• Title/Summary/Keyword: range of motion

Search Result 3,032, Processing Time 0.032 seconds

A Comparative Study of Range of Motion With or Without Distal Interphalangeal Joint Fixation in Replantation of the Amputated Fingertips (수지 첨부 절단창의 재접합술 시 원위지 관절 고정과 운동 범위의 관계)

  • Han, Seung-Kyu;Roh, Si-Young;Kim, Jin-Soo;Lee, Dong-Chul;Ki, Sae-Hwi;Yang, Jae-Won
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.1
    • /
    • pp.18-25
    • /
    • 2011
  • Purpose: In the process of replantation of the amputated fingertips, the primary concern was given to survival of the amputees, while the functional aspect of digits after the surgery has been easily neglected. Although an internal fixation with a K-wire is often a part of replantation of the amputated fingertips, little consideration had been given to the study of relationship between distal interphalangeal joint fixation and post operative range of motion. A comparative study in relation to post operative range of motion was done on two different groups, one group with K-wire insertion and the other group without a K-wire insertion at the distal interphalangeal joint. Materials and Methods: The study was done on the cases of a single digit amputation conducted at our institute (the age in the range of 10 to 60) in about four-year of time span from March of 2005 to March of 2009. The cases with a thumb replantation, osteomyelitis or articular surface injury have been excluded from this study. The cases of both head and shaft fracture, except the insertion site of tendon, of distal phalanx of internal fixation with a single K-wire were reviewed for this study. A group of 24 cases without distal interphalangeal joint fixation in comparison to a group of 22 cases with distal interphalangeal joint fixation was reviewed to assess the postoperative range of motion at distal interphalangeal joint on the 6th week after the surgery. And, on the 30th month after the surgery, a group of 10 cases without distal interphalangeal joint fixation in comparison to a group of 10 cases with joint fixation was reviewed. A K-wire was removed in about 5 weeks after the fracture was reunited under the radiographic image, immediately followed by a physical therapy. Result: The active range of motion for a group without interphalangeal joint fixation was measured $49.0^{\circ}$ on average, while $28.6^{\circ}$ was measured for a group with interphalengeal fixation on the 6th week after the surgery. On the 30th month after the surgery, the active range of motion was measured $52.0^{\circ}$ and $55.0^{\circ}$ on average for a group without and with interphalangeal fixation respectively. Conclusion: In the process of replantation of the amputated fingertips, short-term(on the 6th week) improvement of postoperative active motion of range can be expected in the cases without distal interphalangeal fixation in comparison to the cases of interphalangeal joint fixation with a K-wire. However, there seems to be no difference on motion of range in a long-term (on the 30th month) follow up period.

  • PDF

The Reliability and Validity of Hip Range of Motion Measurement using a Smart phone Operative Patient (엉덩관절 수술 환자에서 스마트폰을 이용한 관절가동범위 측정의 신뢰도 및 타당도 연구)

  • Park, Sun-Wook;Kim, Myoung-Soo;Bae, Hyo-Sun;Cha, Yong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.2
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE: The aims of this study were to assess the intra-tester and inter-tester reliability and validity of hip range of motion using a smart phone in hip operative patients. METHODS: Twenty-five patients (eight total hip arthroplasty and seventeen femur neck fracture) participated in this study. The range of motions in active and passive hip flexion, abduction and external rotation were measured with a goniometer and smart phone over two times by two observers. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC2,1). The validity was measured by Pearson's correlation coefficient RESULTS: The intra-observer reliability was good in all measured items (ICC>0.78). The inter-observer reliability was high with ICC (>0.90). All correlation coefficients of smart phone and goniometer was greater than 0.85 and showed a significant positive correlation (p<0.01). CONCLUSION: The range of motion measurement with a smart phone showed acceptable reliability. Therefore, it could be convenient and have economical benefits to measure the range of motion of the hip joint using a smart phone.

Effects of Skin Mobilization on Pain and Joint Range Improvement in Patients with Axillary Web Syndrome: A Single Case Report

  • Choi, Suhong;Lee, Sangyeol
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.2
    • /
    • pp.112-115
    • /
    • 2021
  • Objective: This study was conducted to apply skin mobilization to patients with Axillary web syndrome following breast cancer resection and to see the resulting changes in pain and joint range of motion. Design: Single case study,pre-post comparison. Methods: The subject was a female patient in her 40s who performed a mastectomy after being diagnosed with breast cancer, and then complained of uncomfortable pain from the shoulder joint to the axilla and limited range of motion. To implement a skin mobilization, the palms were adhered to the inner half of the arm, the arms were raised to a pain-free extent, and skin mobilization was performed. The skin was pulled in the direction of axilla and kept for 5 seconds 10 times for a total of 2 sets. Immediate changes in range of motion and pain were identified. Results: Following skin mobilization, there was an immediate increase in range of motion (pre 116°, post 140°) and a decrease in pain (NRS pre 5, post 2). And also uncomfortable pain, which is hard to define in words, also seems to have improved. Conclusions: Skin mobilization, which considers skin mobility for patients with Axillary web syndrome, can be considered for improving range of motion and restoring function in patients with pain due to fibrous bands around veins and lymphatic vessels, and is recommended as a new intervention method not used as a conventional treatment.

