• Title/Summary/Keyword: ramp

Search Result 860, Processing Time 0.026 seconds

Q-Switched Nd YAG's SHG conversion techniques for a skin diseased treatment (피부질환 치료를 위한 Q-Switched Nd:YAG의 SHG 변환기술)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.6
    • /
    • pp.1141-1149
    • /
    • 2009
  • Pulse style Nd: YAG Laser is suitable in skin remaking treatment, in compliance with the ramp continuous oscillation until of course normal takeoff, the Q-switch and mode motive takeoff the takeoff form which is various is possible and it is coming to be widely used in microsurgery and skin remaking promotion. According to therapeutic objective very it is important to control a energy density. Control of energy density the method which controls the pulse repetition rate of Laser output is mainly used. From the research which it sees pulse style Nd: It will be able to control the pulse repetition rate of YAG, the 2nd harmonic occurrence Laser (second harmonic generation: SHG) with the energy part of the light-wave which is a footnote wave number will hold and nonlinear decision it propagates and is converted by energy of the light-wave which is a footnote wave number the actual condition which and it applies the second harmonic occurrence in compliance with a secondary nonlinearity it leads and until skin deep part therapeutic possibility is the thing it will be able to observe simply.

이류체 노즐을 이용한 FPD 세정시스템 및 공정개발에 대한 연구

  • Kim, Min-Su;Kim, Hyeok-Min;Gang, Bong-Gyun;Lee, Seung-Ho;Jo, Byeong-Jun;Jeong, Ji-Hyeon;Park, Jin-Gu
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.58.2-58.2
    • /
    • 2010
  • FPD (Flat Panel Display) 제조 공정에서 사용되는 패턴은 수 ${\mu}m$ 수준까지 감소하였으며, FPD의 크기는 급격하게 대형화 되여 현재 8세대(2200mm*2500mm)에 이르고 있다. 이에 따라, $1\;{\mu}m$ 이상의 크기를 갖는 오염입자에 의한 수율 저하를 극복하기 위한 세정효율의 향상 및 다량의 초순수 사용에 따른 폐수 발생으로 인한 환경오염, 또한 장비의 크기에 따른 공간 효용성 감소와 이에 따른 공정 비용의 증가 등의 어려움에 직면하고 있다. 따라서, 현장에서는 고효율, 저비용의 세정 공정 기술 개발에 대한 연구가 활발히 진행되고 있다. 이러한 문제점들을 해결 하고자 이류체 노즐 세정 장치와, 화학액 린스를 위한 초순수 Spray, 건조 공정에 해당하는 Air-knife, Halogen lamp로 구성된 소형화 된 고속 FPD(Flat Panel Display) 세정기에 대한 연구를 진행 하였다. 이류체 노즐은 초순수와 $N_2$ 가스를 내부에서 혼합하여 액적(Droplet)을 형성하여 고압으로 분사시키는 장치로서 화학액을 사용하지 않고 물리적인 방법으로 오염입자를 제거한다. Spray는 유기 오염입자 제거를 위한 오존수의 린스 공정을 위해 설치 하였다. 세정 후 표면에 남아있는 기판의 액막(water film)은 고압의 가스를 분사하는 Air-knife를 통해 제거하였으며, 고속 공정시 발생할 수 있는 Air-knife에서 제거하지 못한 잔류 액막을 Halogen lamp를 사용하여 효과적으로 제거함으로써, 물반점(water mark) 없는 건조 공정을 얻을 수 있었다. 실험에는 미세 입자의 정량적인 측정을 위하여 유리 기판 대신에 6인치 실리콘 웨이퍼(P-type (100))를 사용하였으며, > $\;1{\mu}m$ 실리카 입자를 스핀방식을 사용하여 정량적으로 균일하게 오염하였으며, 오염물의 개수 및 분포는 파티클 스캐너 (Surfscan 6200, KLA-Tancor, USA)를 사용하여 분포 및 개수를 정량적으로 측정 하였다. 이류체 노즐은 $N_2$ 가스의 압력과 초순수의 압력을 변화시켜 측정하여, 각각 0.20 MPa, 0.01 MPa에서 최적의 세정 결과를 얻을 수 있었으며, 건조 효율은 Air-Knife의 입사 각도와 건조면 간격, 할로겐 램프의 온도를 조절 하여 최적의 조건을 얻을 수 있었다.

