• Title/Summary/Keyword: radiographic measurements

Search Result 130, Processing Time 0.023 seconds

Evaluation of Image Quality for Radiographic Positioning using IEC Radiation Quality in the Digital Radiography System (디지털방사선시스템에서 IEC표준을 이용한 방사선 영상 품질의 평가)

  • An, Hyeon;Kim, Changsoo;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.289-299
    • /
    • 2015
  • The purpose of this study is to evaluate and compare the quality of digital X-ray imaging system. The image quality evaluation was conducted By using Modulation transfer function indicating the quantitative resolution of the image and the noise power spectrum showing the noise characteristics. Using a IEC61267 radiation quality was applied to the geometry to be used in clinical and geometry presented in IEC62220-1 and Additional filter, grid, the clinical dose and the MTF value of edge phantom was measured. Result of the MTF corresponding to each item(Grid, Filter, SID, kVp, mAs), the clinical condition 100cm, 180cm, measurements of the spatial frequency of the MTF IEC62220-1Geometry 150cm became similarly apparent, rather spatial frequency was also the case high in clinical conditions 100cm. NPS results, as the dose(mAs) is increased, NPS showed that reduced. The image quality evaluation using IEC61267 the Radiation quality, Image quality of the video using the clinical conditions Geometry than image quality evaluation using IEC62220-1Geometry was better. It shows that MTF and NPC in IEC and clinical condition were not significantly different. In order to apply the evaluation method of image quality applied with clinical conditions rather than the future method, to be presented evaluation of IEC standard, based on the results of the image characterization studies in this paper, the methods that shows good quality of spatial resolution and decrease NPS value as the least dose, used suitable parameters for whether or not using added filter, grid, change SID and clinical quality(kVp), dose(mAs) etc should be found. then It is believed to be able to properly maintain the actual quality of the image of the digital radiographic imaging system in clinical.

An 1 year prospective comparative study evaluating the effect of microthread on the maintenance of marginal bone level (임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구)

  • Shin, Dong-Hwan;Cho, Kyoo-Sung;Park, Kwang-Ho;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.349-358
    • /
    • 2003
  • The success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, $M{\"{o}}lndal$, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread($Microthread^{TM}$) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226${\pm}$0.395mm, while ATTB was 0.440${\pm}$0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269${\pm}$0.265mm for ATST and 0.529${\pm}$0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167${\pm}$0.231mm and 0.313${\pm}$0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread ($Microthread^{TM}$) was effective to maintenance of marginal bone level around fixture.

Retrospective radiographic and clinical analysis of implant survival placed after alveolar ridge preservation (발치와 치조제 보존술 시행 후 식립한 임플란트의 방사선학적 및 임상적 후향적 연구)

  • Lee, Sung-Jo;Jang, Hyun;Shin, Hyun-Seung;Park, Jung-Chul;Song, Young-Gyun;Cho, In-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.167-174
    • /
    • 2018
  • Purpose: The purpose of present study was to retrospectively analyze the survival rate of implant placed after alveolar ridge preservation by initial stability and radiographic measurements. Materials and Methods: In total, 19 patients who received 21 sandblasted, large-grit, acid-etched (SLA) implants were enrolled in this retrospective study. Implants placed after alveolar ridge preservation technique (ARP) 2 - 3 months healing period, Periotest value (PTV) measured at implant placement and before placed prosthodontics. Marginal bone level (MBL) was measured at implant placement and final recall check. Results: Overall survival rate of implant was 100%. Mean PTV at implant placement was $-0.06{\pm}8.33$ and mean PTV before placed prosthodontics was $-5.75{\pm}1.7$. The range of MBL change was from -0.55 mm to 1.6 mm (Mean: $0.19{\pm}0.58mm$). Conclusion: The findings of present study suggest that the implant paced after alveolar ridge preservation appear high survival rates and stable MBL.

