• 제목/요약/키워드: radiation weighting factor

검색결과 16건 처리시간 0.029초

화염의 총괄폭사 계수를 나타내는 급수계수 및 가중치의 계산 (Calculation of the Absorption Coefficient and Weighting Factor Expressing the Total Emissivity of Flame)

  • 하만영;허병기
    • 대한기계학회논문집
    • /
    • 제10권1호
    • /
    • pp.121-130
    • /
    • 1986
  • Using the sbsorption coefficients and the weighting factors of the gray gas, the total emissivities of C $O_{2}$- $H_{2}$O and C $O_{2}$- $H_{2}$O- transient species-soot gas mixtures can be expressed by the following equation, [a numerical formula] Where, $a_{i}$ and $K_{i}$ represent the weighting factor and the absorption coeffient of i-gray gas respectively; L is the pathlength of the gas. This equation is widely used for the analyses of the radiation heat transfer in the combustors of internal combustion engines and in the furnace of external combustion engines. In this work, a simple calculation model of the weighting factor and the absorption coeffient of the above equation was developed. The weighting factors and the absorption coefficients of combustion products were calculated by applying the model to various kinds of fossil fuels such as coal and heavy oil. Then, the computed total emissivities for each fuel and pathlength were compared with measured and calculated values which have been already published in the literatures. The followings were the results obtained through the comparisons between the calculated emissivites and the published values; the developed model for the calculations of the weighting factor and the absorption coefficient of C $O_{2}$- $H_{2}$O and C $O_{2}$- $H_{2}$O- transient species-soot gas mixtures could be applied over the wide ranges of the temperature and the pathlength; the errors between the total emissivities calculted and the values published were maximum 10%, and average 1%, respectively.

방사선량의 측정, 평가에서 선량당량(dose equivalent)과 등가선량(equivalent dose)의 정의 및 차이 (Definition and Difference between Dose Equivalent and Equivalent Dose in Radiation Dose Measurement and Evaluation)

  • 장시영
    • Journal of Radiation Protection and Research
    • /
    • 제18권1호
    • /
    • pp.1-7
    • /
    • 1993
  • 국제방사선방어위원회(ICRP)는 최근의 권고 60(1990)에서 이전의 권고 26(1976)에는 없었던 새로운 용어들을 도입하였다. 이중에서도 동 위원회는 지금까지 사용되어 왔던 국제 방사선단위 및 측정위원회(ICRU) 개념의 '션량당량(dose equivalent)'을 대체하는 용어로 '등가선량(equivalent dose)'을 새로 정의하여 방사선방어 프로그램에의 적용을 권고하고 있다. 그러나 한편 동 위원회는 선량 당량이라는 용어도 여전히 채택하고 있기 때문에 경우에 따라 두 양의 사용시 불필요한 혼동을 불러일으킬 수가 있다. 따라서 본 해설문에서는 방사선 방어, 관리 및 측정분야 종사자들의 이해를 돕기 위하여 두 양의 정의와 사용상의 차이점에 대하여 정리하였다.

  • PDF

CE형 원전의 격납건물내 중성자선량 평가 (Dose Evaluation of Neutron within Containment Building of a CE type Nuclear Power Plant)

  • 김태욱;한재문;김경덕;윤철환;서장수;김영재
    • 방사성폐기물학회지
    • /
    • 제3권1호
    • /
    • pp.23-30
    • /
    • 2005
  • CE형 원자력발전소를 대상으로 운전중 격납건물내 주요지점의 중성자장을 측정하여 작업자가 받을 수 있는 예상 방사선 피폭선량 등을 평가하고, 국제방사선방호위원회의 구권고(ICRP-26) 및 신권고(ICRP-60)에 따른 방사선 피폭선량 비교 및 교정 중성자장과 실제 중성자장의 방사선가중치 등을 분석해보았다. 분석결과 신권고에 따른 중성자가중치는 구권고에 의한 값보다 $2.42\~2.71$ 배 높은 것으로 나타났으며 , 측정지점의 중성자 방사선가중치 평균은 교정 중성자장의 평균과 비슷하였다. 중성자 평균에너지는 $42~158 keV$로 교정 중성자장의 평균에너지 500 keV보다 낮아 이럴 경우 각 측정지점에 대한 측정값은 실제 등가선량보다 보수적으로 평가될 수 있음을 알 수 있었다

  • PDF

방사선투과검사작업장 위험성 평가를 위한 방사선 위해도 지수 모델 주요인자 선정에 관한 연구 (A Study on the Selection of the Main Factors of Radiation Risk Index Model for assessing risk in Nondestructive Test workplace)