  • PDF

Preference for accessible design features for the elderly housing with its cost information (노약자를 위한 주거에서 비용정보제공에 따른 접근가능한 디자인 요소별 선호도 분석)

  • Lee, So-Young;Yoo, Sung-Eun
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.60-67
    • /
    • 2013
  • Preference studies regarding the elderly housing have been conducted to find out design features in specific needs of certain elderly groups with their various demographic characteristics. The purpose of this study was to investigate preference for accessible design features for the elderly and find out the differences in preference whether the cost information was given or not. Contrast to the previous studies, we suggested some alternatives to fulfill the accessible goals. Preference for each option was investigated and differences in preference with its cost information was also investigated. The total of 700 questionnaires were collected and analyzed using SPSS 18.0. As a result, to remove the level differences, respondents prefer installation of trench to installation of deck or ramp. When people received the cost information, the proportion of selection for each option has slightly changed. The findings of the study suggest that cost information is an important factor for choosing the option for removal of level difference, installation of sink design and holding bars, and installation of elevator. Regardless of age, the respondents prefer sliding door option (its cost is equal to the other option), one of the door option for bath room. It may be due to the relative small area for its installation. It was found that when people recognized the importance of the accessible design features higher, they are ore likely to pay for the option even though its cost is higher. The higher people evaluate the importance of accessible design features, the more they can pay for the option. In general, for the preference of alternatives, there are significant differences between the elderly and the younger.

Application of 3D Digital Documentation to Natural Monument Fossil Site (천연기념물 화석산지의 3차원 디지털 기술 적용)

  • Kong, Dal-Yong;Lim, Jong-Deock;Wohn, Kwang-Yeon;Ahn, Jae-Hong;Kim, Kyung-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.11
    • /
    • pp.492-502
    • /
    • 2011
  • 20 fossil sites of numerous fossil sites in Korea have been designated as Natural Monument for protection and conservation. Many of the sites which is located at the coastal area have been gradually disfigured by natural weathering, erosion and human activity. Thus the conservation of the original form and the documentation for the original figure are necessary. In this study, we applied 3D digital documentation to Natural Monument No. 394, Haenam Uhangri dinosaur, pterosaur, and bird footprint fossil site, for maintaining the original form of the dinosaur footprints. We were able to obtain the 3D digital data on two dinosaur footprint sites, a high resolution distributional map, and more accurate digital data of the dinosaur footprints applied the rendering method by ambient occlusion. 3D digital data on the dinosaur footprints is worth for the conservation and research data, moreover content for applying to the various fields such as to make 3D brochure, interactive contents, and so on.

Ionic Dependence and Modulatory Factors of the Background Current Activated by Isoprenaline in Rabbit Ventricular Cells

  • Leem, Chae-Hun;Lee, Suk-Ho;So, In-Suk;Ho, Won-Kyung;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.26 no.1
    • /
    • pp.15-25
    • /
    • 1992
  • In order to elucidate the properties of the background current whole cell patch clamp studies were performed in rabbit ventricular cells. Ramp pulses of ${\pm}80\;mV$ from holding potential of 40 mV(or 20 mV) at the speed of 0.8 V/sec were given every 30 sec(or 10 sec) and current-voltage diagrams(I-V curve) were obtained. For the activation of the background current isoprenaline, adenosine 3',5'-cyclic monophosphate(dBcAMP), guanosine 3',5'-cyclic monophosphate(cGMP), and $N^6$-2'-o-dibutyryladenosine 3',5'-cyclic monophosphate(dBcAMP) were applied after all known current systems were blocked with 2mM Ba, 1 mM Cd ,5 mM Ni, 10 ${\mu}M$ diltiazem, 10 ${\mu}m$ ouabain, and 20 mM tetraethylammonium(TEA). The conductance of background current in control was $0.65{\pm}0.69$ nS at 0 mV, its I-V curves was almost linear and reversed near 50 mV. When there was no taurine in pipette solution, isoprenaline hardly activated the background current but when taurine existed in pipette solution, isoprenaline activated the larger background current. Cyclic AMP or cyclic GMP alone had little effect on the activation of the background current, while cGMP potentiated cGMP effect. When the background current was activated with cGMP and cAMP, isoprenaline could not further increased the background current. The background current activated by isoprenaline depended on extracellular $Cl^-$ concentration and its reversal potential was shifted according to chloride equilibrium potential. The change of extracellular $Na+$ concentration had little effect on reversal potential of the background current activated by isoprenaline.

