• 제목/요약/키워드: radiation detector

검색결과 843건 처리시간 0.021초

Gamma/neutron classification with SiPM CLYC detectors using frequency-domain analysis for embedded real-time applications

  • Ivan Rene Morales;Maria Liz Crespo;Mladen Bogovac;Andres Cicuttin;Kalliopi Kanaki;Sergio Carrato
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.745-752
    • /
    • 2024
  • A method for gamma/neutron event classification based on frequency-domain analysis for mixed radiation environments is proposed. In contrast to the traditional charge comparison method for pulse-shape discrimination, which requires baseline removal and pulse alignment, our method does not need any preprocessing of the digitized data, apart from removing saturated traces in sporadic pile-up scenarios. It also features the identification of neutron events in the detector's full energy range with a single device, from thermal neutrons to fast neutrons, including low-energy pulses, and still provides a superior figure-of-merit for classification. The proposed frequency-domain analysis consists of computing the fast Fourier transform of a triggered trace and integrating it through a simplified version of the transform magnitude components that distinguish the neutron features from those of the gamma photons. Owing to this simplification, the proposed method may be easily ported to a real-time embedded deployment based on Field-Programmable Gate Arrays or Digital Signal Processors. We target an off-the-shelf detector based on a small CLYC (Cs2LiYCl6:Ce) crystal coupled to a silicon photomultiplier with an integrated bias and preamplifier, aiming at lightweight embedded mixed radiation monitors and dosimeter applications.

Wedge Filter가 주변선량분포에 주는 영향에 관한 연구 (A Study on the Effects of Wedge Filter in Peripheral Dose Distribution)

  • 강위생;김일한;박찬일
    • Radiation Oncology Journal
    • /
    • 제3권2호
    • /
    • pp.145-151
    • /
    • 1985
  • Wedge filter를 사용할 때 $^{60}Co\;\gamma$선과 10MV X-선의 주변선량분포를 반자동식 물팬톰장치에 의해 제어되는 고체 방사선검출기로 측정하였다. wedge filter의 날과 등의 방향을 잇는 주단면상에서 주변선량을 측정하였다. 방사선의 투과력과 wedge 각, wedge에 대한 방향, 조사면의 변화에 대하여 주변선량의 면화를 고찰하였다. 선축에 수직인 방향의 측정은 깊이 dm, 5cm, 10cm, 15cm에서 선측과 평행인 방향에서는 조사면 경계에서 3cm, 5cm, 10cm 떨어진 위치에서 측정이 이루어졌다. 측정으로부터 wedge가 사용되는 조사면에 대한 주변선량분포가 아래와 같음을 볼 수 있었다. 1. wedge filter의 날의 방향의 주변선량이 등의 방향의 주변선량보다 높았다. 2. 표면근처에서는 깊이가 깊어짐에 따라 선량이 감소하였다. 3. $^{60}Co\;\gamma$선의 경우 어떤 깊이에서는 조사면의 경계로부터 거리가 떨어짐에 따라 주변선량이 단조감소하지 않고 다시 증가하는 영역이 있었다. 4. wedge를 사용하는 경우 주변선량은 방사선의 투과력이나 조사면의 크기뿐만 아니라 wedge의 각과 방향에도 영향을 받는다.

  • PDF

Fluence Monitor를 이용한 HANARO 노심 내 중성자 플루언스 측정 (Neutron fluence measurement at HANARO using fluence monitor method)

