Design and Construction of Multi-wire Proportional Counter and Preamplifier for Measurement of Charged Particle (하전입자의 측정을 위한 다중선 비례계수기와 전치증폭기의 설계 제작)

  • Kim, Jong-Soo;Yoon, Suk-Chull
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.139-143
    • /
    • 1996
  • A multi-wire proportional counter with large sensitive area was designed and constructed considering diameter of anode wire. its material and space. A preamplifier connecting detector to main amplifier or counter was also designed and constructed for measurement output pulse from multi-wire proportional counter. The preamplifier was composed of charge-sensitive differential circuit. clipping circuit and amplification circuit. To test the performance of this equipment, terminal output pulse from the preamplifier was measured and compared with noise For these tests $^{239}Pu(360 Bq)\;and\; ^{90}Sr/^{90}Y(250 Bq)$ were used as radiation sources. The noise ingredient contributing to the maximum amplitude(180mV from $^{239}Pu$ and 200 mV from $^{90}Sr/^{90}Y$) was found to be very small(8 mV) Piled up pulse occurring at the output pulse of charge-sensitive differential circuit was measured as an independent pulse since this affected the amplification in the clipping circuit and amplification circuit. This information can be used to improve the loss of measurement due to piled up pulse.

  • PDF

The Measurement and Evaluation of X-ray Characteristics of Cadmium Sulfide as a Multi-function Dosimeter (다기능 선량계로서의 Cadmium sulfide의 X-선에 대한 특성 평가)

  • Park, Sung-Kwang;Park, Young-Min;Cho, Heung-Lae;Nam, Sang-Hee
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.161-166
    • /
    • 2003
  • To evaluate the performance of cadmium sulfide as a multi-function X-ray dosimeter, we made an X-ray detector that was based on cadmium sulfide using evaporation technology, and measured its response to X-ray exposure. The voltages of cadmium sulfide were measured on the various X-ray tube potentials, X-ray tube currents and exposure times. The regression analysis of the voltage response of CdS on the tube-potential variation was y=0.0995x-0.1146 ($R^2$=0.9595, $\sigma$=0.08, standard error=2%) and the regression analysis of the voltage response of CdS on the tube-potential variation was y=0.0439x+1.1891 ($R^2$=0.9021, $\sigma$=0.04, standard error=1.8%) The regression analysis of the voltage response of CdS on the X-ray exposure time variation was y=8.2853+5.5878 ($R^2$=0.7287, $\sigma$=0.06, standard error=1.9%). In conclusion, cadmium sulfide responded linearly to the variation X-ray conditions, suggesting cadmium sulfide to be a feasible X-ray sensor of multi-function dosimeter related instruments.

  • PDF

PSNR Correlation between CR and DR according to Changed KvP (CR과 DR의 kVp 변화에 따른 PSNR 상관관계)

  • Kim, Jisun;Ahn, Byungju
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.417-422
    • /
    • 2014
  • In this study, the influence degree of the scattering of the line depending on the incident energy of the radiation objective was to evaluate a new method of quantitative methods of PSNR is provided.Value of MSE and PSNR of the DR and the Target is placed at the left when there was no change in CR Target, the change appeared to ttaran MSE and PSNR value in tube voltage. Both CR and DR seen that there is a variation of the MSE and PSNR depending on the tube voltage change Computon showed that the scattered radiation effects. If the CR and DR 80 The changes in the MSE and PSNR experience the symptoms suddenly occur in areas kVp was found to affect the optoelectronic Computon E, and at the same time, the scattered radiation detector Computon Computon by scattering due to the photoelectric effect. CR and DR of the imaging device in the future on the basis of the energy bands of the photoelectric effect of 60 kVp 70 kVp, 80 kVp, 90 kVp, compares the value of the PSNR and MSE 100 kVp in accordance with the change of the tube voltage of the CR and device DR proposes jigil scattering study of the degradation of the line quality is achieved.

Dosimetry of $^{222}Rn$ Component in Outdoor Natural Background Radiation (자연 방사선량 중 $^{222}Rn$기여 성분 정량 해석)

  • Jun, Jae-Shik;Oh, Hi-Peel;Chae, Ha-Suk;Lee, Byung-Young;Kim, Do-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.10-17
    • /
    • 1989
  • A study for the assessment of dose given by outdoor radon to respiratory system has been carried out by making use of radon-cups containing CR-39 plastic track detectors. Detection efficiencies were determined by irradiation of the radon-cups in a standard radon chamber of known concentration. Thus determined detection factors of CR-39 plastic track detector in bare, open cup and filtered cup geometry are found to be 0.273, 0.0813 and 0.0371 $trmm^{-2}$/(37$Bqm^{-3}{\cdot}d$), respectively, which are chemically etched in 30% NaOH solution of $70^{\circ}C$ for 220 minutes. The outdoor radon concentrations measured at Taejeon(Chungnam National University) from May 1988 to March 1989 are in the range of 27.4 - 135.8 Bq/$m^3$(0.74 - 3.67pCi/l)by open cup and 16.7 - 143.9 Bq/$m^3$(0.45 - 3.89 pCi/l) by filtered cup, which yield overall annual average value of outdoor radon concentration of $70.8Bq/m^3$(1.91 pCi/l). Corresponding effective dose equivalent rate to respiratory system of ICRP standard man is assessed to be 520 nSv /h.

