• Title/Summary/Keyword: rank defects

Search Result 18, Processing Time 0.019 seconds

The correlation of bone probing, radiographic and histometric measurements (골탐침과 방사선학적 및 조직학적 계측의 상관관계)

  • Hwang, Sung-Joon;Kim, Chang-Sung;Lee, Doug-Youn;Lee, Yong-Keun;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.4
    • /
    • pp.615-624
    • /
    • 2003
  • The most accurate method to assess bone level is the histometric measurement. However it causes discomfort in patients and damage to the regenerated tissues. in the present study, we used 4 type regenerative therapies, The present study evaluated the clinical reliability and accuracy of bone probing measurements and radiographic bone level in the assessment of bone level by comparing those results with histometric confirmed bone level. Twentyfour(24) intrabony defects(4${\times}$4mm 1-wall intrabony defects) were surgically created in the mandibular second and fourth premolars of 6 beagle dogs. The control group underwent a conventional flap operation. Experimental group I was treated with calcium phosphate glass only, and while experimental group 2 was treated with GTR and experimental group 3 was treated with calcium phosphate glass and GTR. The subjects were sacrificed 8 weeks after the operation and a bone probing measurements, radiographic measurement and histometric measurement was performed. The correlation between bone probing measurements(BP) and histometric measurement(HL), and radiographic measurement(RL) and histometric measurement(HL) were analyzed with Spearman's rank correlation analysis and the statistical significance with respect to the type of regenerative therapies was analyzed with the Kruskal Wallis test. The coefficient of correlation to HL was 0.73 for RL and 0.90 for BP. The type of regenerative therapies had no significant effect on the difference between HL and other measurements. The results of this study suggests that bone probing measurements most closely represents actual bone level. So bone probing measurements may be a good clinical method for assessing the hone level following any type of periodontal regenerative therapies.

Modern Paper Quality Control

  • Komppa, Olavi
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.5
    • /
    • pp.72-79
    • /
    • 2000
  • On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard. Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and cockling tendency, and provides the necessary information to fine-tune the manufacturing process for optimum quality. Many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, being beyond the measurement range of the traditional instruments or resulting inconveniently long measuring time per sample. The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, non-leaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layers of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow n well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. Hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly as planned (having even small measurement error or malfunction), the process control will set the machine to operate away from the optimum, resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

  • PDF

Laser Resurfacing after Facial Free Flap Reconstruction

  • Kim, Beom-Jun;Lee, Yun-Whan;You, Hi-Jin;Hwang, Na-Hyun;Kim, Deok-Woo
    • Medical Lasers
    • /
    • v.8 no.1
    • /
    • pp.7-12
    • /
    • 2019
  • Background and Objectives Skin and soft tissue defects can be treated according to a range of strategies, such as local flap, skin graft, biological dressing, or free flap. On the other hand, free tissue transfer usually leaves a distinct scar with an inconsistency of color or hypertrophy. This problem is highlighted if the defect is located on the face, which could have devastating effects on a patient's psychosocial health. Materials and Methods The authors used an erbium : yttrium-aluminum-garnet (Er:YAG) laser to resurface the free flap skin and match the color with the surrounding facial skin. This study evaluated the effectiveness of laser skin resurfacing on the harmonious color matching of transferred flap. Patients who had undergone laser resurfacing on facial flap skin between January 2014 and December 2018 were reviewed retrospectively. An ablative 2,940-nm fractional Er:YAG laser treatment was delivered to the entire flap skin at 21 J/cm2 with the treatment end-point of pinpoint bleeding. Several months later, the clinical photographs were analyzed. The L*a*b* color co-ordinates of both the flap and surrounding normal skin were measured using Adobe Photoshop. The L*a*b* color difference (ΔE) for the scar and normal surrounding skin were calculated using the following equation: ${\Delta}E=\sqrt{({\Delta}L)^2+({\Delta}a)^2+({\Delta}b)^2}$ Results All five patients were satisfied with the more natural appearance of the flaps. The ΔE values decreased significantly from the pre-treatment mean value of 19.64 to the post-treatment mean value of 11.39 (Wilcoxon signed-rank test, p = 0.043). Conclusion Ablative laser resurfacing can improve the aesthetic outcome of free tissue transfer on the face.

