging to fruit production which is most actively progressed in late fall. This study was performed to evaluate the validity of chlorophyll fluorescence imaging(CFI) technology to determine the degree of frost damage in sweet persimmon fruits. METHODS AND RESULTS: The sweet persimmon fruits were measured separately for each treatment(15, 30, 60 minutes) at 24 hours after treatment(HAT) rapid freezing. A CFI FluorCam (FC 1000-H, PSI, Czech Republic) was used to measure the fluorescence images of the fruits. In rapid freezing for 15 minutes, photochemical parameters were not changed. However, in rapid freezing for 30 and 60 minutes, photochemical parameters were lowered. Especially, $F_m$, $F_v$, $F_v/F_m$ and ${\Phi}PSII$ values were declined under rapid freezing. CONCLUSION: In our study, it was clearly indicated that the rapid freezing could be a stress in sweet persimmon fruits. The CFI analysis and its related parameters are applicable as a rapid assessing technique for the determination of frost damage.

Drug selection for sedation and general anesthesia in children undergoing ambulatory magnetic resonance imaging

  • Jung, Sung Mee
    • Journal of Yeungnam Medical Science
    • /
    • 제37권3호
    • /
    • pp.159-168
    • /
    • 2020
  • The demand for drug-induced sedation for magnetic resonance imaging (MRI) scans have substantially increased in response to increases in MRI utilization and growing interest in anxiety in children. Understanding the pharmacologic options for deep sedation and general anesthesia in an MRI environment is essential to achieve immobility for the successful completion of the procedure and ensure rapid and safe discharge of children undergoing ambulatory MRI. For painless diagnostic MRI, a single sedative/anesthetic agent without analgesia is safer than a combination of multiple sedatives. The traditional drugs, such as chloral hydrate, pentobarbital, midazolam, and ketamine, are still used due to the ease of administration despite low sedation success rate, prolonged recovery, and significant adverse events. Currently, dexmedetomidine, with respiratory drive preservation, and propofol, with high effectiveness and rapid recovery, are preferred for children undergoing ambulatory MRI. General anesthesia using propofol or sevoflurane can also provide predictable rapid time to readiness and scan times in infants or children with comorbidities. The selection of appropriate drugs as well as sufficient monitoring equipment are vital for effective and safe sedation and anesthesia for ambulatory pediatric MRI.

유전자 발현 영상기법 (Imaging Gene Expression)

  • 이경한
    • 대한핵의학회지
    • /
    • 제34권1호
    • /
    • pp.1-9
    • /
    • 2000
  • The rapid progress of molecular genetic methods over the past two decades has necessitated the development of methods to detect and quantify genetic activity within living bodies. Reporter genes provide a rapid and convenient tool to monitor gene expression by yielding a readily measurable phenotype upon expression when introduced into a biological system. Conventional reporter systems, however, are limited in their usefulness for in vivo experiments or human gene therapy because of its invasive nature which requires cell damage before assays can be performed. This offers an unique opportunity for nuclear imaging techniques to develope a novel method for imaging both the location and amount of gene expression noninvasively. Current developments to achieve this goal rely on utilizing either reporter enzymes that accumulate radiolabeled substrates or reporter receptors that bind specific radioligands. This overview includes a brief introduction to the background for such research, a summary of published results, and an outlook for future directions.

  • PDF

Use of Chlorophyll a Fluorescence Imaging for Photochemical Stress Assessment in Maize (Zea mays L.) Leaf under Hot Air Condition

  • Park, Jong Yong;Yoo, Sung Young;Kang, Hong Gyu;Kim, Tae Wan
    • 한국작물학회지
    • /
    • 제61권4호
    • /
    • pp.270-276
    • /
    • 2016
  • The objective of this study was to find a rapid determination of the hot air stress in maize (Zea mays L.) leaves using a portable chlorophyll fluorescence imaging instrument. To assess the photosynthetic activity of maize leaves, an imaging analysis of the photochemical responses of maize was performed with chlorophyll fluorescence camera. The observed chlorophyll imaging photos were numerically transformed to the photochemical parameters on the basis of chlorophyll a fluorescence. Chlorophyll a fluorescence imaging (CFI) method showed that a rapid decrease in maximum fluorescence intensity ($F_m$) of leaf occurred under hot air stress. Although no change was observed in the maximum quantum yield ($F_v/F_m$) of the hot air stressed maize leaves, the other photochemical parameters such as maximum fluorescence intensity ($F_m$) and Maximum fluorescence value ($F_p$) were relatively lowered after hot air stress. In hot air stressed maize leaves, an increase was observed in the nonphotoquenching (NPQ) and decrease in the effective quantum yield of photochemical energy conversion in photosystem II (${\Phi}PSII$). Thus, NPQ and ${\Phi}PSII$ were available to be determined non-destructively in maize leaves under hot air stress. Our results clearly indicated that the hot air could be a source of stress in maize leaves. Thus, the CFI analysis along with its related parameters can be used as a rapid indicating technique for the determining hot air stress in plants.