  • PDF

An Improved Movable 3 photomultiplier (3PM)-γ Coincidence Counter Using Logical Sum of Double Coincidences in β-Channel for Activity Standardization

  • Hwang, Han Yull;Lee, Jong Man
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.2
    • /
    • pp.76-80
    • /
    • 2020
  • Background: To improve the measurement accuracy of liquid-scintillation counting for activity standardization, it is necessary to significantly reduce the background caused by thermal noise or after-pulses. We have therefore improved a movable 3 photomultiplier (3PM)-γ coincidence-counting method using the logical sum of three double coincidences for β events. Materials and Methods: We designed a new data-acquisition system in which β events are obtained by counting the logical sum of three double coincidences. The change in β-detection efficiency can be derived by moving three photomultiplier tubes sequentially from the liquid-scintillation vial. The validity of the method was investigated by activity measurement of 134Cs calibrated at the Korea Research Institute of Standards and Science (KRISS) with 4π(PC)β-γ(NaI(Tl)) coincidence counting using a proportional counter (PC) for the β detector. Results and Discussion: Measurements were taken over 14 counting intervals for each liquidscintillation sample by displacing three photomultiplier tubes up to 45 mm from the sample. The dead time in each β- and γ-counting channel was adjusted to be a non-extending type of 20 ㎲. The background ranged about 1.2-3.3 s-1, such that the contributions of thermal noise or after-pulses were negligible. As the β-detection unit was moved away from the sample, the β-detection efficiencies varied between 0.54 and 0.81. The result obtained by the method at the reference date was 396.3 ± 1.7 kBq/g. This is consistent with the KRISS-certified value of 396.0 ± 2.0 kBq/g within the uncertainty range. Conclusion: The movable 3PM-γ method developed in the present work not only succeeded in reducing background counts to negligible levels but enabled β-detection efficiency to be varied by a geometrical method to apply the efficiency extrapolation method. Compared with our earlier work shown in the study of Hwang et al. [2], the measurement accuracy has much improved. Consequently, the method developed in this study is an improved method suitable for activity standardization of β-γ emitters.

Efficacy of Lens Shielding Device to Prevent Cataract with Radiotherapy for Orbit or Ocular Adnexal Tumor (안와 및 안부속기 종양의 방사선치료에서 백내장의 예방을 위한 렌즈보호 장치의 효용성)

  • Cho, Jung-Keun;Cho, Hyun-Sang;Han, Tae-Jong
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.12
    • /
    • pp.139-144
    • /
    • 2007
  • Radiotherapy which is the most effective for orbit lymphoma has been used increasingly due to the increase of orbit or ocular adnexal tumor patients. Curative effects and convalescence have been being more satisfied thanks to remarkable development of cancer chemotherapy and medical treatments, but side effects such as cataract, dry eye and retinopathy still break out. Thus, in this study, a Lens Shielding Device (LSD hereafter) was designed to prevent occurring of cataract due to radiation therapy for orbit lymphoma and its efficacy through dosimetry were evaluated. And in this paper, its manufacturing process was also explained. LSD is composed of a cover body covering the lens and a side fixing part supporting the cover body. To measure radiation, the patient therapy conditions were simulated and the measurement of the radiation was conducted with Thermo Luminescence Detector (TLD) and Markus chamber. The average TLD value was 5.7% and the TLD value and Markus chamber value were acquired as 4.2% and 5.1% respectively at 6 mm depth where zero lens center was located. Only 1.5Gy ($300Gy{\times}\;5%$) or 5% of total 30Gy with 9 MeV electron beam is estimated to affect on patient's lens. That is smaller dose than the threshold value of cataract (2GY) or the value (5Gy) that was reported to cause cataract in clinical conditions. Thus, these findings suggest that LSD be very useful for prevention of cataract during radiotherapy for malignant lymphoma of orbit and ocular adnexa. Furthermore, it might be possible to reduce patient's discomfort caused by alien substances and to make it easier to fix the device with customized manufacturing manners.

Absorbed Dose Measurement by the MIRD System in the $^{131}I$ Treated Thyroid Cancer Patients (갑상선 암 환자에서 $^{131}I$ 치료시 MIRD Schema에 의한 흡수선량의 평가)

  • Lim, Sang-Moo;Woo, Kwang-Sun;Chung, Wee-Sup;Hong, Sang-Woon;Kim, Jang-Hee;Kim, Ki-Sup
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.54-60
    • /
    • 1995
  • Medical Internal Radiation Dose(MIRD) schema was developed for calculating the absorbed dose from the administered radiopharmaceuticals. With the biological distribution data and the physical properties of the radionuclide we can estimate the absorbed dose by the MIRD schema. For the thyroid cancer patients received $^{131}I$ therapy, the absorbed dose to the bone marrow is the limiting factor to the administered dose, and the duration of admission is deter-mined by the retained activity in the whole body. To monitor the whole body radioactivity, we used Eberline Smart 200 system using ionization chamber as a detector. With the time activity curve of the whole body, total body residence time was obtained. From the ICRP publication 53, the residence times of the source organs, such as kidney, urinary bladder content and stomach, were used to calculate the absorbed doses of the target organs, such as stomach, red marrow, bladder wall and remaineder total body. In 8 thyroid cancer patients with 175 mci of $^{131}I$ administered orally, the mean absorbed dose in the bladder wall was 375.1, in the stomach 285.1, red marrow 25.4 and total body 22.4 rad respectively. For the monitoring of the large administered activity, this method seemed to be quite useful.

