Implementation of waste silicate glass into composition of ordinary cement for radiation shielding applications

  • Eid, Mohanad S.;Bondouk, I.I.;Saleh, Hosam M.;Omar, Khaled M.;Sayyed, M.I.;El-Khatib, Ahmed M.;Elsafi, Mohamed
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1456-1463
    • /
    • 2022
  • The aim of this work is to study the radiation shielding properties of cement samples with waste glass incortated into its composition. The mass attenuation coefficient (MAC) of the samples were experimentally determined to evaluate their radiation shielding ability. The experimental coefficient was evaluated using NaI detector for gamma energies between 59.53 keV and 1408.01 keV using different radioactive point sources Am-241, Eu-152, Co-60, and Cs-137, and the gamma transmission parameters half-value layer, mean free path, and transmission factor were calculated. The theoretical coefficient of the composites was determined using Geant4 and XCOM software. The results were also compared against Geant4 and XCOM simulations by calculating the relative deviation between the values to determine the accuracy of the results. In addition the mechanical properties (including Compressive and porosity) as well as the thermogravimetric analysis were tested for the present samples. Overall, it was concluded that the cement sample with 50% waste glass has the greatest shielding potential for radiation shielding applications and is a useful way to reuse waste glass.

사이버나이프 출력인자 분석: 전리함, 다이오드 검출기 및 필름 (Analysis of Relative Output Factors for Cyberknife: Comparison of Son Chambers, Diode Detector and Films)

  • 장지선;신동오;최병옥;이태규;최일봉;김문찬;권수일;강영남
    • 한국의학물리학회지:의학물리
    • /
    • 제17권1호
    • /
    • pp.47-53
    • /
    • 2006
  • 사이버나이프에 대한 정확한 선량측정은 정위방사선수술 전 과정에서 중요한 역할을 하고 있다. 본 연구에서는 여러 가지 검출기를 이용하여 사이버나이프의 상대적인 출력인자 값에 대하여 평가하고자 하였다. 사이버나이프는 12개 조준기를 사용하고 있으며, 이들 조준기에 대한 출력인자 값은 6개의 검출기(다이오드 검출기, X-Omat V 필름, Gafchromic EBT 필름, 0.015 cc, 0.125 cc, 0.6 cc 전리함)를 사용하여 측정하였다. 다이오드 검출기와 전리함은 물팬텀을 이용하여 선원과 표면 간의 거리 80 cm, 최대선량깊이인 1.5 cm에서 측정하였고 필름은 고체팬텀을 이용하여 물팬텀과 동일한 위치에서 측정하였다. 각 조준기의 출력인자는 사이버나이프의 최대 조사면의 크기인 직경 60 mm 조준기의 출력인자 값에 대하여 규격화하였다. 조준기의 크기가 30 mm 이상인 경우 0.6 cc 전리함을 제외하고 다른 검출기에서 0.5% 이내로 상호 잘 일치하였다. 그러나 15 mm 이하의 조준기에서는 출력인자 값이 검출기의 종류에 따라 다소 차이가 있음을 확인하였다. 즉, 다이오드 검출기와 Gafchromic 필름 경우 5 mm 조준기의 출력인자는 각각 $0.656{\pm}0.009$$0.777{\pm}0.013$이었다. 전리함과 다이오드 검출기에서 이러한 차이는 깊이에 따라 선량률 변화가 급격하고 측방쪽으로의 전자평형상태(lateral electronic equilibrium)가 이루어지지 않은 것으로 기인된다. 그러므로 Gafchromic EBT 필름이 사이버나이프 출력인자 값을 결정하는데 다른 검출기에 비하여 보다 정확하다고 사료된다.

