• 제목/요약/키워드: radon concentration

검색결과 186건 처리시간 0.021초

코코넛 기반 활성탄 필터의 라돈 제거 효율 (Radon Removal Efficiency of Activated Carbon Filter from Coconut)

  • 안윤진;김기섭;김태환;김상록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권2호
    • /
    • pp.141-149
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences plans to produce 225Ac, a therapeutic radio-pharmaceutical for precision oncology, such as prostate cancer. Radon, a radioactive gas, is generated by radium, the target material for producing 225Ac. The radon concentration is expected to be about 2000 Bq·m-3. High-concentration radon-generating facilities must meet radioactive isotope emission standards by lowering the radon concentration. However, most existing studies concerning radon removal using activated carbon filters measured radon levels at concentrations lower than 1000 Bq·m-3. This study measured 222Rn removal of coconut-based activated carbon filter under a high radon concentration of about 2000 Bq·m-3. The 222Rn removal efficiency of activated carbon impregnated with triethylenediamine was also measured. As a result, the 222Rn removal amount of the activated carbon filter showed sufficient removal efficiency in a 222Rn concentration environment of about 2000 Bq·m-3. In addition, despite an expectation of low radon reduction efficiency of Triethylenediamine-impregnated activated carbon, it was difficult to confirm a significant difference in the results. Therefore, it is considered that activated carbon can be used as a radioisotope exhaust filter regardless of whether or not Triethylenediamine is impregnated. The results of this study are expected to be used as primary data when building an air purification system for radiation safety management in facilities with radon concentrations of about 2000 Bq·m-3.

라돈농도 측정을 위한 고체비적검출기의 상대교정법 개발 및 응용 (Development of Relative Calibration Method for Measurement of Radon and Application)

  • 박영웅;양현수
    • Journal of Radiation Protection and Research
    • /
    • 제22권4호
    • /
    • pp.243-250
    • /
    • 1997
  • 공기 중의 라돈 농도를 측정하기 위한 고체비적검출기의 상대교정법을 개발하였으며, 상대 교정된 CN-85를 이용하여 15층 아파트 층 별로 실내 공기 중의 라돈 농도를 측정한 후 피폭 선량을 계산하여 보았다. 측정 결과 아파트 실내 공기 중에서의 라돈 농도는 대체적으로 상층으로 올라갈수록 감소하는 경향이 있었으나, 환기 횟수에 크게 영향을 받음을 알 수 있었다. 측정값의 평균은 $1.50{\pm}0.51pCi/1$ 였으며, 최대값과 최소값은 각각 $2.68{\pm}0.32pCi/l$, $0.69{\pm}0.16pCi/l$였다.

  • PDF

동북아 오염물질 장거리이동 분석을 위한 서울시 대기 중 라돈농도의 시계열적 특성에 관한 연구 (Time Series Observations of Atmospheric Radon Concentration in Seoul, Korea for an Analysis of Long-Range Transportation of Air Pollutants in the North-East Asia)

  • 김윤신;이철민;김기연;전형진;김종철
    • 한국환경보건학회지
    • /
    • 제33권4호
    • /
    • pp.283-292
    • /
    • 2007
  • Atmospheric concentrations of radon had been continuously observed in Seoul, Korea since December 1999, as a tracer for long-range transport of air pollutants from China continent to Korea. In order to study radon as a tracer of long-range transport, it is important to know information about the atmospheric distribution and variation of radon concentration and its time variation. Atmospheric radon concentration are measured with electrostatic radon monitor(ERM) at Hanyang University located in Eastern area of Seoul. Air sample is taken into a vessel of ERM, and alpha particles emitted by radon daughters $Po^{218}$ are detected with ZnS(Ag) scintillation counter. Hourly mean concentrations and hourly alpha counts are recorded automatically. The major results obtained from time series observation of atmospheric radon were as follows : (1) The mean of airborne radon concentration in Seoul was found to be $7.62{\pm}4.11\;Bq/m^3$ during December $1999{\sim}January$ 2002. (2) The hourly variation of radon concentrations showed the highest in 8:00AM ($8.66{\pm}4.22\;Bq/m^3$) and the lowest in 3:00AM ($6.62{\pm}3.70\;Bq/m^3$) and 5:00AM ($6.62{\pm}3.39\;Bq/m^3$). (3) the seasonal variation of radon concentrations showed higher during winter-to-fall and lower during summer-to-spring. (4) Correlation between airborne radon concentration and the meteorological factors were -0.21 for temperature, 0.09 for humidity, -0.20 for wind speed, and 0.04 for pressure. (5) The mean difference of airborne radon concentration between Asian dust ($5.36{\pm}1.28\;Bq/m^3$) and non-Asian dust ($4.95{\pm}1.49\;Bq/m^3$) phenomenon was significant (p=0.08). We could identify time series distribution of radon concentration related meteorological factors. In addition, radon can be considered a good natural tracer of vertical dispersion and long-range transport.