  • PDF

Three-dimensional Stability Analysis for an Underground Disposal Research Tunnel (지하처분연구시설에 대한 3차원 터널 안정성 해석)

  • 권상기;조원진
    • Tunnel and Underground Space
    • /
    • v.14 no.3
    • /
    • pp.188-202
    • /
    • 2004
  • If an underground research facility for the validation of disposal concept is constructed in KAERI, it is expected to have a thick weathered zone and varying surface topology. In this study, the influence of different geological conditions, tunnel slope, tunnel size, and sequential excavation is investigated by 3D mechanical analysis using FLAC3D. Around the tunnel, it is not expected to develop any plastic zone and the maximum stress might be as high as 5 ㎫. The maximum compressive stress will be developed at about 20 m to e dead end of the tunnel. There is no difference on stress and displacement distributions between the cases with and without sequential excavation. It is expected to have stress release in the roof and floor after the excavation of the tunnel. There is no significant influence of weathered zone size, tunnel size, and tunnel slope on the stress and displacement distributions. The modeling for the intersection shows the minimum factor of safety is above 3, when the in situ stress ratio K is 3. From the study, it was possible to demonstrate that the small scale disposal research tunnel in KAERI will be mechanically stable.

Analysis of Driving Conditions and Traffic Accidents in the Case of Trumpet Interchange Ramps (트럼펫 IC 램프의 운전조건과 교통사고 분석)

  • Kim, Tae-Yeong;Park, Byeong-Ho
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.1 s.94
    • /
    • pp.73-79
    • /
    • 2007
  • This study deals with traffic accidents at the ramps of trumpet interchanges. The purpose of the study is to analyze the relations between tke turning direction of ramps (and combinations with other factors) and traffic accidents. In Pursuing this analysis, this study gives particular attention to the combination of turning direction and grade and the combination of turning direction and radius of curvature in the case of the trumpet interchange ramps. The null hypothesis tests show that the average accident number and average accident rate ate rejected at the 90% and 95% significance level respectively Also. the null hypothesis tests show that the combinations or turning direction and Evade as well as turning direction and radius are all rejected at the 95% significance level. In summary, right turn movements ate more dangerous than left turns on the trumpet interchange vamps. Also, ramps with a right turn and up grade or with a left turn and radius more than 200m have more traffic accident Potential than other types of ramps.

Performance Evaluation of Bridge Deck Materials based on Ordinary Portland Cement Concrete (보통 포틀랜드 콘크리트 기반 교면포장 재료 성능 평가)