  • PDF

Piranha 657의 Internal Detector를 이용한 저에너지에서 유리선량계의 선량 특성에 관한 연구 (Experimental Study with Respect to Dose Characteristic of Glass Dosimeter for Low-Energy by Using Internal Detector of Piranha 657)

  • 손진현;민정환;김현수;유광열;임현수;김정민;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권2호
    • /
    • pp.119-124
    • /
    • 2012
  • 최근 유리선량계는 Thermoluminescent Dosimeter (TLD)와 더불어 진단영역부터 치료영역에까지 즉, 저에너지영역에서부터 고에너지 영역에 걸쳐 광범위하게 흡수선량 측정에 이용되고 있다. 그러나, 유리선량계의 재현성과 에너지 의존성 등 선량특성에 관한 연구 보고는 주로 고에너지 영역에서 이루어진 결과 값들이다. 이는 방사선 선량 측정소자나 측정기들의 특성연구를 137Cs 이나 60Co를 이용하기 때문으로 사료되며 이들은 모두 치료영역에서 사용되는 고에너지 방출 방사선 선원들이다. 따라서, 본 연구에서는 Glass Dosimeter (GD)를 이용하여 진단 영역의 저에너지 방사선 특성을 50kV, 80kV, 100kV 관전압 변화를 주어 측정한 Piranha 선량에 대한 유리선량계의 선형성, 재현성, 시간에 따른 재현성을 실험 평가하였다. 실험 기기 및 방법으로는 진단용 발생장치에서 발생되는 방사선선량 측정은 다기능 QA 측정기(RTI Electronic, Sweden)인 Piranha 657의 internal detector로 측정 하였으며 측정조건은 25mA, 0.02sec, 2.5mAs 그리고 SSD가 100cm일 때 조사면 $10{\times}10cm^2$로 하였다. 유리선량계 총 60개를 50kV, 80kV, 100kV 세 그룹으로 나누고 동일한 조건으로 유리선량계에 조사하였다. 본 실험결과에서 유리선량계의 선형성은 기존 보고된 고에너지 고선량 영역과 같이 저에너지, 저선량에서도 선량에 따른 선형성을 나타냈다. 재현성과 시간에 따른 재현성도 양호하였다. 본 실험결과와 같이 유리선량계는 고에너지영역에서의 선량측정 뿐만 아니라 저에너지의 선량측정도 가능한 선량계임을 알 수 있었다.

직접 및 간접변환 방식의 디지털 유방 X선 촬영시스템의 영상화질 비교 연구 (Comparison Study of Image Quality of Direct and Indirect Conversion Digital Mammography System)

  • 박혜숙;오유나;조희정;김상태;최유나;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제21권3호
    • /
    • pp.239-245
    • /
    • 2010
  • 본 연구의 목적은 직 간접 변환방식 검출기를 사용한 디지털 유방 X선 촬영시스템의 영상 화질을 비교하고 평가함에 있다. 영상의 정량적인 분해능을 나타내는 변조전달함수(MTF), 노이즈 특성을 나타내는 정규화된 잡음력 스펙트럼(NNPS), 그리고 신호 대 잡음비 성능을 나타내는 양자검출효율(DQE)인자를 이용하여 영상 화질평가를 하였다. DQE는 IEC 62220-1-2 규약에 따라 edge 팬텀을 사용한 MTF 도출을 이용하여 계산되었다. 대조도 대 노이즈비(CNR) 측정은 한국의료영상품질관리원에서 제시한 가이드라인에 따라 측정되었다. 직접 변환방식 검출기가 간접 변환방식 검출기에 비해 공간주파수별로 MTF와 DQE 값이 높은 것으로 측정되었다. 동일한 평균유선선량(AGD)일 때 직접 변환방식의 검출기는 더 높은 CNR값을 보였다. 공간주파수별로 높은 DQE 값을 갖는 직접 변환방식 검출기는 디지털 유방 X선 촬영시스템에 있어서 향상된 영상 화질과 적은 환자선량을 제공할 것이다.

자동화장비 계측효율 관리적 측정방법 제안 (A Suggestion for Counting Efficiency Management of the Automation Instrument)

