• Title/Summary/Keyword: radiator

Search Result 434, Processing Time 0.03 seconds

Enrichment of Resveratrol Content in Harvested Grape using Modulation of Cell Metabolism with UV Treatment (수확 후 포도의 UV 처리 세포대사조절에 의한 레스베라트롤 함량 강화)

  • Cho, Yong-Jin;Maeng, Jin-Soo;Kim, Chong-Tai;Pyee, Jae-Ho
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.5
    • /
    • pp.739-745
    • /
    • 2011
  • This study was performed to investigate the enrichment of resveratrol content in harvested grapes using the modulation of cell metabolism with ultra-violet (UV) irradiation. Resveratrol, a phytoalexin, is produced by stilbene synthase (STSY) from malonyl-CoA and ${\rho}$-coumaroyl-CoA. Its biosynthesis has been reported to be induced by UV and other environmental factors. Reverse transcriptase-polymerase chain reaction (RT-PCR) analysis showed that STSY Promoter 1 in grapes was very highly expressed by treatment with UV. Grapes were harvested and treated for post-harvest induction of STSY gene expression with UV, and then their resveratrol content was analyzed. UV treatment for 5 minutes provided the best condition for the induction of STSY gene expression. When harvested Gerbong and MBA grapes were treated with a prototype UV radiator, their resveratrol content was enriched upto 5 times compared with untreated grapes. These results suggest that a post-harvest UV treatment can be applied to enrich resveratrol content in grapes and add value to them.

Characterization of the a-Se Film for Phosphor based X-ray light Modulator (형광체 기반 X선 광 변조기를 위한 비정질 셀레늄 필름 특성)

  • Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Ho;Cha, Byung-Youl;Shin, Jung-Wook;Lee, Kun-Hwan;Mun, Chi-Woong;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.306-309
    • /
    • 2007
  • PXLM(Phosphor based x-ray light modulator) has a combined structure by phosphor, photoconductor, and liquid crystal and it can realize x-ray image of high resolution in clinical diagnosis area. In this study, we fabricated a photoconductor and investigated electrical and optical properties to confirm application possibility of radiator detector of PXLM structure. As photoconductor, amorphous selenium(a-Se), which is used most in DR(Digital radiography) of direct conversion method, was used and for formation of thin film, it was formed as $20{\mu}m-thick$ by using thermal vacuum evaporation system. For a produced a-Se film, through XRD(X-ray diffraction) and SEM(Scanning electron microscope), we investigated that amorphous structure was uniformly established and through optical measurement, for visible light of 40 $0\sim630nm$, it had absorption efficiency of 95 % and more. After fabricated a-Se film on the top of ITP substrate, hybrid structure was manufactured through forming $Gd_2O_3:Eu$ phosphor of $270{\mu}m-thick$ on the bottom of the substrate. As the result to confirm electrical property of the manufactured hybrid structure, in the case of appling $10V/{\mu}m$, leakage current of $2.5nA/cm^2$ and x-ray sensitivity of $7.31nC/cm^2/mR$ were investigated. Finally, we manufactured PXLM structure combined with hybrid structure and liquid crystal cell of TN(Twisted nematic) mode and then, investigated T-V(Transmission vs. voltage) curve of external light source for induced x-ray energy. PXLM structure showed a similar optical response with T-V curve that common TN mode liquid crystal cell showed according to electric field increase and in appling $50\sim100V$, it showed linear transmission efficiency of $12\sim18%$. This result suggested an application possibility of PXLM structure as radiation detector.

Model Between Lead and ZPP Concentration of Workers Exposed to Lead (직업적으로 납에 노출된 근로자들의 혈액중 납과 ZPP농도와의 관계)

  • Park, Dong-Wook;Paik, Nam-Won;Choi, Byung-Soon;Kim, Tae-Gyun;Lee, Kwang-Yong;Oh, Se-Min;Ahn, Kyu-Dong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.88-96
    • /
    • 1996
  • This study was conducted to establish model between lead and ZPP concentration in blood of workers exposed to lead. Workers employed in secondary smelting manufacturing industry showed $85.1{\mu}g/dl$ of blood lead level, exceeding $60{\mu}g/dl$, the Criteria for Removal defined by Occupational Safety and Health Act of Korea. Average blood lead level of workers in the battery manufacturing industry was $51.3{\mu}g/dl$, locating between $40{\mu}g/dl$ and $60{\mu}g/dl$, the Criteria for Requiring Medical Removal. Blood lead level of in the litharge and radiator manufacturing industry was below $40{\mu}g/dl$, the Criteria Requiring Temporary Medical Removal. Blood lead levels of workers by industry were Significantly different(p<0.05). 50(21 %) showed blood lead levels above $60{\mu}g/dl$, the Criteria for Removal and 66(27.7 %) showed blood lead levels between the Criteria for Requiring Medical Removal, $40-60{\mu}g/dl$. Thus, approximately 50 percent of workers indicated blood lead levels above $40{\mu}g/dl$, the Criteria Requiring Temporary Medical Removal and should receive medical examination and consultation including biological monitoring. Average ZPP level of workers employed in the secondary smelting industry was $186.2{\mu}g/dl$, exceeding above $150{\mu}g/dl$, the Criteria for Removal. Seventy seven of all workers(32.3 %) showed ZPP level above $100-150{\mu}g/dl$, the Criteria for Requiring Medical Removal. The most appropriate model for predicting ZPP in blood was log-linear regression model. Log linear regression models between lead and ZPP concentrations in blood was Log ZPP(${\mu}g/dl$) = -0.2340 + 1.2270 Log Pb-B(${\mu}g/dl$)(standard error of estimate: 0,089, ${\gamma}^2=0.4456$, n=238, P=0.0001), Blood-in-lead explained 44.56 % of the variance in log(ZPP in blood).

