• 제목/요약/키워드: radiological finding

검색결과 133건 처리시간 0.036초

척수내 종양과 감별을 요하는 비종양성 척수증 : 수술로 확진된 8례의 후향적 분석 (Non-neoplastic Myelopathies Mimicking Intramedullary Spinal Cord Tumors : Retrospective Analysis of 8 Surgically Proven Cases)

  • 김기정;정천기;심기범;김현집
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권7호
    • /
    • pp.891-898
    • /
    • 2000
  • Objective : It is difficult to differentiate intramedullary spinal cord tumors preoperatively from non-neoplastic pathologies in patients presenting as non-compressive myelopathies in magnetic resonance imaging(MRI). In this report, the authors reviewed nonneoplastic intramedullary spinal cord lesions preoperatively diagnosed as tumors and discussed their clinical and radiological characteristics and usefulness of surgical intervention. Methods : From January, 1985 to January, 1999, authors experienced eight non-neoplastic pathologies mimicking intramedullary spinal cord tumors and analysed their medical records, radiological findings and histopathological specimens retrospectively. Results : There were five males and three females and the duration of symptoms were from two to 20 months(mean, 9.8 months). The location of lesions were four cervical, one cervicothoracic and three thoracic. All patients manifested sensory abnormality, seven motor weakness, and six bladder symptom. All cases had swollen spinal cords and increased signal intensities in spin-echo sequences. Six cases showed contrast enhancement : four cases were focal and two diffuse. Under the impression of intramedullary tumors, the patients were operated upon. Final diagnoses on the base of clinical and pathologic finding were : three subacute necrotizing myelopathies, two multiple scleroses, two myelopathy of unknown etiology. One case showed no gross abnormality in surgical field in spite of adequate exposure of the lesion, so biopsy was not performed. In that case, postoperative MRI revealed spontaneous resolution of the lesion. Conclusion : MRI is invaluable diagnostic tool in screening myelopathies. However, its high sensitivity and lack of specificity make difficulty in preoperative differential diagnosis of non-compressive myelopathies. Although no surgical morbidity occurred in our series, we sometimes failed to confirm definite diagnosis even with biopsy. In such a circumstance, long-term follow up is needed.

  • PDF

흉부(胸部) X선촬영시(線撮影時) 부가여과사용(附加濾過使用)에 따른 선양(線量)과 선질(線質)에 관(關)한 연구(硏究) (A Study of Radiation Dose and Quality by Using Added Filtration in Chest Radiography)

  • 유병헌;추성실;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제10권1호
    • /
    • pp.13-23
    • /
    • 1987
  • Author has studied for finding the method of decreasing the radiation dose and increasing diagnostic range in chest X-ray radiography. The study for the added filter thickness from half value layer to 1/8 value layer by decreasing curve and research for the exposure factors, decreasing ratio of radiation dose, ratio of scatter ray and image quality in chest X-ray radiography. The results were as follows: 1. By using the rare earth intensifying screen system at 120 Kvp, the sensitivity is increased by times and the exposure ratio is decreased 0.22 by comparison with the $CaWO_{4}$ intensifying screen system at 80 Kvp. 2. By using Al added filter of 1/8 value layer, the scatter ray is increased more than no filter, But the scatter ray is decreased more in $G_{4}/RxOG$ intensifying system than in LT-II/Rx intensifying system. 3. At 120 Kvp, the image quality value of $G_{4}/RxOG$ system is increased more than LT-II/Rx system compared with slight decreasing image quality value at 80 Kvp. Concluded that by using the added filter could decrease the radiation dose by 1/3 and obtain effective image quality with the added filter at high voltage hard exposure.

  • PDF

골단일 형질세포종 : 방사선학적 소견 (Solitary Plasmacytoma of the Bone: Radiologic Findings)