Multi-Temporal Spectral Analysis of Rice Fields in South Korea Using MODIS and RapidEye Satellite Imagery

  • Kim, Hyun Ok;Yeom, Jong Min
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권4호
    • /
    • pp.407-411
    • /
    • 2012
  • Space-borne remote sensing is an effective and inexpensive way to identify crop fields and detect the crop condition. We examined the multi-temporal spectral characteristics of rice fields in South Korea to detect their phenological development and condition. These rice fields are compact, small-scale parcels of land. For the analysis, moderate resolution imaging spectroradiometer (MODIS) and RapidEye images acquired in 2011 were used. The annual spectral tendencies of different crop types could be detected using MODIS data because of its high temporal resolution, despite its relatively low spatial resolution. A comparison between MODIS and RapidEye showed that the spectral characteristics changed with the spatial resolution. The vegetation index (VI) derived from MODIS revealed more moderate values among different land-cover types than the index derived from RapidEye. Additionally, an analysis of various VIs using RapidEye satellite data showed that the VI adopting the red edge band reflected crop conditions better than the traditionally used normalized difference VI.

Short-term treatment effects produced by rapid maxillary expansion evaluated with computed tomography: A systematic review with meta-analysis

  • Giudice, Antonino Lo;Spinuzza, Paola;Rustico, Lorenzo;Messina, Gabriele;Nucera, Riccardo
    • 대한치과교정학회지
    • /
    • 제50권5호
    • /
    • pp.314-323
    • /
    • 2020
  • Objective: To identify the available evidence on the effects of rapid maxillary expansion (RME) with three-dimensional imaging and provide meta-analytic data from studies assessing the outcomes using computed tomography. Methods: Eleven electronic databases were searched, and prospective case series were selected. Two authors screened all titles and abstracts and assessed full texts of the remaining articles. Seventeen case series were included in the quantitative synthesis. Seven outcomes were investigated: nasal cavity width, maxillary basal bone width, alveolar buccal crest width, alveolar palatal crest width, inter-molar crown width, inter-molar root apex width, and buccopalatal molar inclination. The outcomes were investigated at two-time points: post-expansion (2-6 weeks) and post-retention (4-8 months). Mean differences and 95% confidence intervals were used to summarize and combine the data. Results: All the investigated outcomes showed significant differences post-expansion (maxillary basal bone width, +2.46 mm; nasal cavity width, +1.95 mm; alveolar buccal crest width, +3.90 mm; alveolar palatal crest width, +3.09 mm; intermolar crown width, +5.69 mm; inter-molar root apex width, +2.85 mm; and dental tipping, +3.75°) and post-retention (maxillary basal bone width, +2.21 mm; nasal cavity width, +1.55 mm; alveolar buccal crest width, +3.57 mm; alveolar palatal crest width, +3.32 mm; inter-molar crown width, +5.43 mm; inter-molar root apex width, +4.75 mm; and dental tipping, 2.22°) compared to pre-expansion. Conclusions: After RME, skeletal expansion of the nasomaxillary complex was greater in most caudal structures. Maxillary basal bone showed 10% post-retention relapse. During retention period, uprighting of maxillary molars occurred.

