• Title/Summary/Keyword: radiotracer method

Search Result 24, Processing Time 0.029 seconds

Prognostic Value of $^{99m}Tc-Phytate$ Liver Scintigraphy in Patients with Liver Cirrhosis ($^{99m}Tc-phytate$ 간스캔을 이용한 간 경변증의 예후 평가)

  • Yang, Soo-Hyun;Park, Bong-Chul;Che, Dong-Ho;Cho, Jun-Koo;Park, Sung-Ki;Byun, Jong-Hoon;Song, Tae-Won
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.76-80
    • /
    • 1991
  • To evaluate the prognostic significance of $^{99m}Tc-phytate$ liver scintigraphy in patients with cirrhosis, we measured the grade of extrahepatic uptake (EHU) of $^{99m}Tc-phytate$, from 0 (absent EHU) to 5 (important EHU), according to the relative distribution of the radiotracer among liver, spleen and bone marrow. The results were as follows: 1) EHU score was correlated to the Pugh score (r=0.64) and to survival. 2) The ROC curve on an observed status of death was superior for EHU score. In conclusion, $^{99m}Tc-phytate$ liver scintigraphy nay be a useful prognostic method in patients with liver cirrhosis.

  • PDF

Application of radiotracer technique in remediation of Zn(II) from aqueous solutions by dry cowdung powder

  • Shaikh, Sabrina Afzal;Bagla, Hemlata Kapil
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.456-461
    • /
    • 2022
  • Heavy metal pollution is caused due to anthropogenic activities and is considered as a serious environmental problem which endangers human health and environment. The present study deals with biosorption, an eco-friendly technique for the removal of heavy metal Zn(II) from aqueous medium. Various natural materials have been explored for the uptake of metal ions, where most of them are physically or chemically enhanced. Dry cowdung powder (DCP) has been utilized as a low-cost, environmentally friendly humiresin without any pre-treatment, thus demonstrating the concept of Green Chemistry. Batch biosorption studies using 65Zn(II) tracer were performed and the impact of different experimental parameters was studied. Results revealed that at pH 6, 94 ± 2% of Zn(II) was effectively biosorbed in 5 min, at 303 K. The process was spontaneous and exothermic, following pseudo-second-order reaction. The mechanism of heavy metal biosorption employing green adsorbent was therefore elucidated in order to determine the optimal method for removing Zn(II) ions. DCP has a lot of potential in the wastewater treatment industry, as seen by its ability to meet 3A's affordability, adaptability, and acceptability criteria. As a result, DCP emerges as one of the most promising challengers for green chemistry and the zero-waste idea.

Radioimmunoassay for Determination of Serum Macrophage Migration Inhibitory Factor (혈중 대식세포 유주 저지 인자 측정을 위한 방사면역측정법)

  • Lee, Tae-Sup;Shin, Seok-Hwan;Song, Jee-In;Woo, Kwang-Sun;Chung, Wee-Sup;Choi, Chang-Woon;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.532-539
    • /
    • 2004
  • Purpose: There has been a renewal of interest in Macrophage migration inhibitory factor (MIF), especially correlation in pathogenesis of sepsis by many infectious diseases and in regulation of host inflammatory and immune response. We developed immunoradiometric assay (IRMA) to determine serum human MIF concentration. Materials and Methods: The IRMA system utilizes solid phase bound monoclonal anti-recombinant human MIF (rhMIF) antibody as a capture antibody, biotinylated polyclonal anti-rhMIF antibody as a detector antibody. We applied with rhMIF that concentration of standard solutions increased from 0 ng/ml to 100 ng/ml. We used $^{125}I$-streptavidin (SA) as radiotracer to determination of rhMIF concentration. Streptavidin was labeled with $^{125}I$ by Chloramine-T method and $^{125}I$-SA was purified by ultracentrifugation. $^{125}I$-SA stability was evaluated by ITLC analysis at $4^{\circ}C$ and room temperatures until 60days. To validate IRMA system for MIF, we experimented intra-assay and inter-assay coefficients of variation, recovery test and dilution test. Results: Radiolabeling yield of $^{125}I$-SA was 87% and purified $^{125}I$-SA retained above 99% radiochemical purity. $^{125}I$-SA showed above 93% stability in $4^{\circ}C$ until 60days that it is good for immunoradiometric assay as radiotracer. Plotted standard dose response curve showed that increased concentration of rhMIF linearly correlated (R2=0.99) with bound radioactivity of $^{125}I$-SA. The highest intra- and inter-assay coefficients of variation were 5.5% and 7.6%, respectively. The average of recovery of MIF in samples was 102%. In dilution test, linear response curves were obtained (R2=0.97). Conclusion: Radioimmunoassay using $^{125}I$-SA as radiotracer thought to be useful for the determination of serum MIF concentration, and further, its data will be used to evaluate the correlation between clinical significance and serum MIF concentration in patients with various inflammatory diseases.