Measurement on range of two degrees of freedom motion for analytic generation of workspace (작업영역의 해석적 생성을 위한 2자유도 동작의 동작범위 측정)

  • 기도형
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.15-24
    • /
    • 1996
  • To generate workspace analytically using the robot kinematics, data on range of human joints motion, especially range of two degrees of freedom motion, are needed. However, these data have not been investigated up to now. Therefore, in this research, we are to investigate an interaction effect of motions with two degrees of freedom occurred simultaneously at the shoulder, virtual hip(L5/S1) and hip joints, respectively, for 47 young male students. When motion with two degrees of freedom occurred at a joint such as shoulder, virtual hip and hip joints, it was found from the results of ANOVA that the action of a degree of freedom motion may either decrease or increase the effective functioning of the other degree of freedom motion. In other words, the shoulder flexion was decreased as the shoulder was adducted or abducted to $60^{\circ}C$TEX>or abducted from $60^{\circ}C$TEX>to maximum degree of abduction, while the shoulder flexion increased as the joint was abducted from $60^{\circ}C$TEX> to $60^{\circ}C$TEX> The flexion was decreased as the virtual hip was bent laterally at the virtual hip joint, and also did as the hip was adducted or abducted from the neutral position. It is expected that workspace can be generated more precisely based the data on the range of two degrees of joint motion measured in this study.

  • PDF

The Kinematic Comparison of Energy Walking and Normal Walking (에너지보행과 일반보행의 운동학적 비교)

  • Shin, Je-Min;Jin, Young-Wan
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.4
    • /
    • pp.61-71
    • /
    • 2006
  • The purpose of this study was to compare kinematic characteristics on the limbs at 3 different walking speed during the energy and the normal walking. Eight subjects performed energy walking and normal walking at the slow speed(65 beats/min), the normal speed(115beats/min), the fast speed(160 beats/min). The 3-d angle was calculated by vector projected with least squares solution with three-dimensional cinematography(Motion Analysis corporation). The range of motion was calculated on the trunk, shoulder, elbow, hip, knee joint. The results showed that stride length was no difference of the two walking pattern. The duration of support phase was also no difference of the two walking pattern. The range of motion of shoulder joint significantly increased in the sagittal and frontal planes, and the range of motion of elbow joint significantly increased as the energy walking. The range of motion of hip joint had no significant difference in the any planes in changing of walking speed. But the most remarkable difference of the two walking patterns revealed at the trunk. The range of flexion/extension angle had significant increasing $2.36^{\circ}$ at normal speed, and the range of the right/left flexion angle had significant increasing below $4^{\circ}$ at the 3 walking speed, and The range of rotation angle had significant increasing $7.35^{\circ}$, $9.22^{\circ}$, respectively at the normal and slow speed. But there was no significant difference of range of motion at the hip and knee joints between energy walking and normal walking.

Effects of Joint Mobilization on The Range of Motion and Pain of Patient with Chronic Low Back Pain (관절가동술이 만성요통 환자의 기동범위와 통증에 미치는 영향)

  • Lee, Young-Hwa;Kwon, Won-An;Kim, Han-Soo;Bae, Sung-Soo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.2
    • /
    • pp.113-124
    • /
    • 2007
  • Purpose : The purpose of this study was to investigate the effects of joint mobilization on the rang of motion and pain of patient with chronic low back pain. Methods : The subjects were consisted of thirty patients with chronic low back pain(19 females, 11 males ; mean aged 59.93) from 50 to 71. All subjects randomly assigned to the modalities treatment group, joint mobilization group. Modalities treatment group received hot pack used thermal therapy for 20minutes and ICT used electrical therapy for 15minutes, joint mobilization group received modalities treatment with sustained natural apophyseal glides(SNAGS) techniques of Mulligan for 10minutes per day and three times a week during 2 weeks period. Visual Analogue Scale(VAS) was used to measure subjective pain level. Remodified Schober test(RST) was used to measure range of motion of lumbar spine. All measurements of each patients were measured at pre-treatment and 2 weeks post-treatment. Results : The results of this study were summarized as follows : 1. VAS was joint mobilization group showed significantly decreased more than modalities treatment group (p<.05). 2. The lumbar flexion range of motion was joint mobilization group showed significantly decreased more than modalities treatment group(p<.05). 3. The lumbar extension range of motion was joint mobilization group showed significantly decreased more than modalities treatment group(p<.05). 4. The lumbar left lateral flexion range of motion was joint mobilization group showed significantly decreased more than modalities treatment group(p<.05). 5. The lumbar right lateral flexion range of motion was joint mobilization group showed significantly decreased more than modalities treatment group(p<.05). Conclusion : These data suggests that SNAGS of Mulligan is beneficial treatment for chronic low back pain.

