• 제목/요약/키워드: radiation discharge

검색결과 170건 처리시간 0.031초

절연유에서 부분방전에 의한 극초단파 신호 특성분석 (Signal Characteristics of Ultra-high Frequency Radiation from Partial Discharge in Insulation Oil)

  • 주형준;구선근;박기준;한기선;윤진열
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.56-59
    • /
    • 2008
  • We have designed 4 types(void in insulation paper, protrusion electrode, floating electrode, surface discharge) of partial discharge(PD) defect to simulate typical faults found in oil filled power transformers. Ultra-high frequency(UHF) radiation due to PD was measured using a UHF measuring system and a conventional PD measuring system, simultaneously. Electromagnetic radiation spectra of these defects show UHF radiation up to about 1.5-2 GHz range. The phase resolved partial discharge(PRPD) patterns of UHF radiation from the PD defects were also measured and the pattern reveals distinct feature for each defect types. The UHF measuring could be used to detect PDs in oil filled transformers and analysis of the PRPD pattern should provide useful information on origin of PD signal.

인가 전압의 변화에 따른 FFL(Flat Fluorescent Lamp)의 방전특성 (Discharge characteristics of FFL as applied voltage variation)

  • 윤성현;박철현;조민정;임민수;권순석;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.379-382
    • /
    • 2000
  • The characteristics of Xe discharge lamp(Mercuryless lamp) are described in this paper. In this paper, FFL is operated by sine wave and pulsed source. We apply V-Q Lissajous' figure for the discharge measurements of FFL which has the electrodes covered with dielectric. When FFL is operated by sine wave source, the characteristics are similar to DBD(Dielectric Barrier Discharge) and SD(Silent Discharge). And we compared the characteristics of FFL which is operated with sine wave and pulsed discharge by using V-Q Lissajous' figure method. When FFL is operated with pulsed, the discharge current flows after the applied voltage is risen. As the duty ratio increases the electric field becomes strong and much more xenon ions are produced. And the number of metastable xenon atoms seem to increase, therefore, the phosphor radiation after the cut off of voltage increases compared with the first peak of radiation. Consequently, the 172㎚ radiation becomes strong as the duty ratio increases.

  • PDF

펄스형 $CO_2$ 레이저를 이용한 기중 침 대 침 전극간의 유도방전 특성 (The induced discharge characteristics in atmosphere adopting a pulsed $CO_2$ laser)

  • 정용호;최진영;이유수;정현주;송건주;김희제
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.172-175
    • /
    • 2002
  • The technique of induced discharge by a pulsed CO2 laser is being applied to control electrical discharge path, material processing, triggered lightning for protecting the power equipments. In this paper, we have investigated about the characteristics of the induced discharge at atmospheric conditions by using a plasma channel, which is produced when a pulsed CO2 laser radiation is focused by a focusing mirror as a trigger source. A plasma channel produced by laser radiation has an effect on decreasing the threshold voltage and inducing the discharge in both needle electrodes. We have confirmed a delay time between a produced plasma channel and an electrical discharge after laser radiation. We provided the decreased voltage lower than the natural discharge voltage between electrode type of needles and was induced the discharge by forming a plasma channel between them. In this research we could understand the time delay of induced discharge by laser radiation, and the characteristics of the discharge cause by the decrease in the threshold voltage, and the polarity effect by changes of plasma channel positions between two electrodes.

  • PDF

AC PDP 셀에서 Resonance Radiation Trapping을 고려한 방전 특성해석 (Effect of Resonance Radiation Trapping on Xe discharge in AC PDP Cell)

  • 김정호;정희섭;이병호;황기웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.990-992
    • /
    • 1998
  • Resonance radiation trapping has a great influence on the characteristics of gas discharge. We calculate the spatial and spectral distribution of photons by Monte Carlo method in AC PDP cell.