  • PDF

Design of Microstrip Patch Antenna using Inset-Fed Layered for Metallic Object in u-Port (U-항만 환경에서 금속부착을 위한 인셋 급전 마이크로패치 안테나 설계)

  • Choi, Yong-Seok;Seong, Hyeon-Kyeong
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.2
    • /
    • pp.80-85
    • /
    • 2015
  • In this paper, we present, an indstrial RFID layered microstrip patch antenna is designed using an inset feed method in order to improve recognition rates in a long distance as tags are attached to metal object by improving a problem of feeding power in fabricating metal tags and reducing effects of metallic object. The inset feed shows a distinctive characteristic that has no separation between emitters and feed lines differing from a structure with the conventional inductive coupling feed. This structure makes possible to produce a type that presents a low antenna height and enables impedance coupling for tag chips. Although it shows a difficulty in the impedance coupling due to increases in the parasite capacitance between a ground plane and an emitter in an antenna according to decreases in the height of a tag antenna, it may become a merit in designing the tag antenna because the antenna impedance can be determined as an inductive manner if a shorted structure is used for feeding power. Therefore, in this paper the microstrip patch antenna is designed as a modified type and applies the inset feed in order to reduce effects of metallic objects where the antenna is be attached. Also, the antenna uses a multi-layer structure that includes a metal plate between radiator and ground instead of using a single layer.

Modelling and Preliminary Prediction of Thermal Balance Test for COMS (통신해양기상위성의 열평형 시험 모델 및 예비 예측)

  • Jun, Hyoung-Yoll;Kim, Jung-Hoon;Han, Cho-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.3
    • /
    • pp.403-416
    • /
    • 2009
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and developed by KARl for communication, ocean and meteorological observations. It will be tested under vacuum and very low temperature conditions in order to verify thermal design of COMS. The test will be performed by using KARI large thermal vacuum chamber, which was developed by KARI, and the COMS will be the first flight satellite tested in this chamber. The purposes of thermal balance test are to correlate analytical model used for design evaluation and predicting temperatures, and to verify and adjust thermal control concept. KARI has plan to use heating plates to simulate space hot condition especially for radiator panels of satellite such as north and south panels. They will be controlled from 90 K to 273 K by circulating GN2 and LN2 alternatively according to the test phases, while the main shroud of the vacuum chamber will be under constant temperature, 90 K, during all thermal balance test. This paper presents thermal modelling including test chamber, heating plates and the satellite without solar array wing and Ka-band reflectors and discusses temperature prediction during thermal balance test.

A Study on the Design and Fabrication of a Dual-Ground and Broad-band Internal Antenna for 4th-Generation Mobile Communications (4세대 이동통신용 이중접지 내장형 광대역 안테나의 설계와 제작에 관한 연구)

  • Park, Jung-Ryul;Choi, Byoung-Ha;Kong, Jin-Woo;Yun, Hyun-Su;Kim, Gue-Chol
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.2
    • /
    • pp.100-108
    • /
    • 2008
  • In this paper, the dual-ground, high-gain and broad-band internal antenna has been designed and fabricated for 4th-generation mobile communication applications. The optimized antenna was fabricated using photolithography method. The antenna consist of the patches, antenna and system ground, and a probe. The patch and ground plane were separated by air. In order to prevent the demage due to radiator swaying, the foams(${\varepsilon}_r{\fallingdotseq}1.03$) were used to fix the patches and ground. The conductor for the radiators was 0.05 [mm] thick. The measured input return loss showed less than -10 [dB] at the broadband from 3499 to 4743 [MHz]. It's measured bandwidth was 1244 [MHz]. The radiation patterns measured at 3400, 3600, 3800, 4000 and 4200 [MHz] showed Omni-directional characteristics. The gain in the E-plane and H-plane was 4.7 ~ 6.1 and 2.1 ~ 4.3 [dBi], respectively.

