• Title/Summary/Keyword: range-Doppler

Search Result 279, Processing Time 0.021 seconds

A Study on Spectrum Moment Estimation in an Acoustic Doppler Current Profiler (ADCP에서의 스펙트럼 모멘트 추정에 관한 연구)

  • Lee, Jonggil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.8
    • /
    • pp.1790-1795
    • /
    • 2013
  • The current velocity and turbulence information in each range cell can be obtained from the first and second Doppler spectrum moment estimates. However, the very widely used correlation method often called as the pulse-pair method has the inherent restrictions under the highly turbulent conditions since it does not satisfy the assumptions that the return Doppler spectrum should be symmetric and have a single peak value. Therefore, in this paper, the quality of pulse-pair estimates were compared with that of FFT estimates for problem analysis using various shapes of simulated Doppler spectra. It can be known that the pulse-pair method often yields meaningless results if the received signals are severely biased or multi-peak Doppler spectra in the Doppler frequency domain.

Improvements of Pulse Doppler Gap Filling Algorithms for Portable Medical Ultrasound Imaging System (휴대용 초음파진단기를 위한 펄스 도플러 갭 필링 알고리즘의 개선)

  • Bae, MooHo;An, Hyung-Jun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.8
    • /
    • pp.580-589
    • /
    • 2012
  • In this paper, we studied on Doppler gap-filling algorithms suitable for a portable or low-cost medical ultrasound imaging system, and as a result, found out algorithms based on mirroring or autoregressive model. Moreover, controlling the computational demand in the proper range, we improved the performances of these algorithms by solving their problems. Effectiveness of these modified algorithms is verified by computer simulations and experiments which used artificially generated Doppler signals and Doppler data acquired from human body through an actual ultrasound system.

GPS Pull-In Search Using Reverse Directional Finite Rate of Innovation (FRI)

  • Kong, Seung-Hyun;Yoo, Kyungwoo
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.3 no.3
    • /
    • pp.107-116
    • /
    • 2014
  • When an incoming Global Positioning System (GPS) signal is acquired, pull-in search performs a finer search of the Doppler frequency of the incoming signal so that phase lock loop can be quickly stabilized and the receiver can produce an accurate pseudo-range measurement. However, increasing the accuracy of the Doppler frequency estimation often involves a higher computational cost for weaker GPS signals, which delays the position fix. In this paper, we show that the Doppler frequency detectable by a long coherent auto-correlation can be accurately estimated using a complex-weighted sum of consecutive short coherent auto-correlation outputs with a different Doppler frequency hypothesis, and by exploiting this we propose a noise resistant, low-cost and highly accurate Doppler frequency and phase estimation technique based on a reverse directional application of the finite rate of innovation (FRI) technique. We provide a performance and computational complexity analysis to show the feasibility of the proposed technique and compare the performance to conventional techniques using numerous Monte Carlo simulations.

Efficient Doppler Spectrum Estimation in Radar Systems (레이다 시스템에서의 효율적인 도플러 스펙트럼 추정)

  • Lee, Jonggil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.605-608
    • /
    • 2009
  • It is necessary to estimate the Doppler spectrum for each range cell for the extraction of useful information from the return echoes in radar systems used for the remote sending purpose. However, The conventional spectrum estimation method, FFT(Fast Fourier Transform), called the Doppler filter bank, causes the frequency resolution problem if the dwell time is relatively short. This short acquisition time also spreads the side lobe levels of return echoes further, resulting in difficulties for the discrimination of weak target signals included in relatively strong target echoes. Therefore, in this paper, the efficient Doppler spectrum estimation methods are compared and investigated through the parameter spectrum estimation in the time domain to overcome these problems.

  • PDF

Multi-Mode Radar System Model Design for Helicopter (헬기탑재 다중모드 레이다 시스템 모델 설계)

  • Kwag, Young-Kil;Bae, Jae-Hoon
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.208-212
    • /
    • 2003
  • An airborne radar is an essential aviation electronic system of the helicopter to perform various missions in all-weather environments. This paper presents the conceptual design results of the multi-mode pulsed Doppler radar system testbed model for helicopter. Due to the inherent flight nature of the hovering vehicle which is flying in low-altitude and low speed, as well as rapid maneuvering, the moving clutters from the platform should be suppressed by using a special MTD (Moving Target Detector) processing. For the multi-mode radar system model design, the flight parameters of the moving helicopter platform were assumed: altitude of 3 Km, average cruising velocity of 150knots. The multi-mode operation capability was applied such as short-range, medium-range, and long-range depending on the mission of the vehicle. The nominal detection ranges is 30 Km for the testbed experimental model, but can be expanded up to 75 Km for the long range weather mode. The detection probability of each mode is also compared in terms of the signal-to noise ratio of each mode, and the designed radar system specifications ate provided as a design results.

  • PDF

A study on the features of resolution of robust active sonar pulses from the reverberation environment (잔향 환경에 강인한 능동 소나 펄스의 분해능 특성 연구)

  • Jeong, Eui Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.2
    • /
    • pp.158-165
    • /
    • 2016
  • Many researches for improving detection performance in the reverberation environment have been conducted in active sonar systems. Especially the type of active pulse makes an impact on the detection performance in the reverberation environment. Thus, this paper describes the detection performance of PTFM (Pulse Trains of Frequency Modulated waveform), Costas, and Geometric Comb pulses which are known for their outstanding performance against the reverberation. Sea trial data of those pulses was analyzed and it was figured out that the range resolution of PTFM pulse was deteriorated by its sub-pulses. Costas pulse showed performance degradations of the doppler resolution by multipath signals. Geometric Comb pulse showed the best doppler resolution.

