• Title/Summary/Keyword: range scaling

Search Result 209, Processing Time 0.025 seconds

An Adaptive Maximum Power Point Tracking Scheme Based on a Variable Scaling Factor for Photovoltaic Systems (태양광 시스템을 위한 가변 조정계수 기반의 적응형 MPPT 제어 기법)

  • Lee, Kui-Jun;Kim, Rae-Young;Hyun, Dong-Seok;Lim, Chun-Ho;Kim, Woo-Chull
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.423-430
    • /
    • 2012
  • An adaptive maximum power point tracking (MPPT) scheme employing a variable scaling factor is presented. A MPPT control loop was constructed analytically and the magnitude variation in the MPPT loop gain according to the operating point of the PV array was identified due to the nonlinear characteristics of the PV array output. To make the crossover frequency of the MPPT loop gain consistent, the variable scaling factor was determined using an approximate curve-fitted polynomial equation about linear expression of the error. Therefore, a desirable dynamic response and the stability of the MPPT scheme were maintained across the entire MPPT voltage range. The simulation and experimental results obtained from a 3 KW rated prototype demonstrated the effectiveness of the proposed MPPT scheme.

Range-Scaled 14b 30 MS/s Pipeline-SAR Composite ADC for High-Performance CMOS Image Sensors

  • Park, Jun-Sang;Jeong, Jong-Min;An, Tai-Ji;Ahn, Gil-Cho;Lee, Seung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.1
    • /
    • pp.70-79
    • /
    • 2016
  • This paper proposes a low-power range-scaled 14b 30 MS/s pipeline-SAR composite ADC for high-performance CIS applications. The SAR ADC is employed in the first stage to alleviate a sampling-time mismatch as observed in the conventional SHA-free architecture. A range-scaling technique processes a wide input range of 3.0VP-P without thick-gate-oxide transistors under a 1.8 V supply voltage. The first- and second-stage MDACs share a single amplifier to reduce power consumption and chip area. Moreover, two separate reference voltage drivers for the first-stage SAR ADC and the remaining pipeline stages reduce a reference voltage disturbance caused by the high-speed switching noise from the SAR ADC. The measured DNL and INL of the prototype ADC in a $0.18{\mu}m$ CMOS are within 0.88 LSB and 3.28 LSB, respectively. The ADC shows a maximum SNDR of 65.4 dB and SFDR of 78.9 dB at 30 MS/s, respectively. The ADC with an active die area of $1.43mm^2$ consumes 20.5 mW at a 1.8 V supply voltage and 30 MS/s, which corresponds to a figure-of-merit (FOM) of 0.45 pJ/conversion-step.

Repercussions to the musculoskeletal system of the Upper Limb caused by scaling training exercise (치위생학과 스케일링 실습수업이 상지 근골격계에 미치는 영향)

  • Ro, Hyo-Lyun;Yoo, Ja-Hea;Lee, Min-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.3
    • /
    • pp.45-51
    • /
    • 2008
  • Purpose: We evaluated the physical stress and pain to the musculoskeletal system of a dental practitioner when engaging in a dental scaling training exercise to prevent the development of musculoskeletal injuries. Methods: The 18 female (average age: 21$\pm$1 years) subjects were voluntarily picked from a group of juniors who have completed a one-and-a-half year training course that includes training exercises on the dentiform and on live subjects (other trainees). The test is done by measuring pain, activity, grip strength, and finger dexterity for each subject's hand and wrist. Before the test all subjects were confirmed to be right-handed and were informed of the study and its objective. Measuring was done before and after each subject performed dental scaling for one hour using the scaler and the curet. Results: Pain levels increased for both hand and shoulders, but hand pain was often greater than shoulder pain. Grip strength significantly declined in the right hand but not the left. For joint mobility, the flexion and the extension for the shoulder joint did not change; but the range of motion for both wrist joints significantly increased. For the dexterity test, both hands showed increased dexterity after the exercise. Conclusion: Dental scaling can affect the shoulders and wrists/hands. Therefore, a musculoskeletal injury prevention program for dental practitioners, which may include encouraging them to assume correct body posture when at work, must be sought. This study evaluated only the shoulders, wrists, and hands; but future studies should include areas such as the cervical area, the back, and the lower limbs.