Surgical Outcome of Achilles Reconstruction Using Allotendon and a Calcaneal Tunneling Technique in Patients with Chronic Achilles Rupture (동종건과 종골 터널을 이용한 만성 아킬레스건 파열 환자의 아킬레스건 재건술의 수술적 결과)

  • Gab-Lae Kim;Sung-Yup Hong;Jung Hyun Cho;Tong Young Yoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.28 no.1
    • /
    • pp.15-20
    • /
    • 2024
  • Purpose: Achilles tendon rupture is a frequently encountered ankle pathology associated with a substantial burden of intense pain and functional deficits. Chronic Achilles tendon ruptures with considerable defects pose intricate repair challenges that are often marred by complications such as re-rupture and persistent pain. Various treatment methods, including allograft transplantation, have been proposed, but the literature on this technique is limited. In this study, we propose a surgical approach utilizing allotendon transplantation and a calcaneal tunneling technique and provide clinical evaluation details. Materials and Methods: Fifteen patients with chronic Achilles tendon ruptures treated with allotendon between 2020 and 2022 were included in the study. Patients were evaluated at 1, 3, and 6 months postoperatively using Visual Analog Scale (VAS) scores and Achilles Tendon Total Rupture Scores (ATRSs). Complications were assessed postoperatively. Results: The average VAS score was 7 before surgery, 7.3 immediately after surgery, and 4.3 at 1 month, 2.5 at 3 months, and 1.3 at 6 months after surgery. Because the sample was limited to 15 individuals and distributions were non-normal, the analysis was conducted using the non-parametric Wilcoxon's signed-rank test, and statistical significance was accepted for p-values<0.05. Results showed a significant improvement in ATRS and VAS scores versus preoperative and immediate postoperative values. VAS scores showed a decreasing trend after surgery, whereas average ATRS scores increased from 14 before surgery, 33.8 at 1 month, 82.7 at 3 months, and 93.9 at 6 months. Conclusion: This study suggests that allograft transplantation using the described calcaneal tunnel technique provides an effective treatment for chronic Achilles tendon ruptures. However, extensive research and long-term clinical trials are required to validate and better understand the technique's efficacy.

Comparison of healing pattern with or without bone graft after odontogenic cyst enucleation (악골에서 발생한 치성 낭종제거 후 골이식 여부에 따른 치유속도와 양상 비교)

  • Baek, Chae-Hwan;Park, Joon-Hyung;Kim, Gun-Jong;Hong, Jong-Rak;Kim, Chang-Soo;Paeng, Jun-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.6
    • /
    • pp.515-519
    • /
    • 2010
  • Introduction: Bone defects in the jaw are frequently observed after odontogenic cyst enucleation. The success of bone healing appears to be related to the size of the bone defect, the anatomical location, the patient's age and other parameters. The use of bone grafting material is dependent on the operator's preference. No evidence-based definite treatment protocol has been established. This study evaluated the effect of a bone graft into the defect after odontogenic cyst enucleation. Materials and Methods: A total of 55 patients, who had been treated for an odontogenic cyst with cyst enucleation from 2000 to 2009 at the department of Oral and Maxillofacial Surgery, Samsung Medical Center, were included in this study. Patients who were followed-up for more than 1 year were included. Two groups were defined according to the bone graft (with or without a bone graft) after cyst enucleation. The differences in the healing periods and patterns of bone healing were compared clinically and radiologically. The postoperative 1 year radiographs were analyzed for bone healing and density. Statistical analysis was performed using a Pearson chi square test and Wilcoxon rank-sum test. Results: More infection signs were observed in the bone graft group than in the other group, but there was no statistically significant difference. Radiographically, there was also no significant difference in the size of the radiolucent lesions between the two groups. Conclusion: There was no significant difference in healing between the groups with a bone graft and without bone graft after cyst enucleation.

Necessity of Quality Control for Aviation Fuel(Jet A-1) to Secure Aviation Safety (항공안전 확보를 위한 항공유(Jet A-1) 품질관리 필요성)

  • Junbeom Heo;Yumi Kang;Heejin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.2
    • /
    • pp.194-199
    • /
    • 2024
  • Accidents due to aircraft fuel defects rank in the top 13 of the 34 accident types described by CAST-ICAO Common Taxonomy Team(CICTT). Aircraft accidents occur because of the inflow of moisture or pollutants depending on the distribution process and storage environment. To confirm the change in physical properties of the aircraft oil stored for a long time, we stored JET A-1 aircraft oil in a metal can to observe the change after six months. We confirmed that the aircraft oil stored for a long time satisfied the quality standards, and the stability of the fuel oil was high. However, in scenarios in which aircraft oil is stored separately on ships, onshore storage facilities, oil fields, etc., owing to the nature of missions, such as in marine police aircraft, the inflow of moisture or pollutants may likely occur due to changes in the internal and external environment. In addition, pollutants can be analyzed using existing tests and distillation properties, but for moisture, domestic and international standards and domestic laws determine the moisture separation ability of aircraft oil through the water separation index, but the moisture content is not analyzed. Therefore, aviation safety must be secured by adding quality control standards for moisture content and performing revisions to uniformize domestic and international standards and laws.

