• Title/Summary/Keyword: radiographic measurements

Search Result 131, Processing Time 0.029 seconds

Correlation of Cervical Disc Degeneration with Sagittal Alignments of Cervical Spine (두경부 시상면 정렬과 경추 추간판 퇴행성 변화와의 상관관계)

  • Jeon, Dae Geun;Park, Jinyoung;Park, Jung Hyun;Yun, Wang Hyeon
    • Clinical Pain
    • /
    • v.18 no.1
    • /
    • pp.8-15
    • /
    • 2019
  • Objective: To determine the relationship between cervical sagittal parameters and the degree of the cervical disc degeneration at each cervical level by using cervical plain radiographs and disc degeneration grading. Method: This study analyzed 110 patients with posterior neck pain. Cervical radiographic measurements included the occipito-cervical (O~C2) angle; sagittal Cobb angles of C1~C2, C2~C7; and sagittal vertical axis (SVA) of C1~C7 and C2~C7. The degenerations of cervical discs at each level were evaluated through Pfirrmann grading system by magnetic resonance images of the cervical spine. The correlations between the cervical sagittal measurements and the disc degeneration at each level were analyzed by Spearman's correlation. Results: A significant correlation was found for the C2~C7 angle with disc degenerations at C2~C6 levels. O~C2 angle was correlated significantly with disc degenerations at C2~C4 and C5~C7 levels. There was significant correlation between C1~C2 angle and disc degeneration at C6~C7 level. No significant relationship was found between the cervical SVA and the cervical disc degeneration at all cervical levels. Conclusion: Cervical sagittal parameters representing cervical angles (C2~C7, O~C2, and C1~C2 angles) were significantly correlated with the degree of the cervical disc degeneration. These findings suggest that the loss of the natural cervical lordosis rather than loss of natural SVA could be correlated with progression of the cervical disc degeneration.

Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles

  • Nikneshan, Sima;Aval, Shadi Hamidi;Bakhshalian, Neema;Shahab, Shahriyar;Mohammadpour, Mahdis;Sarikhani, Soodeh
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.257-262
    • /
    • 2014
  • Purpose: This study was performed to evaluate the effect of changing the orientation of a reconstructed image on the accuracy of linear measurements using cone-beam computed tomography (CBCT). Materials and Methods: Forty-two titanium pins were inserted in seven dry sheep mandibles. The length of these pins was measured using a digital caliper with readability of 0.01 mm. Mandibles were radiographed using a CBCT device. When the CBCT images were reconstructed, the orientation of slices was adjusted to parallel (i.e., $0^{\circ}$), $+10^{\circ}$, $+12^{\circ}$, $-12^{\circ}$, and $-10^{\circ}$ with respect to the occlusal plane. The length of the pins was measured by three radiologists, and the accuracy of these measurements was reported using descriptive statistics and one-way analysis of variance (ANOVA); p<0.05 was considered statistically significant. Results: The differences in radiographic measurements ranged from -0.64 to +0.06 at the orientation of $-12^{\circ}$, -0.66 to -0.11 at $-10^{\circ}$, -0.51 to +0.19 at $0^{\circ}$, -0.64 to +0.08 at $+10^{\circ}$, and -0.64 to +0.1 at $+12^{\circ}$. The mean absolute values of the errors were greater at negative orientations than at the parallel position or at positive orientations. The observers underestimated most of the variables by 0.5-0.1 mm (83.6%). In the second set of observations, the reproducibility at all orientations was greater than 0.9. Conclusion: Changing the slice orientation in the range of $-12^{\circ}$ to $+12^{\circ}$ reduced the accuracy of linear measurements obtained using CBCT. However, the error value was smaller than 0.5 mm and was, therefore, clinically acceptable.

Radiographic Measurements of Normal Spleen Size in Dogs (개에서 정상 비장크기의 방사선학적 계측)

  • Choi, Ho-Jung;Lee, Young-Won;Lee, Kyung-Woo;Wang, Ji-Hwan;Jung, In-Jo;Yeon, Seong-Chan;Lee, Hyo-Jong;Lee, Hee-Chun
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.584-587
    • /
    • 2007
  • The purpose of this study was to estimate the standard of normal spleen size and its variations in relation to age, body weight(BW) and 1st lumbar vertebra($L_1$) length using radiographs. The Maximum transverse length (MTL) and maximum vertical length(MVL) of the spleen were obtained from ventrodorsal abdominal radiographs of 134 dogs which underwent radiography for indications unrelated to splenic disease. Splenic size did not significantly correlated with the age. MTL and MVL increased with BW according to the nonlinear correlation. Also, MTL and MVL increased with $L_1$ length according to the linear correlation.