  • PDF

Characteristics of Laser-Guided DC Discharge by Nd: YAG Laser at Low Pressure

  • Lee, Dong-Hoon;Kim, Hee-Je
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권3호
    • /
    • pp.316-321
    • /
    • 1998
  • In recent years, concern has been raised about the technique of controlling electrical breakdown by using laser in many fields. Especially, laser has attracted much attention in the Electro-Discharge Macining(EDM) because of its many merits. Therefore, this research has been performed to obtain fundamental data relevant to discharge processing by using a pulsed Nd:YAG laser. The experiments of laser-guided dc discharge by laser radiation have been carried out at low air pressure ranging from 0.2 to 20 torr. The minimum laser-guided dc discharge voltage V\ulcorner at the given pressures P and distances D between an anode and a cathode was measured. It is found that the minimum laser-guided dc discharge voltage is much lower than the natural discharge voltage V\ulcorner\ulcorner, and the values of V\ulcorner and V\ulcorner as a function of P.D has a similar tendency. The laser output energy Eout decreases with input pulse duration tp increasing, and the more the value of tp increases, the higher that of V\ulcorner is obtained because the number of photons during the discharge time N decreases with t\ulcorner increasing. There is the time lag frequently when the discharge by laser radiation is misguided under the condition of the applied voltage less than V_G.min.

  • PDF

고속 방전·충전 스위칭 전원차단회로 설계 제작 및 특성분석 (Implementation of crowbar circuit for high-speed discharge·charge switching and its characteristic analysis)

  • 이민웅;조성익;이남호;정상훈
    • 한국정보통신학회논문지
    • /
    • 제21권5호
    • /
    • pp.885-892
    • /
    • 2017
  • 본 논문에서는 기존 전원차단회로의 공급전원 차단 복귀 시간 지연 문제를 해결하기 위하여 고속 방전 충전 스위칭 기능을 갖는 새로운 전원차단회로를 제안하였다. 제안된 전원차단회로는 공급전원 고속 차단 후 복귀(충전) 속도를 증가시키도록 설계함으로써 전자시스템의 방사선 노출 시간과 펄스 방사선이 지나간 후 정상동작하기 위한 시간을 줄였다. 하드웨어를 구현하기 전 방전 충전 시간의 시뮬레이션은 Cadence 사의 pspice tool을 이용하여 진행하였으며 소자레벨에서 DUT(Device Under Test) 보드를 제작하였다. 전원차단회로의 비교 측정은 24V용 인공위성 전자소자를 대상으로 수행되었다. 그 결과, 제안된 회로는 기존 회로에 비하여 방전속도 96.8%, 복귀속도 27.3% 향상으로 고속 기능이 구현됨을 확인하였다.

광촉매와 조합된 코로나 방전 플라즈마 필터의 유해 가스 및 입자 제거 특성 (A Compact Pulse Corona Plasma System with Photocatalyst for an Air Conditioner)

  • 신수연;문재덕
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.151-155
    • /
    • 2007
  • A compact discharge plasma system with a photocatalyst has been proposed and investigated experimentally for application to air conditioners. It was found that there was intense ultra violet radiation with high energy of 3.2 eV from the corona discharge due to the DC-biased pulse voltage applied on a wire. An electrophotochemical reaction took place apparently on the surfaces of the photocatalyst of $TiO_2$ irradiated ultra violet front the discharge plasma in the proposed plasma system. The proposed discharge plasma system with the photocatalyst of $TiO_2$ showed very high removal efficiency of VOCs by tile additional electrophotochemical reactions on the photocatalyst. The proposed discharge plasma system also showed very high removal efficiency of particles such as smokes, suspended bacteria, and pollen and mite allergens by the electrostatic precipitation part. This type of corona discharge plasma system with a photocatalyst can be used as an effective means of removing both indoor pollutant gases and particles including suspended allergens.