  • 박준모;김한철;최승원
    • 핵의학기술
    • /
    • 제22권2호
    • /
    • pp.105-111
    • /
    • 2018
  • Purpose Quality control of instrument takes up a large part in the Radioimmunoassays. The gamma-ray instrument, which is one of the important instruments in the laboratory, observes the condition and performance of instrument and performs quality control of the instrument by measuring the Normalization, Calibration, Background and etc. However, there are some automation instruments which can't measure the counting efficiency of gamma-ray meters, resulting in insufficient management in terms of performance evaluation of gamma-ray meters. Therefore, the purpose of this paper is to manage the quality control continuously and regularly by suggesting how to measure the counting efficiency of gamma-ray instruments. Materials and Methods In case of a comparative measurement method to a gamma-ray instrument dedicated to nuclear medical examination, the CPM and counting efficiency can be obtained after the measurement of normalization by inserting the I-125 $200{\mu}L$(CPM 50,000~500,000) into the test tube. With this CPM and counting efficiency values, it's possible to calculate the measurement of the DPM value and count the CPM from the automation instrument from the same source, and enter the DPM to calculate the counting efficiency using a comparative measurement method. Another method is to calculate the counting efficiency by estimating the half life using the radiation source information of the tracer in B test reagents of company A. Results According to the calculation formula using the DPM obtained by counting the normalization of gamma-ray meters, the detection efficiency was 75.16% for Detector 1, 76.88% for Detector 2, 77.13% for Detector 3, 75.36% for Detector 4 and 73.2% for Detector 5 respectively. Using another calculation formula estimated from the shelf life, the data of the detection efficiency from Detector 1 to Detector 5 were 74.9%, 75.1%, 76.5%, 74.9% and 73.2% respectively. Conclusion Although the accuracy of counting efficiencies of both methods are insufficient, this is considered to be useful for ongoing management of quality control if counting efficiency is managed after setting the acceptable ranges. For example, if the measurement efficiency is set to 70% or higher, the allowed %difference between measurements is within 3% and the %difference with the detector wall is set within 5%.

이중 산란형 컴프턴 카메라 구성 검출기 성능 평가 (Performance Evaluation of Component Detectors of Double-scattering Compton Camera)

  • 서희;박진형;김찬형;이주한;이춘식;이재성
    • Journal of Radiation Protection and Research
    • /
    • 제35권2호
    • /
    • pp.69-76
    • /
    • 2010
  • 현재 개발중에 있는 이중 산란형 컴프턴 카메라는 두 대의 산란부 검출기(양면 실리콘 스트립 검출기, DSSD)와 하나의 흡수부 검출기(NaI(Tl) 섬광 검출기)로 구성되며, 소형이면서도 높은 영상해상도를 제공할 수 있는 구조를 가지고 있다. 본 연구에서는 이중 산란형 컴프턴 카메라를 구성하고 있는 감마선 검출기들의 에너지 분해능 및 시간 분해능을 평가하고, 산란부 검출기의 에너지 분해능에 영향을 미치는 인자들을 등가 노이즈 전하(equivalent noise charge)를 통하여 분석하였다. DSSD-1은 평균적으로 59.5 keV 피크($^{241}Am$)에 대하여 $25.2keV{\pm}0.8keV$ FWHM의 에너지 분해능을 보였으며, DSSD-2는 $31.8keV{\pm}4.6keV$ FWHM의 에너지 분해능 지니고 있는 것으로 확인되었다. DSSD의 시간 분해능은 57.25 ns FWHM으로 평가되었고, NaI(Tl) 섬광 검출기의 시간 분해능은 7.98 ns FWHM이었다. 또한 이중산란형 컴프턴 카메라를 이용하여 $^{137}Cs$ 점선원에 대한 컴프턴 영상을 획득한 후 성능을 평가하였다. 이번 실험을 통해서 영상해상도 8.4 mm FWHM (각 분해능 $8.1^{\circ}$ FWHM)을 획득하였고, 영상감도는 $1.5{\times}10^{-7}$(고유 효율=$1.9{\times}10^{-6}$)으로 나타났다.

비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기와 X-ray film과의 MTF측정을 통한 영상 질(quality) 비교평가에 관한 연구 (Comparison Study of the Modulation Transfer Function of a Prototype a-Se based Flat Panel Detector with Conventional Speed Class 400 Film/screen System)

  • Park, Jang-Yong;Park, Ji-Koon;Kang, Sang-Sik;Moon, Chi-Woong;Lee, Hyung-Won;Nam, Sang-Hee
    • 전자공학회논문지SC
    • /
    • 제40권3호
    • /
    • pp.163-171
    • /
    • 2003
  • 디지털 방사선 검출기의 성능을 측정하기 위해 변조전달할수(Modulation Transfer Function)을 측정하여 기존 방사선 영상 시스템인 필름/스크린과 비교하였다. 제작된 디지털 방사선 검출기는 TFT 패널위에 진공 증착법을 통해 비정질 셀레늄이 코팅되었다. 비교 측정물이 감도 400의 필름/스크린은 아날로그 방식의 방사선 검출기로서 현재 임상에서 이용되고 있는 필름이다. Square wave & slit 측정법을 통해 두 시스템의 변조전달함수를 측정하였다. 필름/스핀린의 반치폭(FWHM)은 357㎛(1.4 lp/mm at 50% spatial frequency)으로 측정되었으며, 디지털 방사선 검출 시스템은 200㎛(2.5 lp/mm at 50%)였다. 영상의 표현성능 평가의 결과 디지털 방사선 시스템은 필름 시스템보다 높은 것으로 나타났다.