사무실 내 라돈 농도에 관한 연구 (A Study on the Radon Concentration in the Office)

  • 최현우;김치년;원종욱;김홍관;노재훈
    • 한국산업보건학회지
    • /
    • 제26권3호
    • /
    • pp.334-341
    • /
    • 2016
  • Objectives: This study is aimed at examining radon exposure in offices and the factors that can influence the concentrations. Methods: Indoor radon concentrations in a total of 30 places were measured from January 18 to 21, 2016, targeting six buildings in Seoul with different completion years. The measurement was conducted according to the radon measurement guidelines for indoor air suggested by the Ministry of Environment. Results: As a result of comparing each average concentration, underground area concentration was $42.850{\pm}22.501Bq/m^3$, and that of the ground floors was $27.850{\pm}12.232Bq/m^3$, which was lower than the concentration in the underground areas and statistically significant (p=0.045). As a result of comparing the concentration according to whether or not outside air entered, the average concentration for ventilated areas was $24.876{\pm}11.833Bq/m^3$, and the average concentration for enclosed areas was $47.892{\pm}19.375Bq/m^3$. The concentration in ventilated areas was lower at a statistically significant level (p=0.001). Finally, as a result of the multiple regression analysis for evaluating the factors influencing radon concentration, only ventilation was significant (p=0.007). Conclusions: As a result of measuring radon in office buildings, there was no place that exceeding the recommended standard of the US EPA, but the concentration in poorly ventilated areas was measured to be high. An effort to manage radon concentration and reduce it through the improvement of ventilation systems, repeated measurement is necessary in the future.

건축재료로부터 방출되는 라돈방사능 감소를 위한 흑탄과 활성탄 효과 (Effect of Black Charcoal and Activated Carbon for Reduction of Radon Radioactivity that Emitted from Building Materials)

  • 조윤민;이화형
    • 한국가구학회지
    • /
    • 제22권1호
    • /
    • pp.13-17
    • /
    • 2011
  • Recently, interest in indoor air quality is increasing. Especially, radon radioactivity among the indoor air is a well-known risk factor for lung cancer because of ionizing radiation in the form of ${\alpha}$-particles. This study was carried out to investigate effect of black charcoal and activated carbon for reduction of radon radiation that emitted from building materials. Black charcoal and activated carbon were used as a barrier which was against the infiltration of radon. The source of radon was gypsum board. Two types of charcoal barrier were powder- and board-type with 5 mm, 10 mm thickness respectively. The method for this determination is evaluated radon concentration in chamber. The measurements were performed with radon detector, SARAD3120. Results of this study are as following: Black charcoal and activated carbon confirmed the highly efficient barrier. Radon concentration was reduced from 72% to 85% as compared the control chamber. Radon reduction capability, however, was no difference as barrier's types. Results obtained in ventilation condition, radon concentration shows 5.93 pCi/L on average in the closed condition and shows 2.69 pCi/L in the opened condition.

