• Title/Summary/Keyword: radiation graft

Search Result 116, Processing Time 0.024 seconds

Preparation of Anion-exchange Membrane for Selective Separation of Urea and Ion (요소(Urea) 및 이온의 선택적 분리를 위한 음이온교환막의 제조)

  • Kim, Byoung-Sik;Kim, Min;Heo, Kwang-Beom;Hong, Joo-Hee;Na, Won-Jae;Kim, Jae-Hun
    • Applied Chemistry for Engineering
    • /
    • v.17 no.3
    • /
    • pp.303-309
    • /
    • 2006
  • In this study, functional anion-exchange membranes have been prepared and characterized to improve the permeation fluxes of the anion and urea for peritoneum dialysis. They were prepared by UV and radiation graft polymerization methods. The separation-membrane prepared by UV graft polymerization showed the highest grafting degree when HEMA and VBTAC were mixed by 1:2 ratio. However, the grafting degree decreased slightly at compositions above the 1:2 ratio because of the disruption of UV penetration caused by build-up of homopolymer. In the case of photo-initiator, the grafting degree increased up to 0.2 wt%, above which it decreased to a small extent. For the two membranes prepared by radiation graft polymerization, the VBTAC/HEMA membrane showed 96% grafting degree for 6 h reaction time and the GMA membrane showed over 100% grafting degree for 2 h reaction time. Anion-exchange membranes were prepared with 113% grafting degree and with DEA and TEA exchange groups. The DEA membrane showed the conversion degree of 70% in 4 h reaction time while the TEA membrane showed 30% in 2 h reaction time. The prepared anion-exchange membranes were permeable to only anions and urea, but not cations.

Preparation of Acrylic Acid-grafted Kenaf Fibers Using E-beam Irradiation and Evaluation of Permeability of Kenaf Fiber-cement Composites (전자선을 이용한 아크릴산 그라프트 케냐프 섬유의 제조 및 이를 이용한 케냐프 섬유보강 시멘트의 투수특성 평가)

  • Kim, Du Yeong;Jeun, Joon Pyo;Kim, Hyun Bin;Oh, Seung Hwan;Kang, Phil Hyun
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.53-57
    • /
    • 2014
  • The kenaf is quickly developing as a renewable resource. Kenaf can be grown under a wide range of weather conditions. Modification of kenaf fiber by graft polymerization provides a significant route to alter the chemical properties, including surface hydrophilicity or hydrophobicity. In this study, kenaf fiber surfaces were grafted with acrylic acid as a hydrophilic group using electron beam irradiation. The grafting rate increased with an increase in grafting time. The FT-IR results confirmed that acrylic acid was successfully grafted onto the kenaf fibers. The wettability of the kenaf fiber was increased, accompanied by acylic acid grafting on the fiber surface. According to the permeability test result, it was found that acrylic acid grafted kenaf fiber reinforced cement composite was more reduced than non-grafted kenaf fiber reinforced cement composite.

Radiolytic Immobilization of Lipase on Poly(glycidyl methacrylate )-grafted Polyethylene Microbeads

  • Choi Seong-Ho;Lee Kwang-Pill;Kang Hee-Dong;Park Hyun Gyu
    • Macromolecular Research
    • /
    • v.12 no.6
    • /
    • pp.586-592
    • /
    • 2004
  • Poly(glycidyl methacrylate)-grafted polyethylene microbeads (POPM) presenting epoxy groups were prepared by radiation-induced graft polymerization of glycidyl methacrylate on the polyethylene microbead. The obtained POPM was characterized by IR spectroscopic, X-ray photoelectrons spectroscopy (XPS), scanning electron microscope (SEM), and thermal analyses. Furthermore, the abundance of epoxy groups on the POPM was determined by titration and elemental analysis after amination. The epoxy group content was calculated to be in the range 0.29-0.34 mmol/g when using the titration method, but in the range 0.53-0.59 mmol./g when using elemental analysis (EA) after amination. The lipase was immobilized to the epoxy groups of the POPM under various experi­mental conditions, including changes to the pH and the epoxy group content. The activity of the lipase-immobilized POPM was in the range from 160 to 500 unit/mg-min. The activity of the lipase-immobilized POPM increased upon increasing the epoxy group content. The lipase-immobilized POPM was characterized additionally by SEM, elec­tron spectroscopy for chemical analysis (ESCA), and EA.