  • PDF

A Kinetics Study of Rn Daughter and Atmospheric Trace Gas Using Alpha Track Detection (알파비적검출방법에 의한 대기중 라돈딸핵종의 화학적 동특성연구)

  • Yoon, Suk-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.79-83
    • /
    • 1995
  • A number of investigators have reported formation of radiolytic ultrafine particles produced by the interaction of ionizing radiation with atmospheric trace gases. Previous studies have suggested that a very high localized concentration of the hydroxyl radical produced by the radiolysis of water can react with atmospheric trace gases such as $SO_2$ and produce lower vapor pressure compounds that can subsequently nucleate. To determine the trace gas and water vapor concentration dependence of the active, positively charged, first decayt product of radon (Po-218), a well-controlled radon chamber was used in this research. The mobility spectrum of the decay products in the range of $0.07-5.0cm^2/V\;sec$ from the radon chamber was measured using alpha track detector installed inside a specially-designed electrostatic spectrometer. Measurements were taken for different concentrations (0.5ppm to 5ppm) of $SO_2$ in Purified, Compressed air. A kinetics Study following the clustering of $SO_2$ around the $PoO_x^+$ ion in an excess of $SO_2$ for interpretation of the reaction processes was performed.

  • PDF

Effect of First-Aid Drugs on Internal Contamination of Radiostrontium (방사성(放射性) 스트론듐의 체내오염(體內汚染)에 대한 응급처치제(應急處置劑)의 효과(效果))

  • Chung, In-Yong;Kim, Tae-Whan;Chin, Soo-Yil
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.16-23
    • /
    • 1989
  • To obtain the basic data for protective roles and first-aid of radiation hazard, the present studies were carried out to evaluate the decontamination of radiostrontium by the First-Aid drugs. Each mouse was administered intraperitoneally dose of sodium alginate 5mg, $CaNa_3DTPA$ 8.4mg and saline 5ml following the internal contamination with 1 $\mu$Ci of strontium as $^{85}SrCl_2$. $^{85}Sr$ was determined by the radioactivity of body burden, urinary excretion, fecal excretion and organ distribution by Ge-detector and MCA. The results are summarized as follows. 1. Effective half life on whole body retention $^{85}Sr$ was determined at 33 hours. 2. The decontamination effect of First-Aid durgs on the body $^{85}Sr$ burden were increased $CaNa_3DTPA$ (4.7 times), sodium alginate (1.7 times) and saline (2.4 times) respectively. 3. Strontium were excreted through urine (35.4%), feces (64.4%) and other (0.2%). But on the $^{85}Sr$ excretion routes following First-Aid drugs treatment, strontium-85 mainly were excreted through urine after $CaNa_3DTPA$ and saline treatment, and was excreted through feces after sodium alginate treatment. 4. The organ distribution of strontium-85 is vertebra, femur, sternum and liver in order Finally, the extrapolations from these data to victims were suggested that the rapid administration of $CaNa_3DTPA$, sodium alginate and saline simultaneously were markedly increased the decontamination effects on the internal contamination of radiostrontium.

  • PDF

Calculation of Primary Electron Collection Efficiency in Gas Electron Multipliers Based on 3D Finite Element Analysis (3차원 유한요소해석을 이용한 기체전자증폭기의 1차 전자수집효율의 계산)

  • Kim, Ho-Kyung;Cho, Min-Kook;Cheong, Min-Ho;Shon, Cheol-Soon;Hwang, Sung-Jin;Ko, Jong-Soo;Cho, Hyo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • Gas avalanche microdetectors, such as micro-strip gas chamber (MSGC), micro-gap chamber (MGC), micro-dot chamber (MDOT), etc., are operated under high voltage to induce large electron avalanche signal around micro-size anodes. Therefore, the anodes are highly exposed to electrical damage, for example, sparking because of the interaction between high electric field strength and charge multiplication around the anodes. Gas electron multiplier (GEM) is a charge preamplifying device in which charge multiplication can be confined, so that it makes that the charge multiplication region can be separate from the readout micro-anodes in 9as avalanche microdetectors possible. Primary electron collection efficiency is an important measure for the GEM performance. We have defined that the primary electron collection efficiency is the fractional number of electron trajectories reaching to the collection plane from the drift plane through the GEM holes. The electron trajectories were estimated based on 3-dimensional (3D) finite element method (FEM). In this paper, we present the primary electron collection efficiency with respect to various GEM operation parameters. This simulation work will be very useful for the better design of the GEM.