• Title/Summary/Keyword: radiographic image interpretation

Search Result 14, Processing Time 0.025 seconds

Image interpretation errors often observed in a dental clinic (임상에서 흔히 관찰되는 영상판독 오류)

  • Park, In-Woo
    • The Journal of the Korean dental association
    • /
    • v.54 no.9
    • /
    • pp.712-728
    • /
    • 2016
  • These days, the clinical course of dental imaging sector has done a lot of implant-related imaging courses, including cone beam CT. In contrast, the general image reading course is not given a lot of opportunities to learn. Therefore, it is imperative that we talk about the general image interpretation that can be read easily applied in a dental clinic. When we see a strange radiographic finding of our patient in the dental clinic, we should first check whether the radiographic finding is a normal finding or a morbidity. If the finding is diagnosed as a morbidity, you should make plans for the appropriate therapy. The most important step is classification between normal state and morbidity. Some lesions may occur without any clinical symptoms. Therefore, we should read all the parts of radiographs, even the patient does not have clinical symptoms.

  • PDF

THE STUDY OF THE INTERPRETATION OF THE TMJ RADIOGRAPHY USING SUBTRACTION TECHNIQUE (Subtraction법을 이용한 악관절 X-선사진 판독에 관한 연구)

  • Na Choon-Wha;Yoo Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.175-181
    • /
    • 1987
  • The purpose of this study is to know the value of the photographic subtraction technic in the transcranial oblique lateral projection of the TMJ. The author examined the transcranial oblique lateral projection radiographs which comprise 50 cases of 32 persons, compared the transcranial oblique lateral projection films and those subtraction films. The following results were obtained. 1) The condyle at closed jaw position had showed a reversed tone image, but the condyle at the opening position had showed a re-reversed ordinary image. Both condyles had showed one subtraction film because radiographic interpretation of TMJ was easy. 2) On 50 cases of subtraction films, 46 cases had showed same radiographic images compared with trascranial oblique lateral projection films. Four cases (3 cases of erosion, 1 cases of sclerosis) had showed additional changes of images so that capability of interpretation was improved.

  • PDF

Effects of Practical Training Using 3D Printed Structure-Based Blind Boxes on Multi-Dimensional Radiographic Image Interpretation Ability (3D 프린팅 구조물 기반 블라인드박스를 이용한 실습교육이 다차원 방사선영상해독력에 미치는 효과)

  • Youl-Hun, Seoung
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.131-139
    • /
    • 2023
  • In this study, we are purposed to find the educational effect of practical training using a 3D printed structure-based blind box on multidimensional radiographic image interpretation. The subjects were 83 (male: 49, female: 34) 2nd year radiological science students who participated in the digital medical imaging practice that was conducted for 3 years from 2020 to 2022. The learning method used 3D printing technology to print out the inside structure of the blind box designed by itself. After taking X-rays 3 times (x, y, z axis), the structure images in the blind box were analyzed for each small group. We made the 3D structure that was self-made with clay based on our 2D radiographic images. After taking X-rays of the 3D structure, it was compared whether it matches the structural image of the blind box. The educational effect for the practical training surveyed class faithfulness, radiographic image interpretation ability (attenuation concept, contrast concept, windowing concept, 3-dimensional reading ability), class satisfaction (interest, external recommendation, immersion) on a 5-point Likert scale as an anonymous student self-writing method. As a result, all evaluation items had high positive effects without significant differences between males and females. Practical education using blind boxes is a meaningful example of radiology education technology using 3D printing technology, and it is expected to be used as content to improve students' problem-solving skills and increase satisfaction with major subjects.

Basic principles of interpretation in Dental imaging (치의학 영상 판독의 기본원리)

  • Han, Sang-Sun
    • The Journal of the Korean dental association
    • /
    • v.54 no.9
    • /
    • pp.704-711
    • /
    • 2016
  • Radiologic images in dentistry are essential to perform the diagnosis, treatment, and tracking process of prognosis, thus the ability of accurate evaluation in the diagnostic images is requested for dental clinician. Radiologic interpretation means recognition of a normality and an abnormality and to report the possible diagnosis and differential diagnosis list. Therefore, dental clinicians should be familiar with the basic principle of interpretation of intraoral and extraoral radiographic images primarily used in dental clinics. Recently, dental cone beam CT is widely used for diagnositc process, thus understanding the three dimensional images is requested. The objective of this manuscript is to help the dental clinicians to interpret accurately the diagnostic images by introducing the basic principles of the step by step analytic process in the appearance of a lesion.