  • PDF

Effects of a Taping Therapy on Shoulder Range of Motion and Pain, Physical Function and Depression of Stroke Patients with Hemiplegia (테이핑요법이 뇌졸중 편마비 환자의 견관절 운동범위와 통증, 신체기능 및 우울에 미치는 효과)

  • Kang, Seung-Ju;Kim, In-Sook
    • Korean Journal of Adult Nursing
    • /
    • v.24 no.3
    • /
    • pp.294-304
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the effects of taping therapy on the range of motion and pain of shoulders, physical functions and depression among hospitalized patients with stroke a geriatric hospital. Methods: The study design was a none equivalent control group pre-post test quasi-experimental design. The participants were 25 patients for experimental group and 25 patients for the control group. The period of this study was from March to July 2010. The twenty minute taping therapy was performed for twice a week for eight weeks. Results: The results showed that taping therapy was effective in range of motion shoulders (flexion: t=-5.81, p =.001, abduction: t=-3.69, p =.001) and pain of shoulders (rest: t=3.18, p = .003, movement: t=2.97, p =.005), grip (t=-3.22, p =.002) and balance (t=3.20, p =.002), and depression (t=3.24, p =.002). The variable of ADL (t=-1.99, p =.052) was not significant. Conclusion: The results of the taping therapy increased range of motion shoulders and grip and balance of physical functions, and decreased pain in shoulders and depression. The findings support that taping therapy can be used as a nursing intervention for stroke patients in practical nursing and communities.

Effects of Scapular Stabilization Exercise on the Range of Motion, Pain, and Function in the Shoulders of Women with Breast Cancer Surgery (견갑골 안정화 운동이 유방암 절제술을 한 여성의 견관절 가동범위, 통증 및 기능수준에 미치는 영향)

  • Nam, Soo-jin;Kang, Tae-woo
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.23 no.2
    • /
    • pp.69-74
    • /
    • 2017
  • Background: To compare the effects of scapular stabilization exercise on the range of motion, pain, and function in the shoulders of women with breast cancer surgery. Methods: Fifteen patients were performed scapular stabilizing training using dumbbells for 30 minutes daily, five times per week for 4 weeks. The range of motion, pain, and function in the shoulder were assessed. Goniometer was used for ROM of shoulder external rotation. Shoulder pain and disability index was used for pain and function of shoulder. Comparison of the pre and post intervention was calculated by a paired t-test. Results: After 4 weeks of training, range of motion, pain and function in the shoulder improved significantly in patients with breast cancer surgery (p<.05). Conclusion: These findings indicate the more favorable effects from scapular stabilization exercise in patients with breast cancer surgery.

  • PDF

The Influence of Augmented Reality based Knee Exercise in Short Period on Range of Motion and Balance - Pilot study (증강현실 기반의 단기간 무릎운동이 관절가동범위와 균형에 미치는 영향 - 예비연구)

  • Im, JongHun;Yu, JaeHo
    • Archives of Orthopedic and Sports Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2018
  • Purpose: This study investigated the effect of the augmented reality (AR)-based knee joint short period exercise program and used a motion analyzer with a 3D camera to determine the range of motion and dynamic balance and further investigate the effects of therapeutic exercise on patients. Methods: This study used AR-based motion analysis and a Y-balance test to measure the range of motion (ROM) of each joint: the hip joint and the knee joint. After the measurements, an exercise program was applied to the subjects, using the knee motion program function, and the muscles of the quadriceps femoris and the hamstring were stretched or strengthened. Results: Our results showed knee joint extension at the dominant hip joint flexion position. While there was no significant difference (p>.05) at this position, there were significant differences in the non-dominant hips, unbalanced knee joint flexion, and superior knee joint flexion (p<.05). The Y-balance test using the non-dominant leg supported by the dominant legs showed that the absolute reach was $69.70{\pm}7.06cm$ before the exercise, and the absolute reach after the exercise was $77.56{\pm}6.09cm$ (p<.05). Conclusions: There was a significant difference when the movement of the lower limbs supported the superior limbs, and a significant difference was found in the ROM when the non-dominant side supported the dominant side. Therefore, the AR-based exercise program improves the balance of the human body and the range of motion of the joints, and research that aims to improve patients abilities should continue.

Effect of the Lumbar Range of Motion and Back Pain on Kinesiotaping of Erector Spinae Muscle (척주세움근의 키네시오 테이핑이 허리가동범위와 허리통증에 미치는 영향)

  • Park, Jonghang;Kim, Yoonhwan;Lee, Jaejun
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.3 no.4
    • /
    • pp.53-59
    • /
    • 2015
  • Purpose : To retestify about the changes of the range of motion and pain from kinesiotaping the erector spinae muscle. Method : Targeted the number of 30 people with low back pain and measured lumbar range of motion and pain before kinesiotaping on the erector spinae muscle. After that, the measured value were compared and analyzed. Result : First, before and after kinesiotaping, doing skin distraction test, the changes of the skin distance within each experiment group all statistically showed meaningful differences(p<0.05). Secondly, before and after kinesiotaping and testing pain threshold, it statistically showed meaningful differences(p<0.05). Conclusion : Both two groups showed that the change of the skin distance increased and the pain averagely decreased than before taping. Therefore, kinesiotaping is considered that it affected the low back, the range of motion and pain.