신속 조형 기술로 제작된 인체모형을 이용한 술전 모의 두개악안면성형수술 (3-Dimensional Model Simulation Craniomaxillofacial Surgery using Rapid Prototyping Technique)

  • 정경인;백롱민;임주환;박성규;허찬영;김명국;권순성
    • Archives of Plastic Surgery
    • /
    • 제32권6호
    • /
    • pp.796-797
    • /
    • 2005
  • In plastic and reconstructive craniomaxillofacial surgery, careful preoperative planning is essential to get a successful outcome. Many craniomaxillofacial surgeons have used imaging modalities like conventional radiographs, computed tomography(CT) and magnetic resonance imaging(MRI) for supporting the planning process. But, there are a lot of limitations in the comprehension of the surgical anatomy with these modalities. Medical models made with rapid prototyping (RP) technique represent a new approach for preoperative planning and simulation surgery. With rapid prototyping models, surgical procedures can be simulated and performed interactively so that surgeon can get a realistic impression of complex structures before surgical intervention. The great advantage of rapid prototyping technique is the precise reproduction of objects from a 3-dimensional reconstruction image as a physical model. Craniomaxillofacial surgeon can establish treatment strategy through preoperative simulation surgery and predict the postoperative result.

다중 분자 영상을 위한 간편한 동물 특이적 자세 고정틀의 제작 (Facile Fabrication of Animal-Specific Positioning Molds For Multi-modality Molecular Imaging)

  • 박정찬;오지은;우승태;곽원정;이정은;김경민;안광일;최태현;천기정;장용민;이상우;안병철;이재태;유정수
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권5호
    • /
    • pp.401-409
    • /
    • 2008
  • 목적: 최근 들어, 분자 영상에서 다중 영상 기법이 널리 보급되고 있다. 우리는 PET/MR 융합 영상을 얻기 위해 쉽게 이용 가능한 점토와 순간 고형제를 이용하여 동물 특이적 자세 고정 틀을 제작하였다. 동물 특이적 자세 고정 틀은 동물의 고정과 재현성 있는 자세 연출이 가능하도록 한다. 여기에서 우리는 실험 동물의 틀을 제작하는데 있어 점토와 순간 고형제를 비교해 보았다. 재료 및 방법: MicroPET의 받침대와 잘 맞는 바닥이 둥근 아크릴 받침대를 먼저 제작하였다. 실험 동물은 마취 후, 자세 고정을 위해서 틀 위에 올려놓았다. 틀 제작을 위하여 순간 고형제와 점토가 사용되었다. 순간 고형제와 점토를 사용한 두 가지 경우 모두, 실험 동물의 자세 고정을 위하여 부드럽게 실험 동물을 눌러 위치를 잡았다. 위치가 잡혔으면, 쥐를 들어내고, 점토로 뜬 틀은 $60^{\circ}C$ 건조기에 넣어 두어 완전히 경화시켰다. 그리고 $[^{18}F]FDG$용액이 든 밀봉된 4개의 파이펫 팁을 기준 마커로 사용하였다. 실험 동물의 꼬리에 $[^{18}F]FDG$를 정맥 주사하여 microPET 스캔을 실시한 후, 동일한 실험동물을 순차적으로 MRI 스캔하였다. 결과: 다중 영상을 위하여 점토와 순간 고형제로 동물 특이적 자세 고정 틀을 제작하였다. MicroPET과 MRI를 통하여 기능적이고 해부학적인 영상을 얻었다. PET/MR 융합 영상은 무료로 이용 가능한 AMIDE 프로그램을 사용하여 획득할 수 있었다. 결론: 쉽게 이용 가능한 점토, 순간 고형제와 일회용 파이펫 팁을 사용하여 성공적으로 동물 특이적 자세 고정 틀을 제작할 수 있었다. 동물 특이적 자세 고정 틀 덕택으로, 적은 오차 범위 내에서 PET/MR 융합 영상을 얻을 수 있었다.

Matching Pursuit 방법을 이용한 MR영상법에 관한 연구 (Magnetic Resonance Imaging Using Matching Pursuit)

  • 노용만
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.230-234
    • /
    • 1997
  • The matching pursuit (MP) algorithm developed by S. Mallat and Z. Zhang is applied to magnetic resonance (MR) imaging. Since matching pursuit is a greedy algorithm to find waveforms which are the best match for an object-signal, the signal can be decomposed with a few iterations. In this paper, we propose an application of the MP algorithm to the MR imaging to reduce imaging time. Inner products of residual signals and selected waveforms in the MP algorithm are derived from the MR signals by excitation of RF pulses which are fourier transforms of selected waveforms. Results from computer simulations demonstrate that the imaging time is reduced by using the MP algorithm and further a progressive reconstruction can be achieved.

  • PDF