  • PDF

Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions

  • Dantas, Raquel Venancio Fernandes;Sarmento, Hugo Ramalho;Duarte, Rosangela Marques;Meireles Monte Raso, Sonia Saeger;de Andrade, Ana Karina Maciel;Dos Anjos-Pontual, Maria Luiza
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.145-151
    • /
    • 2013
  • Purpose: This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. Materials and Methods: Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were imaged by conventional radiograph using #4 sized intraoral film and digital images were taken in high speed and high resolution modes using a phosphor storage plate. Densitometric evaluation of the enamel, dentin, restorative materials, a lead sheet, and an aluminum step wedge was performed on the radiographic images. For the evaluation, the Al equivalent (mm) for each material was calculated. The data were analyzed using one-way ANOVA and Tukey's test (p<0.05), considering the material factor and then the radiographic method factor, individually. Results: The high speed mode allowed the highest radiopacity, while the high resolution mode generated the lowest values. Furthermore, the high resolution mode was the most efficient method for radiographic differentiation between restorative composites and dentin. The conventional radiograph was the most effective in enabling differentiation between enamel and composites. The high speed mode was the least effective in enabling radiographic differentiation between the dental tissues and restorative composites. Conclusion: The high speed mode of digital imaging was not effective for differentiation between enamel and composites. This made it less effective than the high resolution mode and conventional radiographs. All of the composites evaluated showed radiopacity values that fit the ISO 4049 recommendations.

A RADIOGRAPHIC STUDY ON THE MUCOSAL CYST OF THE MAXILLARY SINUS (상악동 점액성 낭에 관한 방사선학적 연구)

  • Park Eung-Chun;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.2
    • /
    • pp.277-285
    • /
    • 1993
  • This study was performed to evaluate the role of Waters' view and panoramic view for the interpretation of mucosal cyst of the maxillary sinus and to determine the radiographic features of that according to the sites and sizes. For this study, clinically 25 cases of mucosal cyst of the maxillary sinus were used, and experimentally with two dry skulls, rubber ball of 15mm in diameter for marked radiopacity, and two jelly balls of 8 and 20㎜ in diameter for the similar radiopacity to cyst were used. The 25 cases with 25 panoramic views and 15 Waters' views were first analyzed, and secondly, the radiographic features of artificial lesions attached to the each wall of the antrum on Waters' view and panoramic view were analyzed. The obtained results were as follows: At clinical analysis, 1. 4 cases of 13-14㎜, 4 cases of 15-19mm, 14 cases of 20-25㎜, 3 cases of over 30㎜ in dia- meter were found on panoramic views. And 24 cases of 25 cases showed no relationship with teeth, and only 1 case was associated with advanced periodontal disease 2. The majority of mucosal cysts appeared to arise the posterior portion of the floor of the sinus and were superimposed with the inominate line of zygoma and the horizontally linear image of hard palate on panoramic view. 3. Only 2 cases of 15 cases were identified on both films. At experimental analysis, 4. On Waters' view, the images of the artificial lesion of the anterior portion and midportion of the floor of the sinus were lessend in diameter compared with the real size. On panoramic views, the images of the lesion were more radiolucent with lessened diameter than images on Water' view. 5. The images of the lesion of the posterior wall and the posterior portion of the floor of sinus on panoramic view were well detected by the preeducated group but not or poorly detected by the non-preeducated observer group. 6. On Waters' view, both observer groups recognized that the cystic images of the posterior portion of the floor of the maxillary sinus were superimposed with the petrous portion of the skull.

  • PDF

LOCALIZATION TO THE PRODUCTION OF RADIOGRAPHIC IMAGE (X선상 형성과정에서 위치측정에 관하여)

  • Park T. W.
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.11 no.1
    • /
    • pp.75-78
    • /
    • 1981
  • The diagnostic value of a intra oral film is related to projecting technic and interpretation. The intra-oral film is a single plane representation of a three dimensional object, therefore superimposition is inevitablly present. The purpose of this article is to show how foreign objects in the jaw may be localized. The author used double exposure technics, that are changed angulation of vertical or horizontal to one film. The obtained results are as fallow: 1. In the upper anterior region, the moving distance of the labially impacted reference object was greater than that of the palatally impacted one. 2. In the upper molar region, the moving distance of the mesiobuccal root apex was the greatest and that of palatal root apex was the shortest. 3. In the lower molar region, the change of the alveolar bone level in the buccal side was greater than that of lingual side.

