• 제목/요약/키워드: rain and wind action

검색결과 8건 처리시간 0.02초

Effect of rain on flutter derivatives of bridge decks

  • Gu, Ming;Xu, Shu-Zhuang
    • Wind and Structures
    • /
    • 제11권3호
    • /
    • pp.209-220
    • /
    • 2008
  • Flutter derivatives provide the basis of predicting the critical wind speed in flutter and buffeting analysis of long-span cable-supported bridges. Many studies have been performed on the methods and applications of identification of flutter derivatives of bridge decks under wind action. In fact, strong wind, especially typhoon, is always accompanied by heavy rain. Then, what is the effect of rain on flutter derivatives and flutter critical wind speed of bridges? Unfortunately, there have been no studies on this subject. This paper makes an initial study on this problem. Covariance-driven Stochastic Subspace Identification (SSI in short) which is capable of estimating the flutter derivatives of bridge decks from their steady random responses is presented first. An experimental set-up is specially designed and manufactured to produce the conditions of rain and wind. Wind tunnel tests of a quasi-streamlined thin plate model are conducted under conditions of only wind action and simultaneous wind-rain action, respectively. The flutter derivatives are then extracted by the SSI method, and comparisons are made between the flutter derivatives under the two different conditions. The comparison results tentatively indicate that rain has non-trivial effects on flutter derivatives, especially on and $H_2$ and $A_2$thus the flutter critical wind speeds of bridges.

A study on the action mechanism of internal pressures in straight-cone steel cooling tower under two-way coupling between wind and rain

  • Ke, S.T.;Du, L.Y.;Ge, Y.J.;Yang, Q.;Wang, H.;Tamura, Y.
    • Wind and Structures
    • /
    • 제27권1호
    • /
    • pp.11-27
    • /
    • 2018
  • The straight-cone steel cooling tower is a novel type of structure, which has a distinct aerodynamic distribution on the internal surface of the tower cylinder compared with conventional hyperbolic concrete cooling towers. Especially in the extreme weather conditions of strong wind and heavy rain, heavy rain also has a direct impact on aerodynamic force on the internal surface and changes the turbulence effect of pulsating wind, but existing studies mainly focus on the impact effect brought by wind-driven rain to structure surface. In addition, for the indirect air cooled cooling tower, different additional ventilation rate of shutters produces a considerable interference to air movement inside the tower and also to the action mechanism of loads. To solve the problem, a straight-cone steel cooling towerstanding 189 m high and currently being constructed is taken as the research object in this study. The algorithm for two-way coupling between wind and rain is adopted. Simulation of wind field and raindrops is performed with continuous phase and discrete phase models, respectively, under the general principles of computational fluid dynamics (CFD). Firstly, the rule of influence of 9 combinations of wind sped and rainfall intensity on flow field mechanism, the volume of wind-driven rain, additional action force of raindrops and equivalent internal pressure coefficient of the tower cylinder is analyzed. On this basis, the internal pressures of the cooling tower under the most unfavorable working condition are compared between four ventilation rates of shutters (0%, 15%, 30% and 100%). The results show that the 3D effect of equivalent internal pressure coefficient is the most significant when considering two-way coupling between wind and rain. Additional load imposed by raindrops on the internal surface of the tower accounts for an extremely small proportion of total wind load, the maximum being only 0.245%. This occurs under the combination of 20 m/s wind velocity and 200 mm/h rainfall intensity. Ventilation rate of shutters not only changes the air movement inside the tower, but also affects the accumulated amount and distribution of raindrops on the internal surface.

Rain-wind induced vibrations of cables in laminar and turbulent flow

  • Peil, U.;Dreyer, O.
    • Wind and Structures
    • /
    • 제10권1호
    • /
    • pp.83-97
    • /
    • 2007
  • In the last decades there have been frequent reports of oscillations of slender tension members under simultaneous action of rain and wind - characterized by large amplitudes and low frequencies. The members, e.g. cables of cable-stayed bridges, slightly inclined hangers of arch bridges or cables of guyed-masts, show a circular cross section and low damping. These rain-wind induced vibrations negatively affect the serviceability and the lifespan of the structures. The present article gives a short literature review, describes a mathematical approach for the simulation of rain-wind induced vibrations, sums up some examples to verify the calculated results and discusses measures to suppress the vibrations.

A study on the working mechanism of internal pressure of super-large cooling towers based on two-way coupling between wind and rain

  • Ke, Shitang;Yu, Wenlin;Ge, Yaojun
    • Structural Engineering and Mechanics
    • /
    • 제70권4호
    • /
    • pp.479-497
    • /
    • 2019
  • In the current code design, the use of a uniform internal pressure coefficient of cooling towers as internal suction cannot reflect the 3D characteristics of flow field inside the tower body with different ventilation rate of shutters. Moreover, extreme weather such as heavy rain also has a direct impact on aerodynamic force on the internal surface and changes the turbulence effect of pulsating wind. In this study, the world's tallest cooling tower under construction, which stands 210m, is taken as the research object. The algorithm for two-way coupling between wind and rain is adopted. Simulation of wind field and raindrops is performed iteratively using continuous phase and discrete phase models, respectively, under the general principles of computational fluid dynamics (CFD). Firstly, the rule of influence of 9 combinations of wind speed and rainfall intensity on the volume of wind-driven rain, additional action force of raindrops and equivalent internal pressure coefficient of the tower body is analyzed. The combination of wind velocity and rainfall intensity that is most unfavorable to the cooling tower in terms of distribution of internal pressure coefficient is identified. On this basis, the wind/rain loads, distribution of aerodynamic force and working mechanism of internal pressures of the cooling tower under the most unfavorable working condition are compared between the four ventilation rates of shutters (0%, 15%, 30% and 100%). The results show that the amount of raindrops captured by the internal surface of the tower decreases as the wind velocity increases, and increases along with the rainfall intensity and ventilation rate of the shutters. The maximum value of rain-induced pressure coefficient is 0.013. The research findings lay the basis for determining the precise values of internal surface loads of cooling tower under extreme weather conditions.