  • 윤춘식;김명준;안창수;서진석;신규호
    • 대한골관절종양학회지
    • /
    • 제6권2호
    • /
    • pp.61-68
    • /
    • 2000
  • 목적 : 골단일 형질세포종의 방사선 소견을 알아보고자 하였다. 대상 및 방법 : 최근 5년동안 골단일 형질세포종으로 진단받았던 9례의 방사선 소견을 후향적으로 검토하였다. 이 중 2례는 골수검사 소견의 이상으로 대상에서 제외되었고 다른 2례는 전산화단층촬영(1례)와 자기공명영상(1례) 소견의 이상 소견에 의해 대상에서 제외되었다. 결과 : 5례 중 4례에서 단순방사선검사상 경화성 변연이 없는 지도 모양의 골파괴 소견을 보였으며 대퇴골에서 발생한 1예는 골경화증 병변을 보였다. 전산화단층촬영과 자기공명영상 검사는 단순방사선검사에 비해 소주형성을 한 골파괴와 연부조직 침범 등 보다 많은 정보를 보여주었다. 4례의 자기공명영상에서 T 1강조영상에서는 비교적 고신호강도, T2강조영상에서 는 근육보다 약간 높은 중등도 신호강도를 보여주었다. 1례에서는 광범위한 연부조직 침범이 있었고, T1강조영상에서 같거나 저신호강도로, T2강조영상에서는 비균일한 고신호강도를 보이는 다발성 괴사가 있었다. 조영증상 T 1강조영상에서는 괴사부위를 제외한 병변의 강한 조영증강소견이 보였다. 결론 : 전산화단층촬영과 자기공명영상 검사는 골단일 형질세포종의 특징적인 소견의 일부를 보여줄 수 있고 형질세포 침윤이 있는 다른 부위를 찾을 수 있다. 이러한 것들이 골단일 형질세포종의 진단과 치료에 도움을 줄 수 있을 것이다.

  • PDF

소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 - (Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography -)

  • 이희정;손순룡;이원홍
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권4호
    • /
    • pp.279-286
    • /
    • 2005
  • 목 적 : 소장조영술과 복부골반 CT검사의 진단 결과를 비교함으로써 방사선학적 영상의 특징 파악 및 질환에 따른 적절한 방사선학적 검사법을 선택하는데 기초자료를 제공하고자 한다. 대상 및 방법 : 1999년부터 2000년까지 소장조영술과 복부골반 CT검사를 병행하여 시행한 환자 284명을 대상으로 하여, 각각의 진단 소견을 병명별로 분류하였다. 소장조영술은 250 ml 황산바륨 현탁액(W/V 40W/V%, Methylcellulose+$BaSo_4$)을 경구로 복용시키고, Rt. recumbent position을 취하게 한 후 약 10분 후에 Carboxymethylcellulose solution(0.5%) 600 ml 복용시켰다. 20분, 40분, 1시간 정규촬영을 하고, 조영제가 회맹판(I-C valve)을 통과하면 투시 하에 저격촬영을 시행하였다. 복부골반전산화단층촬영은 검사 1시간 전에 $BaSO_4$+Methylcellulose 1.5 W/V% 450 ml를 복용시키고 검사직전 450 ml 추가로 복용시켰다. 요오드 성분의 비이온성 조영제 2.5 ml flow/sec로 주입하고, 조영제 주입 후 72초 지연 촬영을 하였다. 촬영은 간 상연에서부터 치골결합 부위까지 continuous scan을 시행하였으며, 검사 protocol은 Helical thick 5 mm, picth 1.375 : 1, speed 27.50, increment 5 mm, 120 kV, 245 mA로 하였다. 결 과 : 소장조영술에서는 정상(Normal)이 131예(46.1%), 감염성 장질환(Inflammatory bowel disease ; 이하 IBS)이 65예(22.9%), ischemia+ileocolitis+vasculitis 22예(7.7%), obstruction+stricture 21예(7.4%)의 순으로 나타났고, 복부골반 CT검사에서는 정상이 103예(36.3%) IBS가 65예(22.9%), wall thickening+lymphadenopathy가 42예(14.8%), fluid collection이 17예(6%)의 순으로 나타났다. 소장조영술과 복부골반 CT검사에서 동일하지 않은 결과로 진단된 경우는 소장조영술에서 정상으로 진단된 132명(46.1%) 중 14예(10.6%), 복부골반 CT검사 결과에서는 wall thickening+lymphadenopathy와 IBS로 진단되어 차이를 보였으며, 복부골반 CT검사 결과 정상으로 진단된 103예(36.3%) 중 5예(5.8%)가 소장조영술에서 ischemia+ileocolitis+vasculitis로 진단되었다. 정상으로 진단 된 235예 중 37예(15.9%)가 서로 다른 결과로 진단되어 통계적으로 유의한 차이를 보였다(P<0.05). 결 론 : 본 연구에서 특정질환에 특정검사의 진단결과가 우수하게 나타나는 것으로 조사되었으므로 방사선학적 검사의 진단적 민감도를 높이기 위해서는 처방 및 검사에 있어서 질환에 따른 적절한 검사법의 선택이 무엇보다도 중요하리라 사료된다.