Patient exposure doses from medical x-ray examinations in Korea (진단방사선검사에서 환자피폭선량에 관한 연구)

  • Kim, You-Hyun;Choi, Jong-Hak;Kim, Sung-Soo;Oh, Yuw-Han;Lee, Chan-Hyeup;Cho, Pyong-Kon;Kang, Dae-Hyun;Lee, Young-Bae;Kim, Hyung-Chul;Kim, Chel-Min
    • Journal of radiological science and technology
    • /
    • v.28 no.3
    • /
    • pp.241-248
    • /
    • 2005
  • X-ray examinations represent the largest man-made source of radiation exposure for the population. The need for standardization of radiation exposures has been suggested and the guidance levels for various radiographic and radioisotope examinations has been proposed by the International Atomic Energy Aency(IAEA) as a safety standard. In many countries, the situation of medical radiographic exposures in each country should be researched before the appropriate guidance level is established. In this study, measurements of entrance surface dose, dose-area product(DAP), computed tomograghic dose index(CTDI) and mean glandular dose(MGD) were carried out in patients who underwent routine x-ray examinations, fluoroscopy, computed tomograghy and mamography in Korea. These measured quantities were compared with the results from the calculation method in previous study. And we suggested diagnostic reference levels in medical imaging in Korea.

  • PDF

Radiographic Study of Cobey Method and Modified Cobey Method (Cobey 검사법과 Modified Cobey 검사법에 대한 방사선학적 연구)

  • Go, Yu-Rim;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.167-173
    • /
    • 2019
  • The Cobey method and the modified Cobey method are most commonly used in clinical practice. Therefore, the purpose of this study was to investigate the radiological differences between Cobey and modified Cobey and provide radiographic information about changes of hindfoot image with X-ray entrance center and tube angle change in modified Cobey. This study was performed on foot and ankle phantom. First, for image comparison of Cobey and modified Cobey, the images obtained by applying the same X-ray entrance center to the ankle joint were compared and analyzed. Second, in the modified Cobey, the X-ray entrance center is set as ankle joint and lateral malleolus. The X-ray tube angle was varied from $10^{\circ}$ to $40^{\circ}$ at $5^{\circ}$ intervals for each X-ray entrance center. The images obtained by varying the X-ray tube angle from $10^{\circ}$ to $40^{\circ}$ at intervals of $5^{\circ}$ for each X-ray entrance center were compared and analyzed. The irradiation conditions were the same with 110 kVp, 200 mA, 10 ms, and 110 cm of source - image receptor distance (SID). Image evaluation was performed by two radiologists. Measurements were made on the lateral point, middle point, and calcaneus width based on a hypothetical line parallel to the calcaneal tuberosity. Data were analyzed by using descriptive statistics as the mean of the distance to each measurement location. The modified Cobey was longer than the Cobey by an average of 3 to 4 mm lateral and medial points, and the calcaneus width was similar (ICC = 0.939). In modified Cobey method, when the X-ray entrance center is ankle joint, the lateral point is about 3 mm and the medial point is about 4.3 mm longer than lateral malleolus. Also, when the X-ray tube angle is more than $20^{\circ}$, the degree of distortion is large. The ICCs for the lateral, medial point, and calcaneus width were 0.998, 0.961, and 0.997, respectively, as the X-ray entrance center and tube angle were changed. There was no significant difference between Modified Cobey and Cobey. Modified Cobey showed no need to compensate the $20^{\circ}$ detector angle of the Cobey. In addition, we suggest that tube angle should be limited within $20^{\circ}$ when modified Cobey is performed.