  • PDF

Analysis of Seasonal Airborne Radon Concentration Characteristics in Public-Use Facilities

  • Young-Do KIM;Woo-Taeg KWON
    • 웰빙융합연구
    • /
    • 제6권2호
    • /
    • pp.1-7
    • /
    • 2023
  • Purpose: The purpose of this study is to investigate the characteristics of airborne radon concentration by season in public-use facilities in South Korea. Research design, data and methodology: The data is provided by the public data portal, and public-use facilities nationwide where radon in the air is measured are specialized sanatorium for senior citizens, libraries, childcare facilities, postpartum care centers, medical institutions, funeral halls, underground shopping malls, and underground subway stations. Results: The facility with the highest radon concentration in public-use facilities was childcare facilities with an average of 50.2 ± 21.7 Bq/m3, while the average of medical institutions was the lowest at 24.8 ± 5.7 Bq/m3. The season with the largest difference in average radon concentration between childcare facilities and medical institutions was in the order of fall (28.6 Bq/m3), followed by winter (28.1 Bq/m3), spring (23.0 Bq/m3), and summer (22.0 Bq/m3). Conclusions: The main concentration levels of each public-use facility shown in this study are all below domestic and international standards, but there is a significant concentration difference between facilities. By season, winter showed the highest average concentration (40.6 ± 21.3 Bq/m3) and summer showed the lowest average concentration (23.8 ± 14.0 Bq/m3).

서울지역 지하철역의 라돈농도 분포 특성 (Distribution of $^{222}Rn$ Concentration in Seoul Subway Stations)

  • 전재식;김덕찬
    • 대한환경공학회지
    • /
    • 제28권6호
    • /
    • pp.588-595
    • /
    • 2006
  • 본 연구는 서울지역 지하철역 실내 공기 중 라돈분포를 조사하여 그 발생원을 추적 확인하기 위하여 수행되었다. 1998년부터 2004년까지 232개 역사를 대상으로 알파비적검출기를 사용하여 실내 공기 중 장기라돈을 측정하였으며 지하수중 라돈농도는 알파입자계수법에 의하여 측정하였다. 라돈의 주 발생원을 추적하기 위하여 8개 역사를 선정하여 각 역사의 승강장과 인접터널에 대한 공기 중 라돈농도를 조사하였다. 전체역사에 대한 라돈농도 분석결과 기하평균 및 산술평균은 각각 $1.40{\pm}1.94pCi/L,\;1.65{\pm}1.07$였으며, 승강장과 매표소의 기하평균은 각각 $1.54{\pm}1.96pCi/L,\;1.23{\pm}1.88pCi/L$로 승강장에서의 라돈농도가 매표소의 농도보다 더 높게 나타났다. 지질구조와 지하역사의 라돈분포는 밀접한 상관성을 보였으며 터널내부와 지하수중의 라돈농도는 역사 승강장의 라돈농도에 크게 영향을 미치고 있었다. 또한 역사의 승강장이 위치하고 있는 깊이 정도에 따라 라돈농도의 차이를 보였다(p<0.05).

실내 체적과 라돈 농도와의 상관관계 연구 (A Study on the Correlation between the Volume of Indoor Space and the Measured Concentration of Indoor Radon)

  • 강성아;한동현;김종일
    • Journal of Radiation Protection and Research
    • /
    • 제32권3호
    • /
    • pp.97-104
    • /
    • 2007
  • 전주시에 소재한 아파트의 큰 방과 작은 방을 대상으로 실내 체적과 측정되는 라돈 농도와의 상관 관계를 분석하였다. 또한 실내의 라돈 농도를 측정하여 실내의 시간별 라돈 농도의 변화를 파악하고 이를 토대로 실내 라돈의 년간 피폭선량을 계산하였다. 본 연구를 위하여 각각 8개의 아파트 큰 방과 작은 방을 대상으로 라돈 농도를 측정하였으며, 큰 방의 평균 체적은 $31.59\;m^3$ 그리고 작은 방의 평균 체적은 $16.82\;m^3$이었다. 큰 방의 평균 라돈 농도는 $71.73\;Bq/m^3$, 작은 방의 평균 라돈 농도는 $108.51\;Bq/m^3$로 측정되어 실내 체적과 실내 라돈 농도는 반비례 관계로 나타났다. 밀폐된 실내 라돈 농도의 주 발생원이 건축자재임을 감안하여 건물 벽의 표면적을 체적으로 나누어 계측해 본 결과 표면적/체적의 비가 클수록 측정되는 실내 라돈 농도가 크게 나타났다. 실내 라돈 농도의 하루 중 시간에 따른 변화를 조사한 결과 오전 $8{\sim}10$시에 일 최고 농도($114.5\;Bq/m^3$)를 보였고, 오후 $2{\sim}4$시에 일 최저농도($67.7\;Bq/m^3$)를 나타냈으며, 하루 중 라돈 농도의 변화는 약 $46.8\;Bq/m^3$이었다. 8개 지점의 실내 라돈의 연간 피폭선량을 계산해 본 결과 0.3에서 2.16 mSv/yr사이로 나타나, 일부 아파트의 피폭선량이 국제방사선영향과학위원회(UNSCEAR)가 제시한 수치인 1.3 mSv/yr를 초과했다.