A RADIOGRAPHIC STUDY OF THE HYOID BONE POSITION IN MALOCCLUSION (설골위치에 관한 연구)

  • Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.17 no.1
    • /
    • pp.7-13
    • /
    • 1987
  • This study was conducted to clarify the relationship of hyoid bone position to tongue position and mandible when malocclusion is categorized in the bilateral and in the vertical components. Five groups of samples (normal occlusion, unilateral and bilateral cross-bite, openbite, deep-bite) were selected for his investigation by utilizing the cephalograms. On the basis study, the following conclusions were obtained; 1. In the normal group. the mean hyoid position (H-M) was $9.83{\pm}4.27mm$. The mean distance of hyoid body to tongue dorsum (H-T) was $52.17{\pm}6.70mm$. The ratio of H-M/H-T was $18.59\%$. 2. In all malocclusion groups, the hyoid position (H-M) was found to be larger than that of the norm except the deep overbite group 3. The tongue dorsum position (H-T) was increased, compared to that of norm, in all malocclusion groups. 4. Hyoid position (H-M) was found to show high correlation to the ratio of H-M/H-T, H-T, PI-T (0.890, 0.699, 0.455). 5. The hyoid position (H-M) was found to show low correlation to the measurements of mandible, but among them the ODI was found to show conversely a little higher correlation against hyoid position (H-M).

  • PDF

A STUDY ON MEASUREMENTS OF TOOTH LENGTH IN ORTHOPANTOMOGRAM (Orthopantomogram상에서의 치아 장경 측정에 관한 연구)

  • Jeong Chang Hoon;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.129-135
    • /
    • 1994
  • This study was performed to evaluate the accuracy of orthopantomogram by measuring the actual and radiographic tooth length and by analyzing the vertical magnification rate. For this study, total 90 teeth of the maxilla and mandible teeth and a dry skull were used. This experiment was attached with metal balls of 1±0.02㎜ at the root and the crown cusp tips of central, 2nd premolar, 1st molar of the maxilla and mandible and the teeth were embedded in dry skull, and then orthopantomogram was taken. The obtained results were as follows: 1. The average of tooth length in orthopantomogram was longer than that of actual tooth length. 2. The average of vertical magnification rate in the orthopantomogram to actual tooth length was 17-26%. 3. Vertical magnification rate of the maxilla teeth was 18-26% and that of mandibular teeth was 17-23%, and the magnification of maxillary teeth was larger than that of mandible teeth(P<0.0l). 4. Vertical magnification rate of posterior area was 22-26% and that of anterior area was 17-18%, and the magnification of anterior area was less than that of posterior area(P<0.01).

  • PDF

Is the Arch Index Meaningful

  • Lung, Chi-Wen;Yang, Sai-Wei;Hsieh, Lin-Fen
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.187-196
    • /
    • 2009
  • The foot type is classified into normal, high or low arch according to either foot print or medial longitudinal arch (MLA) height. Plantar fasciitis, heel pain, Achilles tendinitis, stress fracture, metatarsalgia, knee pain, shin splint pain, and etc are common foot disorders and associate to the foot type. The purpose of this study was to evaluate several suggested bony inclination used to classified the abnormal foot and if the arch index (AI) was correlated with foot morphology. Lateral view and dorso-plantar view of radiographic images and flatbed scanner measurements obtained from 57 college students were analyzed. Results showed that AI measured in this study was higher than Caucasian Americans and European, but similar with African. The ethnic origin could influent the AI distribution. The AI provided a simple quantitative means of assessing the structure of lateral and medial longitudinal arches. The correlation coefficients of true bone height with AI could be further improved by normalized foot width rather than foot length. AI also demonstrated as a good indicator of inclination between calcaneus-fifth metatarsal (CalM5) and calcaneus-first metatarsal (CalX), it is a good means to classify the foot type.

Radiological Evaluation on Dislocation of the Hip with Spastic Cerebral Palsy (경직형 뇌성마비 아동의 고관절 탈구에 대한 방사선학적 평가)

  • Kim, Jeong-Hwan;Kim, Yong-Nam
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.1
    • /
    • pp.9-17
    • /
    • 2004
  • The purpose of this study are to determine the proper radiographic measurements for hip deformity in spastic cerebral palsy patients, and the correlation of hip deformity with neurological involvement, ability of ambulation. Thirty children with cerebral palsy(22 males, 8 females) were evaluated by measurement of the migration index, acetabular index, center edge angle from bilateral hip APs(anterior posterior view). The result are as follows; 1. The incidence of hip dislocation, among the thirty children fifteen children were found to be dislocated, and more significantly high in non-walking group than in walking group(p<0.05) and in quadriplegia than in diplegia(p<0.05). 2. When compared to normal hip and dislocation hip, the migration index was significantly higher(p<0.01) and the center edge angle was lower in the dislocation hip than in the normal hip. 3. Correlation of radiological findings in right and left hip, the migration index and the center edge angle were highly correlated(p<0.01). We recommand regular intervals X-ray study for early diagnosis and management of hip dislocation in spastic cerebral palsy.