  • PDF

요추 전만 각도와 요추 추간판 탈출증의 상관성 분석 (A Relationship Study of Lumbar Lordortic Angle and Herniation of Intervertebral Disc)

  • 전재윤;이준석;이슬지;남지환;이민정;김기원;임수진;송주현;문자영;염승철;이성철
    • 척추신경추나의학회지
    • /
    • 제7권2호
    • /
    • pp.83-90
    • /
    • 2012
  • Objectives : The perpose of this study was to observe the correlation between lumbar lordotic angle and radiological result. Methods : We randomly selected among the 150 patients with lumbar X-ray and MRI films who have visited Jaseng Hospital of Oriental Medicine with low back pain. Radiographic lumbar lordotic angle and lumbar HIVD were collected and stastically analyzed. Results : In this study, if the finding of a X-ray showed straightening of lumbar lordotic curve, based on MRI finding, the number of HIVD increased. Conclusions : There was a significant correlation between lumbar hypolordosis and HIVD, hypolordosis complained mare HIDVs.

  • PDF

생체 흡수성 판과 나사못을 이용한 족근 관절 골절의 치료 (Fixation with Bioabsorbable Polylactide Plate and Screws for the Treatment of the Ankle Fractures)

  • 권덕주;이용범;신준
    • 대한족부족관절학회지
    • /
    • 제13권1호
    • /
    • pp.80-84
    • /
    • 2009
  • Purpose: The purpose of this article is to assess the efficacy of a bioabsorbable polylactide (PLA) plate and screw for treating injuries of ankle fractures. Materials and Methods: 24 patients who underwent an open reduction and internal fixation operation for ankle fractures from July 2005 to March 2007 were enrolled into the study. There were 15 men and 9 women. The average age of the patients was 44 years and the average follow-up period was 16 years and two months (16.2 months). All cases were divided into low grade fracture patient (11) who belongs in type A and B of Danis-Weber classification and high grade fracture patient (13) who belongs in type C1, C2 of Danis-Weber classification, and each groups were analyzed by clinical (Meyer score) and radiological finding at the time of their last follow-up evaluation. Results: The clinical results according to Meyer scoring system, showed that all patient with low grade fracture had good to excellent result, but only 54% of patient with high grade fracture had good to excellent result. According to Cedell's radiologic finding, there were 91% cases above fair in low grade fracture. But there were 62% of patient above fair result in high grade fracture, the reduction losses were seen in 38% of patient with high grade fracture. Conclusion: Bioabsorbable PLA plate and screw is good internal fixation device which doesn't have additional operation for removal of implant because of slow absorption within the human body. It showed sufficient strength for acquisition and maintenance of reduction in low grade fracture, but need attention to use because of many cases of reduction loss in high grade fracture. So, it seems to be safe and effective when used in heeling of low grade fracture under considering about type of fracture sufficiently.

  • PDF

Computed Tomographic Angiography (CTA)의 검사 시 조영제 집적 정점시간에 영향을 미치는 특성 인자를 분석 (Analysis of Factors Influencing the Integrated Bolus Peak Timing in Contrast-Enhanced Brain Computed Tomographic Angiography)

  • 손순룡;최관우;정회원;장서구;정재용;윤정수;김기원;이영아;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.59-69
    • /
    • 2016
  • Computed tomographic angiography (CTA)의 (조영제 집적 정점시간에 영향을 미치는 특성 인자를 분석하여: analyzing factors influencing on the integrated bolus peak timing in contrast-enhanced) 개인별 정점 시간을 계량적(Systems analysis)으로 산정해 검사에 직접 적용함으로써 예비검사(monitoring scan)에 의한 불필요한 방사선 피폭을 예방하는데 목적이 있다. CTA의 예비검사(monitoring scan)을 통해 얻은 조영제 집적 정점시간과 개인별 측정치들 간의 상관관계분석을 통해 영향인자를 파악한 다음, 다중선형회귀분석에 의한 회귀식으로 적정시간을 산출하였다. 결과로는 CTA의 평균 방사선 노출량은 $716.53mGy{\cdot}cm$였고, 예비검사(monitoring scan) 15.52 mGy (2 ~ 34 mGy)로 나타났다. 장기별 변환요소(conversion factor)를 적용한 결과, 전체 선량은 평균 1.5 mSv였고, 예비검사 선량은 0.23 mSv로 나타났다. 특성인자의 측정치와 조영제 정점시간의 상관관계분석 결과, 남성은 심박동수에서, 여성은 심박동수와 최저혈압, 혈당에서 음의 상관관계를 보였으며, 통계적으로 매우 유의하였다(p<.01). 회귀분석결과, 남성은 심박동수가 한 단계 증가할 때마다 -0.160배로, 여성은 최저혈압과 심박동수, 혈당에 따라 각각 -0.004, -0.174, -0.006배로 유의하게 감소하였다. 실측한 조영제 정점시간과 회귀식에 의해 산출된 정점시간의 일치도 검사에서 남여 대상자 모두에서 일치도가 매우 높았다. 본 연구에서는 검사 전에 환자 개인별 조영제 집적 정점시간을 산정하여 적용하면 예비검사를 생략함으로써 불필요한 방사선피폭을 예방할 수 있을 것으로 사료된다.