제주지역 일부 농업 시설 내 라돈 농도 예비 조사 (A Preliminary Investigation of Radon Concentration for Some Agricultural Greenhouses in Jeju Island)

  • 강태우;송명한;김태형;장병욱;김용재;김근호;박재우
    • 한국환경농학회지
    • /
    • 제31권1호
    • /
    • pp.9-15
    • /
    • 2012
  • 본 연구는 제주지역에서 온실 내 냉난방 및 $CO_2$ 공급 목적으로 지하공기를 이용하는 14개 농업 시설을 대상으로 약 3개월 동안 지하공기 이용 온실과 미이용 공간 내 라돈 농도 및 지하공기 이용 시설의 가동에 따른 지하공기 유입구 내 라돈 농도 분포를 조사하였다. 장기간 라돈 농도는 수동형 알파 입자비적 검출기(Raduet, Radosys Ltd., Hungary)로, 실시간 라돈 농도는 능동형 연속측정 검출기(RAD7, Durridge Co., USA)를 이용하여 측정하였다. 지하공기 이용 온실 내 라돈 농도는 지하공기 미이용 공간과 국내 가옥의 실내 평균값보다 높은 범위였으며, 대부분 농업 시설에서는 국제방사선 방호위원회에서 권고한 근무지에서의 참조준위 1,000 Bq/$m^3$ 보다 낮은 반면 한 개 지점에서는 높은 결과를 보였다. 장기간 및 실시간 지하공기 이용 시설의 가동에 따른 유입구의 라돈 농도 분포는 각각 1,228~5,259 및 3,322~17,900 Bq/$m^3$ 범위로 지역적인 차이를 보였다. 본 연구 결과, 지하공기 중 라돈 농도는 농업 시설이 위치한 지역의 지질 특성 및 시추공 깊이와 밀접한 관계가 있을 것으로 판단된다.

핀 포토다이오드를 이용한 보급형 라돈 검출기의 구현 (Implementation of Popular Radon Detector Using Pin Photodiode)

  • 윤성하;김재학;김규식
    • 전자공학회논문지
    • /
    • 제53권11호
    • /
    • pp.99-106
    • /
    • 2016
  • 라돈이 기관지나 폐포에 머무르게 될 때 라돈의 붕괴로 인해 자핵종(알파선, 베타선, 감마선 등)들이 생성되면서 이것들이 방사선을 방출하는데 세포의 염색체에 돌연변이를 일으켜 폐암을 발생할 가능성이 존재한다. 다시 말해 폐암의 원인이 라돈가스 때문이라기보다는 흡수된 일부 라돈의 붕괴로 인해 생기는 부산물이 방사선을 방출하기 때문이라고 할 수 있다. 사람이 연간 노출되는 방사선의 82%가 자연방사선에 의한 것인데 그중 대부분이 라돈이다. 실내의 라돈 농도를 적절하게 제어할 수 있다면 폐암의 발생확률을 30%나 억제할 수 있다고 알려져 있다. 아직까지 실내의 라돈의 농도를 측정하는 데는 외국의 라돈 센서를 사용하고 있는 실정이다. 실내 라돈 방출량에 대한 데이터 구축과 국내에 맞는 실용적인 라돈측정기기를 개발하도록하는 연구가 필요하다. 본 논문에서는 PIN Photodiode를 이용하여 라돈의 농도를 측정하는 라돈 검출기 구현 방법을 제안한다. 실험을 통해서, PIN photodiode의 라돈 센서 모듈로서의 이용 가능성에 대하여 확인하였다.