  • 권다영;한지영;배유정;김병수;김용민
    • 한국방사선학회논문지
    • /
    • 제12권4호
    • /
    • pp.459-466
    • /
    • 2018
  • 방사선작업종사자 및 방사선작업장의 위험성은 주로 피폭선량 값으로 평가되고 있다. 하지만, 방사선작업장은 사용하는 방사선 및 작업환경이 상이하다. 특히, 방사선투과검사작업장은 작업대상물, 차폐체 사용가능 유무 등에 따라 작업환경이 다양하다. 따라서 효율적인 방사선 방호를 위해서는 여러 가지 인자들을 검토하는 것이 필요하다. 이에 전문가 및 조장 방사선작업종사자들 대상으로 설문조사를 수행하였으며, 그 결과, 방사선원, 방사선피폭선량, 작업장관리현황, 판독특이자, 정기검사현황이 주요인자로 선정되었다. 또한, 설문조사 중요도를 바탕으로 1차 가중치(안)을 설정한 후 2차적으로 전문가 자문을 통해 인자 내 세부항목별 가중치를 선정하였다. 따라서 본 연구를 통해 선정된 주요인자를 바탕으로 하여 방사선투과검사작업장 위해도 지수 모델 개발이 가능할 것으로 판단된다.

전립선암의 방사선 치료 시 주변 정상장기 피폭선량을 이용한 암발생확률 평가 (Evaluation of Cancer Incidence Rate using Exposure Dose to Surrounding Normal Organs during Radiation Therapy for Prostate Cancer)

  • 이주아
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.351-356
    • /
    • 2022
  • 전립선암의 방사선치료 시 사용되는 세기조절방사선치료와 부피적회전방사선치료시 발생하는 광중성자선량을 측정하여, 암 발생률을 평가하며 기초자료를 제공하고자 하였다. Rando phantom에 중성자 측정용 광자극발광선량계를 복부와 갑상선에 위치시킨 상태에서 발생하는 광중성자선량을 측정하였다. 연구결과 세기조절방사선치료(7 portal)가 부피적회전방사선치료보다 복부와 갑상선 위치에서 모두 높게 측정되었다. ICRP 103의 명목위험계수를 이용하여 암 발생확률을 평가하였을 때, 세기조절방사선치료시 대장과 갑상선의 피폭으로 인한 암발생확률은 1,000명 당 9.9명 이었으며, 부피적회전방사선치료시는 1,000명 당 3.5명이었다. ALARA(As low as reasonably archievable)원칙에 의거하여 방사선치료계획 수립에 있어서 정상장기들의 피폭선량의 최소화를 위한 가이드라인이 되리라 사료된다.

Evaluation of Source Identification Method Based on Energy-Weighting Level with Portal Monitoring System Using Plastic Scintillator

  • Lee, Hyun Cheol;Koo, Bon Tack;Choi, Chang Il;Park, Chang Su;Kwon, Jeongwan;Kim, Hong-Suk;Chung, Heejun;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • 제45권3호
    • /
    • pp.117-129
    • /
    • 2020
  • Background: Radiation portal monitors (RPMs) involving plastic scintillators installed at the border inspection sites can detect illicit trafficking of radioactive sources in cargo containers within seconds. However, RPMs may generate false alarms because of the naturally occurring radioactive materials. To manage these false alarms, we previously suggested an energy-weighted algorithm that emphasizes the Compton-edge area as an outstanding peak. This study intends to evaluate the identification of radioactive sources using an improved energy-weighted algorithm. Materials and Methods: The algorithm was modified by increasing the energy weighting factor, and different peak combinations of the energy-weighted spectra were tested for source identification. A commercialized RPM system was used to measure the energy-weighted spectra. The RPM comprised two large plastic scintillators with dimensions of 174 × 29 × 7 ㎤ facing each other at a distance of 4.6 m. In addition, the in-house-fabricated signal processing boards were connected to collect the signal converted into a spectrum. Further, the spectra from eight radioactive sources, including special nuclear materials (SNMs), which were set in motion using a linear motion system (LMS) and a cargo truck, were estimated to identify the source identification rate. Results and Discussion: Each energy-weighted spectrum exhibited a specific peak location, although high statistical fluctuation errors could be observed in the spectrum with the increasing source speed. In particular, 137Cs and 60Co in motion were identified completely (100%) at speeds of 5 and 10 km/hr. Further, SNMs, which trigger the RPM alarm, were identified approximately 80% of the time at both the aforementioned speeds. Conclusion: Using the modified energy-weighted algorithm, several characteristics of the energy weighted spectra could be observed when the used sources were in motion and when the geometric efficiency was low. In particular, the discrimination between 60Co and 40K, which triggers false alarms at the primary inspection sites, can be improved using the proposed algorithm.