  • 이승규;조광호;주기남;박진석;김용균
    • Journal of Radiation Protection and Research
    • /
    • 제36권4호
    • /
    • pp.200-208
    • /
    • 2011
  • Fluence monitor(F/M)는 조사 시편을 원자로의 노심에 넣은 후 방사화 된 조사 시편의 방사능을 측정한 후 역산하여 중성자의 선량을 계산하는 기법으로 원자로내의 중성자 분포를 조사하기 위하여 반드시 필요한 기술이다. 이 기술은 중성자에 대한 에너지 스펙트럼 측정이 간접적으로 가능하며, 현존하는 중성자 분포 측정 기법 중에서 우수한 정밀도를 지니고 있다. 하나로(HANARO)에서 수행하는 재료조사 시험에서의 중성자량 측정을 위하여 본 연구에서는 지름 0.1 mm, 길이 3 mm 미만의 질량 150~200 ${\mu}g$ 범위, 순도 99.9% 이상의 Fe, Ni, Ti 와이어를 F/M 시편으로 사용하였다. 이 시편은 알루미늄 캡슐에 봉입하여 30 MW 의 하나로 OR5공에 약 25일간 조사하였다. 조사를 마친 시편은 high purity germanium (HPGe) detector를 이용하여 감마선을 측정하였고, SAND-II code로 reaction rate와 중성자 cross-section등을 고려하여 fluence monitor 위치에서의 중성자 플루언스를 계산하였다. F/M이 장착 되었던 하나로 OR5공의 중성자 플루언스 값은 MCNP 코드를 이용하여 계산된 결과를 사용하였으며, SAND-II code로 장착된 F/M 위치에서의 중성자 플루언스를 계산하여 적용된 시편의 reaction에 따른 결과값의 차이를 비교 분석하였다.

운항승무원의 우주방사선 피폭 평가에 있어 누적형 개인 중성자 선량계의 적용가능성 예비 연구 (Preliminary Study on Applicability of Accumulate Personal Neutron Dosimeter for Cosmic-ray Exposure of Aviators)

  • 김형진;장병욱;변종인;송명한;김정호
    • Journal of Radiation Protection and Research
    • /
    • 제38권1호
    • /
    • pp.44-51
    • /
    • 2013
  • 상대적으로 높은 항공승무원의 우주방사선 피폭을 고려하여 ICRP는 직무피폭의 일부로 간주하고 방사선 방호 대상으로 권고하였으며 이미 유럽 등 일부 국가에서는 항공 고도에서의 항공승무원에 대한 우주방사선 피폭 관리가 이루어지고 있다. 국내에서도 2012년 7월 26일 생활주변방사선안전관리법의 시행과 더불어 항공승무원에 대한 관리 기준이 마련되었다. 본 연구에서는 항공승무원의 개인 선량 평가에서 휴대가 용이한 누적형 고체비적검출기의 적용가능성을 검토하기 위해 수행되었다. 한국표준과학연구원에서 $^{252}Cf$ 중성자 표준 선원을 이용해 선량계의 중성자 선량에 대한 반응도의 선형성과 중성자 입사각에 따른 각도의존성을 평가하였고 한국민간항공조종사협회의 협조를 얻어 항공 고도에 선량계를 노출시켰다. 응답 특성 평가 결과, 선형성에서는 각각의 감속재에 대해 모두 상관계수($r^2$)가 0.99 이상으로 높았고 큰 각도의존성을 나타내었다. 또한 예측된 운항 승무원의 중성자 선량과 비적 밀도와의 상관성은 각각의 감속재에 대하여 r=0.486 (HDPE), r=0.241 (PA)으로 낮게 평가되었다. 누적형 중성자 선량계는 개인 피폭 선량 평가에 활용 가능성이 있을 것으로 판단되나 항공 고도에서의 중성자 에너지 스펙트럼을 고려하여 추가적인 연구가 필요하며 노출 시간을 증가시켜 비적 밀도와의 상관성을 보다 면밀하게 평가할 필요가 있다.