Multiple Linear Analysis for Generating Parametric Images of Irreversible Radiotracer (비가역 방사성추적자 파라메터 영상을 위한 다중선형분석법)

  • Kim, Su-Jin;Lee, Jae-Sung;Lee, Won-Woo;Kim, Yu-Kyeong;Jang, Sung-June;Son, Kyu-Ri;Kim, Hyo-Cheol;Chung, Jin-Wook;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.317-325
    • /
    • 2007
  • Purpose: Biological parameters can be quantified using dynamic PET data with compartment modeling and Nonlinear Least Square (NLS) estimation. However, the generation of parametric images using the NLS is not appropriate because of the initial value problem and excessive computation time. In irreversible model, Patlak graphical analysis (PGA) has been commonly used as an alternative to the NLS method. In PGA, however, the start time ($t^*$, time where linear phase starts) has to be determined. In this study, we suggest a new Multiple Linear Analysis for irreversible radiotracer (MLAIR) to estimate fluoride bone influx rate (Ki). Methods: $[^{18}F]Fluoride$ dynamic PET scans was acquired for 60 min in three normal mini-pigs. The plasma input curve was derived using blood sampling from the femoral artery. Tissue time-activity curves were measured by drawing region of interests (ROls) on the femur head, vertebra, and muscle. Parametric images of Ki were generated using MLAIR and PGA methods. Result: In ROI analysis, estimated Ki values using MLAIR and PGA method was slightly higher than those of NLS, but the results of MLAIR and PGA were equivalent. Patlak slopes (Ki) were changed with different $t^*$ in low uptake region. Compared with PGA, the quality of parametric image was considerably improved using new method. Conclusion: The results showed that the MLAIR was efficient and robust method for the generation of Ki parametric image from $[^{18}F]Fluoride$ PET. It will be also a good alternative to PGA for the radiotracers with irreversible three compartment model.

Clinical Significance of Bone Scan with $^{99m}Tc-MDP$ in Ankylosing Spondylitis (강직성 척추염에서 $^{99m}Tc-MDP$ 골스캔의 임상적 의의)

  • Kim, Deog-Yoon;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon;Kang, Heung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.87-94
    • /
    • 1991
  • To evaluate the diagnostic usefulness of quantitative sacroiliac joint scintigraphy and its clinical significance in the ankylosing spondylitis, we measured SIS ratio (Sacroiliac Joint/Sacrum Uptake ratio) by region of interest method in 52 patients with ankylosing spondylitis. As compared with radiological grade, SIS ratio was significantly elevated in the early stage of ankylosing spondylitis and returned to normal range in the late stage. Scintigraphic finding of focal uptakes of radiotracer at multiple spinal apophyseal joints was characteristic and proximal large joints were more involved than distal joints. The incidence and extent of the arthropathy revealed by scnitigraphy exceeded that which was clinically evident, and scintigraphy was more sensitive to detect symptomatic lesion than radiography. Therefore, it is suggested that bone scan is useful for the early diagnosis and the assessment of clinical activity of involved joints of ankylosing spondylitis.

  • PDF

$^{18}$F-Fluoride-PET in Skeletal Imaging ($^{18}$F-Fluoride-PET을 이용한 골격계 영상)