Study on Dual-Energy Signal and Noise of Double-Exposure X-Ray Imaging for High Conspicuity

  • Song, Boram;Kim, Changsoo;Kim, Junwoo
    • Journal of Radiation Protection and Research
    • /
    • 제46권4호
    • /
    • pp.160-169
    • /
    • 2021
  • Background: Dual-energy X-ray images (DEI) can distinguish or improve materials of interest in a two-dimensional radiographic image, by combining two images obtained from separate low and high energies. The concepts of DEI performance describing the performance of double-exposure DEI systems in the Fourier domain been previously introduced, however, the performance of double-exposure DEI itself in terms of various parameters, has not been reported. Materials and Methods: To investigate the DEI performance, signal-difference-to-noise ratio, modulation transfer function, noise power spectrum, and noise equivalent quanta were used. Low- and high-energy were 60 and 130 kVp with 0.01-0.09 mGy, respectively. The energy-separation filter material and its thicknesses were tin (Sn) and 0.0-1.0 mm, respectively. Noise-reduction (NR) filtering used the Gaussian-filter NR, median-filter NR, and anti-correlated NR. Results and Discussion: DEI performance was affected by Sn-filter thickness, weighting factor, and dose allocation. All NR filtering successfully reduced noise, when compared with the dual-energy (DE) images without any NR filtering. Conclusion: The results indicated the significance of investigating, and evaluating suitable DEI performance, for DE images in chest radiography applications. Additionally, all the NR filtering methods were effective at reducing noise in the resultant DE images.

델파이 기법을 이용한 원전사고의 종합적인 경제적 리스크 평가 (A Study on the Overall Economic Risks of a Hypothetical Severe Accident in Nuclear Power Plant Using the Delphi Method)

  • 장한기;김주연;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제33권4호
    • /
    • pp.127-134
    • /
    • 2008
  • 울진원전 3,4 호기의 가상적 중대사고로 인한 종합적인 경제적 리스크를 평가하였다. 이 연구의 목적을 위해 방사능 구름이 내륙을 향하는 것으로 가정하였다. 평가과정에서 불확실한 인자의 정량화에는 전문가 판단 및 의견도출에 유용한 것으로 알려진 델파이 기법을 이용하였다. 종합적인 경제적 리스크는 직접영향 비용과 간접영향 비용으로 구분되므로, 먼저 직접영향에 대한 비용을 평가하고, 예측된 가중치들 이용하여 직접영향 대비 간접영향 비용을 평가하였다. 행동학적 접근방법인 델파이 문제점을 보완하기 위해 수학적 접근방법인 베이지안 기법을 자료처리 과정으로 하는 모형을 적용하여 간접영향에 대한 경제적 충격량을 예측하였다. 1D 몬테칼로분석(MCA)으로 평가한 간접피해에 대한 가중치는 평균 2.59, 중앙값 2.08로 OECD/NEA에서 제시하는 가중치 1.25보다 높게 나타났다. 작은 국토나 방사선에 민감한 대중 성향과 같은 인지들이 패널의 판단에 영향을 미쳤을 수 있다. 직접피해 평가모델의 모수를 U형과 V형으로 구분하고 2D MCA를 사용한 종합적 경제적 리스크는 중앙값의 50%ile을 기준으로 2006년 국내총생산의 3.9%에 해당되었으며, 직접피해 영향이 가장 큰 자산 및 전력손실 비용을 제외하면 총 경제적 리스크는 국내총생산의 2.2% 수준이었다. 이 결과는 원전 비상계획과 대응태세 준비에 대한 투자 정당화에 참조 자료로 이용될 수 있다.

15 MV를 이용한 전립샘암 세기조절 방사선치료 시 빔의 개수에 따른 부작용 발생률에 관한 연구 (A Study on the Incidence of Side Effects according to the Number of Beams in Intensity-modulated Radiation Therapy for Prostate Cancer using 15 MV)

  • 이주아
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.481-487
    • /
    • 2023
  • 본 연구에서는 15 MV를 이용한 전립샘암의 세기조절방사선치료 시 빔의 개수에 따른 광중성자선량의 부작용 발생률을 분석하고자 한다. 전립샘암 세기조절방사선치료의 방사선치료계획설계는 1회 처방선량 220 cGy, 전체 치료 횟수는 33회로 총 7260 cGy로 수립하였다. 실험에 사용된 선형가속기는 Varian의 True Beam STx(Varian, USA)이며, 계획용 표적체적(Planning target volume; PTV)에 15 MV로 광중성자 선량이 발생되도록 하였다. 치료계획의 설계는 Eclipse System (Varian Ver 10.0, USA)을 사용하여 세기조절방사선치료 5, 7, 9 portals로 하였다. 광중성자 선량 측정을 위해 광자극발광선량계 (Optically stimulated luminescence albedo neutron dosimeter, Landauer Inc., USA)를 사용하였다. 세기조절방사선치료 5 portals 시 1,000명당 1.7명, 7 portals 시 1,000명당 1.8명, 9 portals 시 1,000명당 2.0명이 광중성자 선량으로 인하여, 갑상샘에 부작용을 나타낼 확률임을 산출하였다. 본 연구는 세기조절방사선치료 시 2차 피폭선량의 위험성을 연구하여, 향후 방사선의 확률적 영향과 관련된 의미 있는 자료로 활용될 수 있기를 기대한다.