재해연보기반 풍랑피해예측함수 개발 : 서해연안지역 (Development of the Wind Wave Damage Estimation Functions based on Annual Disaster Reports : Focused on the Western Coastal Zone)

  • 추태호;조현민;심상보;박상진
    • 한국콘텐츠학회논문지
    • /
    • 제18권1호
    • /
    • pp.154-163
    • /
    • 2018
  • 우리나라뿐만 아니라 전 지구적으로 호우발생 빈도의 증가, 태풍이나 허리케인 세기의 강화 등에 따라 대규모 자연재해의 발생횟수와 피해액은 지속적으로 증가하는 추세이다. 태풍, 홍수, 호우, 강풍, 풍랑, 해일, 조수, 대설, 가뭄, 지진, 황사 등과 같은 자연재해는 발생지점과 규모를 예측하기 어려우며, 전조현상이 명확하게 나타나지 않아 대응에 많은 어려움이 존재한다. 그러나 자연재해의 피해규모를 예측할 수 있다면, 조기대응을 통해 피해를 저감할 수 있을 것이다. 따라서 본 연구에서는 국민안전처에서 발간하는 재해연보('91년~'15년)를 기반으로 서해연안지역의 풍랑피해함수를 개발하였다. 풍랑피해함수는 지역별, 시설별로 구분하여 개발하였으며, NRMSE는 1.94%~26.07%로 분석되었다. 개발된 식을 통해 피해규모를 예측하고, 그에 대한 적절한 대응이 이루어진다면, 피해를 저감할 수 있을 것으로 사료된다.

Moisture distribution in concrete subjected to rain induced wetting-drying

  • Sarkar, Kaustav;Bhattacharjee, Bishwajit
    • Computers and Concrete
    • /
    • 제14권6호
    • /
    • pp.635-656
    • /
    • 2014
  • A rational estimation of moisture distribution in structural concrete is vital for predicting the possible extent and rate of progression of impending degradation processes. The paper proposes a numerical scheme for analysing the evolution of moisture distribution in concrete subjected to wetting-drying exposure caused by intermittent periods of rainfall. The proposed paradigm is based on the stage wise implementation of non-linear finite element (FE) analysis, with each stage representing a distinct phase of a typical wet-dry cycle. The associated boundary conditions have been constituted to realize the influence of various meteorological elements such as rain, wind, relative humidity and temperature on the exposed concrete surface. The reliability of the developed scheme has been demonstrated through its application for the simulation of experimentally recorded moisture profiles reported in published literature. A sensitivity analysis has also been carried out to study the influence of critical material properties on simulated results. The proposed scheme is vital to the service life modelling of concrete structures in tropical climates which largely remain exposed to the action of alternating rains.

재해통계기반 남해연안지역 풍랑피해액예측함수 제안 (Proposal for Wind Wave Damage Cost Estimation at the Southern Coastal Zone based on Disaster Statistics)

  • 추태호;윤관선;권용빈;박상진;김성률
    • 한국콘텐츠학회논문지
    • /
    • 제17권4호
    • /
    • pp.267-274
    • /
    • 2017
  • 태풍, 지진, 홍수, 폭우, 가뭄, 폭염, 풍랑, 쓰나미 등과 같은 자연재해는 발생지점과 규모를 예측하기 어려울 뿐만 아니라 인간생활에 피해를 주고 있다. 하지만, 재해통계를 기반으로 과거피해사례와 피해액을 분석하여 예상피해액을 산출할 수 있다면, 산출한 결과를 바탕으로 즉시 초동조치에 임할 수 있고, 피해를 최소한으로 저감할 수 있을 것이다. 따라서, 본 논문에서는 우리나라 남해연안지역을 대상으로 풍랑피해액예측함수를 제안한다. 본 예측함수는 재해연보('91년~'14년)에 기록된 풍랑 및 태풍의 재해통계, 남해연안지역의 특성을 고려한 인자, 해안 기상조건을 설명변수로 개발하였다.

다층지반 하에서 수평하중을 받는 말뚝의 회전점 (Rotation Point of Laterally Loaded Pile Under Multi Layered Soil)

  • 강병준;경두현;홍정무;이준환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.708-712
    • /
    • 2008
  • Piles and pile foundations have been in common use since very early times. Usually function of piles is to carry load to a depth at which adequate support is available. Another important use of piles is to furnish lateral support and nowadays it is getting highlighted due to the wind load, lateral action of earthquake, and so on. After Broms (1964), many researchers have been suggested methods for estimating lateral capacity of pile. But each method assumes different earth pressure distribution and lateral earth pressure coefficient and it gives confusion to pile designers. Lateral earth pressure, essential in lateral capacity estimation, influenced by pile's behavior under lateral load. Prasad and Chari (1999) assumed the rotation point of pile and suggested an equation of ultimate lateral load capacity. In this study, we investigate the depth of rotation point in both homogeneous soil and multi layered soil, and compare to the estimation value by previous research. To model the pile set up in the sand, we use the chamber and small scale steel pile, and rain drop method. Test results show the rotation point is formed where the Prasad and Chari's estimation value, and they also show multi layered condition affects to location of rotation point to be scattered.

  • PDF