Optimal Radar Pulse Compression Processing Algorithm and the Resulting Optimal Codes for Pulse Compressed Signals (레이더 펄스 압축 신호의 최적 탐색 알고리즘 개발 및 최적 코드에 관한 연구)

  • 김효준;이명수;김영기;송문호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.6B
    • /
    • pp.1100-1105
    • /
    • 2000
  • The most widely used radar pulse compression technique is correlation processing using Barker code. This technique enhances detection sensitivity but, unfortunately, suffers from the addition of range sidelobes which sometimes will degrade the performance of radar systems. In this paper, our proposed optimal algorithm eliminates the sidelobes at the cost of additional processing and is evaluated in the presence of Doppler shift. We then propose optimal codes with regard to the proposed algorithm and the performance is compared against the traditional correlation processing with Barker codes. The proposed processing using optimal codes will be shown to be superior over the traditional processing in the presence of Doppler shift.

  • PDF

3D localization of internal noise source based on Doppler effect (도플러 효과를 기반으로한 내부 소음원의 3차원 위치 추정)

  • Bae, Jung-Ho;Seong, Woojae;Lee, Keunhwa
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.4
    • /
    • pp.310-318
    • /
    • 2016
  • This study deals with a method to localize a noise source occuring in a marine vehicle in a 3D environment. Even when access to the noise source is limited for a marine vehicle, such as a ship or a submarine in operation, the signal received on a hydrophone located elsewhere contains Doppler effected noise by moving relatively. This study suggests noise localization algorithm in 3D based on Doppler effect by moving marine vehicle. Using a known source mounted on the vehicle, the noise source was estimated by reducing the range of Doppler center and closest point of approach via the least square method. The algorithm was verified through various simulations and it was shown that the noise could be localized in 3D based on Doppler effect by employing two fixed hydrophones located at the vehicle's exterior points and a known reference signal generator located somewhere on the vehicle.

Volumetric Blood Velocity Measurement on Multigate Pulsed Doppler System based on the Single Channel RF Sampling using the Optimized Sampling Factor (최적화된 샘플링 인수를 갖는 단일 채널 RF 샘플링 방식의 다중점 펄스 도플러 시스템을 사용한 혈류 속도분포 측정)

  • 임춘성;민경선
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.143-152
    • /
    • 1998
  • In this paper, we present the performances of a Doppler system using single channel RF(Radio Frequency) sampling. This technique consists of undersampling the ultrasonic blood backscattered RF signal on a single channel. Conventional undersampling method in Doppler imaging system have to use a minimum of two identical parallel demodulation channels to reconstruct the multigate analytic Doppler signal. However, this system suffers from hardware complexity and problem of unbalance(gain and phase) between the channels. In order to reduce these problems, we have realized a multigate pulsed Doppler system using undersampling on a single channel, It requires sampling frequency at $4f_o$(where $f_o$ is the center frequency of the transducer) and 12bits A/D converter. The proposed " single-Channel RF Sampling" method aims to decrease the required sampling frequency proportionally to $4f_o$/(2k+1). To show the influence of the factor k on the measurements, we have compared the velocity profiles obtained in vitro and in vivo for different intersequence delays time (k=0 to 10). We have used a 4MHz center frequency transducer and a Phantom Doppler system with a laminar stationary flow. The axial and volumetric velocity profiles in the vessel have been computed according to factor k and have been compared. The influence of the angle between the ultrasonic beam and the flow axis direction, and the fluid viscosity on the velocity profiles obtained for different values of k factor is presented. For experiment in vivo on the carotid, we have used a data acquisition system with a sampling frequency of 20MHz and a dynamic range of 12bits. We have compared the axial velocity profiles in systole and diastole phase obtained for single channel RF sampling factor.ng factor.

  • PDF

A Study of Noncontact Heartbeat and Respiration Detection Using the Doppler Radar (도플러 레이더를 이용한 비접촉 방식의 심박 및 호흡 검출에 관한 연구)

  • Shin, Jae-Yeon;Cho, Sung-Pil;Jang, Byung-Jun;Park, Ho-Dong;Lee, Yun-Soo;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • In this paper, a 2.4 GHz doppler radar system consisting of a doppler radar sensor and a baseband module were designed to detect heart beat and respiration signal without direct skin contact. The doppler radar system emits RF signal of 2.4 GHz toward human chest, and then detects phase modulation of the reflected signal so as to investigate cardiopulmonary activities. The heartbeat and respiration signals acquired from I/Q channels of the doppler radar system are applied to the pre-processing circuit, the amplification circuit, and the offset circuit of the baseband module. The designed system was tested on mouse, rabbit and mankind, which have different range of heart rates and respiration signals, to evaluate detection accuracy of the system. ECG acquisition system and respiration transducer were used to generate the reference signal. In our experiments, a performance of detection were found to be high in the case that the subject stays still. In this paper, we confirmed that non-contact heart beat and respiration detection using the doppler radar has the possibility and limitation according to distance, cardiopulmonary activities, range of heart rates and respiration.