한국인 임산부의 흉부 후-전 방향 방사선검사 시 적절한 차폐막 높이 (Optimal Height of Shielding Plate of Radiation in Posteroanterior Chest Radiography for Pregnant Women on Korea)

  • 주영철;김규형
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.97-102
    • /
    • 2018
  • The purpose of this study is to provide the basic data for reducing unnecessary radiation dose to the abdomen and fetus of pregnant women by presenting proper height of shielding protector for efficient abdominal shielding in chest PA examination of Korean pregnant women. The subjects of this study were 288 persons who were eligible for this study among 798 pregnant women who had chest PA examination from January 1, 2015 to December 31, 2016 Retrospective study was performed. Measurements was performed from the apex of the right and left lungs to costophrenic angle of the right and left lungs and to the lowest costophrenic angle among the right and left lungs at the top of the image(this line called Joo's line in this study). The mean of the right and left lung height of pregnant women were 259.09 mm and 263.57 mm, respectively. Also, the average height of the Joo's line designed by the researcher for proper abdominal radiation protection was 322.15 mm. For proper and efficient abdominal radiation protection for pregnant women, it is necessary to adjust the shielding according to the height of the pregnant woman. It is appropriate that the height of the shielding protector should be adjusted so that the upper part of the shield is located at 342.30 mm below from upper part of the detector.

소동물 영상화 및 환경 방사선 검출을 위한 감마카메라 개발 (Development of Gamma Camera System for Small Animal Imaging and Environmental Radiation Detection)

  • 백철하
    • 한국콘텐츠학회논문지
    • /
    • 제14권2호
    • /
    • pp.475-481
    • /
    • 2014
  • 이 연구의 목적은 감마선 검출 시스템을 개발하여 평행구멍형 조준기와 바늘구멍 조준기를 이용하여, 각각 소동물용 감마영상 획득과 환경 방사선 검출 영상을 획득하는 것이다. 본 연구에서는 크기가 $50{\times}50mm$ 이며, 6 mm 두께의 CsI(Tl) 섬광체와 $50{\times}50mm$ 크기의 Hamamatsu H8500C 위치민감형 광전자증배관, 저항분배회로, 전치증폭기, 성형증폭기, NIM 모듈 및 아날로그 디지털 변환기로 구성된 감마카메라를 개발하였다. 또한. 바늘구멍 감마카메라와 전하결합소자 카메라를 결합하여 환경모니터링에 적용할 수 있는 장비를 개발하였다. 본 연구 결과는 평행 구멍형 조준기와 바늘구멍 조준기를 이용한 감마카메라를 각각 소동물용 감마영상 획득과 환경방사선 측정에 적용 할 수 있음을 보여주었다. 이 시스템은 소 동물전용 감마카메라와 환경방사선 측정 시스템으로 활용 될 수 있을 것이다.

치과 영상용 삽입형 초소형 X선 튜브의 가능성 연구 (Feasibility study of insertable miniature x-ray source for dental imaging)

  • 조성호;김소영;안소현;임수미;이레나
    • 한국방사선학회논문지
    • /
    • 제6권1호
    • /
    • pp.39-45
    • /
    • 2012
  • 기존 구내 치근단 촬영용 장치는 환자 피폭선량, 촬영시 고통 등의 문제점을 지니고 있다. 본 연구에서는 이러한 문제점을 해결하기 위한 신개념의 삽입형 초소형 X선 시스템의 가능성을 검증하였다. 먼저 초소형 X선 튜브에 사용될 콜리메이터와 필터를 설계하기 위하여 Geant4를 이용하여 최적의 콜리메이터 두께와 필터 두께를 결정하였으며 CdTe 검출기와 PX4 모듈을 이용하여 결정된 두께에서의 X선 스펙트럼을 확인하였다. 또한 기존 상용화된 치근단 촬영장치와 XOFT사의 초소형 X선 튜브를 이용하여 제작된 치아 팬텀에 대한 영상을 획득하였다. 그 결과 제안된 신개념의 삽입형 초소형 X선 시스템은 기존 시스템과 유사한 영상의 질을 나타내었다. 이는 향후 치근단 촬영용 장치를 비롯하여 다양한 응용부위에 활용할 수 있음을 나타낸다.