  • Jeon, Tae-Joo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.253-258
    • /
    • 2009
  • Bone scintigraphy using $^{99m}$Tc-labeled phosphate agents has long been the standard evaluation method for whole skeletal system. However, recent shortage of $^{99m}$Tc supply and advanced positron emission tomography (PET) technology evoked the attention to surrogate radiopharmaceuticals and imaging modalities for bone. Actually, fluorine-18 ($^{18}$F) was the first bone seeking radiotracer before the introduction of $^{99m}$Tc-labeled agents even though its clinical application failed to become pervasive anymore after the rapid spread of Anger type gamma camera systems in early 1970s. However, rapidly developed PET technology made us refocus on the usefulness of $^{18}$F as a PET tracer. Early study comparing $^{18}$F-Na PET scan and planar bone scintigraphy reported that PET has higher sensitivity and specificity in the diagnosis of metastatic bone lesions than planar bone scan. Subsequent reports comparing between PET and both planar and SPECT bone image also revealed better results of PET scan in similar study groups. Rapid clinical application of PET/CT also accumulated considerable amount of experiences in skeletal evaluation and this modality is known to have better diagnostic power than stand alone PET system as well as bone scan. Furthermore $^{18}$F-Na PET/CT revealed better or at least equal results in detection of primary and metastatic bone lesions compared with CT and MRI. Therefore, it is obvious that $^{18}$F-Na PET/CT has potential to become new imaging modality for practical skeletal evaluation so continuous and careful evaluation of this modality and radiopharmaceutical must be required.

Synthesis and Small Animal Brain PET Study of a Serotonin Receptor Radiotracer, 18F-Mefway (세로토닌 5-HT1A수용체 방사성 추적자 18F-Mefway의 합성과 소동물 뇌 PET 연구)

  • Ahn, Sung-Min;Hong, Tae-Kee;Ryu, Young-Hoon;Choi, Jae-Yong;Kim, Sung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.262-270
    • /
    • 2009
  • $^{18}F$-mefway has been developed as radioligand for serotonin receptor 5-$HT_{1A}$. The object of this study was to obtain the mefway precursor with the higher yield than previous method and to identify whether $^{18}F$-mefway can bind to 5-$HT_{1A}$ or not. from microPET imaging of small animal brain. Precursor was prepared by a modification of the reported procedure then [$^{18}F$] labeling was performed by adding $^{18}F$ ion at $130^{\circ}C$ in the hot cell for 30min. After purification of reaction mixture using alumina Sep-pak and HPLC, microPET images of small animal brain were determined. The chemical yield of precursor was increased from 9% to 34% using oxalyl chloride and LAH/diethylether. We synthesized a precursor which was successfully labeled with no-carrier-added $^{18}F$-by new synthetic route. This research suggest that $^{18}F$-mefway will be used a radiopharmaceutical for evaluation of central nerve system disorder as imaging a gent for 5-$HT_{1A}$ receptor.

Diagnosis of fibroadenoma using radiolabeled bladder cancer specific peptide

  • Ha, Yeong Su;Kwak, Wonjung;Lee, Hwa Young;Lee, Byung-Heon;Hong, Il-Hwa;Jeong, Kyu-Shik;An, Gwang Il;Yoo, Jeongsoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.1
    • /
    • pp.38-45
    • /
    • 2015
  • Most tumors are believed to overexpress several receptors, and small peptides targeting these receptors were developed for diagnosis and tumor therapy during past decade. Here we report that fibroadenoma can be visualized by bladder cancer specific peptide. A 9-mer bladder cancer specific peptide, which was discovered from the phage display method, was synthesized by peptide synthesizer, and additional tyrosine was conjugated at the N-terminal for radioiodination (Y-BP). Y-BP was radiolabeled with $^{131/124}I$ using Iodogen tube. The rat treated with N-butyl-N-(4-hydroxybutyl)nitrosamine for 8 weeks was allowed to grow until large size tumor was developed under axilla. The tumor model was microPET imaged sequentially using [$^{18}F$]FDG and radioiodinated $^{124}I-Y-BP$. The tumor was excised and examined by immunostaining studies. Radioiodinated $^{124}I-Y-BP$ was purified using fast protein liquid chromatography (FPLC) in > 90% radiochemical purity. The whole tumor was well visualized by [$^{18}F$]FDG with several intense focal uptake within tumor. The tumor was also clearly seen with $^{124}I-Y-BP$ at 4 h post-injection, and to our surprise the tumor uptake of $^{124}I-Y-BP$ lasted up to three days. The tumor was diagnosed histologically as a fibroadenoma derived from mammary gland. In conclusion, the bladder cancer specific peptide showed the good potential as a new radiotracer for the detection of breast fibroadenoma.