  • PDF

Evaluation of Ground Motion Modification Methodologies for Seismic Structural Damage (지진 구조 손상도 예측을 위한 지반 운동 수정법 평가)

  • Heo, YeongAe
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.112-118
    • /
    • 2013
  • The selection of appropriate ground motions and reasonable modification are becoming increasingly critical in reliable prediction on seismic performance of structures. A widely used amplitude scaling approach is not sufficient for robust structural evaluation considering a site specific seismic hazard because only one spectral value is matched to the design spectrum typically at the structural fundamental period. Hence alternative approaches for ground motion selection and modifications have been suggested. However, there is no means to evaluate such methodologies yet. In this study, it is focused to describe the main questions resided in the amplitude scaling approach and to propose a regression model for structural damage as point of comparison. Spectrum compatible approach whose resulting spectrum matches the design spectrum at the entire range of the structural period is considered as alternative to be compared to the amplitude scaling approach. The design spectrum is generated according to ASCE7-05.

Development of a decision scaling framework for drought vulnerability assessment of dam operation under climate change (Decision Scaling 기반 댐 운영 기후변화 가뭄 취약성 평가)

  • Kim, Jiheun;Seo, Seung Beom;Cho, Jaepil
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.4
    • /
    • pp.273-284
    • /
    • 2023
  • Water supply is continuously suffering from frequent droughts under climate change, and such extreme events are expected to become more frequent due to climate change. In this study, the decision scaling method was introduced to evaluate the drought vulnerability under future climate change in a wider range. As a result, the water supply reliability of the Boryeong Dam ranged from 95.80% to 98.13% to the condition of the aqueduct which was constructed at the Boryeong Dam. Furthermore, the Boryeong Dam was discovered to be vulnerable under climate change scenarios. Hence, genetic algorithm-based hedging rules were developed to evaluate the reduction effect of drought vulnerability. Moreover, three demand scenarios (high, standard, and low demand) were also considered to reflect the future socio-economic change in the Boryeong Dam. By analyzing quantitative reliability and the probability of extreme drought occurrence under 5% of the water storage rate, all hedging rules demonstrated that they were superior in preparing for extreme drought under low-demand scenarios.

Recorder with automatic scaling function

  • Tomita, Takehiko;Tohara, Masahiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.891-895
    • /
    • 1988
  • We discuss what kind of scale is suitable for analog signal recording paper from the viewpoint of human engineering. We show a method for automatically generating a suitable scale from the higher and lower limits of the recording range.

  • PDF

Multi-Scaling Models of TCP/IP and Sub-Frame VBR Video Traffic

  • Erramilli, Ashok;Narayan, Onuttom;Neidhardt, Arnold;Saniee, Iraj
    • Journal of Communications and Networks
    • /
    • v.3 no.4
    • /
    • pp.383-395
    • /
    • 2001
  • Recent measurement and simulation studies have revealed that wide area network traffic displays complex statistical characteristics-possibly multifractal scaling-on fine timescales, in addition to the well-known properly of self-similar scaling on coarser timescales. In this paper we investigate the performance and network engineering significance of these fine timescale features using measured TCP anti MPEG2 video traces, queueing simulations and analytical arguments. We demonstrate that the fine timescale features can affect performance substantially at low and intermediate utilizations, while the longer timescale self-similarity is important at intermediate and high utilizations. We relate the fine timescale structure in the measured TCP traces to flow controls, and show that UDP traffic-which is not flow controlled-lacks such fine timescale structure. Likewise we relate the fine timescale structure in video MPEG2 traces to sub-frame encoding. We show that it is possibly to construct a relatively parsimonious multi-fractal cascade model of fine timescale features that matches the queueing performance of both the TCP and video traces. We outline an analytical method ta estimate performance for traffic that is self-similar on coarse timescales and multi-fractal on fine timescales, and show that the engineering problem of setting safe operating points for planning or admission controls can be significantly influenced by fine timescale fluctuations in network traffic. The work reported here can be used to model the relevant characteristics of wide area traffic across a full range of engineering timescales, and can be the basis of more accurate network performance analysis and engineering.