  • Nam, Jeong-Hee;Jeon, Seong Il;Kwon, Soo Ahn
    • International Journal of Highway Engineering
    • /
    • v.19 no.6
    • /
    • pp.129-137
    • /
    • 2017
  • PURPOSES : The purpose of this study is to develop bridge deck concrete materials based on ordinary Portland cement concrete, and to evaluate the applicability of the developed materials through material properties tests. METHODS : For field implementation, raw material (cement, fine aggregate, and coarse aggregate) properties, fresh concrete properties (slump and air content), strength (compressive, flexural and bond strength) gain, and durability (freeze-thaw resistance, scaling resistance, and rapid chloride penetrating resistance) performance were evaluated in the laboratory. RESULTS : For the selected binder content of $410kg/m^3$, W/B = 0.42, and S/a = 0.48, the following material performance results were obtained. Considering the capacity of the deck finisher, a minimum slump of 150 mm was required. At least 6 % of air content was obtained to resist freeze-thaw damage. In terms of strength, 51.28 MPa of compressive strength, 7.41 MPa of flexural strength, and 2.56 MPa of bond strength at 28 days after construction were obtained. A total of 94.9 % of the relative dynamic modulus of elasticity after 300 cycles of freeze-thaw resistance testing and $0.0056kg/m^2$ of weight loss in a scaling resistance test were measured. However, in a chloride ion penetration resistance test, the result of 3,356 Coulomb, which exceeds the threshold value of the standard specification (1000 Coulomb at 56 days) was observed. CONCLUSIONS : Instead of using high-performance modified bridge deck materials such as latex or silica fume, we developed an optimum mix design based on ordinary Portland cement concrete. A test construction was carried out at ramp bridge B (bridge length = 111 m) in Gim Jai City. Immediately after the concrete was poured, the curing compound was applied, and then wet mat curing was applied for 28 days. Considering the fact that cracks did not occur during the monitoring period, the applicability of the developed material is considered to be high.

Effects of Root Gap on Residual Stresses and Deformation in the Multi-Pass Weld of Thick Plates for Steel Bridge (교량용 후판 다층용접시 잔류응력과 변형에 미치는 루트간격의 영향)

  • 장경복;김하근;강성수
    • Journal of Welding and Joining
    • /
    • v.17 no.1
    • /
    • pp.88-96
    • /
    • 1999
  • The effects of root gap on welding residual stress and deformation are dealt with the multi-pass weldment with three kinds(0, 6, 30mm) of root gap by F.E.M common code, and then compared with experiment data. In this analysis, an 100% ramp heat input model was used to avoid numerical convergence problem due to an instantaneous increase in temperature near the fusion zone, and the effect of a moving arc in a two dimensional plane was also included. During the analysis, a small time increment was applied in a period with instantaneous temperature fluctuation while a large time increment was used in the rest period. The residual stress is distributed as symmetric types and maximum value is also equivalent when the weldment with 0mm and 6mm root gap is welded. In the case of 30mm root gap welding, the distribution of the residual stress extends over a wide range as asymmetric types due to the built-up weld, and most of the residual stress is biased in the side of a built-up weld part. In case of 0mm gap welding and 6mm gap welding, a little angular distortion occurs, but the level of deformation is small. When the weldment with 30mm root gap is welded, the angular deformation of the asymmetric types, however, occurs larger than the other specimens. The experimental and the analytic results show good coincidence and indicate that the welding residual stress and deformation distribution of 30 mm root gap specimen may be asymmetric and the amplitude is larger than those of root gap specimen under standard.

  • PDF

A Study on Application of LID Technology for Improvement of Drainage Capacity of Sewer Network in Urban Watershed (도시 유역의 우수관망 통수능 개선을 위한 LID 기술 적용 연구)

  • Baek, Jongseok;Kim, Baekjoong;Lee, Sangjin;Kim, Hyungsan
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.617-625
    • /
    • 2017
  • Both domestic and overseas urban drainage systems have been actively researched to solve the problems of urban flash floods and the flood damage that is caused by local downpours. Recent urban planning has been designed to better manage the floods of decentralized rainfall-management systems, and the installation of green infrastructure and low-impact development (LID) facilities at national ministries has been recommended. In this study, we use the EPA SWMM model to construct a decentralized rainfall-management network for each small watershed, and we analyze the effect of the drainage-capacity improvement from the installation of the LID technologies in vulnerable areas that replaces the network-expansion process. In the design of the existing urban piping systems, it is common to increase the pipe size due to the increment of the impervious area, the steep terrain, and the sensitive entrance-ramp junction; however, the installation of green infrastructure and LID facilities will be sufficient for the construction of a safe urban drainage system. The applications of LID facilities and green infrastructure in urban areas can positively affect the recovery of the corresponding water cycles to a healthy standard, and it is expected that further research will occur in the future.