고감도 MOSFET 선량계 방사선학적 특성 연구 (Radiological Characterization of the High-sensitivity MOSFET Dosimeter)

  • 조성구;김찬형
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.215-219
    • /
    • 2004
  • MOSFET 선량계는 기존의 선량계들에 비해 여러 가지 장점이 있기 때문에 최근에 방사선 치료뿐만 아니라 방사선 진단 등 기타 여러 분야에서 선량검증을 위해 시도되고 있다. 하지만 이렇게 사용되기 위해서는 중ㆍ저에너지 범위의 광자선에 대한 MOSFET 선량계의 방사선학적 특성파악이 선행되어야 한다. 본 연구에서는 고감도 MOSFET 선량계의 여러가지 방사선학적 특성을 자세하게 연구할 수 있는 3차원 몬테칼로 전산모사 모델을 개발하였다. 고감도 MOSFET 선량계의 검출부위는 매우 얇아서 MCNP에서 기본적으로 제공하는 Tally를 사용하면 검출부위에 흡수된 에너지를 정확하게 결정할 수 없으므로 검출부위에 주어진 에너지를 전자들의 트랙들로부터 직접 계산하는 방법을 채택하였다. 개발된 모델은 에너지 의존도, 전자 기여도, 깊이 의존도 등의 MOSFET 선량계의 방사선학적 특성을 연구하기 위해 사용되었다. 에너지 의존도는 15 keV에서 6 MeV 에너지 범위에서 정량화하였는데 약 40 keV에서 최대 6.6으로 나타났다. 본 연구에서는 PTRAC 파일과 Sabrina 코드를 이용하여 MOSFET 선량계 각 부분에서의 전자 기여도를 조사하였다. 깊이 의존도는 신체 내 평균 깊이를 15 cm로 가정할 때 0.662 MeV의 경우는 교정인자 1.16 그리고 1.25 MeV의 경우는 교정인자 1.11을 사용하여 깊이 의존도에 의한 오차를 줄일 수 있다.

  • PDF

폐결핵으로 오인된 폐방선균증의 수술적 치험 1례 (Surgical Treatment of Pulmonary Actinomycosis Mimicking Pulmonary tuberculosis)

  • 백효채;이진구;강정한;정경영;구자승
    • Journal of Chest Surgery
    • /
    • 제35권4호
    • /
    • pp.315-317
    • /
    • 2002
  • 방선균증이 폐를 침범하여 수술을 시행하는 경우는 매우 드물며 본 저자들은 반복적인 객혈을 주소로 내원한 남자 환자에서 폐결핵 의심하에 폐절제 수술을 하였으며 병리소견상 폐 방선균증으로 진단되었기에 보고한다. 환자는 49세 남자로 내원 전 임상증상과 단순 흉부 촬영에서 폐결핵으로 진단 후 결핵약을 복용 중이었으나 지속적인 결핵약 복용에도 증상의 호전이 없고 단순 흉부 촬영 및 흉부 컴퓨터 촬영 상 좌폐 상엽에 동공 형성을 보여 결핵약에 반응을 보이지 않는 폐결핵으로 의심하고 외과적 절제술을 시행하였다. 외과적 절제술 후 병리조직학적 검사 상 sulfur granule을 확인하여 방선균증을 진단하였다. 환자는 수술 후 문제없이 퇴원하여 6개월간 항생제 치료를 받을 예정이다.

대공부와 상위경추부 종양에 대한 수술적 치료 (Surgical Treatment of Foramen Magnum & High Cervical Spinal Cord Tumor)

  • 윤도흠;오성한;조용은;진병호;진동규;김영수
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권4호
    • /
    • pp.463-471
    • /
    • 2001
  • Objective : The authors reviewed 51 patients of spinal cord tumor located at the craniovertebral junction and high cervical area to determine which factors influenced resectability, complications, and postoperative outcomes. Methods : Radiological examinations, clinical data, and operation notes were evaluated, and additional follow-up information was obtained from outpatient examinations. The mean follow-up period was 3.5 years Results : The most common neurological findings were motor deficit(72.5%) and sensory change(47.1%). There was no clinical finding that is considered as pathognomic. Meningioma(18 cases, 35.3%) was the most common tumor in this region. Total removal was achieved in 45 patients. There was no surgical mortality. Immediate postoperative motor weakness were encounted in 11 cases(21.6%) which improved in long term followup except two patients. Conclusions : The location and relationship of the tumor to surrounding struncture determine its resectability. Postoperative results were related to the preoperative neurological status and pathological findings.

  • PDF