  • PDF

Application of Detrended Fluctuation Analysis of Electroencephalography during Sleep Onset Period (수면발생과정의 뇌파를 대상으로한 탈경향변동분석의 적용)

  • Park, Doo-Heum;Shin, Chul-Jin
    • Korean Journal of Biological Psychiatry
    • /
    • v.19 no.1
    • /
    • pp.65-69
    • /
    • 2012
  • Objectives : Much is still unknown about the neurophysiological mechanisms or dynamics of the sleep onset process. Detrended fluctuation analysis (DFA) is a new tool for the analysis of electroencephalography (EEG) that may give us additional information about electrophysiological changes. The purpose of this study is to analyze long-range correlations of electroencephalographic signals by DFA and their changes in the sleep onset process. Methods : Thirty channel EEG was recorded in 61 healthy subjects (male:female=34:27, age=$27.2{\pm}3.0$ years). The scaling exponents, alpha, were calculated by DFA and compared between four kinds of 30s sleep-wakefulness states such as wakefulness, transition period, early sleep, and late sleep (stage 1). These four states were selected by the distribution of alpha and theta waves in O1 and O2 electrodes. Results : The scaling exponents, alpha, were significantly different in the four states during sleep onset periods, and also varied with the thirty leads. The interaction between the sleep states and the leads was significant. The means (${\pm}$ standard deviation) of alphas for the states were 0.94 (${\pm}0.12$), 0.98 (${\pm}0.12$), 1.10 (${\pm}0.10$), 1.07 (${\pm}0.07$) in the wakefulness, transitional period, early sleep and late sleep state respectively. The mean alpha of anterior fifteen leads was greater than that of posterior fifteen leads, and the two regions showed the different pattern of changes of the alpha during the sleep onset periods. Conclusions : The characteristic findings in the sleep onset period were the increasing pattern of scaling exponent of DFA, and the pattern was slightly but significantly different between fronto-temporal and parieto-occipital regions. It suggests that the long-range correlations of EEG have a tendency of increasing from wakefulness to early sleep, but anterior and posterior brain regions have different dynamical process. DFA, one of the nonlinear analytical methods for time series, may be a useful tool for the investigation of the sleep onset period.

Analysis of Blast Wave of Explosives by the Scaling Law (축척법에 의한 화약 폭풍과 분석)

  • Park, Jung-Su;Kim, Sung-Ho;Lee, Keun-Deuk;Lee, Jai-Min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.4 s.23
    • /
    • pp.120-129
    • /
    • 2005
  • To analyze a blast effect of developed explosives, three different kinds of aluminized tastable explosives and melted cast explosive TNT were used. Conventional explosive TNT was used as a reference. Each tested explosive charge of 340mm diameter spherical type was initiated at the charge center with DXD-65(${\sim}750g$) booster and RP-87 EBW detonator. Thirteen piezo type pressure sensors were located at a range from 4 to 50m away from the charge. From the blast wave profiles, we calculated a peak blast pressure and impulse of the explosion. The calculated pressures and in pulses were converted to TNT Equivalent Weight(TEW) factor by the scaling ]aw method. The average TEW factors based on the blast pressure of TX-01, TX-02, TX-03, TX-04 were 1.298, 1.05, 1.266, 1.274 and the average TEW factors based on impulse were 1.504, 1.686, 1.640, 1.679. From the results, we concluded that TEW factors based on blast pressure and based on impulse of aluminized explosives were superior to TNT. This results are owing to the high contents of aluminum in formulations.

A study on the bottom oxide scaling for dielectric in stacked capacitor using L/L vacuum system (L/L 진공시스템을 이용한 적층캐패시터의 하층산화막 박막화에 대한 연구)

  • 정양희;김명규
    • Electrical & Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.476-482
    • /
    • 1996
  • The multi-dielectric layer SiO$_{2}$/Si$_{3}$N$_{4}$/SiO$_{2}$(ONO) is used to improve electrical capacitance and to scale down the memory device. In this paper, improvement of the capacitance by reducing the bottom oxide thickness in the nitride deposition with load lock(L/L) vacuum system is studied. Bottom oxide thickness under the nitride layer is measured by ellipsometer both in L/L and non-L/L systems. Both results are in the range of 3-10.angs. and 10-15.angs., respectively, independent of the nitride and top oxide thickness. Effective thickness and cell capacitance for SONOS capacitor are in the range of 50-52.angs. and 35-37fF respectively in the case of nitride 70.angs. in L/L vacuum system. Compared with non-L/L system, the bottom oxide thickness in the case of L/L system decreases while cell capacitance increases about 4 fF. The results obtained in this study are also applicable to ONO scaling in the thin bottom oxide region of memory stacked capacitor.

  • PDF