$^{99m}Tc$ Labeling Kit Preparation and Characteristics of Anti-NCA-95 Monoclonal Antibody (항 NCA-95 단일클론항체의 $^{99m}Tc$표지 키트 제조 및 특성 연구)

  • Hong, Mee-Kyoung;Jeong, Jae-Min;Chung, June-Key;Choi, Seok-Rye;Kim, Chae-Kyun;Lee, Yong-Jin;Lee, Dong-Soo;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.541-547
    • /
    • 1996
  • The previous monoclonal antibody labeling method for bone marrow immunoscintigrapy was complicated and laborious for clinical application. Also it showed a relatively low labeling efficiency. To improve this procedure, we compared several direct labeling methods of $^{99m}Tc$. 1) The labeling efficiency in the method using gluconate as a transchelator was low (40-70%), but immunoscintigraphy using this radiotracer produced a clear image. 2) To improve labeling efficiency, ${\beta}$-mercaptoethanol was removed after reduction. The labeling efficiency was improved up to 70-80%, but the radioactivity of the blood pool was high. 3) The higest labeling efficiency (>90%) and best quality images could be obtained by using MDP as a transchelating agent. It did not require additional procedures for separation of labeled antibodies. The immunoreactivity of this antibody was 60%. Residual MDP which can be taken up by the bone could be removed by PD-10 column. The reduced antibodies were stable with a high labeling efficiency (>90%) for up to 47 days by deep freezing. We concluded that the improved procedure for $^{99m}Tc$ labeling of anti-NCA-95 monoclonal antibody using MDP as a transchelating agent will be a simple and useful method for clinical application.

  • PDF

Evaluation of Myocardial Oxygen Consumption with $^{11}C$-Acetate and 3D PET/CT: By Applying Recirculation Correction Method and Modified One-Compartmental Tracer Kinetic Modeling ($^{11}C$-Acetate와 3차원 PET/CT를 이용한 심근의 산소 소모량 평가: 재순환 교정법 및 수정 단일구획 추적자 동적 모델 적용)

  • Chun, In-Kook;Hwang, Kyung-Hoon;Lee, Sang-Yoon;Kim, Jin-Su;Lee, Jae-Sung;Shin, Hee-Won;Lee, Min-Kyung;Yoon, Min-Ki;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.275-284
    • /
    • 2008
  • Purpose: We intended to evaluate myocardial oxygen consumption ($MVO_2)$ by applying recirculation correction and modified one-compartment model to have a reference range of $MVO_2$ in normal young population and to reveal the effect of recirculation on time-activity curve (TAC). Materials and Methods: In nine normal male volunteers with mean age of $26.3{\pm}4.0$, $MVO_2$ was estimated with 925 MBq (25mCi) of $^{11}C$-Acetate (Neuroscience Research Institute, Gachon University of Medicine and Science, Incheon, Korea) and PET/CT (Biograph 6, Siemens Medical Solution, Germany). Analysis software such as $MATLAB^{(R)}$ v7.1 (Mathworks, Inc., United States), $Excel^{(R)}$ 2007 (Microsoft, United States), and $SPSS^{(R)}$ v12.0 (Apache Software Foundation, United States) were used. Twenty three frames were of $12{\times}10$, $5{\times}60$, $3{\times}120$, $2{\times}300's$ duration, respectively. The modified one-compartmental model and the recirculation correction method were applied. Statistical analysis was performed by using Test of Normality, ANOVA and Post-Hoc (Scheffe's) analysis, and p-value less than 0.05 was considered as significant. Results: The normal reference ranges of $MVO_2$ were presented as $3.18-4.64\;{\times}\;10^{-4}\;ml/g/sec$, $1.91-3.94\;{\times}\;10^{-4}\;ml/g/sec$, $4.31-6.40\;{\times}\;10^{-4}\;ml/g/sec$, $2.84-4.53\;{\times}\;10^{-4}\;ml/g/sec$ and $3.42-5.00\;{\times}\;10^{-4}\;ml/g/sec$ in the septum, the inferior wall, the lateral wall, the anterior wall and the entire wall, respectively. In addition, it was noted that the dual exponentiality of the clearance curve is due to the recirculation effect and that the characteristic of the curve is essentially mono-exponential. Conclusion: $^{11}C$-Acetate is a radiotracer worthwhile to assess $MVO_2$. Re-circulated $^{11}C$ can influence TAC of $^{11}C$ in myocadia and so the recirculation correction must be considered when measuring $MVO_2$.