  • PDF

Uniqueness of radiographic patterns of the frontal sinus for personal identification

  • Patil, Neha;Karjodkar, Freny R.;Sontakke, Subodh;Sansare, Kaustubh;Salvi, Rohini
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.213-217
    • /
    • 2012
  • Purpose: This study was performed to evaluate the uniqueness and reliability of the frontal sinuses by comparing various patterns of frontal sinus as observed on Waters' radiographs for individual identification. Materials and Methods: Three Waters' radiographs of 100 individuals, taken on day one, after 6-8 months, and one radiograph with a slight variation in angulation, to mimic conditions out in the field or during autopsy. Three observers were randomly given radiographs from all there packets for comparisons and identification, by the method of superimposition and individual uniqueness. Results: The comparative identification by superimposition of the frontal sinus was 100% positive. The size, shape, unilateral or bilateral presence, absence, and septa were observed to be unique in each case; neither had the measurements changed over a period of time. Conclusion: The need to establish a reliable, low-cost, and easily reproducible method for human identification prompted the elaboration of technical, precise, and accessible parameters, such as the evaluation of the area, asymmetry, and shape of the frontal sinus. Comparison among each of the frontal sinuses of the 100 people in the sample revealed that no two sinuses are the same, that is, the sinus is unique to each individual.

A study on the relationship between jaw size and tooth size (치아크키와 악골크기의 상관관계에 관한 연구)

  • Ahn, Hyo-Beom;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.33 no.3 s.98
    • /
    • pp.157-167
    • /
    • 2003
  • The purpose of this study was to find whether there is a correlation between tooth size and jaw size. Dental stone models and cephalometric radiographic films of 87 untreated individuals were evaluated. Repeated measurements of the maximum mesiodistal width of the teeth were taken by means of a digital vernier caliper. Linear measurements of jaw size were assessed by means of a digitizer and Visual C++ program. All measurements were taken separately according to the subject's gender. To determine the relationship between jaw and tooth size, the Pearson correlation was used. The results were as follows: 1. Male and female subjects showed a statistical difference in regard to tooth size and jaw size 2. In contrast to the results of the male subjects, there were no statistically significant correlations between maxillary size and maxillary teeth size in female subjects 3. In male subjects, the two maxillary sizes of PTM vert-ANS vert (FH plane) and PTM vert-A yen (palatal plane) were significantly correlated with themaxillary teeth size. Especially, the size of the upper central incisor showed significant correlation with all maxillary sizes. 4. In both male and female subjects, mandibular size B vert- Point J vert (mandibular plane) showed significant correlation with mandibular teeth size. As gleaned kom the results of this study, the relationship between jaw size and tooth size was fair or little in natural occurring good occlusion.

Ultrasonographic and radiographic evaluation for the quantitative diagnosis of diffuse hepatic disease in dogs (개에서 미만성 간장병변의 정량적 진단을 위한 초음파 및 방사선학적 평가)

  • Sung, Jai-ki;Lee, Hee-chon;Yoon, Jung-hee;Lee, Young-won;An, Yong-joo;Choi, Ho-jung;Choi, Ji-hye
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.4
    • /
    • pp.918-928
    • /
    • 1998
  • The present study was done with two aims. First, to evaluate the radiographic measurements of liver volumes in normal and hepatomegaly dogs induced by carbon tetrachloride. Second, to investigate quantitative tissue echo pattern by ultrasonography. Gray level histogram of the normal liver and the kidney were estimated with carbon tetra-chloride intoxication. In normal, r-square for liver volume to body weight was 0.93372, and this showed direct linear regression. Gray level histograms of the normal liver and the kidney were $19.150{\pm}2.490$(mean${\pm}$SD) and $13.175{\pm}2.686$(mean${\pm}$SD) respectively(p < 0.01). Liver parenchymal echogenicity was more hyperechogenic than kidney cortex echogenicity. Liver/Kidney ratio was $1.504{\pm}0.313$ and it can be used relative comparison of liver and kidney parenchymal echogenicity. In carbon-tetrachloride($CCl_4$) intoxication, changes of liver volume appeared to increase up to 24 hours after administration (p < 0.05), and decreased gradually to normal level after 2~5 days. Gray level histogram of liver parenchyma decreased up to 24hours (p < 0.01) after intoxication and then gradually increased to normal level. But that of kidney cortex had no significant change. Liver/Kidney ratio also decreased by 2 days(p < 0.01) and then gradually increased to normal level. On histopathologic features of hepatic tissues in carbon tetrachloride intoxication, both coagulative necrosis of hepatic cell and hemorrhage of centrilobular & midzonal area were identified. Conclusively, plain radiography is a useful diagnostic method for evaluating liver volume in mild hepatomegaly. Especially, it is considered that an adequate numerical processing of the liver length, depth and thoracic width and depth measurement would be helpful. Using gray level histogram, ultrasonographic evaluation was useful objective methods in early diagnosis of diffuse hepatic disease.

  • PDF