유연한 Gd2O2S:Tb 증감지 제작 및 피로누적에 대한 영향 (Fabrication of Bendable Gd2O2S:Tb Intensifying Screen and Evaluation of Fatigue Properties)

  • 박지군;양승우;전제훈;김주희;허예지;강상식;김교태
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.611-617
    • /
    • 2017
  • 본 연구에서는 연성을 형광체 층이 가질 수 있다면 외부의 기계적 외력에 대하여 장기간 안정성을 확보할 수 있을 것으로 기대하였다. 이에 본 연구에서는 스크린 프린팅 공법을 통하여 유연한 $Gd_2O_2S:Tb$ 증감지를 제작하였고 장기적인 외력에 의한 피로누적과 반복적인 외력에 의한 피로누적에 따른 영향을 고찰하고자 RMS 분석과 히스토그램을 분석을 통하여 영상 균일도를 평가하였다. 연구 결과, 지속적인 외력에 대하여는 지배적인 픽셀 영역이 일정하게 유지되면서 RSD가 10% 이내를 만족하였으나, 반복적인 외력의 경우 지배적인 픽셀 영역이 3 영역으로 분할되며 영상 균일도에 악영향을 미치며 RSD가 10% 이상으로 증가하는 것으로 나타났다. 이러한 결과를 바탕으로 기존 방사선증감지에 대비하여 기계적 안정성을 확보함으로써 곡면 검출기의 적용 가능성을 제시하였으나 아직까지 플렉시블 검출기에 적용하기 위해서는 추가적인 연구가 필요할 것으로 사료된다. 이러한 결과 유연성을 가진 방사선 증감지는 다양한 곡면에 적용이 가능하므로 향후 핵의학, 치료용, 산업 분야 등과 같은 다양한 분야에 적용할 수 있을 것으로 기대된다.

$BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교 (Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor)

  • 최장용;박지군;공현기;안상호;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF

신개념 치과용 X-선 영상장치 소개 - 강내형 X-선 튜브 (Introduction of Dental X-ray Imaging with New Concept - intra Oral x-ray Tube)

  • 조성호;김동영;백광우;이레나
    • 전자공학회논문지SC
    • /
    • 제48권4호
    • /
    • pp.94-101
    • /
    • 2011
  • 구내 치근단 촬영을 위한 수 많은 영상 장치가 활발히 연구되고 있으나, 현재까지의 X 선 장치는 강내형 센서 기반의 촬영 장치를 사용함으로서 환자의 고통, 피폭선량 등 많은 문제점이 있어왔다. 본 연구에서는 이러한 여러 문제점들을 해결할 수 있을 뿐만 아니라 이 분야에 새로운 변화를 가져올 수 있는 신개념의 치근단 촬영장치인 강내형 X-선 튜브를 사용한 치과용 영상 시스템을 소개한다. 이 신개념 치근단 X 선 촬영 시스템은 초소형 열전자 또는 냉전자 기반의 초소형 X-선 튜브, CMOS 기반의 검출기 및 이에 상응하는 자동 위치제어 및 시스템 제어장치를 포함한 몸체 부분으로 구성된다. 제안한 신개념 촬영장치의 가능성을 알아보기 위하여 XOFT사의 초소형 X-선 튜브를 이용하여 시스템을 구축하였으며 이러한 시스템의 성능 평가를 콜리메이터 유무에 따라 평가하였다. 또한 기존 시스템과 신개념 영상장치를 모두 이용하여 동일 치아 영상을 획득한 후 비교 분석 함으로서 제안된 시스템이 보다 우수한 영상 획득 및 분석이 가능함을 보여 주었으며 이러한 결과는 치근단 X 선 촬영장치 분야에 새로운 변화를 가져올 수 있을 것으로 사료된다.