  • PDF

An experimental study on the readability of digital images in the furcal bone defects (디지털영상을 이용한 치근이개부 실험병소의 판독능에 관한 연구)

  • Kang Hyung-Wuk;Hwang Eui-Hwan;Lee Sang-Rae
    • Imaging Science in Dentistry
    • /
    • v.33 no.2
    • /
    • pp.71-77
    • /
    • 2003
  • Purpose : To evaluate and compare the efficacy of digital radiographic images in the detection of bone loss at the bifurcation area of the mandibular first molar with traditional film-based periapical radiographs, Materials and Methods : One dried human mandible with minimal periodontal bone loss around the first molar was selected and an artificial alveolar bone defect at the bifurcation area was serially prepared over 18 steps. Images were taken using a direct CCD-based system and with F-speed periapical films. The images were evaluated by seven interpreters (3 radiologists, 3 periodontologists, and 1 general dentist) using a 5-point confidence rating scale. Results : The readability of both periapical radiographs and digital image increased as the size of the artificial lesion and exposure time increased (p < 0.05). Periapical radiographs offered greater readability of smaller bone defects than digital images, and the coefficient of variation of mean score between periapical radiographs and digital images showed a significant difference. Conclusion : The experimental results indicate that a significant difference in the coefficient of variation of mean score exists between periapical radiographs and digital images, and that traditional film-based periapical images offer greater readability of smaller bone defects than digital images can presently offer.

  • PDF

MRI Quantification Analysis on Fall in Sick Times of the Cerebral Infarction Patients Using Object-Centered Hierarchical Planning (객체 중심 계층적 계획을 이용한 뇌경색 환자의 시기별 MRI 정량적 분석에 관한 연구)

  • Ha, Kwang;Jeon, Gye-Rok;Kim, Gil-Joong
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.61-68
    • /
    • 2003
  • This paper presents a quantitative analysis method for fall in sick times of the cerebral infarction patients using three types of magnetic resonance image, which play an important role in deciding method of medical treatment. For this object, image characteristics obtained by three radiographic methods of MRI and their relation were analyzed by means of object centered hierarchical Planning method. This methode presents an approach to the knowledge based processes for image interpretation and analysis. To compare three type of MRI. a multiple warping algorithm and affine transform method performed for image matching. Then each fall in sick times level of cerebral infarction was quantified and pseudo-color mapping performed by comparing gray level value one another according to Previously obtained hand maid data. The result of this study was compared to a medical doctors decision.

A comparative study on the accuracy of digital subtraction radiography according to the aquisition methods of reconstructed images (재구성영상 형성방법에 따른 디지털영상공제술의 정확성 비교연구)

  • Huh Young-June;Jeon In-Seong;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;Kim Jong-Dae
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.107-111
    • /
    • 2002
  • Purpose : To compare the accuracy of digital subtraction images acquired by two different methods different in positioning four reference points for geometrical standardization. Materials and Methods : A total of 36 digital radiographic images of 6 volunteers were taken at the areas of the incisor, premolar, and molar of both the maxilla and mandible using the Digora system. Each image was moved 4 mm vertically and horizontally. Four oral and maxillofacial radiologists performed digital subtraction radiography between the paired images before and after movement using Emago (Oral Diagnostic Systems, Amsterdam, The Netherlands) and Sunny (Biomedisys Co., Seoul, Korea). The standard deviation of the internal gray value in Region of Interest (ROI) was statistically analyzed between the two programs using the paired t-test. Results : The standard deviation of pixel gray values from the digital subtraction images using the Sunny program were lower than that of the Emago program (p<0.05). All observers showed significant differences between each other when the Sunny program was used (p<0.05), but one observer showed a significantly higher score than other observers when they used Emago (p<0.05). The standard deviations of premolar area from both Sunny and Emago programs were significantly higher than those of anterior and molar regions (p<0.05). Conclusion: The subtracted images using the Sunny program were more accurate and sensitive than those taken using the Emago program.

  • PDF