DEVELOPMENT AND EVALUATION OF A PHANTOM FOR MULTI-PURPOSE DOSIMETRY IN INTENSITY-MODULATED RADIATION THERAPY

  • Jeong, Hae-Sun;Han, Young-Yih;Kum, O-Yeon;Kim, Chan-Hyeong;Park, Joo-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제43권4호
    • /
    • pp.399-404
    • /
    • 2011
  • A LEGO-type multi-purpose dosimetry phantom was developed for intensity-modulated radiation therapy (IMRT), which requires various types of challenging dosimetry. Polystyrene, polyethylene, polytetrafluoroethylene (PTFE), and polyurethane foam (PU-F) were selected to represent muscle, fat, bone, and lung tissue, respectively, after considering the relevant mass densities, elemental compositions, effective atomic numbers, and photon interaction coefficients. The phantom, which is composed of numerous small pieces that are similar to LEGO blocks, provides dose and dose distribution measurements in homogeneous and heterogeneous media. The phantom includes dosimeter holders for several types of dosimeters that are frequently used in IMRT dosimetry. An ion chamber and a diode detector were used to test dosimetry in heterogeneous media under radiation fields of various sizes. The data that were measured using these dosimeters were in disagreement when the field sizes were smaller than $1.5{\times}1.5\;cm^2$ for polystyrene and PTFE, or smaller than $3{\times}3\;cm^2$ for an air cavity. The discrepancy was as large as 41% for the air cavity when the field size was $0.7{\times}0.7\;cm^2$, highlighting one of the challenges of IMRT small field dosimetry. The LEGO-type phantom is also very useful for two-dimensional dosimetry analysis, which elucidates the electronic dis-equilibrium phenomena on or near the heterogeneity boundaries.

영상처리기반 스테레오 감마선 탐지장치의 고속탐지에 관한 연구 (The Study for the Fast Detection of the Stereo Radiation Detector using the Image Processing)

  • 황영관;이남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.1103-1105
    • /
    • 2015
  • 원전이나 방사선 관련시설에서의 사고발생 또는 노후원전 해체시 누출된 방사능은 조기에 탐지 및 제거해야 대형사고를 방지할 수 있다. 본 논문에서는 방사선원의 빠르고 효율적인 제염작업을 위해 방사선원에 대한 거리, 방향 및 선량정보를 제공할 수 있는 단센서 기반의 스테레오감마선 탐지장치를 구현하였고, 탐지장치의 고속탐지를 위한 알고리즘개발을 수행하였다. 선원에 대한 거리정보를 획득하기 위한 스테레오 구조를 위해 2대의 탐지장치가 필요하지만 장치의 운용을 위하여 단센서 기반의 경량화된 탐지장치를 고안하였고, 스테레오 영상 획득시 탐지시간을 최소화 하기 위하여 관심영역을 추출한 후 해당 영역에 대한 스캔을 통해 탐지 선원에 대한 거리산출 및 영상분포출력을 나타내도록 하였다. 스테레오 획득 시 탐지시간을 기준으로 적용된 알고리즘의 탐지시간은 최대 35%의 시간단축결과를 확인하였다.

  • PDF

Synchrotron Radiation을 이용한 CMOS sensor image 획득평가 (Evaluation of image acquisition using synchrotron radiation in CMOS sensor.)

  • 김대환;박지군;최장용;장기원;윤경준;문치웅;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.396-399
    • /
    • 2003
  • In this paper, the purpose is to develop imaging technique of synchrotron radiation using CMOS image sensor. The detector using hybrid method to be research in this lab was used, in order to increase image signal. We made experiments with 1B2 Whitebeam/microprobe beamline in PAL (Pohang Accelerator Laboratory). Phosphor materials such as ZnS:(Ag,Li), ZnS:(Cu,Al), $Y_2O_2S:Eu$ were produced by spin coating on glass. Synchrotron radiation images were acquired and evaluated from monochromatic light from monochromoator in PAL 1B2line. From obtained object and phantom, MTF was 0.15 in ZnS:(Ag,Li) phosphor, and 0.178 in ZnS:( Cu,Al) at 151p/mm. MTFs were unsystematic because thickness of phosphor and uniformity of surface were not optimized. It's expected to improve MTF and the qualify of images as uniformity's optimized.

  • PDF