간원개에 위치한 종양에 대한 Anisotropic Analyticalal Algorithm과 Pencil Beam Convolution 알고리즘에 따른 전달선량 비교 (Comparison of Dose Distributions Calculated by Anisotropic Analytical Algorithm and Pencil Beam Convolution Algorithm at Tumors Located in Liver Dome Site)

  • 박병도;정상훈;박성호;곽정원;김종훈;윤상민;안승도
    • 한국의학물리학회지:의학물리
    • /
    • 제23권2호
    • /
    • pp.106-113
    • /
    • 2012
  • 본 연구에서는 종양이 간원개에 위치한 환자들을 대상으로 Eclipse 치료계획시스템(treatment planning system V8.9 : TPS, Varian)에서 쓰이는 두 종류의 선량계산 알고리즘(pencil beam convolution : PBC, anisotropic Analytical algorithm : AAA)들을 적용하여 육안적종양체적(gross tumor volume : GTV), 내부표적체적(internal target volume : ITV), 계획용표적체적(planning target volume : PTV) 및 주요 관심장기에 전달되는 선량의 변화를 정량적으로 평가하고, 선량분포에 영향을 미칠 수 있는 인자들을 분석하고자 하였다. 본원에서 치료받은 간암환자 20명을 대상으로 하였고 그 중 10명의 환자들에 대해서는 정위적 방사선치료(stereotactic body radiation therapy : SBRT) 기술을 적용, 다른 10명의 환자들에 대해서는 3차원 입체조형 방사선치료(three-dimensional conformal radiation therapy : 3DCRT) 기술을 적용하여 치료하였다. 조사선량은 우선적으로 PBC 알고리즘을 적용하여 선량계산을 하였고 동일한 빔 정렬 및 콜리메이터(Collimator), Monitor Unit (MU) 그리고 Field 가중치를 적용시켜서 AAA 선량계산법으로 다시 계산 한 후, 두 알고리즘에 대한 처방선량 100%에 해당하는 체적(V100)의 lesion coverage factor (CVF) 들을 비교하였다. SBRT 기술을 이용한 환자들의 치료계획에서 전체 PTV에 대한 CVF의 경우, 두 선량계산 알고리즘사이 통계학적으로 유의한 상관관계(p=0.018)를 보였다. 또한, 3DCRT 기술을 이용한 환자들의 치료계획에서는 전체 PTV (p=0.006), 간원개에 위치한 PTV (p=0.013), 전체 ITV (p=0.024)에 대하여 각각 통계학적으로 유의한 상관관계를 보였다. 복부에 위치한 주요 관심장기에 대하여 SBRT 기술을 이용한 환자들의 치료계획에서 정상 간과 신장에 조사되는 최대선량에 대하여 통계학적으로 각각 유의한 상관관계(정상간: p=0.009, 신장: p=0.037)를 보였다. 본 연구에서 선택한 선량변화 예측인자들에 대하여 대응표본 T-검정(paired T-test)을 시행한 결과, 전체 PTV에 대한 간원개에만 위치하는 PTV의 비율($PTV_{dome}$/PTV)과 두 알고리즘에 의한 CVF 비율의 상관관계에 있어서 통계학적으로 유의미한 상관관계를 보였다(p<0.01). 또한, 종양의 크기에 대한 두 알고리즘의 CVF 비율에 있어서 통계학적으로 의미가 있는 상관관계를 보였다(SRS환자 p=0.017, 3DCRT환자 p=0.023). 본 연구에서는 15MV x-ray beam으로 선량을 계산할 때 PBC와 AAA간의 선량계산 차이를 분석하여 선택한 선량변화 예측인자 중 간원개에 위치한 종양의 크기와 계획용 표적체적에 대한 관계성을 알아내었다. 일반적으로 15MV x-ray beam에 의한 선량분포를 정확하게 알아내는 것은 AAA으로도 불충분하다는 것이 일반적인 사실로 받아들여지고 있어 이를 AAA와 PBC간의 차이로 그 정확성을 간접적으로 유추하여 실질적인 선량분포에 대한 치료계획단계에서의 선량분포의 차이의 경향성을 보고자 하였다.