Comparative Study of the Early Loading of Resorbable Blasting Media and Sandblasting with Large-grit and Acid-etching Surface Implants: A Retrospective Cohort Study

  • Kim, Sung-Beom;Kim, Young-Kyun;Kim, Su-Gwan;Oh, Ji-Su;Kim, Byung-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.6
    • /
    • pp.247-252
    • /
    • 2014
  • Purpose: This study compares the prognosis (the survival rate and marginal bone loss) of resorbable blasting media (RBM) surface implants and sandblasting with large-grit and acid-etching (SLA) surface implants in the early loading. Methods: This study targeted 123 patients treated by implants installation from January 2008 to March 2010. The loading was initiated in the maxilla within three to four months and in the mandible within one to two months. The types of restoration were single crown and fixed partial prosthesis. Those functioned over one year. The implants were classified by the surface of implants as Group 1: RBM surface (GS III; OSSTEM, Busan, Korea) and, Group 2: SLA surface (Superline; Dentium, Seoul, Korea). The groups were categorized by maxilla and mandible and compared by survival rate, marginal bone loss through clinical records evaluation, and radiographic measurements. Results: The marginal bone loss in the maxilla was $0.14{\pm}0.34mm$ (Group 1) and $0.30{\pm}0.37mm$ (Group 2), a statistically significant difference (P<0.05). In the mandible those were $0.28{\pm}0.54mm$ (Group 1) and $0.20{\pm}0.33mm$ (Group 2), not significant (P>0.05). There was no significant difference of marginal bone loss between maxilla and mandible by groups. During observation there was no implant failure, a survival rate of 100%. Conclusion: Both surfaces showed an excellent survival rate, and the marginal bone loss was not substantial.

Single Dorsal Incision Technic for Hallux Valgus Surgery (단배부 절개를 이용한 무지 외반증 수술)

  • Song, Kyung-Won;Park, In-Heon;Kim, Gab-Lae;Lee, Seung-Yong;Hyun, Youn-Seok;Seo, Eun-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.35-38
    • /
    • 2007
  • Purpose: In this study, we introduced a newly developed technique of operation for hallux valgus. We used a single dorsal incision to correct major components of Bunion in stead of two or three incisions, which had been used by most of surgeons for long time. Materials and Methods: Between 2003 and 2005, 27 feet with hallux valgus deformity were operated through single dorsal incision. 10 out of 17 patients underwent operation on both feet, 5 patient underwent operation on left feet, remaining 2 underwent operation on right. There were 16 women and 1 man. Average age of patients was 45 (range, 21-59). Post operatively all feet were evaluated by physical examination, Maryland Foot score profile, radiographic measurements and complication. Results: Maryland foot score profile increased from preoperative 67/100 to postoperative 95/100. Most patients satisfied pain relieve and cosmesis. Average preoperative intermetatarsal angle was 15 degrees, which were decreased to 9 degrees after operation and average preoperative hallux valgus angle was 32 degrees, which were decreased to 12 degrees after operation. Conclusion: According to our experience, the single dorsal incision technic for correction of moderate to severe hallux valgus deformities was rather safe and easily performed without noticeable complication with almost same results as multiple incisions technics. We highly recommend this technic to be tried by foot surgeons without hesitation.

  • PDF

The Properties of Beam Intensity Scanner(BInS) in IMRT with Phantom for Three Dimensional Dose Verification

  • Young W. Vahc;Park, Kwangyl;Byung Y. Yi;Park, Kyung R.;Lee, Jong Y.;Ohyun Kwon;Park, Kwangyl;Kim, Keun M.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.64-64
    • /
    • 2003
  • Objectives: Patient dose verification is clinically the most important parts in the treatment delivery of radiation therapy. The three dimensional(3D) reconstruction of dose distribution delivered to target volume helps to verify patient dose and determine the physical characteristics of beams used in intensity modulated radiation therapy(IMRT). We present Beam Intensity Scanner(BInS) system for the pre treatment dosimetric verification of two dimensional photon intensity. The BInS is a radiation detector with a custom made software for relative dose conversion of fluorescence signals from scintillator. Methods: This scintillator is fabricated by phosphor Gadolinium Oxysulphide and is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The digitized fluoroscopic signals obtained by digital video camera will be processed by our custom made software to reproduce 3D relative dose distribution. For the intensity modulated beam(IMB), the BInS calculates absorbed dose in absolute beam fluence, which are used for the patient dose distribution. Results: Using BInS, we performed various measurements related to IMRT and found the followings: (1) The 3D dose profiles of the IMBs measured by the BInS demonstrate good agreement with radiographic film, pin type ionization chamber and Monte Carlo simulation. (2) The delivered beam intensity is altered by the mechanical and dosimetric properties of the collimating of dynamic and/or static MLC system. This is mostly due to leaf transmission, leaf penumbra, scattered photons from the round edges of leaves, and geometry of leaf. (3) The delivered dose depends on the operational detail of how to make multileaf opening. Conclusions: These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planing for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