Modern Paper Quality Control

  • Olavi Komppa
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.16-23
    • /
    • 2000
  • The increasing functional needs of top-quality printing papers and packaging paperboards, and especially the rapid developments in electronic printing processes and various computer printers during past few years, set new targets and requirements for modern paper quality. Most of these paper grades of today have relatively high filler content, are moderately or heavily calendered , and have many coating layers for the best appearance and performance. In practice, this means that many of the traditional quality assurance methods, mostly designed to measure papers made of pure. native pulp only, can not reliably (or at all) be used to analyze or rank the quality of modern papers. Hence, introduction of new measurement techniques is necessary to assure and further develop the paper quality today and in the future. Paper formation , i.e. small scale (millimeter scale) variation of basis weight, is the most important quality parameter of paper-making due to its influence on practically all the other quality properties of paper. The ideal paper would be completely uniform so that the basis weight of each small point (area) measured would be the same. In practice, of course, this is not possible because there always exists relatively large local variations in paper. However, these small scale basis weight variations are the major reason for many other quality problems, including calender blacking uneven coating result, uneven printing result, etc. The traditionally used visual inspection or optical measurement of the paper does not give us a reliable understanding of the material variations in the paper because in modern paper making process the optical behavior of paper is strongly affected by using e.g. fillers, dye or coating colors. Futhermore, the opacity (optical density) of the paper is changed at different process stages like wet pressing and calendering. The greatest advantage of using beta transmission method to measure paper formation is that it can be very reliably calibrated to measure true basis weight variation of all kinds of paper and board, independently on sample basis weight or paper grade. This gives us the possibility to measure, compare and judge papers made of different raw materials, different color, or even to measure heavily calendered, coated or printed papers. Scientific research of paper physics has shown that the orientation of the top layer (paper surface) fibers of the sheet paly the key role in paper curling and cockling , causing the typical practical problems (paper jam) with modern fax and copy machines, electronic printing , etc. On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard . Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and coclking tendency, and provides the necessary information to finetune, the manufacturing process for optimum quality. many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, bing beyond the measurement range of the traditional instruments or resulting invonveniently long measuring time per sample . The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, nonleaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layer of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow in well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings ! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly ass planned (having even small measurement error or malfunction ), the process control will set the machine to operate away from the optimum , resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

Stress/Rest Tc-99m-MIBI SPECT in Comparison with Rest/Stress Rubidium-82 PET (휴식/부하 심근 Rubidium-82 양전자단층촬영과 부하/휴식 심근 Tc-99m-MIBI 단일광자단층촬영의 비교)

  • Lee, D.S.;Kang, K.W.;Lee, K.H.;Jeong, J.M.;Kwark, C.;Chung, J.K.;Lee, M.C.;Seo, J.D.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.31-40
    • /
    • 1995
  • We compared stress/rest myocardial Tc-99m-MIBl tomographic image findings with rest/stress rubidium-82 tomographic images. In 23 patients with coronary artery disease (12 of them received bypass grafts before) and 6 normal subjects, rest rubidium PET study was performed : rubidium-82 and Tc-99m-MIBI were injected simultaneously to each patient after dipyridamole stress for rubidium PET and MIBI SPECT; and rest MIBI SPECT was performed 4 hours thereafter. We scored segmental decrease of rubidium or MIBI uptakes into 5 grades for 29 segments from 3 short-axis, vertical and horizontal slices. Scores were summed for each major arterial territory. When more score than two grade-2's or one grade-3 was considered as the cue for significant stenosis for major arterial territories, 67% of 46 stenosed arteries were found with MIBI studies and 78% of them by rubidium studies. Fourteen among 28 grafted arterial territories of 12 post-CABG patients were found normal with both rubidium and MIBI. Segmental scores were concordant between rubidium and MIBI in 72% of 709 stress segments and in 80% of 825 rest segments. Stress rubidium segmental scores were less than stress MIBI scores in 9%, so were rest rubidium scores. Stress rubidium scores were more than stress MIBI scores in 20% of segments, and rest rubidium segmental scores were more than rest MIBl scores in 11%. Rank correlations (Spearman's rho's more than 0.7(stress) and 0.5(rest), slopes (MIBI/rubidium) around 0.7(stress) and 0.9 (rest)) suggested deeper and wider defects in stress with rubidium. Slope over 1 (MIBI/rubidium) with LAD segemental scores at rest and 7 territories which had much larger score with MIBI revealed exaggeration of rest defects with rest MIBI in same-day stress/rest study. Difference scores (stress-rest for each territory) suggesting Ischemia were larger with rubidium (slope of MIBI/rubidium around 0.45). As has been implied by animal or separate-day-human studies, these segmental analyses with simultaneous examination in patients told that rubidium PET flow studies disclose ischemia more often than MIBI studies and that rest MIBI studies in same-day stress/rest-sequence gave a little larger rest defect than they would have shown.

  • PDF