조선대학교 사이클로트론 시설의 RI 배기필터 성능평가 및 18F 배출저감 연구 (Performance of the RI Exhaust Filter at Chosun University Cyclotron Facility and 18F Emission Reduction)

  • 정철기;장한;이경진
    • 방사선산업학회지
    • /
    • 제11권1호
    • /
    • pp.13-18
    • /
    • 2017
  • Recently, the number of PET cyclotrons has increased in Korea. A cyclotron mainly produces $^{18}F$, which is used for the production of [$^{18}F$]FDG, a cancer diagnostic radiopharmaceutical. For radiation protection, the discharge control standard under the Nuclear Safety Act limits the radioactive concentration of $^{18}F$ in the exhaust discharged from a nuclear power utilization facility to below $2,000Bq\;m^{-3}$. However, the radioactive concentration of $^{18}F$ discharged during [$^{18}F$]FDG production at the cyclotron facility at Chosun University is maintained at about $1,500Bq\;m^{-3}$ on average, which is 75% of the concentration limit of the discharge control standard, and temporarily exceeds the standard as per the real-time monitoring results. This study evaluated the performance of the exhaust filter unit of the cyclotron facility at Chosun University by assessing the concentration of $^{18}F$ in the exhaust, and an experiment was conducted on the discharge reduction, where $^{18}F$ is discharged without reacting with the FDG precursors during [$^{18}F$]FDG synthesis and is immediately captured by the [$^{18}F$]FDG automatic synthesis unit. Based on the performance evaluation results of the exhaust filter at the cyclotron facility of Chosun University, the measured capture efficiency before and after the filter was found to be 92%. Furthermore, the results of the discharge reduction experiment, where the exhaust $^{18}F$ was immediately captured by the [$^{18}F$]FDG synthesizer, showed a very satisfactory 94.3% reduction in the concentration of discharge compared to the existing discharge concentration.

Environment Assessing for Airborne Radioactive Particulate Release-introduction of Methods in IAEA Safety Report Series No.19

  • Meng, Dan;Yang, Liu;Shen, Fu;Yang, Yi;Ma, Yinghao;Ma, Tao;Zhang, Zhilong;Fu, Cuiming
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.409-417
    • /
    • 2016
  • Background: Airborne radioactive particulate in many important nuclear facilities (particularly nuclear power plants) will have a strong impact on the relative public dose if they are released into the corresponding environment traversing the stack or vents. The radiation protection researchers have regarded the relative environment assessing and estimation of public doses. And the model of assessing impact of discharges radioactive substance to the environment have been recommended by many international organizations (e.g. IAEA) with the nuclear energy safety and radiation protection. Materials and Methods: This paper introduced the generic models that were suggested by International Atomic Energy Agency (IAEA), for use in assessing the impact of discharges of radioactive substances to the environment (e.g. IAEA Safety Report Series No.19). Results and Discussion: The writers of this paper, based on the recommend methods, assessed the discharge limits in some airborne radioactive substances discharging standards. The reasons that IAEA method are introduced are mainly the following considerations: IAEA is one of international organizations with some authorities in the nuclear energy safety and radiation protection; and, more important, the recommend modes are operational methods rather than the methods having little operations such as that have used by some researchers. Conclusion: It is wish that the introduced methods in this paper can be referenced in draft or revise of the standards related to discharges of radioactive substances to the environment.

폼 분무 노즐 방사 분포 및 폼의 열적 특성 연구 (Thermal Characteristics of Foams and Discharge of Fire-Protection Foam Spray Nozzle)

  • 김홍식;김윤제
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.151-158
    • /
    • 2005
  • A characteristic of discharge for a foam spray nozzle with various parameters was investigated. The discharge patterns from a fire foam spray nozzle are important to evenly spray over a maximum possible floor area. Two parameters of a foam spray nozzle were chosen, and compared with those from the standard one. Also, in order to evaluate the performance of discharged foam agents used to protect structures from heat and fire damages, the thermal characteristics of fire-protection foams were experimentally investigated. A simple repeatable test for fire-protection foams subjected to fire radiation was developed. This test involves foam generation equipment, a fire source for heat generation, and data acquisition techniques. Results show that the bubble size of foam is increased by large inside diameter of orifice or closed air hole, but phenomenon of discharge angle and expansion ratio is opposite. For the case of the open air hole, liquid film of a circular cone discharges with formation, growth, split and fine grain. In case of the closed air hole, a pillar of foam solution discharges with that. Though the temperature gradient in the foam increases with increased foam expansion ratio. it is not change with increased intensity of heat flux.