Introduction of Various Amine Groups onto Poly(glycidyl methacrylate)-g-MWNTs and their Application as Biosensor Supports (폴리(글리시딜 메타크릴레이트)가 그래프트된 다중벽 탄소나노튜브에 다양한 아민 그룹의 도입과 바이오센서 지지체로서의 응용)

  • Chung, Da-Jung;Kim, Ki-Chul;Choi, Seong-Ho
    • Polymer(Korea)
    • /
    • v.36 no.4
    • /
    • pp.470-477
    • /
    • 2012
  • A tyrosinase-immobilized biosensor was developed based on various amine-modified multi-walled carbon nanotube (MWNT) supports for the detection of phenolic compounds. MWNTs with various amine groups were prepared by radiation-induced graft polymerization of glycidyl methacrylate (GMA) onto MWNT supports and the subsequent amination of poly(GMA) graft chains. The physical and chemical properties of the poly(GMA)-grafted MWNT supports and the aminated MWNT supports were investigated by SEM, XPS, and TGA. Furthermore, the electrochemical properties of the prepared tyrosinase-modified biosensor based on MWNT supports with amine groups were also investigated. The response of the enzymatic biosensor was in the range of 0.1-0.9 mM for the concentration of phenol in a phosphate buffer solution. Various parameters influencing biosensor performance have been optimized: binder effects, pH, temperature, and the response to various phenolic compounds. The biosensor was tested on phenolic compounds contained in two different commercial red wines.

Improvement of Shoulder Motion in Two-Stage Dual-Plane Implant-Based Breast Reconstruction followed by Radiation Therapy through Delayed Prepectoral Conversion

  • Jin Sol Park;Ung Sik Jin
    • Archives of Plastic Surgery
    • /
    • v.51 no.1
    • /
    • pp.52-61
    • /
    • 2024
  • Background Although prepectoral implant-based breast reconstruction has recently gained popularity, dual-plane reconstruction is still a better option for patients with poor-quality mastectomy skin flaps. However, shoulder morbidity is aggravated by subpectoral reconstruction, especially in irradiated patients. This study aimed to demonstrate shoulder exercise improvement in subpectoral reconstruction by delayed prepectoral conversion with an acellular dermal matrix (ADM) inlay graft technique at the time of expander-to-implant exchange after irradiation. Methods Patients with breast cancer treated for expander-to-implant exchange after subpectoral expander insertion and subsequent radiotherapy between January 2021 and June 2022 were enrolled. An ADM inlay graft was inserted between the pectoralis major muscle and the previously inserted ADM. The ADM was sutured partially overlapping the pectoralis muscle from the medial side with the transition part, to the muscle border at the lateral side. Perioperative shoulder joint active range-of-motion (ROM) for forward flexion, abduction, and external rotation was also evaluated. Results A total of 35 patients were enrolled in the study. Active shoulder ROM significantly improved from 163 degrees preoperatively to 176 degrees postoperatively in forward flexion, 153 to 175 degrees in abduction, and 69 to 84 degrees in external rotation. There was no difference in patient satisfaction regarding the final outcome between the conventional prepectoral reconstruction group and the study group. Conclusion Shoulder exercises in irradiated patients who underwent subpectoral reconstruction were improved by delayed prepectoral conversion using an ADM inlay graft. It is recommended that subpectoral reconstruction not be ruled out due to concerns regarding muscle contracture and shoulder morbidity in radiation-planned patients with poor mastectomy skin flaps.