Anti-Platelet Drug Resistance in the Prediction of Thromboembolic Complications after Neurointervention

  • Ryu, Dal-Sung;Hong, Chang-Ki;Sim, Yoo-Sik;Kim, Chang-Hyun;Jung, Jin-Young;Joo, Jin-Yang
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.4
    • /
    • pp.319-324
    • /
    • 2010
  • Objective : The aim of this study was to analyze the correlation between thromboembolic complications and anti platelet drugs before and after neurointervention. Methods : Blood samples and radiographic data of patients who received a neurointervention (coil embolization, stent placement or both) were collected prospectively. Rapid platelet function assay-aspirin (RPFA-ASA) was used to calculate aspirin resistance in aspirin reaction units (ARU). For clopidogrel resistance, a P2Y12 assay was used to analyze the percentage of platelet inhibition. ARU > 550 and platelet inhibition < 40% were defined as aspirin and clopidogrel resistance, respectively. Results : Both aspirin and clopidogrel oral pills were administered in fifty-three patients before and after neurointerventional procedures. The mean resistance values of all patients were 484 ARU and < 39%. Ten (17.0%) of 53 patients showed resistance to aspirin with an average of 597 ARU, and 33 (62.3%) of 53 patients showed resistance to clopidogrel with an average of < 26%. Ten patients demonstrated resistance to both drugs, 5 of which suffered a thromboembolic complication after neurointervention (mean values : 640 ARU and platelet inhibition < 23%). Diabetic patients and patients with hypercholesterolemia displayed mean aspirin resistances of 513.7 and 501.8 ARU, and mean clopidogrel resistances of < 33.8% and < 40.7%, respectively. Conclusion : Identifying individuals with poor platelet inhibition using standard regimens is of great clinical importance and may help prevent cerebral ischemic events in the future. Neurointerventional research should focus on ideal doses, timing, choices, safety, and reliable measurements of anti platelet drug therapy, as well as confirming the clinical relevance of aggregometry in cerebrovascular patients.

Genial tubercle position and genioglossus advancement in obstructive sleep apnea (OSA) treatment: a systematic review

  • Chang, Edward T.;Kwon, Yong-Dae;Jung, Junho;Capasso, Robson;Riley, Robert;Liu, Stanley C.;Camacho, Macario
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.34.1-34.5
    • /
    • 2019
  • Background: To systematically review the literature for methods to localize the genial tubercle as a means for performing an advancement of the genioglossus muscle. Methods: PubMed, Google Scholar, CRISP, EMBASE, CINAHL, and Scopus were searched from inception through June 16, 2015. Results: One hundred fifty-two articles were screened, and the full text versions of 12 articles were reviewed in their entirety and 7 publications reporting their methodology for localizing the genial tubercle. Based upon these measurements and the results published from radiographic imaging and cadaveric dissections of all the papers included in this study, we identified the genial tubercle as being positioned within the mandible at a point 10 mm from the incisor apex and 10 mm from the lower mandibular border. Conclusion: Based upon the results of this review, the genial tubercles were positioned within the mandible at a point 10 mm from the incisor apex and 10 mm from the lower mandible border. It may serve as an additional reference for localizing the genial tubercle and the attachment of the genioglossus muscle to the mandible, although the preoperative radiological evaluation and the palpation of the GT are recommended to accurately isolate.