  • PDF

Designing a Wideband Antenna Using Diplexer Matching Network for Tactical Vehicles (다이플렉서 정합구조를 이용한 전술차량형 광대역 안테나 설계)

  • Cho, Ji-Haeng;Dong, Moon-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.9
    • /
    • pp.661-667
    • /
    • 2018
  • Tactical communication radio systems that employ software defined radios(SDRs) have been developed for achieving high-speed data transmissions and voice communications. Such systems possess multiband and multichannel features, and can potentially replace several existing radio systems. This paper proposes a design for wideband antennas by incorporating a diplexer matching network for tactical vehicles. The proposed antenna design includes two radiators(upper and lower) and a diplexer matching network connected to the end of the feed line such that the LC matching networks are interleaved in the lower radiator and spring mount. By employing the diplexer matching network, the designed antenna can perform wideband impedance matching for the fifty ohm feed line. The designed LC networks aid in varying the effective electrical length of the antenna according to the operation frequency. The primary objective behind adjusting the electrical length is to vary the current distribution above and below the LC networks. The proposed antenna was fabricated and tested in an open site. The obtained evaluation results show that the designed antenna can achieve a relative bandwidth of 190% with a VSWR value of 3.5:1, and can attain good antenna gains over VHF and UHF bands.

Cooling Efficiency and Growth of Tomato as Affected by Root Zone Cooling Methods in Summer Season (고온기 근권냉방방식에 따른 냉방효과와 토마토 생육)

  • 이재한;권준국;권오근;최영하;박동금
    • Journal of Bio-Environment Control
    • /
    • v.11 no.2
    • /
    • pp.81-87
    • /
    • 2002
  • This study was conducted to investigate the cooling efficiency and growth of tomatoes by root zone cooling device using a pad-box and cultivated system. The structure of the root zone cooling system using a pad-box was four piece of pads bonded an the side and a fan set at the bottom. Cool wind was generated by the outside air which was punched at intervals of 10 cm along three rows. Cold wind flowed to the root zone in the culture medium. The root zone cooling efficiency of cold wind generation by using a pad-box flowing through a wet-pad was determined. Major characteristic of this cuttural system consist of bed filled with a perlite medium and a ventilation pipe using PVC. The cold wind generation by a pad box (CWP) was compared to that of cold wind generation by a radiator (CWR), cold water circulation using a XL-pipe (CWX) and the control (non-cooling). When the temperature of water supplied was 16.2-18.4$^{\circ}C$, temperatures in the medium were 20.5~23.2$^{\circ}C$ for CWP 22.7~24.2$^{\circ}C$ for CWR, 22.8~24.27$^{\circ}C$ for CWX and 23.1~-29.6$^{\circ}C$ for the control. The results show that the cold wind temperature using the pad-box was lower by 1~2$^{\circ}C$ than that of cold water circulation in the XL-pipe and lower by 5~6$^{\circ}C$ than that of the control. Growth such as leaf length, leaf width, fresh weight and dry weight, was greater in three root zone cooling methods than in the control. Root activity was higher in the rat zone cooling methods than in the control. However, there was no significant difference among root zone cooling methods.

A Numerical Study of the Effects of Heat Transfer and Fluid Flow on Tube Insertion Length in Computer-Cooling Radiators (컴퓨터 CPU 냉각용 방열기 튜브 삽입길이에 따른 열유동 해석)

  • Choi, Jin-Tae;Kwon, Oh-Kyung;Yun, Jae-Ho;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.145-152
    • /
    • 2011
  • The performance of flat-tube radiators with louvered fins was numerically investigated for different tube insertion lengths. The results of numerical analysis using CFX-11 were compared with experimental results. In this study, three types of flat-tube radiators with louvered fins were considered. An experiment was conducted to validate the numerical results. Flow rate ratio (FR) and Stotal were introduced to understand the uniformity of flow distribution easily. The results of numerical analysis revealed that the heat transfer rate and pressure drop increased as the mass flow rate increased. Further, the results showed that the heat transfer rate of sample 3 with h/D = 0.5 was higher than that of the other samples. The pressure drop increased as the insertion length toward the header part increased, and the pressure drop in the case of sample 3 appeared to be the highest. The factor Stotal showed that the uniformity of the flow distribution in the case of sample 1 with h/D = 0 was higher than that in the case of the other samples.

Control Algorithm Characteristic Study of Cooling System for Automotive Fuel Cell Application. (차량용 연료전지 냉각시스템 제어 알고리즘 특성 연구)

  • Han, Jae Young;Park, Ji Soo;Yu, Sangseok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.1
    • /
    • pp.39-45
    • /
    • 2016
  • Thermal management of a fuel cell is important to satisfy the requirements of durability and efficiency under varying load conditions. In this study, a linear state feedback controller was designed to maintain the temperature within operating conditions. Due to the nonlinearity of automotive fuel cell system, the state feedback controller results in marginal stable under load condition from $0.5A/cm^2$ to $0.7A/cm^2$. A PWM (Pulse Width Modulation) and the modified state feedback controller are applied to control the temperature under the load condition from $0.5A/cm^2$ to $0.7A/cm^2$. The cooling system model is composed of a reservoir, radiator, bypass valve, fan, and a water pump. The performance of the control algorithm was evaluated in terms of the integral time weighted absolute error (ITAE). Additionally, MATLAB/SIMULINK$^{(R)}$ was used for the development of the system models and controllers. The modified state feedback controller was found to be more effective for controlling temperature than other algorithms when tested under low load conditions.