Characterization and Performance of MEA for Direct Methanol Fuel Cell Prepared with PFA Grafted Polystyrene Membranes via Radiation-Grafting Method (방사선 그라프트 PFA-폴리스티렌 멤브레인으로 제조한 직접 메탄올 연료전지용 MEA의 성능과 특성)

  • Kang, Se-Goo;Peck, Dong-Hyun;Kim, Sang-Kyung;Lim, Seong-Yop;Jung, Doo-Hwan;Park, Young-Chul;Shin, Jun-Hwa;Kang, Phil-Hyun;Nho, Young-Chang;Shul, Yong-Gun
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.2
    • /
    • pp.173-180
    • /
    • 2009
  • In order to develop a novel polymer electrolyte membrane for direct methanol fuel cell (DMFC), styrene monomer was graft-polymerized into poly(tetrafluoroethylene perfluoropropyl vinyl ether) (PFA) film followed by a sulfonation reaction. The graft polymerization was prepared by the $\Upsilon$-ray radiation-grafting method. Subsequently, sulfonation of the radiation-grafted film was carried out in a chlorosulfonic acid/1,2-dichloroethane (2 v/v%) solution. The chemical, physical, electrochemical and morphological properties of the radiation-grafted membranes (PFA-g-PSSA) were characterized by fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM). The water uptake, ionic conductivity, and methanol permeability of the PFA-g-PSSA membrane were also measured. The cell performances of MEA prepared with the PFA-g-PSSA membranes were evaluated and the cell resistances were measured by an impedance analyzer. The MEA using PFA-g-PSSA membranes showed superior performance for DMFCs in comparison with the commercial Nafion 112 membrane.

V-Y Latissimus Dorsi Musculocutaneous Flap for Reconstruction of Radiation-induced Skin Injuries on the Back (V-Y 광배근피판을 이용한 등의 방사선 유발 피부 손상의 치험)

  • Shim, Seung-Hyun;Chung, Chul-Hoon;Kim, Kuyl-Hee
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.707-710
    • /
    • 2011
  • Purpose: Cardiac radiofrequency catheter ablation procedures using fluoroscopy were performed for the treatment of supraventricular and selected ventricular tachyarrhythmia. Fluoroscopy is used to localize the position of the intracardiac catheter. Fluoroscopically-guided procedures often involve high radiation doses to patient's skin, but the incidence of serious radiation injuries in these patients is rare. We reported two cases of severe postradiation skin injury on the back treated with the V-Y latissimus dorsi musculocutaneous flap. Methods: These two patients underwent radiofrequency catheter ablation under the diagnosis of Woff Parkinson White syndrome (WPW syndrome). They had radiation-induced skin injuries on the subscapular area and these lesions represented chronic ulceration, surrounding induration, hardness, and dyspigmentation. We treated these lesions with complete excision and coverage with V-Y latissimus dorsi musculocutaneous flap. Results: These two patients had no recurrence and no special complications during 20 months and 12 months follow-up periods and were satisfied aesthetically and functionally. Conclusion: V-Y latissimus dorsi musculocutaneous flap obtained better results functionally and aesthetically compared with conservative management and skin graft in severe radiation-induced skin injuries after cardiac radiofrequency catheter ablation procedure.

Preparation of Cement Composites Containing Kenaf Fiber Has Been Gamma-ray Grafted with Poly(ethylene glycol) Methacrylate (감마선 조사를 이용하여 Poly(ethylene glycol) Mathacrylate가 그래프팅된 케냐프 섬유를 포함하는 시멘트 복합재료의 제조)

  • Lee, Byoung-Min;Kang, Phil-Hyun;Jeun, Joon Pyo
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.49-52
    • /
    • 2014
  • Kenaf fibers have excellent properties and possess the potential to be outstanding reinforcing fillers in cement. The grafting of poly(ethylene glycol) methacrylate (PEGMA) to the kenaf fibers is important in improving the compatibility between the fibers and the cement. PEGMA was grafted onto kenaf fibers using gamma-ray radiation. The radiation dose ranged from 20 to 60 kGy, and the dose rate was $10kGy\;h^{-1}$. The degree of grafting increased with increased radiation doses. FT-IR analysis revealed an increase in PEGMA content after gamma-ray radiation induced grafting, further evincing the attachment of PEGMA to the kenaf fibers. The mechanical properties of the gamma-ray grafted kenaf fiber/cement composites were superior to those of the ungrafted kenaf fiber/cement specimens.